期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Electromagnetic Performance Prediction for the Symmetrical Dual Three-phase Surface-mounted PMSM under Open-phase Faults Based on Accurate Subdomain Model 被引量:1
1
作者 Zhe Liang Deliang Liang +1 位作者 Peng Kou Shaofeng Jia 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期422-437,共16页
The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase f... The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase faulty conditions.The model derivations are extended from previous accurate subdomain models accounting for slotting effects.Compared with most conventional subdomain models for traditional three-phase machines with nonoverlapping winding arrangement,the subdomain model proposed in this paper applied for the 24-slot/4-pole dual three-phase machine with symmetrical overlapping winding arrangement.In order to investigate the postfault electromagnetic performance,the reconfigured phase currents and then current density distribution in stator slots under different open-circuit conditions are discussed.According to the developed model and postfault current density distribution,the steady-state electromagnetic performance,such as the electromagnetic torque and unbalanced magnetic force,under open-circuit faulty conditions are obtained.For validation purposes,finite element analysis(FEA)is employed to validate the analytical results.The result indicate that the postfault electromagnet performance can be accurately predicted by the proposed subdomain model,which is in good agreement with FEA results. 展开更多
关键词 Dual three-phase Permanent magnet synchronous machine Subdomain model Electromagnetic torque unbalanced magnetic force Open-phase fault
下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
2
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE INVERTER three-phase FOUR-LEG INVERTER unbalanced Load Imbalanced VOLTAGE
下载PDF
Research on a New Control Strategy of Three Phase Inverter for Unbalanced Loads
3
作者 Wenhua HU Weiming Ma Chunxi LIU 《Journal of Electromagnetic Analysis and Applications》 2010年第1期39-44,共6页
One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing... One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms. 展开更多
关键词 three-phase INVERTER unbalanced Load the three-phase OUTPUT Voltage SYMMETRIC Medium Frequency P+Resonant CONTROLLER
下载PDF
Coordinated Control of Parallel Three-phase Four-wire Converters in Autonomous AC Microgrids
4
作者 Rui Liu Li Guo Xialin Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第5期2065-2078,共14页
The coordinated control of parallel three-phase fourwire converters in autonomous AC microgrids is investigated in this paper.First,based on droop control,virtual impedance is inserted in positive-,negative-and zero-s... The coordinated control of parallel three-phase fourwire converters in autonomous AC microgrids is investigated in this paper.First,based on droop control,virtual impedance is inserted in positive-,negative-and zero-sequences to enhance system damping and imbalance power sharing.Then,to facilitate virtual impedance design,small signal models of the three-sequence equivalent circuits are established respectively.Corresponding indexes are proposed to comprehensively evaluate the impact of sequence virtual impedance on current sharing accuracy,voltage quality at the point of common coupling(PCC)and system stability.In addition,constraint of DClink voltage is also considered to avoid over modulation when subjected to unbalanced loads.Furthermore,to address the PCC voltage degradation resulting from virtual impedance,a voltage imbalance compensation method,based on low-bandwidth communication,is proposed.Finally,simulation and experimental results are provided to verify the correctness of the theory model,indicating that the proposed method can achieve PCC voltage restoration while guaranteeing the current sharing accuracy with desirable dynamics. 展开更多
关键词 AC microgrids sequence virtual impedance three-phase four-wire(3P4W)converter voltage imbalance compensation
原文传递
Modeling method of sequence admittance for three-phase voltage source converter under unbalanced grid condition 被引量:1
5
作者 Yang CEN Meng HUANG Xiaoming ZHA 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第3期595-606,共12页
The admittance is a strong tool for stability analysis and assessment of the three-phase voltage source converters(VSCs) especially in grid-connected mode.However, the sequence admittance is hard to calculate when the... The admittance is a strong tool for stability analysis and assessment of the three-phase voltage source converters(VSCs) especially in grid-connected mode.However, the sequence admittance is hard to calculate when the VSC is operating under unbalanced grid voltage conditions. In this paper, a simple and direct modeling method is proposed for a three-phase VSC taking the unbalanced grid voltage as a new variable for the system.Then coupling in the three-phase system can be calculated by applying the harmonic linearization method. The calculated admittance of three-phase VSCs is verified by detailed circuit simulations. 展开更多
