期刊文献+
共找到13,495篇文章
< 1 2 250 >
每页显示 20 50 100
Is sentinel lymph node biopsy necessary for the patients diagnosed with breast ductal carcinoma in situ using core needle biopsy or vacuum-assisted biopsy as the initial diagnostic method? 被引量:4
1
作者 Xiaoyi Zhang Rui Wang +1 位作者 Zhiyong Wu Xueqing Jiang 《The Chinese-German Journal of Clinical Oncology》 CAS 2014年第11期509-514,共6页
Axillary lymph node status is one of the most important prognostic indicator of survival for breast cancer, especially in ductal carcinoma in situ (DCIS). The purpose of this study was to investigate whether sentine... Axillary lymph node status is one of the most important prognostic indicator of survival for breast cancer, especially in ductal carcinoma in situ (DCIS). The purpose of this study was to investigate whether sentinel lymph node biopsy (SLNB) should be performed in patients with an initial diagnosis of DCIS. Methods: A retrospective study was performed of 124 patients with an initial diagnosis of DCIS between March 2000 and June 2014. The patients were treated with either SLNB or axillary node dissection during the surgery, and we compared the clinicopathologic characteristics, image features, and immunohistochemical results. Results: Eighty-two patients (66.1%) had pure DCIS and 25 (20.2%) had DCIS with microinvasion (DCISM), 17 (13.7%) updated to invasive breast cancer (IBC). 115 patients (92.7%) underwent SLNB, among them, 70 patients (56.5%) underwent axillary node dissection. 3 of 115 patients (2.6%) had a positive sentinel lymph node, only 1 (1.4%) of 70 patients had axillary lymph node metastasis, in 84 patients (66.7%) who were diagnosed DCIS by core needle biopsy (CNB) and vacuum-assisted biopsy (VAB). 26 patients (31.0%) were upstaged into IBC or DCISM in the final histological diagnosis. The statistically significant factors predictive of underestimation were large tumor size, microcalcifications, comedo necrosis, positive Her-2 status, negative estrogen receptor status. Conclusion: The metastasis of sentinel lymph nodes in pure DCIS is very low, but the underestimation of invasive carcinoma in patients with an initial diagnosis of DCIS is an usual incident, especially in the cases when DCIS is diagnosed by CNB or VAB. Our findings suggest patients presenting with a preoperative diagnosis of DCIS associated with large tumor sizes, microcalcifications, comedo necrosis, positive Her-2 status, negative ER status are more likely to be DCISM and IBC in final diagnosis. SLNB should be performed in this part of patients. 展开更多
关键词 ductal carcinoma in situ (DCIS) breast cancer sentinel lymph node biopsy (SLNB) core needle biopsy (CNB) vacuum-assisted biopsy (VAB)
下载PDF
Diagnosis and excision of breast multi-focal lesions by ultrasound-guided vacuum-assisted biopsy:a comparative evaluation
2
作者 Tie-Qiang Bi1,Chang-Ling Ren2,Prakash Chaudhary1,Xin-Hua Liao1,Xiang-Ming Che1 1.Department of Surgery,the First Affiliated Hospital,Medical School of Xi’an Jiaotong University,Xi’an 710061 2.Department of Surgery,Laizhou People’s Hospital,Laizhou 261400,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第3期208-211,共4页
Objective To compare and evaluate the efficacy of diagnosis and excision for appropriately selected breast multi-focal lesions and solitary lesion by ultrasound-guided vacuum-assisted biopsy(UGVAB).Methods Among 392 a... Objective To compare and evaluate the efficacy of diagnosis and excision for appropriately selected breast multi-focal lesions and solitary lesion by ultrasound-guided vacuum-assisted biopsy(UGVAB).Methods Among 392 appropriately selected patients,187 patients with multi-focal lesions and 205 patients with solitary lesion were treated by the 8-gauge UGVAB from May 2007 to June 2009.All lesions were removed as completely as possible.The patients with benign pathology underwent physical and ultrasound examinations at one week and 6 months after procedure.Results During the procedure,only three patients had vasovagal syncope and twenty others complained of other intraoperative discomfort.An accurate pathological diagnosis was obtained in all lesions.There was no apparent false-negative result among the 696 lesions with benign pathology at a follow-up of 6 months after procedure.The rates of malignant or premalignant pathology,postoperative complications and residual lesions in patients with multi-focal lesions were higher than those in patients with solitary lesion.If each lesion was considered as a subject of study,there was no significant difference between the two groups.Conclusion UGVAB is an effective method for diagnosis and excision of appropriately selected breast multi-focal lesions and can be used routinely. 展开更多
关键词 vacuum-assisted biopsy ULTRASOUND-GUIDED breast multi-focal lesions
下载PDF
Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 11-gauge vacuum-assisted biopsy
3
作者 Lei Ye Liping Wang Youbin Deng 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第5期228-231,共4页
