BACKGROUND Adrenocortical oncocytoma is a rare,mostly benign,nonfunctional tumor that is typically detected incidentally.Its diagnosis is challenging because of the absence of distinctive imaging characteristics,neces...BACKGROUND Adrenocortical oncocytoma is a rare,mostly benign,nonfunctional tumor that is typically detected incidentally.Its diagnosis is challenging because of the absence of distinctive imaging characteristics,necessitating pathological validation.CASE SUMMARY We present a case report of a 35-year-old woman with an adrenal mass located on the left side,where endoscopic ultrasound-guided fine-needle aspiration(EUSFNA)was performed after comprehensive diagnostic assessment.Our results are consistent with those of previously documented cases regarding tumor demographics and anatomical location.Given the limited number of reports on this condition,long-term follow-up is crucial to enhance our understanding of its prognosis.CONCLUSION For patients with adrenocortical oncocytoma,EUS-FNA can enables collection of preoperative tissue specimens leading to suitable treatment strategies.展开更多
In the process of launching guided projectile under the conventional system, it is difficult to effectively obtain the precise navigation parameters of the projectile in the high dynamic environment. Aiming at this pr...In the process of launching guided projectile under the conventional system, it is difficult to effectively obtain the precise navigation parameters of the projectile in the high dynamic environment. Aiming at this problem, this paper describes a new system of guided ammunition based on tail spin reduction. After analyzing the mechanism of the ammunition's tail spin reduction, a navigation method of large scale difference tail control simple guided ammunition based on speed constraint is proposed. In this method,the corresponding navigation constraints can be carried out by combining the rotation speed state of the ammunition itself, and the optimal solution of navigation parameters during the flight of the missile can be obtained by Extended Kalman Filter(EKF). Finally, the performance of the proposed method was verified by the simulation environment, and the hardware-in-the-loop simulation test and flight test were carried out to verify the performance of the method in the real environment. The experimental results show that the proposed method can achieve the optimal estimation of navigation parameters for simple guided ammunition with large-scale difference tail control. Under the conditions of simulation test and hardware-in-loop simulation test, the position and velocity errors calculated by the method in this paper converged. Under the condition of flight test, the spatial average error calculated by the method described in this paper is 6.17 m, and the spatial error of the final landing point is 3.50 m.Through this method, the accurate acquisition of navigation parameters in the process of projectile launching is effectively realized.展开更多
Thickness measurement plays an important role in the monitoring of pipeline corrosion damage. However, the requirement for prior knowledge of the shear wave velocity in the pipeline material for popular ultrasonic thi...Thickness measurement plays an important role in the monitoring of pipeline corrosion damage. However, the requirement for prior knowledge of the shear wave velocity in the pipeline material for popular ultrasonic thickness measurement limits its widespread application. This paper proposes a method that utilizes cylindrical shear horizontal(SH) guided waves to estimate pipeline thickness without prior knowledge of shear wave velocity. The inversion formulas are derived from the dispersion of higher-order modes with the high-frequency approximation. The waveform of the example problems is simulated using the real-axis integral method. The data points on the dispersion curves are processed in the frequency domain using the wave-number method. These extracted data are then substituted into the derived formulas. The results verify that employing higher-order SH guided waves for the evaluation of thickness and shear wave velocity yields less than1% error. This method can be applied to both metallic and non-metallic pipelines, thus opening new possibilities for health monitoring of pipeline structures.展开更多
The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous ne...The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax(13 cases, 27.1%) and pulmonary hemorrhage(14 cases, 20.24%). ?2 test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases(17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases(60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases(41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases(70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. Key words: biopsy, CT-guided; hilum; pneumothorax; pulmonary hemorrhage展开更多
