期刊文献+
共找到2,899篇文章
< 1 2 145 >
每页显示 20 50 100
An Environment‑Tolerant Ion‑Conducting Double‑Network Composite Hydrogel for High‑Performance Flexible Electronic Devices
1
作者 Wenchao Zhao Haifeng Zhou +3 位作者 Wenkang Li Manlin Chen Min Zhou Long Zhao 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第5期352-369,共18页
High-performance ion-conducting hydrogels(ICHs)are vital for developing flexible electronic devices.However,the robustness and ion-conducting behavior of ICHs deteriorate at extreme tempera-tures,hampering their use i... High-performance ion-conducting hydrogels(ICHs)are vital for developing flexible electronic devices.However,the robustness and ion-conducting behavior of ICHs deteriorate at extreme tempera-tures,hampering their use in soft electronics.To resolve these issues,a method involving freeze–thawing and ionizing radiation technology is reported herein for synthesizing a novel double-network(DN)ICH based on a poly(ionic liquid)/MXene/poly(vinyl alcohol)(PMP DN ICH)system.The well-designed ICH exhibits outstanding ionic conductivity(63.89 mS cm^(-1) at 25℃),excellent temperature resistance(-60–80℃),prolonged stability(30 d at ambient temperature),high oxidation resist-ance,remarkable antibacterial activity,decent mechanical performance,and adhesion.Additionally,the ICH performs effectively in a flexible wireless strain sensor,thermal sensor,all-solid-state supercapacitor,and single-electrode triboelectric nanogenerator,thereby highlighting its viability in constructing soft electronic devices.The highly integrated gel structure endows these flexible electronic devices with stable,reliable signal output performance.In particular,the all-solid-state supercapacitor containing the PMP DN ICH electrolyte exhibits a high areal specific capacitance of 253.38 mF cm^(-2)(current density,1 mA cm^(-2))and excellent environmental adaptability.This study paves the way for the design and fabrication of high-performance mul-tifunctional/flexible ICHs for wearable sensing,energy-storage,and energy-harvesting applications. 展开更多
关键词 Ionic liquids Double-network hydrogels Temperature tolerance Multifunctionality Flexible electronic devices
下载PDF
The Advent of Wide Bandgap Green-Synthesized Copper Zinc Tin Sulfide Nanoparticles for Applications in Optical and Electronic Devices
2
作者 Opeyemi S. Akanbi Haruna A. Usman +8 位作者 Gbemi F. Abass Kehinde E. Oni Akinsanmi S. Ige Bola P. Odunaro Idowu J. Ojo Julius A. Oladejo Halimat O. Ajani Adnan Musa Joshua Ajao 《Journal of Materials Science and Chemical Engineering》 CAS 2023年第3期22-33,共12页
Power-electronic devices are widely used in various applications, such as voltage and frequency control for transmitting and converting electric power. As these devices are becoming increasingly important, there is a ... Power-electronic devices are widely used in various applications, such as voltage and frequency control for transmitting and converting electric power. As these devices are becoming increasingly important, there is a need to reduce their losses and improve their performance to reduce electric power consumption. Current power semiconductor devices, such as inverters, are made of silicon (Si), but the performance of these Si power devices is reaching its limit due to physical properties and energy bandgap. To address this issue, recent developments in wide bandgap (WBG) semiconductor materials, such as silicon carbide (SiC) and gallium nitride (GaN), offer the potential for a new generation of power semiconductor devices that can perform significantly better than silicon-based devices. In this research, a green synthesized copper-zinc-tin-sulfide (CZTS) nanoparticle is proposed as a new WBG semiconductor material that could be used for optical and electronic devices. Its synthesis, consisting of the production methods and materials used, is discussed. The characterization is also discussed, and further research is recommended in the later sections to enable the continual advancement of this technology. 展开更多
关键词 Wide Bandgap Semiconductor SEMICONDUCTOR electronic device Power device Optical device CZTS
下载PDF
Pushing the Electrochemical Performance Limits of Polypyrrole Toward Stable Microelectronic Devices
3
作者 Muhammad Tahir Liang He +6 位作者 Lihong Li Yawei Cao Xiaoxia Yu Zehua Lu Xiaoqiao Liao Zeyu Ma Yanlin Song 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第4期58-75,共18页