Objective: The objective of this study was to compare the underestimation rate of invasive carcinoma cases with ductal carcinoma in situ (DCIS) at percutaneous ultrasound-guided core biopsies of breast lesions betw... Objective: The objective of this study was to compare the underestimation rate of invasive carcinoma cases with ductal carcinoma in situ (DCIS) at percutaneous ultrasound-guided core biopsies of breast lesions between 14-gauge automated core needle biopsy (ACNB) and 11-gauge vacuum-assisted biopsy (VAB), and analyze the diagnostic advantages and insufficiencies in DCIS between this two methods, and to determine the relationship between the lesion type (masses or microcalcifications on radiological findings ) and DCIS underestimation rate. Methods: We collected 152 breast lesions which were diagnosed as DCIS by retrospectively reviewing data about ultrasound-guided biopsies of breast lesions (from February 2003 to July 2010). There were 98 lesions in 95 patients by 14-gauge ACNB, and 54 lesions in 52 patients by 11-gauge VAB (The system used in this study called Mammatome, MMT). The clinical and radiological findings were reviewed; meanwhile all the selected patients had histological results of the biopsies and follow-up surgeries which also achieved the reliable pathological results to compare with the biopsy results. The differences between two correlated histological results defined as underestimation, and the histological DCIS underestimation rates were compared between the two groups. According to the radiological characteristics, each group was classified into two subgroups (masses or micrecalcifications group), and the differences between subgroups were also analyzed. Results: The DCIS underestimation rate was 45.9% (45/98) for 14-gauge ACNB and 16.6% (9/54) for MMT. According to the lesion type on ultrasonography, DCIS underestimation was 31.0% (26/84) in masses (43.1% using ACNB and 12.1% using MMT; P = 0.003) and 42.6% (29/68) in microcalcifications (48.9% using ACNB and 23,8% using MMT; P = 0,036), Conclusion: The underestimation rate of invasive carcinoma in cases with DCIS at ultrasound-guided core biopsies is significantly higher for ACNB than for MMT. Furthermore, this difference does not alter among the two lesion types presented on ultrasonography. So ultrasound-guided VAB (MMT system) could be an effective and useful method for the diagnosis of DCIS lesions no matter what the lesion type is. 展开更多
关键词 ductal carcinoma in situ (DCIS) automated core needle biopsy (ACNB) vacuum-assisted biopsy (VAB) underestimation rate
下载PDF
Utility of an upright-type 11-gauge stereotactic vacuum-assisted biopsy device (Mammotome) for the diagnosis of breast microcalcifications 被引量:1
4
作者 Ming Yang Takanori Ishida +1 位作者 Motohiro Takeda Noriaki Ohuchi 《The Chinese-German Journal of Clinical Oncology》 CAS 2009年第10期567-571,共5页
Objective: The aim of this study was to evaluate the utility of an upright-type 11-gauge stereotactic vacuumassisted biopsy device (Mammotome) for the diagnosis of breast microcalcifications Methods: Between May 2001 ... Objective: The aim of this study was to evaluate the utility of an upright-type 11-gauge stereotactic vacuumassisted biopsy device (Mammotome) for the diagnosis of breast microcalcifications Methods: Between May 2001 and October 2005, 154 biopsies in 152 patients with microcalcifications were performed using the upright-type 11-gauge stereotactic vacuum-assisted biopsy device. Patients in whom this biopsy was diagnosed as carcinoma or a borderline lesion, had a subsequent surgical excision of the lesion. Histopathological and radiological features of the two specimens were then compared with each other. Results: Microcalcification was identified on specimen mammograms and microscopic slides in 97.4% of cases. Of 154 Mammotome biopsies 98 (63.6%) were benign, 51 (33.1%) were malignant, 3 (1.9%) showed atypical hyperplasia, and 2 (1.3%) were indeterminate, respectively. Of the 48 cases that received surgical excision, 6 of 36 ductal carcinomas in situ (16.7%) upstaged to invasive ductal carcinoma and 1 of 2 atypical ductal hyperplasias was upstaged to ductal carcinoma in situ. The positive predictive value of the 11-gauge Mammotome for the diagnosis of invasion in breast cancer was 100%. Linear calcification and pleomorphic calcification linear/segmental distribution was reliable indications of malignancy. The mean follow-up time of the benign lesions was 22 months, and without evidence of lesion growth. Complications included vasovagal reactions (6.3%), bleeding (0.6%) and hematoma (2.6%). Conclusion: The upright stereotactic 11-gauge Mammotome procedure is an effective and reliable method for the diagnosis of breast microcalcifications. It has minimal side effects. For lesions diagnosed as ADH or DCIS with the 11-gauge Mammotome, subsequent surgical excision should be performed. 展开更多
关键词 stereotactic vacuum assistanted biopsy breast cancer mammography MAMMOTOME MICROCALCIFICATION
