A bond coat for thermal barrier coating (TBC), NiCrAlY coating, is subjected to vac-uum heat treatment in order to remove internal stress before ceramic top coat is de-posited. The effect of vacuum heat treatment on t...A bond coat for thermal barrier coating (TBC), NiCrAlY coating, is subjected to vac-uum heat treatment in order to remove internal stress before ceramic top coat is de-posited. The effect of vacuum heat treatment on the oxidation behavior of the sputtered NiCrAlY coating has been investigated. The as-sputtered NiCrAlY coating consists of γ-Ni and b-NiAl phases. After vacuum heat treatment, the sputtered NiCrAlY coating mainly consists of γ'-Ni3Al, β-NiAl, γ-Ni, and trace of α-Al2O3 phases. The isothermal oxidation of sputtered NiCrAlY coating with and without vacuum heat treatment has been performed at 1000℃. It is shown that a-Al2O3 formed during vacuum heat treatment acts as nuclei for the formation of a-Al2O3, and the protective a-Al2O3 scale is formed more rapidly on the vacuum heat treated NiCrAlY coating than that formed on the untreated coating. Also the a-Al2O3 scale has a better adherence to the vacuum heat treated NiCrAlY coating. Therefore the vacuum heat treatment improves the oxidation resistance of sputtered NiCrAlY coating.展开更多
To prevent hydrogen-induced loss and achieve long-term effective parameters monitoring in harsh downhole environment,we proposed a Fabry-Perot sensor with vacuum sputter deposited carbon coating film,in which we emplo...To prevent hydrogen-induced loss and achieve long-term effective parameters monitoring in harsh downhole environment,we proposed a Fabry-Perot sensor with vacuum sputter deposited carbon coating film,in which we employed a deposition technology with a higher particle kinetic energy,closer substrate adhesion,and denser films,to deposit the coating film on the surface of the quartz capillary glass tube to protect the sensor from corrosion.The sensitivity and accuracy of the Fabry-Perot sensor with carbon film deposition can reach 369 nm/MPa and 0.02%FS,respectively.Meanwhile,the sensor has less hysteresis error and good pressure linearity of more than 0.99999 for repeatable pressure measurement.The downhole practice monitoring data indicated that this fiber-optic sensor exhibited excellent performance and the sputter deposited carbon coating can effectively decrease hydrogen loss.展开更多
基金The authors thank Prof.H. Y. Lou for sputtering NiCrAlY coating.
文摘A bond coat for thermal barrier coating (TBC), NiCrAlY coating, is subjected to vac-uum heat treatment in order to remove internal stress before ceramic top coat is de-posited. The effect of vacuum heat treatment on the oxidation behavior of the sputtered NiCrAlY coating has been investigated. The as-sputtered NiCrAlY coating consists of γ-Ni and b-NiAl phases. After vacuum heat treatment, the sputtered NiCrAlY coating mainly consists of γ'-Ni3Al, β-NiAl, γ-Ni, and trace of α-Al2O3 phases. The isothermal oxidation of sputtered NiCrAlY coating with and without vacuum heat treatment has been performed at 1000℃. It is shown that a-Al2O3 formed during vacuum heat treatment acts as nuclei for the formation of a-Al2O3, and the protective a-Al2O3 scale is formed more rapidly on the vacuum heat treated NiCrAlY coating than that formed on the untreated coating. Also the a-Al2O3 scale has a better adherence to the vacuum heat treated NiCrAlY coating. Therefore the vacuum heat treatment improves the oxidation resistance of sputtered NiCrAlY coating.
基金by the National Natural Science Foundation of China(No.61605101)the Natural Fund of Shandong Province(Nos.ZR2021MF127 and ZR2020LLZ010)the Peixin Fund of Qilu University of Technology(No.2022PX074)。
文摘To prevent hydrogen-induced loss and achieve long-term effective parameters monitoring in harsh downhole environment,we proposed a Fabry-Perot sensor with vacuum sputter deposited carbon coating film,in which we employed a deposition technology with a higher particle kinetic energy,closer substrate adhesion,and denser films,to deposit the coating film on the surface of the quartz capillary glass tube to protect the sensor from corrosion.The sensitivity and accuracy of the Fabry-Perot sensor with carbon film deposition can reach 369 nm/MPa and 0.02%FS,respectively.Meanwhile,the sensor has less hysteresis error and good pressure linearity of more than 0.99999 for repeatable pressure measurement.The downhole practice monitoring data indicated that this fiber-optic sensor exhibited excellent performance and the sputter deposited carbon coating can effectively decrease hydrogen loss.