Objective:To investigate the value of application of low-dose and optimized length CT scan on puncture results,complications and patients’radiation dosage during CT-guided percutaneous biopsy of pulmonary nodules(PTN...Objective:To investigate the value of application of low-dose and optimized length CT scan on puncture results,complications and patients’radiation dosage during CT-guided percutaneous biopsy of pulmonary nodules(PTNB).Methods:A total of 231 patients with PTNB under CT guidance were collected.Low dose scanning utilized tube current of 20 mA as compared with 40 mA in conventional dosage.Optimized length in CT is defined as intentionally narrowing the range of CT scanning just to cover 25 mm(5 layers)around the target layer during needle adjustment.According to whether low-dose scans and optimized length scans techniques were utilized,patients were divided into three groups:conventional group(conventional sequence+no optimization),optimized length group(conventional sequence+optimized length),and low-dose optimized length group(low dose sequence+optimized length).The ED(effective dose),the DLP(dose length product),the average CTDIvol(Volume CT dose index),total milliampere second between subgroups were compared.Results:Compared with the conventional group,ED,intraoperative guidance DLP,total milliseconds and operation time in the optimized length group were reduced by 18.2%(P=0.01),37%(P=0.003),17.5%(P=0.013)and13.3%(P=0.021)respectively.Compared with the optimized length group,the ED was reduced by 87%,preoperative positioning,intraoperative guidance and postoperative review DLP were also reduced by 88%,total milliampere second was reduced by 79%,with an average CTDIvol was reduced by 86%,in the low-dose optimized length group(P<0.001 for all).Conclusion:Optimizing the length during CT scanning can effectively reduce the intraoperative radiation dose and reduce the operation time compared with conventional plan;low-dose and optimized length CT scan can further reduce the total radiation dose compared with optimized length group with no differences on intraoperative complications,biopsy results and operation time.展开更多
Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe seve...Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe severely affects its pressure-holding capacity,hence the early detection of internal cracks is crucial for effective pipeline maintenance strategies.This study extends the scope of guided wave-based ultrasonic testing to detect the growth of internal cracks in a natural gas distribution PE pipe.Laboratory experiments and a finite element model were planned to study the wave-crack interaction at different stages of axially oriented internal crack growth with a piezoceramic transducer-based setup arranged in a pitch-catch configuration.Mode dispersion analysis supplemented with preliminary experiments was performed to isolate the optimal inspection frequency,leading to the selection of the T(0,1)mode at 50-kHz for the investigation.A transmission index based on the energy of the T(0,1)mode was developed to trace the extent of simulated crack growth.The findings revealed an inverse linear correlation between the transmission index and the crack depth for crack growth beyond 20%crack depth.展开更多
Endoscopic ultrasound-guided biliary drainage(EUS-BD)directs bile flow into the digestive tract and has been mostly used in patients with malignant biliary obstruction(MBO)where endoscopic retrograde cholangiopancreat...Endoscopic ultrasound-guided biliary drainage(EUS-BD)directs bile flow into the digestive tract and has been mostly used in patients with malignant biliary obstruction(MBO)where endoscopic retrograde cholangiopancreatography-guided biliary drainage was unsuccessful or was not feasible.Lumen apposing metal stents(LAMS)are deployed during EUS-BD,with the newer electrocautery-enhanced LAMS reducing procedure time and complication rates due to the inbuilt cautery at the catheter tip.EUS-BD with electrocautery-enhanced LAMS has high technical and clinical success rates for palliation of MBO,with bleeding,cholangitis,and stent occlusion being the most common adverse events.Recent studies have even suggested comparable efficacy between EUS-BD and endosc-opic retrograde cholangiopancreatography as the primary approach for distal MBO.In this editorial,we commented on the article by Peng et al published in the recent issue of the World Journal of Gastrointestinal Surgery in 2024.展开更多
Carbon fiber-reinforced polymer(CFRP)is widely used in aerospace applications.This kind of material may face the threat of high-velocity impact in the process of dedicated service,and the relevant research mainly cons...Carbon fiber-reinforced polymer(CFRP)is widely used in aerospace applications.This kind of material may face the threat of high-velocity impact in the process of dedicated service,and the relevant research mainly considers the impact resistance of the material,and lacks the high-velocity impact damage monitoring research of CFRP.To solve this problem,a real high-velocity impact damage experiment and structural health monitoring(SHM)method of CFRP plate based on piezoelectric guided wave is proposed.The results show that CFRP has obvious perforation damage and fiber breakage when high-velocity impact occurs.It is also proved that guided wave SHM technology can be effectively used in the monitoring of such damage,and the damage can be reflected by quantifying the signal changes and damage index(DI).It provides a reference for further research on guided wave structure monitoring of high/hyper-velocity impact damage of CFRP.展开更多