下载PDF
Effects of diamond particle size on microstructure and properties of diamond/Al-12Si composites prepared by vacuum-assisted pressure infiltration
5
作者 Jia-ping Fu Can-xu Zhou +1 位作者 Guo-fa Mi Yuan Liu 《China Foundry》 SCIE EI CAS CSCD 2024年第4期360-368,共9页
Diamond/aluminium composites have attracted attention in the field of thermal management of electronic packaging for their excellent properties.In order to solve the interfacial problem between diamond and aluminium,a... Diamond/aluminium composites have attracted attention in the field of thermal management of electronic packaging for their excellent properties.In order to solve the interfacial problem between diamond and aluminium,a novel process combining pressure infiltration with vacuum-assisted technology was proposed to prepare diamond/aluminum composites.The effect of diamond particle size on the microstructure and properties of the diamond/Al-12Si composites was investigated.The results show that the diamond/Al-12Si composites exhibit high relative density and a uniform microstructure.Both thermal conductivity and coefficient of thermal expansion increase with increasing particle size,while the bending strength exhibits the opposite trend.When the average diamond particle size increases from 45μm to 425μm,the thermal conductivity of the composites increases from 455 W·m^(-1)·K^(-1)to 713 W·m^(-1)·K^(-1)and the coefficient of thermal expansion increases from 4.97×10^(-6)K^(-1)to 6.72×10^(-6)K^(-1),while the bending strength decreases from 353 MPa to 246 MPa.This research demonstrates that high-quality composites can be prepared by the vacuum-assisted pressure infiltration process and the thermal conductivity of the composites can be effectively improved by increasing the diamond particle size. 展开更多
关键词 diamond/aluminum composites thermal conductivity electronic packaging vacuum-assisted pressure infiltration
下载PDF
Clinical efficacy of endovascular revascularization combined with vacuum-assisted closure for the treatment of diabetic foot
6
作者 Feng-Rui Lei Xiao-Fei Shen +3 位作者 Chuang Zhang Xin-Qing Li Hao Zhuang Hong-Fei Sang 《World Journal of Diabetes》 SCIE 2024年第7期1499-1508,共10页
BACKGROUND The diabetic foot is a common cause of disability and death,and comorbid foot infections usually lead to prolonged hospitalization,high healthcare costs,and a significant increase in amputation rates.And mo... BACKGROUND The diabetic foot is a common cause of disability and death,and comorbid foot infections usually lead to prolonged hospitalization,high healthcare costs,and a significant increase in amputation rates.And most diabetic foot trauma is complicated by lower extremity arteriopathy,which becomes an independent risk factor for major amputation in diabetic foot patients.AIM To establish the efficacy and safety of endovascular revascularization(ER)combined with vacuum-assisted closure(VAC)for the treatment of diabetic foot.METHODS Clinical data were collected from 40 patients with diabetic foot admitted to the Second Affiliated Hospital of Soochow University from April 2018 to April 2022.Diabetic foot lesions were graded according to Wagner’s classification,and blood flow to the lower extremity was evaluated using the ankle-brachial index test and computerized tomography angiography of the lower extremity arteries.Continuous subcutaneous insulin infusion pumps were used to achieve glycemic control.Lower limb revascularization was facilitated by percutaneous transluminal balloon angioplasty(BA)or stenting.Wounds were cleaned by nibbling debridement.Wound granulation tissue growth was induced by VAC,and wound repair was performed by skin grafting or skin flap transplantation.RESULTS Of the 35 cases treated with lower limb revascularization,34 were successful with a revascularization success rate of 97%.Of these,6 cases underwent stenting after BA of the superficial femoral artery,and 1 received popliteal artery stent implantation.In the 25 cases treated with infrapopliteal artery revascularization,39 arteries were reconstructed,7 of which were treated by drug-coated BA and the remaining 32 with plain old BA.VAC was performed in 32 wounds.Twenty-four cases of skin grafting and 2 cases of skin flap transplantation were performed.Two patients underwent major amputations,whereas 17 had minor amputations,accounting for a success limb salvage rate of 95%.CONCLUSION ER in combination with VAC is a safe and effective treatment for diabetic foot that can significantly improve limb salvage rates.The use of VAC after ER simplifies and facilitates wound repair. 展开更多
关键词 Diabetic foot REVASCULARIZATION vacuum-assisted closure Balloon angioplasty Wound repair
下载PDF
New Wireless Handheld Ultrasound-Guided Vacuum-Assisted Breast Biopsy (VABB) Devices: An Important Innovation in Breast Diagnosis 被引量:1
7
作者 Silvia Bagnera Sebastiano Patania +2 位作者 Luisella Milanesio Giovanni Gatti Renzo Orlassino 《Open Journal of Radiology》 2013年第4期174-179,共6页
