This paper investigates the effect and transmission mechanism of air pollution on urbanization based on data from China’s 107 cities during 2005–2018.In order to identify the impact of air pollution on China’s urba...This paper investigates the effect and transmission mechanism of air pollution on urbanization based on data from China’s 107 cities during 2005–2018.In order to identify the impact of air pollution on China’s urbanization,we utilized night light data to represent the level of urbanization and used temperature inversion as an instrumental variable to mitigate endogeneity within the two-stage least squares framework.The results suggest that air pollution significantly slowed China’s urbanization process with economic growth acting as the transmission mechanism.The heterogeneity analyses revealed that air pollution had a greater negative impact on urbanization in northern regions than that in southern regions,and a greater negative impact in resource-oriented cities than that in non-resource-based cities.We also find that air pollution was to the detriment of urbanization in larger cities,which have more than 3 million residents,while it did not have a significant impact on Type II large cities,which have fewer than 3 million residents.展开更多
A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of...A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of pneumatic valve the displacement is controlled by electronic control valve. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed according to the geometrical and kinematical information of the compressor. Using the model, the effect of relevant parameters on variable displace control is estimated. It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneumatic valves. And by using this new electronic control device, the optimum systemic control of AAC is available.展开更多
The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was u...The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.展开更多
The air quantity of variable air volume system for the rooms and the total air quantity of the system changes with the change of room load. Combined with the system composition in the laboratory, the paper determines ...The air quantity of variable air volume system for the rooms and the total air quantity of the system changes with the change of room load. Combined with the system composition in the laboratory, the paper determines the control scheme of the variable air volume system, that is, indoor temperature-control, indoor positive pressure control, air distribution static pressure control, air-supply temperature control and new air volume control. The dotted lines with arrows mean the output signals from the control unit to actuator, and the solid lines with arrows represent the input signals from the actuator to the control unit.展开更多
Variable structure control (VSC) applied to atmospheric disturbance sup-pression is presented. The conditions are stipulated: the sliding mode existenee condi-tion, and invanance condition of atmospheric disturbanee i...Variable structure control (VSC) applied to atmospheric disturbance sup-pression is presented. The conditions are stipulated: the sliding mode existenee condi-tion, and invanance condition of atmospheric disturbanee in the variable structuresystem (VSS). A method of eigenstructure assignment technique for switching surfaeedesign is proposed. Based on different atmospheric disturbanee characteristics, such asrandom turbulence, discrete gust and wind shear, two kinds of control laws are derived that possess strong robustness. An example shows that this control approach isfeasible and effective.展开更多
The presence of temperature inversions (TI), concentration of air pollutants (AP) and meteorological variables (MV) affect the welfare of the population, creating public health problems (acute respiratory diseases ARD...The presence of temperature inversions (TI), concentration of air pollutants (AP) and meteorological variables (MV) affect the welfare of the population, creating public health problems (acute respiratory diseases ARDs, among others). The Guadalajara Metropolitan Zone (GMZ) experiences high levels of air pollution, which associated with the presence of temperature inversions and meteorological variations is conducive to the incidence of ARDs in children. The aim of this work is to evaluate the TI, MV, AP and their influence on the ARDs in children under five years in the GMZ from 2003 to 2007. In this period, the moderate and strong TI are the most frequent presenting from November to May. The AP shows a variable behavior during the year and between years, with the highest concentration of particles less than 10 microns (PM10), followed by ozone (O3), nitrogen dioxide (NO2), nitrogen oxides (NOX), carbon monoxide (CO) and sulfur dioxide (SO2), the most affected areas are the southeast of the GMZ. Annual arithmetic mean is 213,510 ± 41,209 ARDs consultations. The most important diseases are acute respiratory infections (98.0%), followed by pneumonia and bronchopneumonia (1.1%), asthma and status asthmaticus (0.5%) and streptococcal pharyngitis and tonsillitis (0.4%). Months with most inquiries were from October to March, mainly in the southeast, south and center of the city, coinciding with high levels of AP. Statistical analysis shows that the TI have significant correlation with ARDs in three years, temperature (Temp) in two, relative humidity (RH) in two, wind speed (WS) in three, wind direction (WD) in two, while that air pollutants NOX and NO2 showed significant correlation with ARDs throughout the period. CO and SO2 showed significance in two years, while the PM10 and O3 in one.展开更多
为促进风电消纳,减少火电机组的碳排放,解决综合能源系统(Integrated Energy System,IES)低碳经济运行问题,文中引入变掺氧富氧燃烧技术对燃气机组进行改造,并结合利用液化天然气(Liquefied Natural Gas,LNG)冷能的液化空气储能(Liquid ...为促进风电消纳,减少火电机组的碳排放,解决综合能源系统(Integrated Energy System,IES)低碳经济运行问题,文中引入变掺氧富氧燃烧技术对燃气机组进行改造,并结合利用液化天然气(Liquefied Natural Gas,LNG)冷能的液化空气储能(Liquid Air Energy Storage,LAES),提出了一种电热气冷IES低碳经济优化策略。首先,构建含变掺氧富氧燃烧燃气机组、利用LNG冷能的LAES、电转气(Power To Gas,P2G)设备、中央空调和溴化锂制冷机的IES架构,并建立各设备的数学模型;其次,引入阶梯式碳交易机制,建立了以系统运行成本最小为目标的电热气冷IES低碳经济调度模型;最后,采用MATLAB调用GUROBI求解器对多个场景进行求解,验证了文中提出的低碳经济优化调度策略可以提高系统的风电消纳、有效降低系统运行成本,实现碳减排。展开更多
基金supported by Preliminary Funding Project of Hubei Provincial Department of Education[Grant No.22ZD100].