Conducting polymers have achieved remarkable attentions owing to their exclusive characteristics,for instance,electrical conductivity,high ionic conductivity,visual transparency,and mechanical tractability.Surface and... Conducting polymers have achieved remarkable attentions owing to their exclusive characteristics,for instance,electrical conductivity,high ionic conductivity,visual transparency,and mechanical tractability.Surface and nanostructure engineering of conjugated conducting polymers offers an exceptional pathway to facilitate their implementation in a variety of scientific claims,comprising energy storage and production devices,flexible and wearable optoelectronic devices.A two-step tactic to assemble high-performance polypyrrole(PPy)-based microsupercapacitor(MSC)is utilized by transforming the current collectors to suppress structural pulverization and increase the adhesion of PPy,and then electrochemical co-deposition of PPy-CNT nanostructures on rGO@Au current collectors is performed.The resulting fine patterned MSC conveyed a high areal capacitance of 65.9 mF cm^(−2)(at a current density of 0.1 mA cm^(−2)),an exceptional cycling performance of retaining 79%capacitance after 10,000 charge/discharge cycles at 5 mA cm^(−2).Benefiting from the intermediate graphene,current collector free PPy-CNT@rGO flexible MSC is produced by a facile transfer method on a flexible substrate,which delivered an areal capacitance of 70.25 mF cm^(−2) at 0.1 mA cm^(−2) and retained 46%of the initial capacitance at a current density of 1.0 mA cm^(−2).The flexible MSC is utilized as a skin compatible capacitive micro-strain sensor with excellent electromechanochemical characteristics. 展开更多
关键词 Microsupercapacitor Skin-compatible device Strain sensor Flexible electronics
下载PDF
Preface to Special Issue on Towards High Performance Ga_(2)O_(3) Electronics: Epitaxial Growth and Power Devices(Ⅰ)
4
作者 Genquan Han Shibing Long +2 位作者 Yuhao Zhang Yibo Wang Zhongming Wei 《Journal of Semiconductors》 EI CAS CSCD 2023年第6期4-6,共3页
There is currently great optimism within the electronics community that gallium oxide(Ga_(2)O_(3)) ultra-wide bandgap semiconductors have unprecedented prospects for eventually revolutionizing a rich variety of power ... There is currently great optimism within the electronics community that gallium oxide(Ga_(2)O_(3)) ultra-wide bandgap semiconductors have unprecedented prospects for eventually revolutionizing a rich variety of power electronic applications. Specially, benefiting from its ultra-high bandgap of around 4.8 eV, it is expected that the emerging Ga_(2)O_(3) technology would offer an exciting platform to deliver massively enhanced device performance for power electronics and even completely new applications. 展开更多
关键词 Epitaxial Growth and Power devices Preface to Special Issue on Towards High Performance Ga_(2)O_(3)electronics POWER
下载PDF
Viologen-based flexible electrochromic devices
5
作者 Wenwen Wu Shanlu Guo +3 位作者 Jing Bian Xingyu He Haizeng Li Jianmin Li 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第6期453-470,I0012,共19页
Electrochromic technology has gained significant attention in various fields such as displays,smart windows,biomedical monitoring,military camouflage,human-machine interaction,and electronic skin due to its ability to... Electrochromic technology has gained significant attention in various fields such as displays,smart windows,biomedical monitoring,military camouflage,human-machine interaction,and electronic skin due to its ability to provide reversible and fast color changes under applied voltage.With the rapid development and increasing demand for flexible electronics,flexible electrochromic devices(FECDs)that offer smarter and more controllable light modulation hold great promise for practical applications.The electrochromic material(ECM)undergoing color changes during the electrochemical reactions is one of the key components in electrochromic devices.Among the ECMs,viologens,a family of organic small molecules with 1,1'-disubstituted-4,4'-dipyridinium salts,have garnered extensive research interest,due to their well-reversible redox reactions,excellent electron acceptance ability,and the ability to produce multiple colors.Notably,viologen-based FECDs demonstrate color changes in the liquid or semisolid electrolyte layer,eliminating the need for two solid electrodes and thus simplifying the device structure.Consequently,viologens offer significant potential for the development of FECDs with high optical contrast,fast response speed,and excellent stability.This review aims to provide a comprehensive overview of the progress and perspectives of viologen-based FECDs.It begins by summarizing the typical structure and recent exciting developments in viologen-based FECDs,along with their advantages and disadvantages.Furthermore,the review discusses recent advancements in FECDs with additional functionalities such as sensing,photochromism,and energy storage.Finally,the remaining challenges and potential research directions for the future of viologen-based FECDs are addressed. 展开更多