Vacuum-assisted breast biopsy (VABB) plays a fundamental role in the preoperative assessment of breast lesions pro- viding large histology samples that are useful to define diagnoses and biological parameters to guide... Vacuum-assisted breast biopsy (VABB) plays a fundamental role in the preoperative assessment of breast lesions pro- viding large histology samples that are useful to define diagnoses and biological parameters to guide treatment planning. This technique has been used in our institute since 2000 and two new wireless handheld ultrasound-guided VABB de- vices have been introduced since May 2012. In this report we analyze our experience with these revolutionary devices which are able to provide the option of single-insertion contiguous tissue samples respectively with a 13/14-gauge aperture. Our initial experience on 75 lesions shows that these devices are safe, fast, procedurally advantageous for operators and well accepted by patients. Finally VABB procedures can markedly reduce the need for surgical biopsy. 展开更多
关键词 BREAST biopsy vacuum-assisted BREAST biopsy ULTRASOUND-GUIDED HISTOLOGY biopsy
下载PDF
Circulating tumor DNA in liquid biopsy: Current diagnostic limitation 被引量:1
8
作者 Shi-Cai Liu 《World Journal of Gastroenterology》 SCIE CAS 2024年第15期2175-2178,共4页
With the rapid development of science and technology,cell-free DNA(cfDNA)is rapidly becoming an important biomarker for tumor diagnosis,monitoring and prognosis,and this cfDNA-based liquid biopsy technology has great ... With the rapid development of science and technology,cell-free DNA(cfDNA)is rapidly becoming an important biomarker for tumor diagnosis,monitoring and prognosis,and this cfDNA-based liquid biopsy technology has great potential to become an important part of precision medicine.cfDNA is the total amount of free DNA in the systemic circulation,including DNA fragments derived from tumor cells and all other somatic cells.Tumor cells release fragments of DNA into the bloodstream,and this source of cfDNA is called circulating tumor DNA(ctDNA).cfDNA detection has become a major focus in the field of tumor research in recent years,which provides a new opportunity for non-invasive diagnosis and prognosis of cancer.In this paper,we discuss the limitations of the study on the origin and dynamics analysis of ctDNA,and how to solve these problems in the future.Although the future faces major challenges,it also con-tains great potential. 展开更多
关键词 Cell-free DNA Circulating tumor DNA Liquid biopsy Cancer Diagnosis Prognosis
下载PDF
Emerging role of liquid biopsy in rat sarcoma virus mutated metastatic colorectal cancer:A case report 被引量:1
9
作者 João Gramaça Isabel Gomes Fernandes +4 位作者 Carolina Trabulo Joana Gonçalves Rita Gameiro dos Santos Adriano Baptista Idília Pina 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第1期234-243,共10页
BACKGROUND In patients with metastatic colorectal cancer(mCRC),the treatment options are limited and have been proved to be affected by rat sarcoma virus(RAS)mutational status.In RAS wild-type(wt)patients,the combinat... BACKGROUND In patients with metastatic colorectal cancer(mCRC),the treatment options are limited and have been proved to be affected by rat sarcoma virus(RAS)mutational status.In RAS wild-type(wt)patients,the combination of antiepidermal growth factor receptor(EGFR)monoclonal antibodies with chemotherapy(CT)is more effective than CT alone.On the other hand,RAS-mutated patients are not eligible for treatment with anti-EGFR antibodies.CASE SUMMARY Eleven patients with initially RAS-mutated mCRC were followed from diagnosis to May 2022.At the time of cell-free DNA determination,five patients had undergone one CT line,five patients had undergone two CT lines,and one patient had undergone three CT lines(all in combination with bevacizumab).At the second and third treatment lines[second line(2L),third line(3L)],patients with neo-RAS wt received a combination of CT and cetuximab.In neo-RAS wt patients treated with anti-EGFR,our findings indicated an increase in progression-free survival for both 2L and 3L(14.5 mo,P=0.119 and 3.9 mo,P=0.882,respectively).Regarding 2L overall survival,we registered a slight increase in neo-RAS wt patients treated with anti-EGFR(33.6 mo vs 32.4 mo,P=0.385).At data cut-off,two patients were still alive:A RAS-mutated patient undergoing 3L treatment and a neo-RAS wt patient who received 2L treatment with anti-EGFR(ongoing).CONCLUSION Our case series demonstrated that monitoring RAS mutations in mCRC by liquid biopsy may provide an additional treatment line for neo-RAS wt patients. 展开更多
关键词 Metastatic colorectal cancer Rat sarcoma virus mutational status Liquid biopsy Rat sarcoma virus wild-type Neo-rat sarcoma virus wild-type Anti-epidermal growth factor receptor therapy Case report
下载PDF
Effectiveness of Histopathological Examination of Ultrasound-guided Puncture Biopsy Samples for Diagnosis of Extrapulmonary Tuberculosis
10
