DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu...DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.展开更多
China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner indus...China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant.展开更多
HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in t...HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq.展开更多
In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart...In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV.展开更多
Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for prem...Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality.展开更多
Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step ...Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step in such a development, we have implemented a remote monitoring system of unitary air conditioners, using the manufacturing message specification (MMS). MMS is an OSI application protocol designed for the remote control and monitoring of real devices. The functions supported are those that an operator would do normally at the console of the unitary air conditioner. Due to the accomplishment of UMCS (Unitary air conditioner MMS Control System), there will be a leap of the application of MMS and the control technology of unitary air conditioner.展开更多
The performance loss of an approximately 3 dB signal-to-noise ratio is always paid with conventional differential detection compared to the related coherent detection. A new detection scheme consisting of two steps is...The performance loss of an approximately 3 dB signal-to-noise ratio is always paid with conventional differential detection compared to the related coherent detection. A new detection scheme consisting of two steps is proposed for the differential unitary space-time modulation (DUSTM) system. In the first step, the data sequence is estimated by conventional unitary space-time demodulation (DUSTD) and differentially encoded again to produce an initial estimate of the transmitted symbol stream. In the second step, the initial estimate of the symbol stream is utilized to initialize an expectation maximization (EM)-based iterative detector. In each iteration, the most recent detected symbol stream is employed to estimate the channel, which is then used to implement coherent sequence detection to refine the symbol stream. Simulation results show that the proposed detection scheme performs much better than the conventional DUSTD after several iterations.展开更多
提出了一种采用酉ESPRIT(Unitary-Estimation ofSignal Parameters via Rotational Invariant Technique,Unitary-ESPRIT)算法对目标的二维波达方向(Direction-of-Arrival,DOA)进行估计,接收信号模型为中心对称的平面阵。与二维MUSIC(Mu...提出了一种采用酉ESPRIT(Unitary-Estimation ofSignal Parameters via Rotational Invariant Technique,Unitary-ESPRIT)算法对目标的二维波达方向(Direction-of-Arrival,DOA)进行估计,接收信号模型为中心对称的平面阵。与二维MUSIC(Multiple Signal Classification)算法、二维求根MUSIC算法、二维ESPRIT算法不同的是,该算法将复矩阵运算转化为实矩阵计算,简化了运算复杂程度,并且目标的DOA估计精度也相应的得到提高,是一种比较高效的DOA估计算法。展开更多
Generally unitary solution to the system of martix equations over the quaternion field [X mA ns =B ns ,X nn C nt =D nt ] is considered. A necessary and sufficient condition for the existence o...Generally unitary solution to the system of martix equations over the quaternion field [X mA ns =B ns ,X nn C nt =D nt ] is considered. A necessary and sufficient condition for the existence of and the expression for the generally unitary solution of the system are derived.展开更多
We examine critically how tightly the density dependence of nuclear symmetry energy E_(sym)(q) is constrained by the universal equation of state of the unitary Fermi gas EUG(q) considering currently known uncertaintie...We examine critically how tightly the density dependence of nuclear symmetry energy E_(sym)(q) is constrained by the universal equation of state of the unitary Fermi gas EUG(q) considering currently known uncertainties of higher order parameters describing the density dependence of the equation of state of isospin asymmetric nuclear matter. We found that E_(UG)(q) does provide a useful lower boundary for the E_(sym)(q). However, it doesnot tightly constrain the correlation between the magnitude E_(sym)(q_0) and slope L unless the curvature K_(sym)of the symmetry energy at saturation density q_0 is more precisely known. The large uncertainty in the skewness parameters affects the E_(sym)(q_0) versus L correlation by the same almost as significantly as the uncertainty in K_(sym).展开更多
A family of authentication codes with arbitration is constructed from unitary geometry,the parameters and the probabilities of deceptions of the codes are also computed.In a special case a perfect authentication code ...A family of authentication codes with arbitration is constructed from unitary geometry,the parameters and the probabilities of deceptions of the codes are also computed.In a special case a perfect authentication code with arbitration is obtained.展开更多
Due to the scale invariance, the thermodynamic laws of strongly interacting limit unitary Fermi gas can be similar to those of non-interacting ideal gas. For example, the virial theorem between pressure and energy den...Due to the scale invariance, the thermodynamic laws of strongly interacting limit unitary Fermi gas can be similar to those of non-interacting ideal gas. For example, the virial theorem between pressure and energy density of the ideal gas P = 2E/aV is still satisfied by the unitary Fermi gas. This paper analyses the sound velocity of unitary Fermi gases with the quasi-linear approximation. For comparison, the sound velocities for the ideal Boltzmann, Bose and Fermi gas are also given. Quite interestingly, the sound velocity formula for the ideal non-interacting gas is found to be satisfied by the unitary Fermi gas in different temperature regions.展开更多
基金Supported by Program for Changjiang Scholars and Innovative Research Team in University,Ministry of Education of China(PCSIRT)
文摘DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
文摘China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant.