关键词 unbalanced GRID VOLTAGE three-phase VOLTAGE source converter Harmonic linearization Positive and negative SEQUENCE ADMITTANCE Stability
原文传递
Analysis on Circulating Current and Split Capacitor Voltage Balance for Modular Multilevel Converter Based Three-phase Four-wire Split Capacitor DSTATCOM 被引量:1
6
作者 Lei Lin Jialu He Chen Xu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第3期657-667,共11页
We propose a modular multilevel converter(MMC)based three-phase four-wire(3P4W)split capacitor distribution static synchronous compensator(DSTATCOM),aiming at compensating unbalanced and reactive load currents.Due to ... We propose a modular multilevel converter(MMC)based three-phase four-wire(3P4W)split capacitor distribution static synchronous compensator(DSTATCOM),aiming at compensating unbalanced and reactive load currents.Due to the zero-sequence current compensation,the circulating current char-acteristics of 3P4W MMC-DSTATCOM are different from conventional MMCs.Moreover,the distinct working principle of IMMC would affect the features of split capacitor voltage.The decoupled positive-,negative-and zero-sequence second-order and DC components of the circulating current are deduced explicitly.Two proportional-integral controllers with dual dq transformation are employed to suppress the positive-and negative-sequence components of second-order circulating current,while quasi proportional-resonance controller is designed to eliminate the zero-sequence component.Besides,the phenomenon of the unbalanced split capacitor voltages is revealed,and fast-tracking balancing method by controlling zero-sequence current flowing through the split capacitors is provided.Digital simulation results verify the accuracy of the analysis and the feasibility of the suppression methods. 展开更多
关键词 Circulating current modular multilevel converter(MMC) distribution static synchronous compensator(DSTATCOM) split capacitor three-phase four-wire(3P4W)
原文传递
Simulation Research on a SVPWM Control Algorithm for a Four-Leg Active Power Filter 被引量:5
7
作者 ZHOU Juan WU Xiao-jie GENG Yi-wen DAI Peng 《Journal of China University of Mining and Technology》 EI 2007年第4期590-594,共5页
In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg act... In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg active power filter,a 3-Dimensional Pulse Width Modulation (PWM) technique,is presented. The theoretical deduction of a space vector PWM (SVPWM) algorithm is given in this paper. The paper also analyzes the distribution of the volt-age-space vector of the four-leg converter in αβγ coordinates and describes methods to determine the location of the voltage-space vector and to calculate duration time. Finally,the algorithm is implemented in simulation; the results show that the total harmonic distortion (THD) of the three phase-current waveforms is reduced. The neutral wire current,after compensation,is about 0 A showing that the topology of the four-leg shunt APF is feasible and the proposed scheme is effective. 展开更多
关键词 three-phase four-wire system shunt active power filter 3-Dimensional space vector PWM
下载PDF
Zero Sequence Voltage and Current Control in Four-wire Grids-fed by Grid-forming Inverters
8
作者 Zixian Zhu Wei Chen Vito Giuseppe Monopoli 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第6期2272-2279,共8页
Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase ... Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase line losses but also result in neutral potential variations.For the LV AC distribution grid established by a grid-forming inverter(e.g.,uninterruptible power supply and solid-state-transformer),it also suffers from the same neutral current issues.Therefore,this paper comparatively studies several neutral current control approaches and their impacts on grid voltage balance,which is required by grid code.Then,this paper proposes an optimal neutral current control approach,which can obtain maximum neutral current suppression with less impact on grid voltage balance.The correctness of the theoretical analysis is validated through both simulation and experimental results. 展开更多
关键词 LV AC grid neutral current reduction grid-forming inverter three-phase four-wire system
原文传递
Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
9
作者 Victor A.F.Almeida Glauco N.Taranto José M.T.Marinho 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1269-1278,共10页
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.... This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations. 展开更多
关键词 Converter-interfaced generator three-phase model power system protection negative-sequence current injection negative-sequence current protection unbalanced fault three-phase root-mean-square(RMS)dynamic simulation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部