作者 GU Wen Fei SHI Xia +5 位作者 MA Xin YU Jun Lei XU Jin Chuan QIAN Cheng Cheng HU Zhi Dong ZHANG Hui 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第2期170-177,共8页
Objective To evaluate the diagnostic value of histopathological examination of ultrasound-guided puncture biopsy samples in extrapulmonary tuberculosis(EPTB).Methods This study was conducted at the Shanghai Public Hea... Objective To evaluate the diagnostic value of histopathological examination of ultrasound-guided puncture biopsy samples in extrapulmonary tuberculosis(EPTB).Methods This study was conducted at the Shanghai Public Health Clinical Center.A total of 115patients underwent ultrasound-guided puncture biopsy,followed by MGIT 960 culture(culture),smear,Gene Xpert MTB/RIF(Xpert),and histopathological examination.These assays were performed to evaluate their effectiveness in diagnosing EPTB in comparison to two different diagnostic criteria:liquid culture and composite reference standard(CRS).Results When CRS was used as the reference standard,the sensitivity and specificity of culture,smear,Xpert,and histopathological examination were(44.83%,89.29%),(51.72%,89.29%),(70.11%,96.43%),and(85.06%,82.14%),respectively.Based on liquid culture tests,the sensitivity and specificity of smear,Xpert,and pathological examination were(66.67%,72.60%),(83.33%,63.01%),and(92.86%,45.21%),respectively.Histopathological examination showed the highest sensitivity but lowest specificity.Further,we found that the combination of Xpert and histopathological examination showed a sensitivity of 90.80%and a specificity of 89.29%.Conclusion Ultrasound-guided puncture sampling is safe and effective for the diagnosis of EPTB.Compared with culture,smear,and Xpert,histopathological examination showed higher sensitivity but lower specificity.The combination of histopathology with Xpert showed the best performance characteristics. 展开更多
关键词 Extrapulmonary tuberculosis DIAGNOSIS biopsy Histopathological examination Puncture samples
下载PDF
Percutaneous ultrasound-guided coaxial core needle biopsy for the diagnosis of multiple splenic lesions: A case report
11
作者 Sha-Hong Pu Wu-Yong-Ga Bao +2 位作者 Zhen-Peng Jiang Rui Yang Qiang Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期616-621,共6页
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide... BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue. 展开更多
关键词 SPLEEN Splenic disease Ultrasound biopsy Ultrasound-guided coaxial core needle biopsy Case report
下载PDF
Risk evaluation for diabetic retinopathy in Chinese renalbiopsied type 2 diabetes mellitus patients
12
作者 Shou-Yue Huang Qi-Wei Hu +2 位作者 Ze-Wei Zhang Ping-Yan Shen Qiong Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1283-1291,共9页
AIM:To investigate diabetic retinopathy(DR)prevalence in Chinese renal-biopsied type 2 diabetes mellitus(T2DM)patients with kidney dysfunction,and to further evaluate its relationship with diabetic nephropathy(DN)inci... AIM:To investigate diabetic retinopathy(DR)prevalence in Chinese renal-biopsied type 2 diabetes mellitus(T2DM)patients with kidney dysfunction,and to further evaluate its relationship with diabetic nephropathy(DN)incidence and the risk factors for DR development in this population.METHODS:A total of 84 renal-biopsied T2DM patients were included.Fundus and imaging examinations were employed for DR diagnosis.Demographic information and clinical measures along with renal histopathology were analyzed for comparisons between the DR and non-DR groups.Risk factors on DR development were analyzed with multiple logistic regression.RESULTS:DR prevalence was 50%in total.The incidences of DN,non-diabetic renal disease(NDRD)and mixed-type pathology were 47.6%,19.0%and 33.3%in the DR group respectively,while 11.9%,83.3%and 4.8%in the non-DR group.Systolic blood pressure,ratio of urinary albumin to creatine ratio,urinary albumin,24-hours urinary protein,the incidence and severity of DN histopathology were found statistically increased in the DR group.Multiple logistic regression analysis showed histopathological DN incidence significantly increased the risk of DR development[odds ratio(OR)=21.664,95%confidential interval(CI)5.588 to 83.991,P<0.001 for DN,and OR=45.475,95%CI 6.949 to 297.611,P<0.001 for mixed-type,respectively,in reference to (NDRD)],wherein DN severity positively correlated.CONCLUSION:Renal histopathological evidence indicates DN incidence and severity increases the risk of DR development in Chinese T2DM patients inexperienced of regular fundus examinations. 展开更多
关键词 diabetic retinopathy diabetic nephropathy vision threatens renal biopsy vision screening
下载PDF
Liquid biopsy for gastric cancer:Techniques,applications,and future directions
13
作者 Cristina Díaz del Arco M Jesús Fernández Aceñero Luis Ortega Medina 《World Journal of Gastroenterology》 SCIE CAS 2024年第12期1680-1705,共26页
