期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Study on cook-off characteristics and thermal safety venting area of RBOE charge
1
作者 Kebin Zhang Wenbin Li +3 位作者 Changfang Zhao Zhifang Wei Shuxia Zhang Jin Li 《Defence Technology(防务技术)》 2025年第1期271-287,共17页
RBOE is a new type of DNAN-based high-energy melt-cast mixed explosive,whose safety under thermal stimulation is significantly affected by heating conditions and venting area of the warhead.Based on the thermal decomp... RBOE is a new type of DNAN-based high-energy melt-cast mixed explosive,whose safety under thermal stimulation is significantly affected by heating conditions and venting area of the warhead.Based on the thermal decomposition reaction characteristics and combustion characteristics of each component of RBOE explosive,the cook-off calculation models of RBOE warhead before and after ignition were established.In addition,closed and vented warheads were designed,as well as fast and slow cook-off test devices.The cook-off characteristics and thermal safety venting area of RBOE warhead were extensively studied.The results showed that the closed RBOE warhead underwent deflagration reaction under both slow and fast cook-off conditions.The calculation result of the shell wall temperature before slow cookoff ignition response of the warhead was 454.06 K,with an error of+1.75%compared to the test result of462.15 K,and the temperature rise rate calculated was in good agreement with the test.The calculated ignition time of RBOE warhead under fast cook-off was 161 s,with an error of+8.8%compared to the test result of 148 s,which verified the accuracy of cook-off model of RBOE warhead before ignition.According to the cook-off calculation model of the warhead after ignition and cook-off test of the vented warhead,it was determined that the thermal safety venting area was 1124.61 mm^(2)for fast cook-off and 530.66 mm~2 for slow cook-off,effectively preventing the reaction of warhead above combustion.Therefore,this study provides a scientific basis for the thermal safety design and evaluation of insensitive warheads. 展开更多
关键词 RBOE explosive Cook-off model Temperature distribution Pressure growth Venting area
下载PDF
Effect of an escape vent in accordion-shaped traps on the catch and size of Asian paddle crabs Charybdis japonica in an artificial reef area 被引量:2
2
作者 张鹏 李超 +1 位作者 李文涛 张秀梅 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2016年第6期1238-1246,共9页
Accordion-shaped traps are widely used in China to catch the Asian paddle crab C harybdis japonica but traps of conventional design often catch juvenile crabs. A new type of accordion-shaped trap with an escape vent(L... Accordion-shaped traps are widely used in China to catch the Asian paddle crab C harybdis japonica but traps of conventional design often catch juvenile crabs. A new type of accordion-shaped trap with an escape vent(L×W=4.3 cm×3.0 cm) was designed and a comparative study between the newly designed and conventional traps was performed in the artifi cial reef area of Zhuwang, Laizhou Bay, China from June to August 2012. The mean catch per unit effort(CPUE) of undersized crabs was signifi cantly lower in the vented traps than in the conventional traps(paired t-test, n =30, P <0.001), while the CPUE of marketable crabs was signifi cantly higher in the vented traps(paired t-test, n =30, P <0.001). The mean size of crabs(carapace length) caught in the vented traps was signifi cantly larger than in conventional traps(paired t-test, n =29, P <0.001). The ratio of undersized crabs was 35.05%±2.57% in conventional traps and 12.53%±0.69% in vented traps(signifi cantly lower, paired t-test, n =29, P <0.001). Therefore, a 4.3 cm×3.0 cm escape vent was considered appropriate for C. japonica fi shing in the artifi cial reef area. This fi nding will assist the development of more sustainable and effi cient crab fi shing methods using accordion-shaped traps. 展开更多
关键词 Charybdis japonica accordion-shaped trap escape vent selectivity artificial reef area
下载PDF
Magmatism and tectonic processes in Area A hydrothermal vent on the Southwest Indian Ridge 被引量:15
3
作者 ZHANG Tao LIN Jian GAO JinYao 《Science China Earth Sciences》 SCIE EI CAS 2013年第12期2186-2197,共12页
The hydrothermal vent in Area A (37.78°S, 49.65°E) is the first active hydrothermal vent discovered on the Southwest Indian Ridge (SWlR). Heat source and adequate bulk permeability are two necessary fact... The hydrothermal vent in Area A (37.78°S, 49.65°E) is the first active hydrothermal vent discovered on the Southwest Indian Ridge (SWlR). Heat source and adequate bulk permeability are two necessary factors for the formation of a hydrothermal vent. Along the SWIR 49.3°E to 51.2°E, the gravity-derived crustal thickness is up to 9.0 km, much thicker than the average thick- ness of the global oceanic crust. This characteristic indicates that the magma supply in this area is robust, which is possibly af- fected by a hotspot. The large-scale residual mantle Bouguer anomalies (RMBA) reveal prominent negative-gravity anomalies between the first-order ridge segment (from Indomed to Gallieni, 46.0°E to 52.0°E) and the Marion-Del Cano-Crozet region. These anomalies indicate the channel of the hotspot-ridge interaction. The tomography data corrected with theoretical thermal model indicate that the low-velocity anomalies corresponding to this channel can reach the base of the lithosphere. Near the hydrothermal vent area, the topography and crustal thickness at the off-axis area are extremely asymmetrical. South of the SWIR, the high topography corresponds to the thinning crustal thickness. The residual isostatic topography anomalies indicate that Area A is a deviation from the local isostatic equilibrium, similar to the characteristics of the transform fault inside corner. The forward profiles of the magnetic data indicate that the thinning magnetic layer at the south side of Area A corresponds to the shallow, high-velocity area revealed by the OBS, which is the result of tectonic extension of a detachment fault. The active tectonic processes in Area A can provide sufficient crustal permeability to the hydrothermal circulation and may form massive sulfide deposits. 展开更多
关键词 ultra-slow spreading ridge area A hydrothermal vent RMBA hotspot-ridge interaction detachment fault
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部