Objective:To investigate the clinical effect of the guided bone regeneration(GBR)technique combined with temporary bridgework-guided gingival contouring in treating upper anterior tooth loss with labial bone defects.M...Objective:To investigate the clinical effect of the guided bone regeneration(GBR)technique combined with temporary bridgework-guided gingival contouring in treating upper anterior tooth loss with labial bone defects.Methods:From July 2023 to April 2024,80 patients with upper anterior tooth loss and labial bone defects were admitted to the hospital and selected as evaluation samples.They were divided into an observation group(n=40)and a control group(n=40)using a numerical table lottery scheme.The control group received treatment with the GBR technique,while the observation group received treatment with the GBR technique combined with temporary bridges to guide gingival contouring.The two groups were compared in terms of clinical red aesthetic scores(PES),labial alveolar bone density,labial bone wall thickness,gingival papillae,gingival margin levels,and patient satisfaction.Results:The PES scores of patients in the observation group were higher than those in the control group after surgery(P<0.05).The bone density of the labial alveolar bone and the thickness of the labial bone wall in the observation group were higher than those in the control group.The levels of gingival papillae and gingival margins were lower in the observation group after surgery(P<0.05).Additionally,patient satisfaction in the observation group was higher than in the control group(P<0.05).Conclusion:The GBR technique combined with temporary bridge-guided gingival contouring for treating upper anterior tooth loss with labial bone defects can improve the aesthetic effect of gingival soft tissue,increase alveolar bone density and the thickness of the labial bone wall,and enhance patient satisfaction.This approach is suitable for widespread application in healthcare institutions.展开更多
Objective: To evaluate the efficacy, feasibility and safety of contrast-enhanced CT-guided core biopsy of retroperitoneal masses. Materials and Methods: Contrast-enhanced CT-guided biopsy of retroperitoneal masses was...Objective: To evaluate the efficacy, feasibility and safety of contrast-enhanced CT-guided core biopsy of retroperitoneal masses. Materials and Methods: Contrast-enhanced CT-guided biopsy of retroperitoneal masses was performed in 26 patients. Histopathological diagnosis was obtained and accuracy was calculated. Two blinded radiologists determined feasibility of biopsy procedures on routine CT-guidance, and compared accessibility of target lesions using contrast-enhanced and non-contrast-enhanced CT. Results: Satisfactory samples were obtained in all 26 patients and pathological diagnosis was made in 24. Accuracy was 95.5%. Routine CT-guided biopsy punctures were not satisfaction in 4/26 patients, and contrast-enhanced CT scans rendered the target lesions more accessible in 16 patients. Conclusion: Contrast-enhanced CT-guided biopsy increases the feasibility of biopsy of retroperitoneal masses.展开更多
Objectives: The aim of this study was to assess the safety and efficacy of percutaneous CT-guided drainage of gastric leaks post sleeve gastrectomy. Methods: For this single-center retrospective study, we reviewed the...Objectives: The aim of this study was to assess the safety and efficacy of percutaneous CT-guided drainage of gastric leaks post sleeve gastrectomy. Methods: For this single-center retrospective study, we reviewed the clinical data of 78 patients (44 men and 34 women with an average age of 34.6 ±10.5 years and a body mass index (BMI) of 45 kg/m2 ±3.2) that underwent percutaneous CT-guided drainage of gastric leaks due to sleeve gastrectomy from September 2011 to September 2018. The outcome measurements were technical and clinical success, complications, and the need for revisional surgery. Results: The technical success rate of drain insertion was 97.5% (76/78 patients). All of the patients (76/76 patients) exhibited early clinical and laboratory improvement, and no emergency surgery was required. However, six patients underwent revisional surgery after 3 - 5 months for non-healing gastric leaks/fistulas. One patient had a major complication of active bleeding due to arterial injury;this was managed by transcatheter coil embolization. All patients underwent endoluminal stent placement and received antimicrobial therapy and nutritional support. Conclusion: Percutaneous CT-guided drainage of gastric leaks after sleeve gastrectomy is a safe, effective, and minimally invasive alternative to surgery. This technique is in line with other conservative measures (endoluminal stent placement, antimicrobial therapy, and nutritional support), which heal most gastric leaks due to sleeve gastrectomy and prevent the need for revisional surgery.展开更多
