Using the glucose and L-glutamic-acid to prepare the standard substance according to the ratio of 1:1, and the artificial seawater and the standard substance to prepare a series of standard solutions, the distributio...Using the glucose and L-glutamic-acid to prepare the standard substance according to the ratio of 1:1, and the artificial seawater and the standard substance to prepare a series of standard solutions, the distribution pattern of uncertainty in measurement of seawater COD is obtained based on the measured results of the series of standard solutions by the potassium iodide-alkaline potassium permanganate determination method. The distribution pattern is as follows: Uncertainty in measurement is big and not constant at the high end, but small and constant at the low end.展开更多
This research developed the technology which united ISO-GUM (International Organization of Standard-Guide to Express of Uncertainty in Measurement) and QE (Quality Engineer) strategically and employed both feature...This research developed the technology which united ISO-GUM (International Organization of Standard-Guide to Express of Uncertainty in Measurement) and QE (Quality Engineer) strategically and employed both feature efficiently. Although to tow technology of purpose use is same, each has future. The purpose is scheduled to improve the accuracy as a result of the clinical examinations. The result of research was used for diagnosis by equivalent Quality Control (eqQC) of the same level when and where, that are needed for broader-based medical system of the time of IT-era. Since National Institute of Standard and Technology (NIST) is recommend use of complicated operation by ISO-GUM for uniting, realization required the newest high quality computer technology. The algorithm of the complexity system of operation is that Fast Fourier Transform (FFT), Inverse Fast Fourier Transform (IFFT) and Multi-variance Analysis (MA) are needed in Fig. 4. The main new improving points are changed of ambiguous expression method of data, and the pursuit which the cause of worsens accuracy put into data. All data with an assurance reported the final result for patient or donor. Medical laboratory quality system service is offered essential in the laboratory to be correct result for health care by Good Laboratory Practices (GLP) useful ISO 15189. Quality Assurance (QA) is achieved though system reliability.展开更多
文摘Using the glucose and L-glutamic-acid to prepare the standard substance according to the ratio of 1:1, and the artificial seawater and the standard substance to prepare a series of standard solutions, the distribution pattern of uncertainty in measurement of seawater COD is obtained based on the measured results of the series of standard solutions by the potassium iodide-alkaline potassium permanganate determination method. The distribution pattern is as follows: Uncertainty in measurement is big and not constant at the high end, but small and constant at the low end.
文摘This research developed the technology which united ISO-GUM (International Organization of Standard-Guide to Express of Uncertainty in Measurement) and QE (Quality Engineer) strategically and employed both feature efficiently. Although to tow technology of purpose use is same, each has future. The purpose is scheduled to improve the accuracy as a result of the clinical examinations. The result of research was used for diagnosis by equivalent Quality Control (eqQC) of the same level when and where, that are needed for broader-based medical system of the time of IT-era. Since National Institute of Standard and Technology (NIST) is recommend use of complicated operation by ISO-GUM for uniting, realization required the newest high quality computer technology. The algorithm of the complexity system of operation is that Fast Fourier Transform (FFT), Inverse Fast Fourier Transform (IFFT) and Multi-variance Analysis (MA) are needed in Fig. 4. The main new improving points are changed of ambiguous expression method of data, and the pursuit which the cause of worsens accuracy put into data. All data with an assurance reported the final result for patient or donor. Medical laboratory quality system service is offered essential in the laboratory to be correct result for health care by Good Laboratory Practices (GLP) useful ISO 15189. Quality Assurance (QA) is achieved though system reliability.