After the study of circulating tumor cells in blood through liquid biopsy(LB),this technique has evolved to encompass the analysis of multiple materials originating from the tumor,such as nucleic acids,extracellular v... After the study of circulating tumor cells in blood through liquid biopsy(LB),this technique has evolved to encompass the analysis of multiple materials originating from the tumor,such as nucleic acids,extracellular vesicles,tumor-educated platelets,and other metabolites.Additionally,research has extended to include the examination of samples other than blood or plasma,such as saliva,gastric juice,urine,or stool.LB techniques are diverse,intricate,and variable.They must be highly sensitive,and pre-analytical,patient,and tumor-related factors significantly influence the detection threshold,diagnostic method selection,and potential results.Consequently,the implementation of LB in clinical practice still faces several challenges.The potential applications of LB range from early cancer detection to guiding targeted therapy or immunotherapy in both early and advanced cancer cases,monitoring treatment response,early identification of relapses,or assessing patient risk.On the other hand,gastric cancer(GC)is a disease often diagnosed at advanced stages.Despite recent advances in molecular understanding,the currently available treatment options have not substantially improved the prognosis for many of these patients.The application of LB in GC could be highly valuable as a non-invasive method for early diagnosis and for enhancing the management and outcomes of these patients.In this comprehensive review,from a pathologist’s perspective,we provide an overview of the main options available in LB,delve into the fundamental principles of the most studied techniques,explore the potential utility of LB application in the context of GC,and address the obstacles that need to be overcome in the future to make this innovative technique a game-changer in cancer diagnosis and treatment within clinical practice. 展开更多
关键词 Liquid biopsy Gastric cancer Circulating tumor cells Cell-free DNA Circulating tumor DNA MOLECULAR
下载PDF
Changes in macrophage infiltration and podocyte injury in lupus nephritis patients with repeated renal biopsy: Report of three cases
14
作者 Shi-Yuan Liu Hao Chen +8 位作者 Li-Jia He Chun-Kai Huang Pu Wang Zhang-Ru Rui Jue Wu Yang Yuan Yue Zhang Wen-Ju Wang Xiao-Dan Wang 《World Journal of Clinical Cases》 SCIE 2024年第1期188-195,共8页
BACKGROUND In this study,we retrospectively analysed macrophage infiltration and podocyte injury in three patients with diffuse proliferative lupus nephritis(LN)who un-derwent repeated renal biopsy.CASE SUMMARY Clinic... BACKGROUND In this study,we retrospectively analysed macrophage infiltration and podocyte injury in three patients with diffuse proliferative lupus nephritis(LN)who un-derwent repeated renal biopsy.CASE SUMMARY Clinical data of three diffuse proliferative LN patients with different pathological characteristics(case 1 was LN IV-G(A),case 2 was LN IV-G(A)+V,and case 3 was LN IV-G(A)+thrombotic microangiopathy)were reviewed.All patients underwent repeated renal biopsies 6 mo later,and renal biopsy specimens were studied.Macrophage infiltration was assessed by CD68 expression detected by immunohistochemical staining,and an immunofluorescence assay was used to detect podocin expression to assess podocyte damage.After treatment,Case 1 changed to LN III-(A),Case 2 remained as type V LN lesions,and Case 3,which changed to LN IV-S(A),had the worst prognosis.We observed reduced macro-phage infiltration after therapy.However,two of the patients with active lesions after treatment still showed macrophage infiltration in the renal interstitium.Before treatment,the three patients showed discontinuous expression of podocin.Notably,the integrity of podocin was restored after treatment in Case 1.CONCLUSION It may be possible to reverse podocyte damage and decrease the infiltrating ma-crophages in LN patients through effective treatment. 展开更多
关键词 Lupus nephritis MACROPHAGE PODOCYTE Repeat renal biopsy Thrombotic microangiopathy Case report
下载PDF
Evaluating the efficacy of percutaneous puncture biopsy guided by contrast-enhanced ultrasound for peripheral pulmonary lesions
15
作者 Xiao Jiang Jun Chen +8 位作者 Fang-Fang Gu Zhong-Rong Li Yu-Shan Song Jing-Jing Long Shu-Zhen Zhang Ting-Ting Xu Yong-Jun Tang Ji-Ying Gu Xiang-Ming Fang 《World Journal of Clinical Cases》 SCIE 2024年第19期3791-3799,共9页
BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for t... BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions. 展开更多
关键词 Contrast-enhanced ultrasound Peripheral lung lesions Ultrasound guidance biopsy Peripheral thoracic focal lesions
下载PDF
Integrating Transformer and Bidirectional Long Short-Term Memory for Intelligent Breast Cancer Detection from Histopathology Biopsy Images
16
作者 Prasanalakshmi Balaji Omar Alqahtani +2 位作者 Sangita Babu Mousmi Ajay Chaurasia Shanmugapriya Prakasam 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第10期443-458,共16页