关键词 Flexible electrochromic devices Optical modulation VIOLOGENS Flexible electronics Multifunctional devices ELECTROCHROMISM
下载PDF
Advances in Wireless,Batteryless,Implantable Electronics for Real‑Time,Continuous Physiological Monitoring
6
作者 Hyeonseok Kim Bruno Rigo +2 位作者 Gabriella Wong Yoon Jae Lee Woon‑Hong Yeo 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期254-302,共49页
This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design co... This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design considerations,such as biological constraints,energy sourcing,and wireless communication,are discussed in achieving the desired performance of the devices and enhanced interface with human tissues.In addition,we review the recent achievements in materials used for developing implantable systems,emphasizing their importance in achieving multi-functionalities,biocompatibility,and hemocompatibility.The wireless,batteryless devices offer minimally invasive device insertion to the body,enabling portable health monitoring and advanced disease diagnosis.Lastly,we summarize the most recent practical applications of advanced implantable devices for human health care,highlighting their potential for immediate commercialization and clinical uses. 展开更多
关键词 Implantable electronics Biomedical systems Batteryless devices Wireless electronics Physiological signal monitoring
下载PDF
Highly Elastic,Bioresorbable Polymeric Materials for Stretchable,Transient Electronic Systems
7
作者 Jeong‑Woong Shin Dong‑Je Kim +12 位作者 Tae‑Min Jang Won Bae Han Joong Hoon Lee Gwan‑Jin Ko Seung Min Yang Kaveti Rajaram Sungkeun Han Heeseok Kang Jun Hyeon Lim Chan‑Hwi Eom Amay J.Bandodkar Hanul Min Suk‑Won Hwang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第6期1-13,共13页
Substrates or encapsulants in soft and stretchable formats are key components for transient,bioresorbable electronic systems;however,elastomeric polymers with desired mechanical and biochemical properties are very lim... Substrates or encapsulants in soft and stretchable formats are key components for transient,bioresorbable electronic systems;however,elastomeric polymers with desired mechanical and biochemical properties are very limited compared to nontransient counterparts.Here,we introduce a bioresorbable elastomer,poly(glycolide-co-ε-caprolactone)(PGCL),that contains excellent material properties including high elongation-at-break(<1300%),resilience and toughness,and tunable dissolution behaviors.Exploitation of PGCLs as polymer matrices,in combination with conducing polymers,yields stretchable,conductive composites for degradable interconnects,sensors,and actuators,which can reliably function under external strains.Integration of device components with wireless modules demonstrates elastic,transient electronic suture system with on-demand drug delivery for rapid recovery of postsurgical wounds in soft,time-dynamic tissues. 展开更多
关键词 Biodegradable elastomer Conductive polymer composites Biomedical device Transient electronics
下载PDF
Progress of Proximity Sensors for Potential Applications in Electronic Skins
8
作者 Runnan Zou Yanhong Tong +3 位作者 Jiayi Liu Jing Sun Da Xian Qingxin Tang 《Transactions of Tianjin University》 EI CAS 2024年第1期40-62,共23页
Recently,electronic skins and fl exible wearable devices have been developed for widespread applications in medical monitoring,artifi cial intelligence,human–machine interaction,and artifi cial prosthetics.Flexible p... Recently,electronic skins and fl exible wearable devices have been developed for widespread applications in medical monitoring,artifi cial intelligence,human–machine interaction,and artifi cial prosthetics.Flexible proximity sensors can accurately perceive external objects without contact,introducing a new way to achieve an ultrasensitive perception of objects.This article reviews the progress of fl exible capacitive proximity sensors,fl exible triboelectric proximity sensors,and fl exible gate-enhanced proximity sensors,focusing on their applications in the electronic skin fi eld.Herein,their working mechanism,materials,preparation methods,and research progress are discussed in detail.Finally,we summarize the future challenges in developing fl exible proximity sensors. 展开更多
