期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Rotational Swashplate Pulse Continuously Variable Transmission Based on Helical Gear Axial Meshing Transmission 被引量:10
1
作者 SUN Jiandong FU Wenyu +2 位作者 LEI Hong TIAN E LIU Ziping 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第6期1138-1143,共6页
The current research on pulse continuously variable transmission(CVT) is mainly focused on reducing the pulse degree and making pulse degrees a constant value. Current research mainly confined to find out new design... The current research on pulse continuously variable transmission(CVT) is mainly focused on reducing the pulse degree and making pulse degrees a constant value. Current research mainly confined to find out new design parameters by using the method of optimization, and reduce the pulse degree of pulse CVT and its range of variation. But the fact is that the reduction of the pulse degree is not significant. This article presents a new structure of mechanical pulse CVT--the rotational swashplate pulse CVT with driven by helical gear axial meshing. This transmission is simple and compact in structure and low in pulsatile rate (it adopts 6 guide rods), and the pulsatile degree is irrelevant to the transmission ratio. Theoretically, pulsatile rate could be reduced to zero if appropriate curved surface of the swashplate is used. Compared with the connecting rod pulse CVT, the present struc^tre uses helical gear mechanism as transmission part and it avoids unbalanced inertial force in the former model. This paper analyzes the principle of driving of this transmission, presents its mechanical structure, and discusses its motion characteristics. Experimental prototype of this type of CVT has been manufactured. Tests for the transmission efficiency(when the rotational speed of the output shaft is the maximum) and the angular velocity of the output shaft have been carried out, and data have been analyzed. The experimental results show that the speed of the output shaft for the experimental prototype is slightly lower than the theoretical value, and the transmission efficiency of the experimental prototype is about 70%. The pulse degree of the CVT discussed in this paper is less than the existing pulse CVT of other types, and it is irrelevant to the transmission ratio of the CVT. The research provides the new idea to the CVT study. 展开更多
关键词 pulse continuously variable transmission pulsatile rate motion analysis
下载PDF
Synchronous measurements of prefrontal activity and pulse rate variability during online video game playing with functional near-infrared spectroscopy 被引量:1
2
作者 Xuzhe Zhang Kehong Long +2 位作者 Ningxin Wang Jin Zhang Hao Lei 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第6期53-67,共15页
Interactions between the central nervous system(CNS)and autonomic nervous system(ANS)play a crucial role in modulating perception,cognition,and emotion production.Previous studies on CNS–ANS interactions,or heart–br... Interactions between the central nervous system(CNS)and autonomic nervous system(ANS)play a crucial role in modulating perception,cognition,and emotion production.Previous studies on CNS–ANS interactions,or heart–brain coupling,have often used heart rate variability(HRV)metrics derived from electrocardiography(ECG)recordings as empirical measurements of sympathetic and parasympathetic activities.Functional near-infrared spectroscopy(fNIRS)is a functional brain imaging modality that is increasingly used in brain and cognition studies.The fNIRS signals contain frequency bands representing both neural activity oscillations and heartbeat rhythms.Therefore,fNIRS data acquired in neuroimaging studies can potentially provide a single-modality approach to measure task-induced responses in the brain and ANS synchronously,allowing analysis of CNS–ANS interactions.In this proof-of-concept study,fNIRS was used to record hemodynamic changes from the foreheads of 20 university students as they each played a round of multiplayer online battle arena(MOBA)game.From the fNIRS recordings,neural and heartbeat frequency bands were extracted to assess prefrontal activities and shortterm pulse rate variability(PRV),an approximation for short-term HRV,respectively.Under the experimental conditions used,fNIRS-derived PRV metrics showed good correlations with ECG-derived HRV golden standards,in terms of absolute measurements and video game playing(VGP)-related changes.It was also observed that,similar to previous studies on physical activity and exercise,the PRV metrics closely related to parasympathetic activities recovered slower than the PRV indicators of sympathetic activities after VGP.It is concluded that it is feasible to use fNIRS to monitor concurrent brain and ANS activations during online VGP,facilitating the understanding of VGP-related heart–brain coupling. 展开更多
