期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Flip-over of blood vessel intima caused by vascular closure device:A case report
1
作者 Li-Xia Sun Xue-Song Yang +4 位作者 Da-Wei Zhang Bo Zhao Lian-Lian Li Qi Zhang Qing-Zhi Hao 《World Journal of Clinical Cases》 SCIE 2022年第7期2247-2252,共6页
BACKGROUND Complications of vascular closure devices mainly include bleeding,vascular injury,and trapped device that cannot be removed percutaneously.However,arterial stenosis or occlusion induced by vascular injury i... BACKGROUND Complications of vascular closure devices mainly include bleeding,vascular injury,and trapped device that cannot be removed percutaneously.However,arterial stenosis or occlusion induced by vascular injury is rare.This article introduces a rare case with severe acute limb ischemia after using the vascular closure device(StarClose).CASE SUMMARY A 54-year-old man was admitted because of necrosis of the second toe of the left foot for 2 mo.Ultrasound showed left femoral artery stenosis,and occlusion of the left popliteal,posterior tibial,peroneal,anterior tibial and dorsalis pedis arteries,suggesting arteriosclerosis obliterans of low extremities,gangrene and type 2 diabetes.He underwent an interventional procedure of drug-eluting balloon in the left lower limb via antegrade puncture of the left common femoral artery.He developed acute limb ischemia after 1 h,and severe pain,numbness,pale skin,low skin temperature and weakened sensation in the left foot.Injury of the common femoral artery intima was considered.Exploratory surgery showed occlusion at the puncture point accompanied with bulged vascular lumen and flipped vascular intima caused by StarClose.The flipped intima was removed.The limb blood supply was restored and the limb was saved post-surgery.He recovered well at final follow-up.CONCLUSION Incorrect use of the vascular closure device was the main cause of severe acute limb ischemia in this case. 展开更多
关键词 StarClose vascular closure device vascular injury COMPLICATIONS Case report
下载PDF
Flexible Subclavian Artery Closure for an Inadvertent Injury to the Internal Mammary Artery During Internal Jugular Vein Catheterization 被引量:1
2
作者 Dong-Dong Que Lei Liu +7 位作者 Xu-Dong Song Xian-Bao Wang Xiu-Li Zhang Yi-Jun Zhou Li-Yun Feng Wen-Jie Yu Yuan-Qing Li Ping-Zhen Yang 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第7期868-870,共3页
Central vein catheter (CVC) placement, which is widely utilized in clinical departments, is also highly important in preoperative preparations for radiofrequency catheter ablation (RFCA). The internal jugular vein... Central vein catheter (CVC) placement, which is widely utilized in clinical departments, is also highly important in preoperative preparations for radiofrequency catheter ablation (RFCA). The internal jugular vein or subclavian vein is the routine target. Arterial injury is not uncommon during the procedure but is potentially devastating in spite of the safety and advantages of the Seldinger technique. Compressing of the airway by a hematoma, as well as hemothorax, pseudoaneurysm, arteriovenous fistula, stroke, and even death, has been well-described. 展开更多
关键词 Internal Jugular Vein Catheterization Internal Mammary Artery Subclavian Artery Injury vascular closure Device
原文传递
Outcomes of Clinical Application of Boomerang Closure Wire System
3
作者 吴剑胜 魏文斌 +2 位作者 王毓佳 张新霞 胡雪松 《South China Journal of Cardiology》 CAS 2009年第1期19-22,共4页
To evaluate the efficacy and safety of clinical application of a novel type of vascular closure device named Boomerang closure wire system (BCWS). Methods BCWSs were hemostasis after transfemoral coronary angiograp... To evaluate the efficacy and safety of clinical application of a novel type of vascular closure device named Boomerang closure wire system (BCWS). Methods BCWSs were hemostasis after transfemoral coronary angiography (CAG) or percutaneous used in 288 patients (BCWSs group) for coronary intervention (PCI). Device success rate, hemostasis success rate, manual compression time, recumbent time, minor peripheral complication rate, severe peripheral complication rate and hospital staying time after procedure were analyzed. Results were compared to those from 300 patients (control group) who received manual compression in our hospital during the same period Results In BCWS group, device success rate was 97.2 %, hemostasis success rate was 95.1%. Manual compression time in CAG subgroup and PCI subgroup was 7.8 min and 11.2 min, respectively. Recumbent time was 136. 3 min in CAG subgroup, 284.6 min in PCI subgroup. Minor peripheral complication rate was 4.5 %, severe peripheral complication rate was 2. 4 %. Hospital-staying time after procedure in CAG group and PCI group was 1.8 d and 6. 6 d, respectively. Compared to control group, manual compression time, recumbent time and hospital-staying time of BCWSs group had statistical significance; hemostasis success rate, minor peripheral complication rate and severe peripheral complication rate of BCWSs group had no statistical difference. Conclusions BCWS provides satisfied haemostatic effect. Compared to routine manual compression, BCWS shortens manual compression time, recumbent time and hospital staying time. ( S Chin J Cardiol 2009; 10(1) : 19 -22) 展开更多
关键词 femoral artery vascular closure device coronary angiography percutaneous coronary intervention
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部