关键词 Capacitive proximity sensors Triboelectric proximity sensors Gate-enhanced proximity sensors Flexible wearable devices electronic skins
下载PDF
New skin closure system facilitates wound healing after cardiovascular implantable electronic device surgery 被引量:4
9
作者 Elia De Maria 《World Journal of Clinical Cases》 SCIE 2015年第8期675-677,共3页
The manuscript describes the efficacy of a new skin closure system(Zip Line?) for wound closure after pacemaker/implantable cardioverter defibrillator surgery. The system is particularly useful when wound healingis di... The manuscript describes the efficacy of a new skin closure system(Zip Line?) for wound closure after pacemaker/implantable cardioverter defibrillator surgery. The system is particularly useful when wound healingis difficult with traditional methods and in patients at high risk for surgical site infections(SSIs). This skin closure option is easy and quick to apply and remove, and produces excellent cosmetic results. Although it is associated with a minimal expense upcharge, the benefits, including the potential for decrease in SSI, make it attractive and worth considering for skin closure in device patients, particularly those at increased risk of complications. 展开更多
关键词 CARDIOVASCULAR IMPLANTABLE electronic device infection Surgical WOUND Skin CLOSURE SYSTEM
下载PDF
Graphene applications in electronic and optoelectronic devices and circuits 被引量:2
10
作者 吴华强 令狐昌洋 +1 位作者 吕宏鸣 钱鹤 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第9期101-110,共10页
Recent progress of research for graphene applications in electronic and optoelectronic devices is reviewed, and recent developments in circuits based on graphene devices are summarized. The bandgap-mobility tradeoff i... Recent progress of research for graphene applications in electronic and optoelectronic devices is reviewed, and recent developments in circuits based on graphene devices are summarized. The bandgap-mobility tradeoff inevitably constrains the application of graphene for the conventional field-effect transistor (FET) devices in digital applications. However, this shortcoming has not dampened the enthusiasm of the research community toward graphene electronics. Aside from high mobility, graphene offers numerous other amazing electrical, optical, thermal, and mechanical properties that continually motivate innovations. 展开更多
关键词 GRAPHENE electronic device optoelectronic device CIRCUIT
下载PDF
Optimized cardiac magnetic resonance imaging inversion recovery sequence for metal artifact reduction and accurate myocardial scar assessment in patients with cardiac implantable electronic devices 被引量:2
11
作者 El-Sayed H Ibrahim Mason Runge +6 位作者 Jadranka Stojanovska Prachi Agarwal Maryam Ghadimi-Mahani Anil Attili Thomas Chenevert Chiel den Harder Frank Bogun 《World Journal of Radiology》 CAS 2018年第9期100-107,共8页
Late gadolinium enhancement(LGE) cardiovascular magnetic resonance(CMR) is the gold standard for imaging myocardial viability.An important application of LGE CMR is the assessment of the location and extent of the myo... Late gadolinium enhancement(LGE) cardiovascular magnetic resonance(CMR) is the gold standard for imaging myocardial viability.An important application of LGE CMR is the assessment of the location and extent of the myocardial scar in patients with ventricular tachycardia(VT), which allows for more accurate identification of the ablation targets.However, a large percentage of patients with VT have cardiac implantable electronic devices(CIEDs), which is a relative contraindication for cardiac magnetic resonance imaging due to safety and image artifact concerns.Previous studies showed that these patients can be safely scanned on 1.5 T scanners provided that an adequate imaging protocol is adopted.Nevertheless, imaging patients with a CIED result in metal artifacts due to the strong frequency off-resonance effects near the device; therefore, the spins in the surrounding myocardium are not completely inverted, and thus give rise to hyperintensity artifacts.These artifacts obscure the myocardial scar tissue and limit the ability to study the correlation between the myocardial scar structure and the electro-anatomical map during catheter ablation.In this study, we developed a modified inversion recovery technique to alleviate the CIED-induced metal artifacts and improve the diagnostic image quality of LGE images in patients with CIEDs without increasing scan time or requiring additional hardware.The developed technique was tested in phantom experiments and in vivo scans, which showed its capability for suppressing the hyperintensity artifacts without compromising myocardium nulling in the resulting LGE images. 展开更多
