To satisfy the demand of measuring the velocity of ground moving target through unmanned aerial vehicle(UAV)electro-optical platform,two velocity measurement methods are proposed.Firstly,a velocity measurement method ...To satisfy the demand of measuring the velocity of ground moving target through unmanned aerial vehicle(UAV)electro-optical platform,two velocity measurement methods are proposed.Firstly,a velocity measurement method based on target localization is derived,using the position difference between two points with the advantages of easy deployment and realization.Then a mathematical model for measuring target velocity is built and described by 15 variables,i.e.UAV velocity,UAV attitude angular rate,camera direction angular rate and so on.Moreover,the causes of velocity measurement error are analyzed and a formula is derived for calculating the measurement error.Finally,the simulation results show that angular rate error has a strong influence on the velocity measurement accuracy,especially the UAV pitch angular rate error,roll angular rate error and the camera angular altitude rate error,thus indicating the direction for improving velocity measurement precision.展开更多
The measurement errors due to nonparallelness of specimen faces in the ultrasonic velocity and attenuation coefficient measured by the pulse reflection method in VHF range have been investigated theoretically, and the...The measurement errors due to nonparallelness of specimen faces in the ultrasonic velocity and attenuation coefficient measured by the pulse reflection method in VHF range have been investigated theoretically, and the theoretical expressions for estimating these measurement errors are given. It has also been shown that, the attenuation coefficient error is depending on both the nonparallelness angle of specimen faces and the ultrasonic frequency, but the velocity error is only depending on the former. Furthermore, for pure silica glass specimen it is estimated that, in VHF range in order to insure that the attenuation coefficient and velocity errors due to nonparallelness of specimen faces are less than 10% and 0.01%, respectively, the nonparallelness angle of specimen faces must be less than 10 s and 40 s correspondingly.展开更多
基金supported by the Aeronautical Science Foundation of China(No.61106018)
文摘To satisfy the demand of measuring the velocity of ground moving target through unmanned aerial vehicle(UAV)electro-optical platform,two velocity measurement methods are proposed.Firstly,a velocity measurement method based on target localization is derived,using the position difference between two points with the advantages of easy deployment and realization.Then a mathematical model for measuring target velocity is built and described by 15 variables,i.e.UAV velocity,UAV attitude angular rate,camera direction angular rate and so on.Moreover,the causes of velocity measurement error are analyzed and a formula is derived for calculating the measurement error.Finally,the simulation results show that angular rate error has a strong influence on the velocity measurement accuracy,especially the UAV pitch angular rate error,roll angular rate error and the camera angular altitude rate error,thus indicating the direction for improving velocity measurement precision.
文摘The measurement errors due to nonparallelness of specimen faces in the ultrasonic velocity and attenuation coefficient measured by the pulse reflection method in VHF range have been investigated theoretically, and the theoretical expressions for estimating these measurement errors are given. It has also been shown that, the attenuation coefficient error is depending on both the nonparallelness angle of specimen faces and the ultrasonic frequency, but the velocity error is only depending on the former. Furthermore, for pure silica glass specimen it is estimated that, in VHF range in order to insure that the attenuation coefficient and velocity errors due to nonparallelness of specimen faces are less than 10% and 0.01%, respectively, the nonparallelness angle of specimen faces must be less than 10 s and 40 s correspondingly.