Objective: The purpose of this study is to evaluate the effectiveness and safety of CT-guided percutaneous drainage (CPD) in the management of deep neck abscesses. Factors associated with successful treatment in patie...Objective: The purpose of this study is to evaluate the effectiveness and safety of CT-guided percutaneous drainage (CPD) in the management of deep neck abscesses. Factors associated with successful treatment in patients with DNA will be identified. Methods: We retrospectively studied 29 patients who presented to the department of otolaryngology with deep neck abscesses between April 2011 and April 2015. These 29 patients were managed with CPD after antibiotic therapy or needle aspiration failed. Data on patient demographics, location of infection, existing comorbidity, duration of hospitalization, treatment received, and complications were reviewed. Results: The average age of 29 patients, including 18 men and 11 women, was 56 years old. Abscess was found in parapharyngeal space (n = 16), submandibular space (n = 7), retropharyngeal space (n = 5) and pretracheal space (n = 1). The maximum transverse diameter of abscess ranged from 4.8 cm to 8.0 cm (mean 6.03 cm). Positive cultures were found in 24 cases and the most common pathogen found was Streptococcus viridans. Average hospital stay was 6.7 days. Deep neck abscesses were completely removed without residual in all patients. No one had complications and no one died during and after CPD. Conclusion: CPD is a safe and highly effective procedure for treating patients with deep neck abscesses who do not respond to antibiotics therapy. This technique can also provide reliable evidence on pathogens responsible for deep neck abscesses and help otolaryngologists choose effective treatment to achieve better clinical success rate. We recommend that most deep neck abscesses should be managed initially by CPD before resorting to open surgery.展开更多
Purpose: To evaluate a new miniature optical navigation system for CT-guided liver interventions. Material and Methods: A two-center, prospective study was performed with four interventional radiologists. A total of 2...Purpose: To evaluate a new miniature optical navigation system for CT-guided liver interventions. Material and Methods: A two-center, prospective study was performed with four interventional radiologists. A total of 20 patients had CT-guided liver biopsy or ablation interventions utilizing the CT-Guide? navigation system (ActiViews Inc., Wakefield, MA) between July 2011 and December 2011. The navigation system consists of a self-adhesive patientsticker printed with coincident colored and radio-opaque reference markers, a miniature disposable video camera that clips on and off an interventional instrument, and software loaded on a computer to display the navigation information. The primary end point was the frequency of a satisfactory instrument position for the intended intervention. Results: The cohort consisted of 13 males and 7 females with an average age of 63.1 years (range of 38 to 80). Most of the patients, 70%, underwent CT-guided liver biopsy while the remainder had CT-guided ablation therapy. The average lesion size was 3.1 cm (range of 1.1 - 6.9 cm). All of the interventions, regardless of lesion size, met the primary end point of satisfactory instrument positioning. There were no device-related or unexpected adverse events recorded. Only one patient had a mild adverse event and it resolved without intervention. Conclusions: This study demonstrated the safety and effectiveness of the CT-Guide? navigation system for CT-guided liver interventions, for both biopsies and ablations. The targeting success rate for a satisfactory intervention was 100% with the system.展开更多
Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (...Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (TRUS-SB) is the primary diagnostic method, prebiopsy multiparametric magnetic resonance imaging (mpMRI) is gaining popularity in identifying suspicious lesions. This study addresses the lack of comprehensive investigations into the efficacy of cognitive registration TRUS targeted biopsy (COG-TB) compared to conventional TRUS-SB, considering the resource limitations of the Malaysian healthcare system. Materials and Methods: A retrospective cohort study was conducted in two Malaysian healthcare facilities. 116 adult patients with a prostate-specific antigen (PSA) level of more than 4 ng/mL who underwent both COG-TB and TRUS-SB between October 2020 and March 2022 were included. Primary outcomes were cancer detection rate and histopathological outcomes, including Gleason score. Results: COG-TB showed a higher overall cancer detection rate (50%) compared to TRUS-SB (44%). Clinically significant cancer detection rates were similar between COG-TB and TRUS-SB (37.1%). Further analysis revealed that both COG-TB and TRUS-SB detected clinically significant cancer in 30.2% of patients, did not detect it in 56.0%, and had conflicting findings in 16 patients (p Conclusion: COG-TB and TRUS-SB have comparable detection rates for clinically significant prostate cancer, with COG-TB showing a higher tendency to detect insignificant prostate cancer. Further studies comparing these methods are warranted.展开更多
文摘BACKGROUND Adrenocortical oncocytoma is a rare,mostly benign,nonfunctional tumor that is typically detected incidentally.Its diagnosis is challenging because of the absence of distinctive imaging characteristics,necessitating pathological validation.CASE SUMMARY We present a case report of a 35-year-old woman with an adrenal mass located on the left side,where endoscopic ultrasound-guided fine-needle aspiration(EUSFNA)was performed after comprehensive diagnostic assessment.Our results are consistent with those of previously documented cases regarding tumor demographics and anatomical location.Given the limited number of reports on this condition,long-term follow-up is crucial to enhance our understanding of its prognosis.CONCLUSION For patients with adrenocortical oncocytoma,EUS-FNA can enables collection of preoperative tissue specimens leading to suitable treatment strategies.
