期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Novel control scheme for 3-phase PWM current-source converters under unbalanced source voltage conditions 被引量:1
1
作者 李玉玲 楼珍丽 张仲超 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第2期263-268,共6页
Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controlle... Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controller based on compensation for unbalanced source voltage and current. With the proposed scheme, the second harmonics of the output current are eliminated and low-order harmonics of the source current are reduced effectively. Simulation and experimental results con- firmed the feasibility of the proposed method. 展开更多
关键词 PWM current-source converters (PWM-CSC) unbalanced source voltage conditions Deadbeat control
下载PDF
Model Predictive Direct Power Control of Grid-connected Converters Considering Unbalanced Filter Inductance and Grid Conditions 被引量:1
2
作者 Weichen Yang Shihong Miao +3 位作者 Zhiwei Liu Ji Han Yulong Xiong Qingyu Tu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1279-1288,共10页
The grid-connected converter(GCC) is widely used as the interface between various distributed generations and the utility grid. To achieve precise power control for GCC, this paper presents a model predictive direct p... The grid-connected converter(GCC) is widely used as the interface between various distributed generations and the utility grid. To achieve precise power control for GCC, this paper presents a model predictive direct power control(MPDPC)with consideration of the unbalanced filter inductance and grid conditions. First, the characteristics of GCC with unbalanced filter inductance are analyzed and a modified voltage control function is derived. On this basis, to compensate for the power oscillation caused by unbalanced filter inductance, a novel power compensation method is proposed for MPDPC to eliminate the DC-side current ripple while maintaining sinusoidal grid current. Besides, to improve the control robustness against mismatched filter inductance, a filter inductance identification scheme is proposed. Through this scheme, the estimated value of filter inductance is updated in each control period and applied in the proposed MPDPC. Finally, simulation results in PSCAD/EMTDC confirm the validity of the proposed MPDPC and the filter inductance identification scheme. 展开更多
关键词 Inductance identification grid-connected converter model predictive control power oscillation elimination unbalanced grid conditions
原文传递
Elimination of Partial Overloading of Generators Under Unbalanced Operating Conditions of Power Systems
3
作者 Sudhakar Reddy Sama Subrata Paul Sunita Halder Nee Dey 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第1期81-87,共7页
Unbalanced operating condition in a power system can cause partial overloading of the generators in the network,a condition where one or two of the three phases of the generator become overloaded even if the total 3-p... Unbalanced operating condition in a power system can cause partial overloading of the generators in the network,a condition where one or two of the three phases of the generator become overloaded even if the total 3-phase power output of the generator is within its specified limit.Partial overloading of generators beyond certain limits is undesirable and must be avoided.Distribution systems are often subjected to highly unbalanced operating conditions.Introduction of distributed generations(DGs),therefore,has rendered today’s distribution systems quite susceptible to this problem.Mitigation of this problem requires the issue to be addressed properly during analysis,operation and planning of such systems.Analysis,operation and planning of power networks under unbalanced operating condition require 3-phase load flow study.The existing methods of 3-phase load flow are not equipped to take into account any limit on the loadings of the individual phases of the generators.In the present work,a methodology based on NewtonRaphson(N-R)3-phase load flow with necessary modifications is proposed.The proposed methodology is able to determine the safe loading limits of the generators,and,can be adopted for operation and planning of power networks under unbalanced operating conditions to overcome the above difficulties.Test results on IEEE-37 bus feeder network are presented to demonstrate the effectiveness of the proposed method. 展开更多
关键词 Newton Raphson 3-phase load flow partial overloading of generators unbalanced operating condition of power systems
原文传递
上一页 1 下一页 到第