期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Evolutionary Computation Based Optimization of Image Zernike Moments Shape Feature Vector 被引量:1
1
作者 LIU Maofu HU Hujun +2 位作者 ZHONG Ming HE Yanxiang HE Fazhi 《Wuhan University Journal of Natural Sciences》 CAS 2008年第2期153-158,共6页
The image shape feature can be described by the image Zernike moments. In this paper, we points out the problem that the high dimension image Zernike moments shape feature vector can describe more detail of the origin... The image shape feature can be described by the image Zernike moments. In this paper, we points out the problem that the high dimension image Zernike moments shape feature vector can describe more detail of the original image but has too many elements making trouble for the next image analysis phases. Then the low dimension image Zernike moments shape feature vector should be improved and optimized to describe more detail of the original image. So the optimization algorithm based on evolutionary computation is designed and implemented in this paper to solve this problem. The experimental results demonstrate the feasibility of the optimization algorithm. 展开更多
关键词 Zernike moment image Zernike moments shape feature vector image reconstruction evolutionary computation
下载PDF
Clinical Study of the Ascending Aorta Wall Motion by Velocity Vector Imaging in Patients with Primary Hypertension 被引量:2
2
作者 王蕾 王静 +4 位作者 谢明星 王新房 吕清 陈明 郑少萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第1期127-130,共4页
We studied the wall motion characteristics of the ascending aorta by velocity vector imaging (VVI) in primary hypertension patients. The ascending aortas both in 30 patients with primary hypertension and 30 normal c... We studied the wall motion characteristics of the ascending aorta by velocity vector imaging (VVI) in primary hypertension patients. The ascending aortas both in 30 patients with primary hypertension and 30 normal controls were examined by Acuson sequoia 512 equiped with VVI. The maximum velocity (Vs, Ve) of every point on the anterior wall of ascending aorta both in systole and diastole was measured. The aortic diameter was wider in the hypertension patients than that in the healthy subjects (P〈0.05). The movement amplitude of the anterior wall of the ascending aorta in long axis view in the hypertension patients was lower than that in the healthy subjects (P〈0.05). The motion and time to peak in systole of each point of the ascending aorta in the healthy subjects had no significant difference (P〉0.05). The velocity curves of the anterior wall of ascending aorta both in the hypertension and healthy subjects were regular, and the curve in systole was named S wave and that in diastole named E wave. The velocity of S wave and E wave was slower in the hypertension patients than that in the healthy subjects (P〈0.05). The time to peak of S wave on the anterior wall of ascending aorta in systole was shorter in the hypertension patients than in the healthy subjects (P〈0.05). VVI could be used to accurately and directly observe the movement character of the ascending aorta walls, which would help us understand the elasticity of great arteries in patients with hypertension. 展开更多
关键词 velocity vector imaging HYPERTENSION ascending aorta anterior wall
下载PDF
An edge-adaptive demosaicking method based on image correlation 被引量:1
3
作者 贾晓芬 赵佰亭 +1 位作者 周孟然 陈兆权 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1397-1404,共8页
To reduce the cost, size and complexity, a consumer digital camera usually uses a single sensor overlaid with a color filter array(CFA) to sample one of the red-green-blue primary color values, and uses demosaicking a... To reduce the cost, size and complexity, a consumer digital camera usually uses a single sensor overlaid with a color filter array(CFA) to sample one of the red-green-blue primary color values, and uses demosaicking algorithm to estimate the missing color values at each pixel. A novel image correlation and support vector machine(SVM) based edge-adaptive algorithm was proposed, which can reduce edge artifacts and false color artifacts, effectively. Firstly, image pixels were separated into edge region and smooth region with an edge detection algorithm. Then, a hybrid approach switching between a simple demosaicking algorithm on the smooth region and SVM based demosaicking algorithm on the edge region was performed. Image spatial and spectral correlations were employed to create middle planes for the interpolation. Experimental result shows that the proposed approach produced visually pleasing full-color result images and obtained higher CPSNR and smaller S-CIELAB*ab?E than other conventional demosaicking algorithms. 展开更多
关键词 demosaicking image correlation support vector machine edge-adaptability
下载PDF
Spatial-Aware Supervised Learning for Hyper-Spectral Image Classification Comprehensive Assessment
4
作者 SOOMRO Bushra Naz XIAO Liang +1 位作者 SOOMRO Shahzad Hyder MOLAEI Mohsen 《Journal of Donghua University(English Edition)》 EI CAS 2016年第6期954-960,共7页