基金supported by the Natural Science Foundation of Beijing Municipality(Grant No.4212003)the Crossdisciplinary Collaboration Project of Beijing Municipal Science and Technology New Star Program(Grant No.202111)。
文摘In the process of launching guided projectile under the conventional system, it is difficult to effectively obtain the precise navigation parameters of the projectile in the high dynamic environment. Aiming at this problem, this paper describes a new system of guided ammunition based on tail spin reduction. After analyzing the mechanism of the ammunition's tail spin reduction, a navigation method of large scale difference tail control simple guided ammunition based on speed constraint is proposed. In this method,the corresponding navigation constraints can be carried out by combining the rotation speed state of the ammunition itself, and the optimal solution of navigation parameters during the flight of the missile can be obtained by Extended Kalman Filter(EKF). Finally, the performance of the proposed method was verified by the simulation environment, and the hardware-in-the-loop simulation test and flight test were carried out to verify the performance of the method in the real environment. The experimental results show that the proposed method can achieve the optimal estimation of navigation parameters for simple guided ammunition with large-scale difference tail control. Under the conditions of simulation test and hardware-in-loop simulation test, the position and velocity errors calculated by the method in this paper converged. Under the condition of flight test, the spatial average error calculated by the method described in this paper is 6.17 m, and the spatial error of the final landing point is 3.50 m.Through this method, the accurate acquisition of navigation parameters in the process of projectile launching is effectively realized.
基金Project supported by the Natural Science Foundation of Jilin Province of China(Grant Nos.20240402081GH and 20220101012JC)the National Natural Science Foundation of China(Grant No.42074139)the State Key Laboratory of Acoustics,Chinese Academy of Sciences(Grant No.SKLA202308)。
文摘Thickness measurement plays an important role in the monitoring of pipeline corrosion damage. However, the requirement for prior knowledge of the shear wave velocity in the pipeline material for popular ultrasonic thickness measurement limits its widespread application. This paper proposes a method that utilizes cylindrical shear horizontal(SH) guided waves to estimate pipeline thickness without prior knowledge of shear wave velocity. The inversion formulas are derived from the dispersion of higher-order modes with the high-frequency approximation. The waveform of the example problems is simulated using the real-axis integral method. The data points on the dispersion curves are processed in the frequency domain using the wave-number method. These extracted data are then substituted into the derived formulas. The results verify that employing higher-order SH guided waves for the evaluation of thickness and shear wave velocity yields less than1% error. This method can be applied to both metallic and non-metallic pipelines, thus opening new possibilities for health monitoring of pipeline structures.
基金supported by the National Natural Science Foundation of China(No.81102074)
文摘The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax(13 cases, 27.1%) and pulmonary hemorrhage(14 cases, 20.24%). ?2 test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases(17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases(60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases(41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases(70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. Key words: biopsy, CT-guided; hilum; pneumothorax; pulmonary hemorrhage
基金supported by grants from National Natural Science Foundation of China(No.81801804).