Breast cancer is a significant threat to the global population,affecting not only women but also a threat to the entire population.With recent advancements in digital pathology,Eosin and hematoxylin images provide enh... Breast cancer is a significant threat to the global population,affecting not only women but also a threat to the entire population.With recent advancements in digital pathology,Eosin and hematoxylin images provide enhanced clarity in examiningmicroscopic features of breast tissues based on their staining properties.Early cancer detection facilitates the quickening of the therapeutic process,thereby increasing survival rates.The analysis made by medical professionals,especially pathologists,is time-consuming and challenging,and there arises a need for automated breast cancer detection systems.The upcoming artificial intelligence platforms,especially deep learning models,play an important role in image diagnosis and prediction.Initially,the histopathology biopsy images are taken from standard data sources.Further,the gathered images are given as input to the Multi-Scale Dilated Vision Transformer,where the essential features are acquired.Subsequently,the features are subjected to the Bidirectional Long Short-Term Memory(Bi-LSTM)for classifying the breast cancer disorder.The efficacy of the model is evaluated using divergent metrics.When compared with other methods,the proposed work reveals that it offers impressive results for detection. 展开更多
关键词 Bidirectional long short-term memory breast cancer detection feature extraction histopathology biopsy images multi-scale dilated vision transformer
下载PDF
Core needle biopsy for thyroid nodules assessment-a new horizon?
17
作者 David D Dolidze Serghei Covantsev +3 位作者 Grigorii M Chechenin Natalia V Pichugina Anastasia V Bedina Anna Bumbu 《World Journal of Clinical Oncology》 2024年第5期580-586,共7页
Ultrasound-guided fine-needle aspiration is the standard for evaluating thyroid nodules with a high safety profile and a relatively low number of non-diagnostic cytological findings.Nevertheless,this diagnostic method... Ultrasound-guided fine-needle aspiration is the standard for evaluating thyroid nodules with a high safety profile and a relatively low number of non-diagnostic cytological findings.Nevertheless,this diagnostic method traditionally has its weak points.Several diagnostic categories such as BethesdaⅠ,ⅢandⅣare not reliable for thyroid carcinoma risk assessment.Recent advancements in a core needle biopsy made it possible to use this tool as a new method for thyroid nodules evaluation.The main feature of this method is the use of thin needles(18-21G)and guns with an automatic trigger mechanism.The histological material collected with the use of a core needle biopsy is usually superior to cytological.Therefore,the core needle biopsy can be used as a complementary technique to a standard fine needle aspiration in difficult and dubious cases of thyroid neoplasia with uncertain malignant potential. 展开更多
关键词 Core-needle biopsy THYROID Follicular tumor Fine-needle aspiration Thyroid cancer
下载PDF
Comparison of Cognitive Registration Transrectal Ultrasound-Guided Targeted Biopsy of Prostate to Systematic 12-Core Biopsy: A Retrospective, Multicentre Study
18
作者 Kevin Chang Yue Wei Lee Say Bob +4 位作者 Devindran Manoharan Liong Men Long Teoh Sze Yong Teo Rui Ling Chua Zi Wei 《Open Journal of Urology》 2024年第7期381-390,共10页
Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (... Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (TRUS-SB) is the primary diagnostic method, prebiopsy multiparametric magnetic resonance imaging (mpMRI) is gaining popularity in identifying suspicious lesions. This study addresses the lack of comprehensive investigations into the efficacy of cognitive registration TRUS targeted biopsy (COG-TB) compared to conventional TRUS-SB, considering the resource limitations of the Malaysian healthcare system. Materials and Methods: A retrospective cohort study was conducted in two Malaysian healthcare facilities. 116 adult patients with a prostate-specific antigen (PSA) level of more than 4 ng/mL who underwent both COG-TB and TRUS-SB between October 2020 and March 2022 were included. Primary outcomes were cancer detection rate and histopathological outcomes, including Gleason score. Results: COG-TB showed a higher overall cancer detection rate (50%) compared to TRUS-SB (44%). Clinically significant cancer detection rates were similar between COG-TB and TRUS-SB (37.1%). Further analysis revealed that both COG-TB and TRUS-SB detected clinically significant cancer in 30.2% of patients, did not detect it in 56.0%, and had conflicting findings in 16 patients (p Conclusion: COG-TB and TRUS-SB have comparable detection rates for clinically significant prostate cancer, with COG-TB showing a higher tendency to detect insignificant prostate cancer. Further studies comparing these methods are warranted. 展开更多
关键词 Prostate Cancer Multiparametric MRI Targeted biopsy Cognitive Fusion Transrectal Ultrasound-Guided biopsy