A comprehensive assessment of the spatial.aware mpervised learning algorithms for hyper.spectral image (HSI) classification was presented. For this purpose, standard support vector machines ( SVMs ), mudttnomial l... A comprehensive assessment of the spatial.aware mpervised learning algorithms for hyper.spectral image (HSI) classification was presented. For this purpose, standard support vector machines ( SVMs ), mudttnomial logistic regression ( MLR ) and sparse representation (SR) based supervised learning algorithm were compared both theoretically and experimentally. Performance of the discussed techniques was evaluated in terms of overall accuracy, average accuracy, kappa statistic coefficients, and sparsity of the solutions. Execution time, the computational burden, and the capability of the methods were investigated by using probabilistie analysis. For validating the accuracy a classical benchmark AVIRIS Indian pines data set was used. Experiments show that integrating spectral.spatial context can further improve the accuracy, reduce the misclassltication error although the cost of computational time will be increased. 展开更多
关键词 learning algorithms hyper-spectral image classification support vector machine(SVM) multinomial logistic regression(MLR) elastic net regression(ELNR) sparse representation(SR) spatial-aware
下载PDF
Fast compression of computer-generated holographic images based on a GPU-accelerated skip-dimension vector quantization method
5
作者 Y.K.Lam W.C.Situ P.W.M.Tsang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第5期28-32,共5页
A method for fast and low bit-rate compression of digital holograms based on a new vector quantization (VQ) method known as the skip-dimension VQ (SDVQ) is proposed. Briefly, a complex hologram is converted into a... A method for fast and low bit-rate compression of digital holograms based on a new vector quantization (VQ) method known as the skip-dimension VQ (SDVQ) is proposed. Briefly, a complex hologram is converted into a real off-axis hologram, and partitioned into a set of image vectors. The image vectors are passed into a graphic processing unit (GPU), and compressed through SDVQ into a set of code indices considerably smaller in data size than the source hologram. Experimental evaluation reveals that our scheme is capable of compressing a digital hologram to a compression ratio of over 500 times, in approximately 20-22 ms. 展开更多
关键词 GPU Fast compression of computer-generated holographic images based on a GPU-accelerated skip-dimension vector quantization method VQ
原文传递
Comparison of Elastic Properties of Bilateral Carotid Arteries in Relation to Site of Acute Ischemic Stroke Using Velocity Vector Imaging 被引量:2
6
作者 Jun-Li Hu Xian Li +4 位作者 Xi-Ming Wang Zhao-Ping Cheng Dong-Feng Chen Shao-Chun Wang Qing-Xia Kong 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第21期2960-2963,共4页
INTRODUCTIONlschemic stroke accounts for 70% of all the cerebrovascular diseases. Severe stenosis and occlusions ofextracranial and intracranial artery are all important risk factors causing ischemic stroke. Based on ... INTRODUCTIONlschemic stroke accounts for 70% of all the cerebrovascular diseases. Severe stenosis and occlusions ofextracranial and intracranial artery are all important risk factors causing ischemic stroke. Based on the widespread observation worldwide, intracranial atherosclerosis is the most common vascular lesions in Asians, Hispanics, and Africans. Therefore, accurate and noninvasive methods fbr early diagnosis of stroke in individuals without significant stenosis of the extracranial carotid artery is of considerable clinical interest. 展开更多
关键词 ACUTE CAROTID lschemic STROKE Velocity vector Imaging
原文传递
Evaluation of the asynchronization and function of the left ventricle in patients with chronic pulmonary hypertension by velocity vector imaging 被引量:2
7
作者 WANG Chao-hong WANG Yue-heng NIU Ning-ning XIE Ying-xin WANG Lin 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第23期4457-4462,共6页
Background Pulmonary hypertension (PH) is a set of pathophysiological syndromes characterized by increased pulmonary artery pressure and pulmonary vascular resistance,resulting in increased right ventricular afterlo... Background Pulmonary hypertension (PH) is a set of pathophysiological syndromes characterized by increased pulmonary artery pressure and pulmonary vascular resistance,resulting in increased right ventricular afterload.The left and right ventricles interact through hemodynamics.What impact will PH have on synchronization and function of the left ventricle (LV)? The aim of this study was to evaluate the synchronization of the left ventricular wall motion and left ventricular function in patients with varying degrees of PH using velocity vector imaging (Wl) technology.Methods Sixty patients with chronic PH served as the experimental group,and 20 healthy volunteers served as the control group.According to the different degrees of pulmonary artery systolic pressure,the experimental group was divided into three groups:mild,moderate,and severe PH groups.The time to peak systolic longitudinal velocity (Tvl),the peak systolic longitudinal velocity (Vsl),the peak diastolic longitudinal velocity (Vel),the peak systolic longitudinal strain (SI),and strain rate (SRI) in 18 segments were measured in each group.Results TvI in the control group and each group with PH was reduced from basal to apical segment,and in control group Tvl in various segments of the same wall and in different walls showed no significant difference (P >0.05).With increase in pulmonary artery pressure,Tvl values measured showed an increasing trend in groups with PH.In groups with PH,Vsl and Vel of each wall were reduced sequentially from basal to apical segments,showing gradient change; Vsl and Vel values measured showed a decreasing trend with increase in pulmonary artery pressure,in which the differences of Vel values measured in the control group and the mild PH group were statistically significant (P <0.01),and the differences between other groups were statistically significant (P <0.01).In groups with PH,SI and SRI in basal segment and the middle segment of each wall were decreased; the difference between groups was statistically significant (P <0.01).Conclusions Asynchronization of the LV and decreased left ventricular function were present in patients with chronic PH;WI technology can accurately evaluate left ventricular function in patients with PH,and indicators such as Tvl,Vsl,and Vel are valuable. 展开更多
关键词 ECHOCARDIOGRAPHY pulmonary hypertension left ventricular function SYNCHRONIZATION velocity vector imaging
原文传递
Use of velocity vector imaging technology to evaluate the motion of myocardial infarction
8
作者 马莎 王玉璟 潘炎 《South China Journal of Cardiology》 CAS 2012年第3期201-205,共5页
Background The velocity vector imaging is an ultrasound speckle imaging that was recently developed, which is based on the two-dimensional gray scale image, with more accurate tracking process and more conve-nient and... Background The velocity vector imaging is an ultrasound speckle imaging that was recently developed, which is based on the two-dimensional gray scale image, with more accurate tracking process and more conve-nient and time-saving operation method can quantitatively displays the varied curve of myocardial velocity and direction sampling taking from multiple parts in one cardiac cycle by tracking the space motion of echo spots of the cardiovascular tissue, and then analyze their movements, avoiding the angular dependence and the limita-tions of analysis section that could effect on Doppler technology. The technology provides a new auxiliary method for the diagnosis and treatment of cardiovascular disease and is valuable on clinical diagnosis and scientific re-search and a wide horizon of development. 展开更多
关键词 ventricular torsion velocity vector imaging cardiac function
原文传递
Deformation of the left and right ventricular longitudinal myocardium in fetuses with umbilical cord around neck 被引量:5
9
作者 ZUO Dong-mei WANG Chao-hong WANG Yue-heng 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第9期1608-1613,共6页
Background Umbilical cord around neck, a common obstetric complication, affects fetal hemodynamics. Does it influence fetal cardiac functions? The purpose of this study was to investigate the left and right ventricu... Background Umbilical cord around neck, a common obstetric complication, affects fetal hemodynamics. Does it influence fetal cardiac functions? The purpose of this study was to investigate the left and right ventricular systolic and diastolic functions of fetuses with umbilical cord around neck in the third trimester by applying velocity vector imaging (VVI). Methods Thirty-five cases of fetuses with umbilical cord around neck whose gestational ages from 35 to 40 weeks were selected, including 20 cases of umbilical artery ratio of the highest systolic velocity (S) to the lowest diastolic velocity (D) (S/D) 〈3.0 and 15 cases of umbilical artery S/D ≥3.0, while 20 cases of normal fetuses of 35–40 gestational weeks were selected as the control group. The changes in longitudinal velocity, strain, and strain rate of fetal left and right ventricle in systole and diastole in two groups, and the changes in fetal cardiac function under the situation of umbilical cord around neck were analyzed.Results Longitudinal strain and strain rate overall of fetal left and right ventricle in systole and diastole were less in fetuses with umbilical artery S/D 33.0 and umbilical cord around neck than those in fetuses with umbilical artery S/D 〈3.0 and those in control group (P 〈0.05); there was no significant difference (P 〉0.05) in longitudinal strain and strain rate overall of fetal left and right ventricle in systole and diastole between fetuses with umbilical artery S/D 〈3.0 and those in control group.Conclusions Left and right ventricular systolic and diastolic dysfunction was detected in fetuses with umbilical cord around neck and umbilical artery S/D 33.0. VVI could sensitively respond to cardiac function changes in fetuses with umbilical cord around neck, which provides another valuable method in the evaluation of fetal cardiac function. 展开更多
关键词 velocity vector imaging umbilical cord around neck FETUS ventricular function
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部