文摘Objective:To investigate the value of application of low-dose and optimized length CT scan on puncture results,complications and patients’radiation dosage during CT-guided percutaneous biopsy of pulmonary nodules(PTNB).Methods:A total of 231 patients with PTNB under CT guidance were collected.Low dose scanning utilized tube current of 20 mA as compared with 40 mA in conventional dosage.Optimized length in CT is defined as intentionally narrowing the range of CT scanning just to cover 25 mm(5 layers)around the target layer during needle adjustment.According to whether low-dose scans and optimized length scans techniques were utilized,patients were divided into three groups:conventional group(conventional sequence+no optimization),optimized length group(conventional sequence+optimized length),and low-dose optimized length group(low dose sequence+optimized length).The ED(effective dose),the DLP(dose length product),the average CTDIvol(Volume CT dose index),total milliampere second between subgroups were compared.Results:Compared with the conventional group,ED,intraoperative guidance DLP,total milliseconds and operation time in the optimized length group were reduced by 18.2%(P=0.01),37%(P=0.003),17.5%(P=0.013)and13.3%(P=0.021)respectively.Compared with the optimized length group,the ED was reduced by 87%,preoperative positioning,intraoperative guidance and postoperative review DLP were also reduced by 88%,total milliampere second was reduced by 79%,with an average CTDIvol was reduced by 86%,in the low-dose optimized length group(P<0.001 for all).Conclusion:Optimizing the length during CT scanning can effectively reduce the intraoperative radiation dose and reduce the operation time compared with conventional plan;low-dose and optimized length CT scan can further reduce the total radiation dose compared with optimized length group with no differences on intraoperative complications,biopsy results and operation time.
基金the financial support provided by USDOT Pipeline and Hazardous Materials Safety Administration (PHMSA)through the Competitive Academic Agreement Program (CAAP)。
文摘Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe severely affects its pressure-holding capacity,hence the early detection of internal cracks is crucial for effective pipeline maintenance strategies.This study extends the scope of guided wave-based ultrasonic testing to detect the growth of internal cracks in a natural gas distribution PE pipe.Laboratory experiments and a finite element model were planned to study the wave-crack interaction at different stages of axially oriented internal crack growth with a piezoceramic transducer-based setup arranged in a pitch-catch configuration.Mode dispersion analysis supplemented with preliminary experiments was performed to isolate the optimal inspection frequency,leading to the selection of the T(0,1)mode at 50-kHz for the investigation.A transmission index based on the energy of the T(0,1)mode was developed to trace the extent of simulated crack growth.The findings revealed an inverse linear correlation between the transmission index and the crack depth for crack growth beyond 20%crack depth.
文摘Endoscopic ultrasound-guided biliary drainage(EUS-BD)directs bile flow into the digestive tract and has been mostly used in patients with malignant biliary obstruction(MBO)where endoscopic retrograde cholangiopancreatography-guided biliary drainage was unsuccessful or was not feasible.Lumen apposing metal stents(LAMS)are deployed during EUS-BD,with the newer electrocautery-enhanced LAMS reducing procedure time and complication rates due to the inbuilt cautery at the catheter tip.EUS-BD with electrocautery-enhanced LAMS has high technical and clinical success rates for palliation of MBO,with bleeding,cholangitis,and stent occlusion being the most common adverse events.Recent studies have even suggested comparable efficacy between EUS-BD and endosc-opic retrograde cholangiopancreatography as the primary approach for distal MBO.In this editorial,we commented on the article by Peng et al published in the recent issue of the World Journal of Gastrointestinal Surgery in 2024.
基金supported by the National Natural Science Foundation of China(Nos.51921003,52275153)the Fundamental Research Funds for the Central Universities(No.NI2023001)+2 种基金the Research Fund of State Key Laboratory of Mechanics and Control for Aero-space Structures(No.MCAS-I-0423G01)the Fund of Pro-spective Layout of Scientific Research for Nanjing University of Aeronautics and Astronauticsthe Priority Academic Program Development of Jiangsu Higher Education Institu-tions of China.