文摘HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq.
文摘In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV.
文摘Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality.
文摘Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step in such a development, we have implemented a remote monitoring system of unitary air conditioners, using the manufacturing message specification (MMS). MMS is an OSI application protocol designed for the remote control and monitoring of real devices. The functions supported are those that an operator would do normally at the console of the unitary air conditioner. Due to the accomplishment of UMCS (Unitary air conditioner MMS Control System), there will be a leap of the application of MMS and the control technology of unitary air conditioner.
基金The National Natural Science Foundation of China(No60572072,60496311)the National High Technology Research and Development Program of China (863Program) (No2006AA01Z264)+1 种基金the National Basic Research Program of China (973Program) (No2007CB310603)the PhD Programs Foundation of Ministry of Educa-tion of China (No20060286016)
文摘The performance loss of an approximately 3 dB signal-to-noise ratio is always paid with conventional differential detection compared to the related coherent detection. A new detection scheme consisting of two steps is proposed for the differential unitary space-time modulation (DUSTM) system. In the first step, the data sequence is estimated by conventional unitary space-time demodulation (DUSTD) and differentially encoded again to produce an initial estimate of the transmitted symbol stream. In the second step, the initial estimate of the symbol stream is utilized to initialize an expectation maximization (EM)-based iterative detector. In each iteration, the most recent detected symbol stream is employed to estimate the channel, which is then used to implement coherent sequence detection to refine the symbol stream. Simulation results show that the proposed detection scheme performs much better than the conventional DUSTD after several iterations.
文摘提出了一种采用酉ESPRIT(Unitary-Estimation ofSignal Parameters via Rotational Invariant Technique,Unitary-ESPRIT)算法对目标的二维波达方向(Direction-of-Arrival,DOA)进行估计,接收信号模型为中心对称的平面阵。与二维MUSIC(Multiple Signal Classification)算法、二维求根MUSIC算法、二维ESPRIT算法不同的是,该算法将复矩阵运算转化为实矩阵计算,简化了运算复杂程度,并且目标的DOA估计精度也相应的得到提高,是一种比较高效的DOA估计算法。
文摘Generally unitary solution to the system of martix equations over the quaternion field [X mA ns =B ns ,X nn C nt =D nt ] is considered. A necessary and sufficient condition for the existence of and the expression for the generally unitary solution of the system are derived.
基金supported in part by the China Scholarship Councilthe U.S.Department of Energy,Office of Science,under Award Number DE-SC0013702+7 种基金the CUSTIPEN(China-U.S.Theory Institute for Physics with Exotic Nuclei) under the US Department of Energy Grant No.DE-SC0009971the National Natural Science Foundation of China under Grant No.11320101004the Texas Advanced Computing Centersupported in part by the Major State Basic Research Development Program(973Program) of China under Contract Nos.2015CB856904 and 2014CB845401the National Natural Science Foundation of China under Grant Nos.11475243 and 11421505the ‘‘100-talent plan’’ of Shanghai Institute of Applied Physics under Grant Nos.Y290061011and Y526011011 from the Chinese Academy of Sciencesthe Shanghai Key Laboratory of Particle Physics and Cosmology under Grant No.15DZ2272100the Shanghai Pujiang Program under Grant No.13PJ1410600
文摘We examine critically how tightly the density dependence of nuclear symmetry energy E_(sym)(q) is constrained by the universal equation of state of the unitary Fermi gas EUG(q) considering currently known uncertainties of higher order parameters describing the density dependence of the equation of state of isospin asymmetric nuclear matter. We found that E_(UG)(q) does provide a useful lower boundary for the E_(sym)(q). However, it doesnot tightly constrain the correlation between the magnitude E_(sym)(q_0) and slope L unless the curvature K_(sym)of the symmetry energy at saturation density q_0 is more precisely known. The large uncertainty in the skewness parameters affects the E_(sym)(q_0) versus L correlation by the same almost as significantly as the uncertainty in K_(sym).
文摘A family of authentication codes with arbitration is constructed from unitary geometry,the parameters and the probabilities of deceptions of the codes are also computed.In a special case a perfect authentication code with arbitration is obtained.
基金supported by the National Natural Science Foundation of China (Grant No. 10875050)
文摘Due to the scale invariance, the thermodynamic laws of strongly interacting limit unitary Fermi gas can be similar to those of non-interacting ideal gas. For example, the virial theorem between pressure and energy density of the ideal gas P = 2E/aV is still satisfied by the unitary Fermi gas. This paper analyses the sound velocity of unitary Fermi gases with the quasi-linear approximation. For comparison, the sound velocities for the ideal Boltzmann, Bose and Fermi gas are also given. Quite interestingly, the sound velocity formula for the ideal non-interacting gas is found to be satisfied by the unitary Fermi gas in different temperature regions.