下载PDF
Liver biopsy in the post-hepatitis C virus era in Japan
19
作者 Yoshihiro Ikura Takako Okubo Yasuhiro Sakai 《World Journal of Gastroenterology》 SCIE CAS 2024年第14期1949-1957,共9页
In Japan,liver biopsies were previously crucial in evaluating the severity of hepatitis caused by the hepatitis C virus(HCV)and diagnosing HCV-related hepatocellular carcinoma(HCC).However,due to the development of ef... In Japan,liver biopsies were previously crucial in evaluating the severity of hepatitis caused by the hepatitis C virus(HCV)and diagnosing HCV-related hepatocellular carcinoma(HCC).However,due to the development of effective antiviral treatments and advanced imaging,the necessity for biopsies has significantly decreased.This change has resulted in fewer chances for diagnosing liver disease,causing many general pathologists to feel less confident in making liver biopsy diagnoses.This article provides a comprehensive overview of the challenges and potential solutions related to liver biopsies in Japan.First,it highlights the importance of considering steatotic liver diseases as independent conditions that can coexist with other liver diseases due to their increasing prevalence.Second,it emphasizes the need to avoid hasty assumptions of HCC in nodular lesions,because clinically diagnosable HCCs are not targets for biopsy.Third,the importance of diagnosing hepatic immune-related adverse events caused by immune checkpoint inhibitors is increasing due to the anticipated widespread use of these drugs.In conclusion,pathologists should be attuned to the changing landscape of liver diseases and approach liver biopsies with care and attention to detail. 展开更多
关键词 Liver biopsy ALTERATION Post-hepatitis C virus era Steatotic liver disease Hepatic tumors Immune checkpoint inhibitors
下载PDF
Phase II Clinical Study of Three-Dimensional Printed Coplanar Template Combined with CT-Guided Percutaneous Core Needle Biopsy of Pulmonary Nodules in Elderly Patients
20
作者 Wangti Xie Yu Wu +11 位作者 Xiaoshan Cheng Jianbing Hu Fang Wen Jia Xiao Pan Luo Yuqi Su Xiang Yao Jianlong Fang Grong Dan Xianggan Huang Dunqian Liu Jie Weng 《Journal of Biosciences and Medicines》 2024年第7期325-336,共12页
Background: As the population age structure gradually ages, more and more elderly people were found to have pulmonary nodules during physical examinations. Most elderly people had underlying diseases such as heart, lu... Background: As the population age structure gradually ages, more and more elderly people were found to have pulmonary nodules during physical examinations. Most elderly people had underlying diseases such as heart, lung, brain and blood vessels and cannot tolerate surgery. Computed tomography (CT)-guided percutaneous core needle biopsy (CNB) was the first choice for pathological diagnosis and subsequent targeted drugs, immune drugs or ablation treatment. CT-guided percutaneous CNB requires clinicians with rich CNB experience to ensure high CNB accuracy, but it was easy to cause complications such as pneumothorax and hemorrhage. Three-dimensional (3D) printing coplanar template (PCT) combined with CT-guided percutaneous pulmonary CNB biopsy has been used in clinical practice, but there was no prospective, randomized controlled study. Methods: Elderly patients with lung nodules admitted to the Department of Oncology of our hospital from January 2019 to January 2023 were selected. A total of 225 elderly patients were screened, and 30 patients were included after screening. They were randomly divided into experimental group (Group A: 30 cases) and control group (Group B: 30 cases). Group A was given 3D-PCT combined with CT-guided percutaneous pulmonary CNB biopsy, Group B underwent CT-guided percutaneous pulmonary CNB. The primary outcome measure of this study was the accuracy of diagnostic CNB, and the secondary outcome measures were CNB time, number of CNB needles, number of pathological tissues and complications. Results: The diagnostic accuracy of group A and group B was 96.67% and 76.67%, respectively (P = 0.026). There were statistical differences between group A and group B in average CNB time (P = 0.001), number of CNB (1 vs more than 1, P = 0.029), and pathological tissue obtained by CNB (3 vs 1, P = 0.040). There was no statistical difference in the incidence of pneumothorax and hemorrhage between the two groups (P > 0.05). Conclusions: 3D-PCT combined with CT-guided percutaneous CNB can improve the puncture accuracy of elderly patients, shorten the puncture time, reduce the number of punctures, and increase the amount of puncture pathological tissue, without increasing pneumothorax and hemorrhage complications. We look forward to verifying this in a phase III randomized controlled clinical study. . 展开更多
关键词 Pulmonary Nodules Elderly patients Three-Dimensional (3D) Printed Coplanar Template (PCT) Core Needle biopsy (CNB) Computed Tomography (CT)
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部