文摘This paper investigates the effect and transmission mechanism of air pollution on urbanization based on data from China’s 107 cities during 2005–2018.In order to identify the impact of air pollution on China’s urbanization,we utilized night light data to represent the level of urbanization and used temperature inversion as an instrumental variable to mitigate endogeneity within the two-stage least squares framework.The results suggest that air pollution significantly slowed China’s urbanization process with economic growth acting as the transmission mechanism.The heterogeneity analyses revealed that air pollution had a greater negative impact on urbanization in northern regions than that in southern regions,and a greater negative impact in resource-oriented cities than that in non-resource-based cities.We also find that air pollution was to the detriment of urbanization in larger cities,which have more than 3 million residents,while it did not have a significant impact on Type II large cities,which have fewer than 3 million residents.
文摘A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of pneumatic valve the displacement is controlled by electronic control valve. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed according to the geometrical and kinematical information of the compressor. Using the model, the effect of relevant parameters on variable displace control is estimated. It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneumatic valves. And by using this new electronic control device, the optimum systemic control of AAC is available.
文摘The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.
文摘The air quantity of variable air volume system for the rooms and the total air quantity of the system changes with the change of room load. Combined with the system composition in the laboratory, the paper determines the control scheme of the variable air volume system, that is, indoor temperature-control, indoor positive pressure control, air distribution static pressure control, air-supply temperature control and new air volume control. The dotted lines with arrows mean the output signals from the control unit to actuator, and the solid lines with arrows represent the input signals from the actuator to the control unit.
文摘Variable structure control (VSC) applied to atmospheric disturbance sup-pression is presented. The conditions are stipulated: the sliding mode existenee condi-tion, and invanance condition of atmospheric disturbanee in the variable structuresystem (VSS). A method of eigenstructure assignment technique for switching surfaeedesign is proposed. Based on different atmospheric disturbanee characteristics, such asrandom turbulence, discrete gust and wind shear, two kinds of control laws are derived that possess strong robustness. An example shows that this control approach isfeasible and effective.
文摘The presence of temperature inversions (TI), concentration of air pollutants (AP) and meteorological variables (MV) affect the welfare of the population, creating public health problems (acute respiratory diseases ARDs, among others). The Guadalajara Metropolitan Zone (GMZ) experiences high levels of air pollution, which associated with the presence of temperature inversions and meteorological variations is conducive to the incidence of ARDs in children. The aim of this work is to evaluate the TI, MV, AP and their influence on the ARDs in children under five years in the GMZ from 2003 to 2007. In this period, the moderate and strong TI are the most frequent presenting from November to May. The AP shows a variable behavior during the year and between years, with the highest concentration of particles less than 10 microns (PM10), followed by ozone (O3), nitrogen dioxide (NO2), nitrogen oxides (NOX), carbon monoxide (CO) and sulfur dioxide (SO2), the most affected areas are the southeast of the GMZ. Annual arithmetic mean is 213,510 ± 41,209 ARDs consultations. The most important diseases are acute respiratory infections (98.0%), followed by pneumonia and bronchopneumonia (1.1%), asthma and status asthmaticus (0.5%) and streptococcal pharyngitis and tonsillitis (0.4%). Months with most inquiries were from October to March, mainly in the southeast, south and center of the city, coinciding with high levels of AP. Statistical analysis shows that the TI have significant correlation with ARDs in three years, temperature (Temp) in two, relative humidity (RH) in two, wind speed (WS) in three, wind direction (WD) in two, while that air pollutants NOX and NO2 showed significant correlation with ARDs throughout the period. CO and SO2 showed significance in two years, while the PM10 and O3 in one.
文摘为促进风电消纳,减少火电机组的碳排放,解决综合能源系统(Integrated Energy System,IES)低碳经济运行问题,文中引入变掺氧富氧燃烧技术对燃气机组进行改造,并结合利用液化天然气(Liquefied Natural Gas,LNG)冷能的液化空气储能(Liquid Air Energy Storage,LAES),提出了一种电热气冷IES低碳经济优化策略。首先,构建含变掺氧富氧燃烧燃气机组、利用LNG冷能的LAES、电转气(Power To Gas,P2G)设备、中央空调和溴化锂制冷机的IES架构,并建立各设备的数学模型;其次,引入阶梯式碳交易机制,建立了以系统运行成本最小为目标的电热气冷IES低碳经济调度模型;最后,采用MATLAB调用GUROBI求解器对多个场景进行求解,验证了文中提出的低碳经济优化调度策略可以提高系统的风电消纳、有效降低系统运行成本,实现碳减排。