A lithium(Li)vapour layer was formed around a flowing liquid Li limiter to shield against the plasma incident power and reduce limiter heat flux in the EAST tokamak.The results revealed that after a plasma operation o...A lithium(Li)vapour layer was formed around a flowing liquid Li limiter to shield against the plasma incident power and reduce limiter heat flux in the EAST tokamak.The results revealed that after a plasma operation of a few seconds,the layer became clear,which indicated a strong Li emission with a decrease in the limiter surface temperature.This emission resulted in a dense vapour around the limiter,and Li ions moved along the magnetic fleld to form a green shielding layer on the limiter.The plasma heat flux loaded on the limiter,measured by the probe installed on the limiter,was approximately 52%lower than that detected by a fast-reciprocating probe at the same radial position without the limiter in EAST.Additionally,approximately 42%of the parallel heat flux was dissipated directly with the enhanced Li radiation in the discharge with the liquid metal infused trenches(LIMIT)limiter.This observation revealed that the Li vapour layer exhibited an excellent shielding effect to liquid Li on plasma heat flux,which is a possible beneflt of liquid-plasma-facing components in future fusion devices.展开更多
Refrigeration plays a significant role across various aspects of human life and consumes substantial amounts of electrical energy.The rapid advancement of green cooling technology presents numerous solar-powered refri...Refrigeration plays a significant role across various aspects of human life and consumes substantial amounts of electrical energy.The rapid advancement of green cooling technology presents numerous solar-powered refrigeration systems as viable alternatives to traditional refrigeration equipment.Exergy analysis is a key in identifying actual thermodynamic losses and improving the environmental and economic efficiency of refrigeration systems.In this study exergy analyze has been conducted for a solar-powered vapor compression refrigeration(SP-VCR)system in the region of Gharda颽(Southern Algeria)utilizing R1234ze(E)fluid as an eco-friendly substitute for R134a refrigerant.A MATLAB-based numerical model was developed to evaluate losses in different system components and the exergy efficiency of the SP-VCR system.Furthermore,a parametric study was carriedout to analyze the impact of various operating conditions on the system’s exergy destruction and efficiency.The obtained results revealed that,for both refrigerants,the compressor exhibited the highest exergy destruction,followed by the condenser,expansion valve,and evaporator.However,the system using R1234ze(E)demonstrated lower irreversibility compared to that using R134a refrigerant.The improvements made with R1234ze are 71.95%for the compressor,39.13%for the condenser,15.38%for the expansion valve,5%for the evaporator,and 54.76%for the overall system,which confirm the potential of R1234ze(E)as a promising alternative to R134a for cooling applications.展开更多
Abstract--Vapor compression refrigeration cycle (VCC) system is a high dimensional coupling thermodynamic system for which the controller design is a great challenge. In this paper, a model predictive control based ...Abstract--Vapor compression refrigeration cycle (VCC) system is a high dimensional coupling thermodynamic system for which the controller design is a great challenge. In this paper, a model predictive control based energy efficient control strategy which aims at maximizing the system efficiency is proposed. Firstly, according to the mass and energy conservation law, an analysis on the nonlinear relationship between superheat and cooling load is carried out, which can produce the maximal effect on the system performance. Then a model predictive control (MPC) based controller is developed for tracking the calculated setting curve of superheat degree and pressure difference based on model identified from data which can be obtained from an experimental rig. The proposed control strategy maximizes the coefficient of performance (COP) which depends on operating conditions, in the meantime, it meets the changing demands of cooling capacity. The effectiveness of the control performance is validated on the experimental rig. Index Terms--Cooling load, model predictive control (MPC), superheat, vapor compression refrigeration cycle (VCC).展开更多
Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electri...Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption.展开更多
Tellurium thin films were prepared by the chemical vapor deposition method. The structure, surface morphology and optical properties of the Te thin films were analyzed by powder X-ray diffraction, scanning electron mi...Tellurium thin films were prepared by the chemical vapor deposition method. The structure, surface morphology and optical properties of the Te thin films were analyzed by powder X-ray diffraction, scanning electron microscopy, FTIR transmission, UV/VIS/NIR transmission and reflectance. The results show that the films structural and optical properties are influenced by many factors such as film thickness, crystallite size and substrate temperature. The films as thick as 111?133 nm have high IR transmission across the full 8?13 μm band and highly blocking in the solar spectral region elsewhere, which indicates that Te films thickness in this region can be used as good solar radiation shields in radiative cooling devices.展开更多
High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-per...High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.展开更多
基金funded by the National Key Research and Development Program of China(No.2017YFE0301100)National Natural Science Foundation of China(Nos.11905138,11905148 and 11905254)+2 种基金the U.S.Dept.of Energy contract DE-AC02-09CH11466 and grant DESC0016553Users with Excellence Program of Hefei Science Center CAS(No.2020HSC-UE010)Interdisciplinary and Collaborative Teams of CAS。
文摘A lithium(Li)vapour layer was formed around a flowing liquid Li limiter to shield against the plasma incident power and reduce limiter heat flux in the EAST tokamak.The results revealed that after a plasma operation of a few seconds,the layer became clear,which indicated a strong Li emission with a decrease in the limiter surface temperature.This emission resulted in a dense vapour around the limiter,and Li ions moved along the magnetic fleld to form a green shielding layer on the limiter.The plasma heat flux loaded on the limiter,measured by the probe installed on the limiter,was approximately 52%lower than that detected by a fast-reciprocating probe at the same radial position without the limiter in EAST.Additionally,approximately 42%of the parallel heat flux was dissipated directly with the enhanced Li radiation in the discharge with the liquid metal infused trenches(LIMIT)limiter.This observation revealed that the Li vapour layer exhibited an excellent shielding effect to liquid Li on plasma heat flux,which is a possible beneflt of liquid-plasma-facing components in future fusion devices.