关键词 Magnetic resonance IMAGING Heart LATE GADOLINIUM enhancement VIABILITY IMAGING Inversion recovery CARDIAC IMPLANTABLE electronic devices
下载PDF
Experimental Research of Electronic Devices Thermal Control Using Metallic Phase Change Materials 被引量:1
12
作者 Ai-Gang Pan Jun-Biao Wang +1 位作者 Xian-Jie Zhang Xiao-Bao Cao 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第2期113-121,共9页
A Phase-change thermal control unit( PTCU) filled with metallic phase change material( PCM) Bismuth alloy for electric devices thermal protection was developed and investigated experimentally. The PTCU filled with PCM... A Phase-change thermal control unit( PTCU) filled with metallic phase change material( PCM) Bismuth alloy for electric devices thermal protection was developed and investigated experimentally. The PTCU filled with PCM was designed and manufactured. Resistance heating components( RCHs) produced 1 W,3 W, 5 W,7W,and 10 W for simulating heat generation of electronic devices. At various heating power levels,the performance of PTCU were tested during heating period and one duty cycle period. The experimental results show that the PTCU delays RCH reaching the maximum operating temperature. Also,a numerical model was developed to enable interpretation of experimental results and to perform parametric studies. The results confirmed that the PTCU is suitable for electric devices thermal control. 展开更多
关键词 bismuth alloy metallic phase change materials thermal control electronic device
下载PDF
Flexible energy storage devices for wearable bioelectronics 被引量:1
13
作者 Xiaohao Ma Zhengfan Jiang Yuanjing Lin 《Journal of Semiconductors》 EI CAS CSCD 2021年第10期71-83,共13页
With the growing market of wearable devices for smart sensing and personalized healthcare applications,energy storage devices that ensure stable power supply and can be constructed in flexible platforms have attracted... With the growing market of wearable devices for smart sensing and personalized healthcare applications,energy storage devices that ensure stable power supply and can be constructed in flexible platforms have attracted tremendous research interests.A variety of active materials and fabrication strategies of flexible energy storage devices have been intensively studied in recent years,especially for integrated self-powered systems and biosensing.A series of materials and applications for flexible energy storage devices have been studied in recent years.In this review,the commonly adopted fabrication methods of flexible energy storage devices are introduced.Besides,recent advances in integrating these energy devices into flexible self-powered systems are presented.Furthermore,the applications of flexible energy storage devices for biosensing are summarized.Finally,the prospects and challenges of the self-powered sensing system for wearable electronics are discussed. 展开更多
关键词 flexible electronics energy storage devices self-powered systems wearable bioelectronics
下载PDF
Electrochemical Properties of Polypyrrole-Coated Microelectrode Array and the Fabrication of Polypyrrole-Based Microelectronic Devices 被引量:2
14
作者 CAI Chen-xin,JU Huang-xian and CHEN Hong-yuan (Department of Chemistry,Nanjing University,Nanjing,210093) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1995年第2期163-169,共7页
Conducting polymers have been studied extensively. An interesting property of the conducting polymer is that the conductivity of some polymers, such as polypyrrolc, polyaniline, poly(3-methylthiophene) etc. , is affec... Conducting polymers have been studied extensively. An interesting property of the conducting polymer is that the conductivity of some polymers, such as polypyrrolc, polyaniline, poly(3-methylthiophene) etc. , is affected by the voltage applied to them. For polypyrrole, the oxidized state is an electronic conductor and the reduced state is essentially insulating. Using this property, one can fabricate the polymer-based electronic devices. Experimental results of Pickun 展开更多
关键词 Microelectrode Microeiectrode array Chemically modified electrode Polymer-based electronic devices Polypyrrole
