The stretch bending of L-section variable-curvature SUS301L stainless-steel roof bending beams for metro vehicles was numerically simulated.The causes of defects such as wrinkling,section distortion,and poor contour a...The stretch bending of L-section variable-curvature SUS301L stainless-steel roof bending beams for metro vehicles was numerically simulated.The causes of defects such as wrinkling,section distortion,and poor contour accuracy were analysed,and the corresponding control methods were proposed.The simulation results demonstrated that wrinkling in the small-arc segment could be eliminated by setting the die clearance and adjusting the elongation reasonably.Owing to the sidewall shrinkage of the profile in the process of stretch bending,the die groove depth was correspondingly reduced.Each section of the profile was effectively supported by the bottom of the die groove,and the section distortion could be controlled.Springback was the main reason for the poor contour accuracy,which could be compensated by modifying the die surface based on the springback value.Using the above defect control methods,forming experiments were performed on a new type of stretch bending die with variable die clearance and groove depth developed in this work.Finally,high-quality components were obtained,which verified the efficacy of the defect control methods.展开更多
<strong>Purpose:</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"> Radiotherapy is a widely accepted standard of care for early-sta...<strong>Purpose:</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"> Radiotherapy is a widely accepted standard of care for early-stage prostate cancer, and it is believed that the plan quality and treatment outcome are associated with contour accuracy of both the target and organs-at-risk (OAR). The purposes of this study are to 1) assess geometric and dosimetric uncertainties due to inter-observer contour variabilities and 2) evaluate the effectiveness of geometric indicators to predict target dosimetry in prostate radiotherapy. </span><b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> Twenty prostate patients were selected for this retrospective study. Five experienced clinicians created unique structure sets containing prostate, seminal vesicles, bladder, and rectum for each patient. A fully automated script and knowledge-based planning routine were utilized to create standardized and unbiased plans that could be used to evaluate changes in isodose distributions due to inter-observer variability in structure segmentation. Plans were created on a “gold-standard” structure set, as well as on each of the user-defined structure sets. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> Inter-observer variability of contours during structure segmentation was very low for clearly defined organs such as the bladder but increased for organs without well-defined borders (prostate, seminal vesicles, and rectum). For plans generated with the user-defined structure sets, strong/moderate correlations were observed between the geometric indicators for target structure agreement and target coverage for both low-risk and intermediate-risk patient groups, while OAR indicators showed no correlation to final dosimetry. </span><b><span style="font-family:Verdana;">Conclusions:</span></b><span style="font-family:Verdana;"> Target delineation is crucial in order to maintain adequate dosimetric coverage regardless of the associated inter-observer uncertainties in OAR contours that had a limited impact upon final dosimetry.</span></span>展开更多
基金the National Natural Science Foundation of China(51101072)Technology Development Program of Jilin Province(20150307015GX and 20160204058GX).
文摘The stretch bending of L-section variable-curvature SUS301L stainless-steel roof bending beams for metro vehicles was numerically simulated.The causes of defects such as wrinkling,section distortion,and poor contour accuracy were analysed,and the corresponding control methods were proposed.The simulation results demonstrated that wrinkling in the small-arc segment could be eliminated by setting the die clearance and adjusting the elongation reasonably.Owing to the sidewall shrinkage of the profile in the process of stretch bending,the die groove depth was correspondingly reduced.Each section of the profile was effectively supported by the bottom of the die groove,and the section distortion could be controlled.Springback was the main reason for the poor contour accuracy,which could be compensated by modifying the die surface based on the springback value.Using the above defect control methods,forming experiments were performed on a new type of stretch bending die with variable die clearance and groove depth developed in this work.Finally,high-quality components were obtained,which verified the efficacy of the defect control methods.
文摘<strong>Purpose:</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"> Radiotherapy is a widely accepted standard of care for early-stage prostate cancer, and it is believed that the plan quality and treatment outcome are associated with contour accuracy of both the target and organs-at-risk (OAR). The purposes of this study are to 1) assess geometric and dosimetric uncertainties due to inter-observer contour variabilities and 2) evaluate the effectiveness of geometric indicators to predict target dosimetry in prostate radiotherapy. </span><b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> Twenty prostate patients were selected for this retrospective study. Five experienced clinicians created unique structure sets containing prostate, seminal vesicles, bladder, and rectum for each patient. A fully automated script and knowledge-based planning routine were utilized to create standardized and unbiased plans that could be used to evaluate changes in isodose distributions due to inter-observer variability in structure segmentation. Plans were created on a “gold-standard” structure set, as well as on each of the user-defined structure sets. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> Inter-observer variability of contours during structure segmentation was very low for clearly defined organs such as the bladder but increased for organs without well-defined borders (prostate, seminal vesicles, and rectum). For plans generated with the user-defined structure sets, strong/moderate correlations were observed between the geometric indicators for target structure agreement and target coverage for both low-risk and intermediate-risk patient groups, while OAR indicators showed no correlation to final dosimetry. </span><b><span style="font-family:Verdana;">Conclusions:</span></b><span style="font-family:Verdana;"> Target delineation is crucial in order to maintain adequate dosimetric coverage regardless of the associated inter-observer uncertainties in OAR contours that had a limited impact upon final dosimetry.</span></span>