文摘Refrigeration plays a significant role across various aspects of human life and consumes substantial amounts of electrical energy.The rapid advancement of green cooling technology presents numerous solar-powered refrigeration systems as viable alternatives to traditional refrigeration equipment.Exergy analysis is a key in identifying actual thermodynamic losses and improving the environmental and economic efficiency of refrigeration systems.In this study exergy analyze has been conducted for a solar-powered vapor compression refrigeration(SP-VCR)system in the region of Gharda颽(Southern Algeria)utilizing R1234ze(E)fluid as an eco-friendly substitute for R134a refrigerant.A MATLAB-based numerical model was developed to evaluate losses in different system components and the exergy efficiency of the SP-VCR system.Furthermore,a parametric study was carriedout to analyze the impact of various operating conditions on the system’s exergy destruction and efficiency.The obtained results revealed that,for both refrigerants,the compressor exhibited the highest exergy destruction,followed by the condenser,expansion valve,and evaporator.However,the system using R1234ze(E)demonstrated lower irreversibility compared to that using R134a refrigerant.The improvements made with R1234ze are 71.95%for the compressor,39.13%for the condenser,15.38%for the expansion valve,5%for the evaporator,and 54.76%for the overall system,which confirm the potential of R1234ze(E)as a promising alternative to R134a for cooling applications.
基金supported by the National Natural Science Foundation of China(61233004,61221003,61374109,61473184,61703223,61703238)the National Basic Research Program of China(973 Program)(2013CB035500)+1 种基金Shandong Provincial Natural Science Foundation of China(ZR2017BF014,ZR2017MF017)the National Research Foundation of Singapore(NRF-2011,NRF-CRP001-090)
文摘Abstract--Vapor compression refrigeration cycle (VCC) system is a high dimensional coupling thermodynamic system for which the controller design is a great challenge. In this paper, a model predictive control based energy efficient control strategy which aims at maximizing the system efficiency is proposed. Firstly, according to the mass and energy conservation law, an analysis on the nonlinear relationship between superheat and cooling load is carried out, which can produce the maximal effect on the system performance. Then a model predictive control (MPC) based controller is developed for tracking the calculated setting curve of superheat degree and pressure difference based on model identified from data which can be obtained from an experimental rig. The proposed control strategy maximizes the coefficient of performance (COP) which depends on operating conditions, in the meantime, it meets the changing demands of cooling capacity. The effectiveness of the control performance is validated on the experimental rig. Index Terms--Cooling load, model predictive control (MPC), superheat, vapor compression refrigeration cycle (VCC).
基金This work was supported by the National Key Research and Development Program of China(No.2017YFB0903201)the Science and Technology Project of China Southern Power Grid(No.GDKJXM20172171).
文摘Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption.
基金Project(50204001) supported by the National Natural Science Foundation of China
文摘Tellurium thin films were prepared by the chemical vapor deposition method. The structure, surface morphology and optical properties of the Te thin films were analyzed by powder X-ray diffraction, scanning electron microscopy, FTIR transmission, UV/VIS/NIR transmission and reflectance. The results show that the films structural and optical properties are influenced by many factors such as film thickness, crystallite size and substrate temperature. The films as thick as 111?133 nm have high IR transmission across the full 8?13 μm band and highly blocking in the solar spectral region elsewhere, which indicates that Te films thickness in this region can be used as good solar radiation shields in radiative cooling devices.
文摘High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.