文摘Carbon fiber-reinforced polymer(CFRP)is widely used in aerospace applications.This kind of material may face the threat of high-velocity impact in the process of dedicated service,and the relevant research mainly considers the impact resistance of the material,and lacks the high-velocity impact damage monitoring research of CFRP.To solve this problem,a real high-velocity impact damage experiment and structural health monitoring(SHM)method of CFRP plate based on piezoelectric guided wave is proposed.The results show that CFRP has obvious perforation damage and fiber breakage when high-velocity impact occurs.It is also proved that guided wave SHM technology can be effectively used in the monitoring of such damage,and the damage can be reflected by quantifying the signal changes and damage index(DI).It provides a reference for further research on guided wave structure monitoring of high/hyper-velocity impact damage of CFRP.
文摘Objective:To investigate the clinical effect of the guided bone regeneration(GBR)technique combined with temporary bridgework-guided gingival contouring in treating upper anterior tooth loss with labial bone defects.Methods:From July 2023 to April 2024,80 patients with upper anterior tooth loss and labial bone defects were admitted to the hospital and selected as evaluation samples.They were divided into an observation group(n=40)and a control group(n=40)using a numerical table lottery scheme.The control group received treatment with the GBR technique,while the observation group received treatment with the GBR technique combined with temporary bridges to guide gingival contouring.The two groups were compared in terms of clinical red aesthetic scores(PES),labial alveolar bone density,labial bone wall thickness,gingival papillae,gingival margin levels,and patient satisfaction.Results:The PES scores of patients in the observation group were higher than those in the control group after surgery(P<0.05).The bone density of the labial alveolar bone and the thickness of the labial bone wall in the observation group were higher than those in the control group.The levels of gingival papillae and gingival margins were lower in the observation group after surgery(P<0.05).Additionally,patient satisfaction in the observation group was higher than in the control group(P<0.05).Conclusion:The GBR technique combined with temporary bridge-guided gingival contouring for treating upper anterior tooth loss with labial bone defects can improve the aesthetic effect of gingival soft tissue,increase alveolar bone density and the thickness of the labial bone wall,and enhance patient satisfaction.This approach is suitable for widespread application in healthcare institutions.
文摘Objective: To evaluate the efficacy, feasibility and safety of contrast-enhanced CT-guided core biopsy of retroperitoneal masses. Materials and Methods: Contrast-enhanced CT-guided biopsy of retroperitoneal masses was performed in 26 patients. Histopathological diagnosis was obtained and accuracy was calculated. Two blinded radiologists determined feasibility of biopsy procedures on routine CT-guidance, and compared accessibility of target lesions using contrast-enhanced and non-contrast-enhanced CT. Results: Satisfactory samples were obtained in all 26 patients and pathological diagnosis was made in 24. Accuracy was 95.5%. Routine CT-guided biopsy punctures were not satisfaction in 4/26 patients, and contrast-enhanced CT scans rendered the target lesions more accessible in 16 patients. Conclusion: Contrast-enhanced CT-guided biopsy increases the feasibility of biopsy of retroperitoneal masses.
文摘Objectives: The aim of this study was to assess the safety and efficacy of percutaneous CT-guided drainage of gastric leaks post sleeve gastrectomy. Methods: For this single-center retrospective study, we reviewed the clinical data of 78 patients (44 men and 34 women with an average age of 34.6 ±10.5 years and a body mass index (BMI) of 45 kg/m2 ±3.2) that underwent percutaneous CT-guided drainage of gastric leaks due to sleeve gastrectomy from September 2011 to September 2018. The outcome measurements were technical and clinical success, complications, and the need for revisional surgery. Results: The technical success rate of drain insertion was 97.5% (76/78 patients). All of the patients (76/76 patients) exhibited early clinical and laboratory improvement, and no emergency surgery was required. However, six patients underwent revisional surgery after 3 - 5 months for non-healing gastric leaks/fistulas. One patient had a major complication of active bleeding due to arterial injury;this was managed by transcatheter coil embolization. All patients underwent endoluminal stent placement and received antimicrobial therapy and nutritional support. Conclusion: Percutaneous CT-guided drainage of gastric leaks after sleeve gastrectomy is a safe, effective, and minimally invasive alternative to surgery. This technique is in line with other conservative measures (endoluminal stent placement, antimicrobial therapy, and nutritional support), which heal most gastric leaks due to sleeve gastrectomy and prevent the need for revisional surgery.