关键词 Heart rate variability pulse rate variability functional near-infrared spectroscopy video game prefrontal cortex heart–brain coupling
下载PDF
Effects of pulse parameters on arc characteristics and weld penetration in hybrid pulse VP-GTAW of aluminum alloy 被引量:4
3
作者 从保强 杨明轩 +2 位作者 齐铂金 王乐笑 李伟 《China Welding》 EI CAS 2010年第4期68-73,共6页
A novel ultrafast-convert hybrid pulse variable polarity gas tungsten arc welding process (HPVP-GTAW) is developed. High frequency pulse square-wave current which has a frequency of more than 20 kHz is exactly integ... A novel ultrafast-convert hybrid pulse variable polarity gas tungsten arc welding process (HPVP-GTAW) is developed. High frequency pulse square-wave current which has a frequency of more than 20 kHz is exactly integrated in the positive polarity current duration. The effects of pulse current parameters on arc characteristics and weld penetration have been studied during the HPVP-GTAW process using Al-5. 8 Mg alloy plates. The arc characteristics studied by arc voltage and its profile, weld penetration noted by the ratio of weld depth to width have been found to be influenced significantly by the pulse current. The experimental results show that the HPVP-GTA W process can improve the arc profile predominantly and obtain the higher weld penetration with lower heat input. The observation may help in understanding the weld characteristics with respect to variation in the pulse current parameters which may be beneficial in using the novel HPVP-GTAW process to produce the better weld quality of aluminum alloy plates. 展开更多
关键词 hybrid pulse variable polarity current gas tungsten arc welding arc characteristics weld penetration aluminum alloy
下载PDF
Asymmetric Three-Phase Cascading Trinary-DC Source Multilevel Inverter Topologies for Variable Frequency PWM
4
作者 G. Irusapparajan D. Periyaazhagar 《Circuits and Systems》 2016年第4期506-519,共14页
Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascad... Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascaded full bridge inverter operation with dissimilar (unequal) DC Source and it is fired by using variable frequency pulse with modulation technique as a switching strategy. This pulse width modulation switching strategy has a newly adopted multicarrier single reference technique. The performance parameter factors like Form Factor (FF), Crest Factor (CF), Total Harmonic Distortion (THD) and fundamental RMS output voltage (V<sub>RMS</sub>) are estimated by using proposed asymmetrical three-phase cascading multilevel inverter for several modulation indices (0.8 - 1). The research study carries with MATLAB/SIMULINK based simulation and experimental results obtained using appropriate prototype (test board) to prove the viability of the proposed concept. 展开更多
关键词 Trinary Multilevel Inverter variable Frequency pulse Width Modulation Total Harmonic Distortions Trinary-DC Source Distortion Factor
下载PDF
Single-turnover and multiple-turnover measurement of phytoplankton photosynthesis parameters using variable light pulse induced fluorescence
5
作者 石朝毅 高先和 +4 位作者 殷高方 覃志松 段静波 陈双 卢军 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第1期81-85,共5页
Using a measurement system based on fluorescence induced by variable pulse light, photosynthesis parameters of chlorella pyrenoidosa are obtained, employing single-turnover and multiple-turnover protocols under darkad... Using a measurement system based on fluorescence induced by variable pulse light, photosynthesis parameters of chlorella pyrenoidosa are obtained, employing single-turnover and multiple-turnover protocols under darkadapted and light-adapted conditions. Under the light-adapted condition,σ’PSII is larger, and F’v/F’m(ST) and F’v/F’m(MT) are smaller than those of the dark-adapted condition, but the corresponding parameters possess good linear correlations.Fm(MT), F’m(MT), Fv/Fm(MT) and F’v/F’m(MT) which are measured using the multipleturnover protocol, are larger than those of the single-turnover protocol. The linear correlation coefficient between Fm(ST) and Fm(MT) is 0.984,and Fv/Fm(MT) = 1.18 Fv/Fm(ST) The linear correlation coefficient between F’m(ST) and F’m(MT) is 0.995, and F’v/F’m(MT) = 1.36 F’v/F’m/(ST). 展开更多
关键词 Single-turnover and multiple-turnover measurement of phytoplankton photosynthesis parameters using variable light pulse induced fluorescence
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部