下载PDF
The gender difference of utilization of cardiac implantable electronic device in China: data from Arrhythmia Interventional Therapy Data Registry 被引量:3
15
作者 Ruo-Han CHEN Ke-Ping CHEN +10 位作者 Wei HUA Jing XU Lin CHEN Yang-Gang SU Xi SU Jian-Gang ZOU Ji YAN Jing-Feng WANG Bao-Peng TANG Mei-Xiang XIANG Shu ZHANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第4期310-314,共5页
BackgroundCardiac 可植入的电子设备(CIED ) 极大地改进病人的幸存和生活质量。然而,关于这些设备的利用和利益有性差别。在这张未来的 CIED 注册表,我们试图在中国从 14 个省在 China.MethodsTwenty 中心在 CIED 利用估价性差别在... BackgroundCardiac 可植入的电子设备(CIED ) 极大地改进病人的幸存和生活质量。然而,关于这些设备的利用和利益有性差别。在这张未来的 CIED 注册表,我们试图在中国从 14 个省在 China.MethodsTwenty 中心在 CIED 利用估价性差别在我们的登记学习被包括。在在 2015 年 1 月和 2016 年 12 月之间的这二十个中心经历了 CIED 培植的所有病人是 8570 个病人全部的 included.ResultsA 在基线队被注册,包括 7203 心律调整器, 664 个可植入的心脏的使用高压脉冲来消减心脏(ICD ) 植入并且 703 心脏的再同步治疗设备(CRT/D ) 。完全, 4117 (48.0%) CIED 病人是女性的,并且超过 59% 心律调整器病人是女性的,但是女人们仅仅说明在这张注册表的三分之一 ICD 或 CRT/D 培植。在心律调整器和 ICD 指示的性之间有重要差别。女性是更可能的由于病了的湾穴症候群(SSS ) 收到了一个心律调整器(63.9% 对 51.0% , P < 0.001 ) 。收到 ICD 的女病人由于心脏的离子隧道疾病是更可能的(29.2% 对 4.2% , P < 0.001 ) 。在女病人的双房间的心律调整器的利用的百分比比男性显著地高(85.3% 对 81.1% , P < 0.001 ) 。但是男病人更多半被接待心脏的再同步治疗有使用高压脉冲来消减心脏的设备比女性(56.5% 对 41.9% , P = 0.001 ) 。在心律调整器病人,男性是更可能的有结构心疾病(31.3% 对 28.0% , P = 0.002 ) 。在 ICD 病人,男病人是更可能的有 ischemic 心疾病(48.2% 对 29.2% , P < 0.001 ) 。女人的吝啬的年龄在 CRT/D 培植的时候比男人旧(P = 0.014 ) 。 Nonischemic 心肌症(70.9%)是在经历了 CRT/D 的治疗的病人的最普通的病原学,不管男性或 female.ConclusionsIn 真实世界的背景,女性确实有不同传染病学, pathophysiology 和许多心脏的节奏混乱的临床的表示什么时候与相比男性,并且所有这些因素可以影响 CIED 培植的利用。但是它另外文化、社会经济的特征可以在这明显的辨别起一个作用的可能性。 展开更多
关键词 电子设备 治疗设备 心脏 心律 植入 中国 高压脉冲 调整器
下载PDF
Healthcare electronic skin devices
16
作者 Quan Yuan Zhong Ma +1 位作者 Sheng Li Lijia Pan 《Journal of Semiconductors》 EI CAS CSCD 2019年第3期7-8,共2页
Electronic skin(e-skin),a kind of flexible sensor arrays and system that mimic the properties and sensing functions of human skin,represents a new paradigm of sensing and control(Fig.1).The noun of'skin electronic... Electronic skin(e-skin),a kind of flexible sensor arrays and system that mimic the properties and sensing functions of human skin,represents a new paradigm of sensing and control(Fig.1).The noun of'skin electronics'made its debut in the Sensitive Skin Workshop organized jointly by the National Science Foundation and Defense Advanced Research Projects Agency of USA in October 1999 in Arlington. 展开更多
关键词 In FLEXIBLE Healthcare electronic SKIN deviceS
下载PDF
Comparison of Two Electronic Root Canal Length Measurement Devices: The Differences between Ratio Two Impedance Frequencies and Multi Frequencies
17
作者 Endang Suprastiwi Ratna Meidyawati 《Open Journal of Stomatology》 2014年第5期263-267,共5页
Accuracy electronic root canal length measurement devices were important for root canal treatment. Aim: To evaluate and compare accuracy of the two electronic root canal length measurement devices;two frequencies impe... Accuracy electronic root canal length measurement devices were important for root canal treatment. Aim: To evaluate and compare accuracy of the two electronic root canal length measurement devices;two frequencies impedance ratio and multi frequencies. Methods: Forty anterior teeth were sectioned on their cervical area. All samples were measured root canal length by radiographic. On the second phase, all the samples were measured by two frequencies impedance ratio and multi frequencies electronic devices. In the final phase, the teeth were split vertically and actual lengths were measured. All measurement by radiographic and electronic method was subtracted with actual length. Statistical analysis was performed using Chi-square and the Kolmogorov-Smirnov test. Results: Accuracy of the two frequencies impedance ratio 50% and multi frequencies 47.5%. No statistical significance between two frequencies impedance ratio and multi frequencies. Conclusions: There is no difference between ratio two impedance frequencies and multi frequencies. 展开更多
关键词 electronic Root CANAL MEASUREMENT deviceS
下载PDF
Hitachi Electronic Devices拓展Camstar Electronics Suite^(TM)的应用,以管理其迅速增长的产能
18
《半导体技术》 CAS CSCD 北大核心 2008年第11期1002-1002,共1页
关键词 electronicS HITACHI deviceS 应用 管理 产能 冷阴极荧光灯 ar公司
下载PDF
A Discrete Multi‑Objective Artificial Bee Colony Algorithm for a Real‑World Electronic Device Testing Machine Allocation Problem
19
作者 Jin Xie Xinyu Li Liang Gao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第6期136-150,共15页