文摘Objective: The purpose of this study is to evaluate the effectiveness and safety of CT-guided percutaneous drainage (CPD) in the management of deep neck abscesses. Factors associated with successful treatment in patients with DNA will be identified. Methods: We retrospectively studied 29 patients who presented to the department of otolaryngology with deep neck abscesses between April 2011 and April 2015. These 29 patients were managed with CPD after antibiotic therapy or needle aspiration failed. Data on patient demographics, location of infection, existing comorbidity, duration of hospitalization, treatment received, and complications were reviewed. Results: The average age of 29 patients, including 18 men and 11 women, was 56 years old. Abscess was found in parapharyngeal space (n = 16), submandibular space (n = 7), retropharyngeal space (n = 5) and pretracheal space (n = 1). The maximum transverse diameter of abscess ranged from 4.8 cm to 8.0 cm (mean 6.03 cm). Positive cultures were found in 24 cases and the most common pathogen found was Streptococcus viridans. Average hospital stay was 6.7 days. Deep neck abscesses were completely removed without residual in all patients. No one had complications and no one died during and after CPD. Conclusion: CPD is a safe and highly effective procedure for treating patients with deep neck abscesses who do not respond to antibiotics therapy. This technique can also provide reliable evidence on pathogens responsible for deep neck abscesses and help otolaryngologists choose effective treatment to achieve better clinical success rate. We recommend that most deep neck abscesses should be managed initially by CPD before resorting to open surgery.
文摘Purpose: To evaluate a new miniature optical navigation system for CT-guided liver interventions. Material and Methods: A two-center, prospective study was performed with four interventional radiologists. A total of 20 patients had CT-guided liver biopsy or ablation interventions utilizing the CT-Guide? navigation system (ActiViews Inc., Wakefield, MA) between July 2011 and December 2011. The navigation system consists of a self-adhesive patientsticker printed with coincident colored and radio-opaque reference markers, a miniature disposable video camera that clips on and off an interventional instrument, and software loaded on a computer to display the navigation information. The primary end point was the frequency of a satisfactory instrument position for the intended intervention. Results: The cohort consisted of 13 males and 7 females with an average age of 63.1 years (range of 38 to 80). Most of the patients, 70%, underwent CT-guided liver biopsy while the remainder had CT-guided ablation therapy. The average lesion size was 3.1 cm (range of 1.1 - 6.9 cm). All of the interventions, regardless of lesion size, met the primary end point of satisfactory instrument positioning. There were no device-related or unexpected adverse events recorded. Only one patient had a mild adverse event and it resolved without intervention. Conclusions: This study demonstrated the safety and effectiveness of the CT-Guide? navigation system for CT-guided liver interventions, for both biopsies and ablations. The targeting success rate for a satisfactory intervention was 100% with the system.
文摘Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (TRUS-SB) is the primary diagnostic method, prebiopsy multiparametric magnetic resonance imaging (mpMRI) is gaining popularity in identifying suspicious lesions. This study addresses the lack of comprehensive investigations into the efficacy of cognitive registration TRUS targeted biopsy (COG-TB) compared to conventional TRUS-SB, considering the resource limitations of the Malaysian healthcare system. Materials and Methods: A retrospective cohort study was conducted in two Malaysian healthcare facilities. 116 adult patients with a prostate-specific antigen (PSA) level of more than 4 ng/mL who underwent both COG-TB and TRUS-SB between October 2020 and March 2022 were included. Primary outcomes were cancer detection rate and histopathological outcomes, including Gleason score. Results: COG-TB showed a higher overall cancer detection rate (50%) compared to TRUS-SB (44%). Clinically significant cancer detection rates were similar between COG-TB and TRUS-SB (37.1%). Further analysis revealed that both COG-TB and TRUS-SB detected clinically significant cancer in 30.2% of patients, did not detect it in 56.0%, and had conflicting findings in 16 patients (p Conclusion: COG-TB and TRUS-SB have comparable detection rates for clinically significant prostate cancer, with COG-TB showing a higher tendency to detect insignificant prostate cancer. Further studies comparing these methods are warranted.