With the continuous development of science and technology,electronic devices have begun to enter all aspects of human life,becoming increasingly closely related to human life.Users have higher quality requirements for... With the continuous development of science and technology,electronic devices have begun to enter all aspects of human life,becoming increasingly closely related to human life.Users have higher quality requirements for electronic devices.Electronic device testing has gradually become an irreplaceable engineering process in modern manufacturing enterprises to guarantee the quality of products while preventing inferior products from entering the market.Considering the large output of electronic devices,improving the testing efficiency while reducing the testing cost has become an urgent problem to be solved.This study investigates the electronic device testing machine allocation problem(EDTMAP),aiming to improve the production of electronic devices and reduce the scheduling distance among testing machines through reasonable machine allocation.First,a mathematical model was formulated for the EDTMAP to maximize both production and the scheduling distance among testing machines.Second,we developed a discrete multi-objective artificial bee colony(DMOABC)algorithm to solve EDTMAP.A crossover operator and local search operator were designed to improve the exploration and exploitation of the algorithm,respectively.Numerical experiments were conducted to evaluate the performance of the proposed algorithm.The experimental results demonstrate the superiority of the proposed algorithm compared with the non-dominated sorting genetic algorithm II(NSGA-II)and strength Pareto evolutionary algorithm 2(SPEA2).Finally,the mathematical model and DMOABC algorithm were applied to a real-world factory that tests radio-frequency modules.The results verify that our method can significantly improve production and reduce the scheduling distance among testing machines. 展开更多
关键词 electronic device Machine allocation Multi-objective optimization Artificial bee colony algorithm
下载PDF
Depression, Anxiety, Stress and Their Association with the Use of Electronic Devices among Adolescents during the COVID-19 Pandemic
20
作者 Ahmad Y.Alqassim Mohamed S.Mahfouz +7 位作者 Mohammed M.Hakami Abdullah A.Al Faqih Ahmad A.Shugairi Malek R.Alsanosy Ahmed Y.Rayyani AbdulAziz Y.Albrraq Mohammed A.Muaddi Abdullah A.Alharbi 《International Journal of Mental Health Promotion》 2022年第2期251-262,共12页
Background:Adolescence is a critical,multifactorial developmental phase.With the current pandemic of COVID-19,excessive using of electronic devices is a public health concern.The aim of this study is to investigate th... Background:Adolescence is a critical,multifactorial developmental phase.With the current pandemic of COVID-19,excessive using of electronic devices is a public health concern.The aim of this study is to investigate the relation-ship between depression and the use of electronic devices among secondary school children in Jazan,Saudi Arabia during the COVID-19 pandemic.Materials and Methods:The study is an observational,cross-sectional study.Data was collected using an anonymous online survey instrument.including the Depression Anxiety Stress Scale.Results:A total of 427 participants were included in the study.The prevalence of depression,anxiety,and stress in our study was 14.55%,12.01%,and 15.55%,respectively.For the hours spent on electronic devices,13.6%of participants spent 1–4 h,43.6%spent 5–9 h,and 42.9%spent 10 h or more.86.7%reported an increase in their use of electronic devices during COVID-19.The regression analysis revealed that the increase of Videogame Addiction Scale for Chil-dren is significantly associated with an increase in Depression,Anxiety,and Stress scores(p-value<0.05 for all).Conclusion:Electronic device use is a challenging issue among Saudi adolescents,and it has been associated with a negative impact on participants’mental well-being.The study found a positive correlation between electronic device use and increased prevalence of mental health issues.We also found significantly increased use of electronic device during the COVID-19 lockdown;hence,more mental issues were reported.It is obvious that electronic device use needs to be more controlled among adolescents.This can be achieved by involving those who are in this age group in other activities,like sports,which can reduce the time they spend on electronic device. 展开更多
关键词 COVID-19 DEPRESSION electronic devices adolescents public health environmental health
下载PDF
上一页 1 2 145 下一页 到第