A NUMERICAL ANALYSIS OF THE VENTILATION PERFORMANCE FOR DIFFERENT VENTILATION STRATEGIES IN A SUBWAY TUNNEL 被引量:8
1
作者 HUANG Yuan-dong LI Chan KIM Chang Nyung 《Journal of Hydrodynamics》 SCIE EI CSCD 2012年第2期193-201,共9页
An unsteady three-dimensional analysis of the ventilation performance is carried out for different ventilation strategies to find out a ventilation method with a high performance in a subway tunnel.The natural ventila... An unsteady three-dimensional analysis of the ventilation performance is carried out for different ventilation strategies to find out a ventilation method with a high performance in a subway tunnel.The natural ventilation performance associated with a train-induced air flow in a subway tunnel is examined.The dynamic layering method is used to consider the moving boundary of a train in the current CFD method.The geometries of the modeled tunnel and the subway train are partially based on those of the Seoul subway.The effects of the structure of the ventilation duct and the geometry of the partitions on the ventilation performance are evaluated.The results show that the combined ventilation ducts (to be designed),and the partitioning blocks installed along the middle of tunnel (already in existences) are helpful for air exchange.This study can provide some guidance for the design of ventilation ducts in a subway system. 展开更多
关键词 ventilation performance subway tunnel train-induced air flow natural ventilation duct numerical analysis
原文传递
Investigation of natural ventilation performance of large space circular coal storage dome 被引量:4
2
作者 Yaohua Hou Chao Chen +2 位作者 Yu Zhou Zhixiang Yang Shen Wei 《Building Simulation》 SCIE EI CSCD 2021年第4期1077-1093,共17页
Large space circular coal storage dome(LSCCSD)offers an environmental and dependable alternative to open stockpiles,and it has been consequently widely applied in China.However,due to the lack of scientific guidelines... Large space circular coal storage dome(LSCCSD)offers an environmental and dependable alternative to open stockpiles,and it has been consequently widely applied in China.However,due to the lack of scientific guidelines,its natural ventilation performance is lower than expected.Natural ventilation potential strongly depends on the roof geometry and opening mode,which have not yet been investigated for LSCCSD.This paper presents a detailed evaluation of the impact of dome geometry(rise span ratio),opening height,and opening modes on the ventilation performance of LSCCSD.The evaluation is based on computational fluid dynamics(CFD)methods and is validated by available wind tunnel testing.We employed three evaluation indicators,which are wind pressure coefficient,effective ventilation rate,and wind speed ratio.The results demonstrate that the rise span ratio has a significant effect on the wind pressure difference and the effective ventilation rate increases by approximately 9%–42%with a single-annular opening.When double-annular openings are set in a strong positive pressure zone,the effective ventilation rate increases by 100%and the average wind speed ratio increases by 50%.When it is compared with single one with similar opening height,the effective ventilation rate increases by 25%.The optimum natural ventilation performance for LSCCSD is achieved at a rise span ratio of 0.37.In addition,the lateral middle opening is kept higher than the ridge top of the coal pile.The proposed evaluation approach and design parameters provided instructive information in the building design and ventilation control for LSCCSDs. 展开更多
关键词 large space circular coal storage dome natural ventilation performance opening mode computational fluid dynamics evaluation indicator
原文传递
Ventilator performance evaluation system based on virtual instruments
3
作者 戴文 任旭颖 林青 《Journal of Measurement Science and Instrumentation》 CAS 2012年第1期22-25,共4页
A virtual instrument system is proposed to test the performance parameters of local-ventilator installed under coal mines,which can do ventilator parameter acquisition automatically,as well as plot and analyze the ven... A virtual instrument system is proposed to test the performance parameters of local-ventilator installed under coal mines,which can do ventilator parameter acquisition automatically,as well as plot and analyze the ventilator performance curve.The whole system is designed using the virtual instrument technology combined with network technology based on Labview platform.Experimental results show that it can monitor and evaluate ventilator’s performance parameters automatically and efficiently,which provides critical information for ventilator safety under coal mine. 展开更多
关键词 virtual instrument ventilator performance evaluation remote transmission
下载PDF
A NUMERICAL STUDY OF THE TRAIN-INDUCED UNSTEADY AIRFLOW IN A SUBWAY TUNNEL WITH NATURAL VENTILATION DUCTS USING THE DYNAMIC LAYERING METHOD 被引量:17
4
作者 HUANG Yuan-dong GAO Wei KIM Chang-Nyung 《Journal of Hydrodynamics》 SCIE EI CSCD 2010年第2期164-172,共9页
The objective of this study is to investigate numerically the characteristics of train-induced unsteady airflow in a subway tunnel with natural ventilation ducts.A three-dimensional numerical model using the dynamic l... The objective of this study is to investigate numerically the characteristics of train-induced unsteady airflow in a subway tunnel with natural ventilation ducts.A three-dimensional numerical model using the dynamic layering method for the moving boundary of a train is first developed,and then it is validated against the model tunnel experimental data.With the tunnel and subway train geometries in the numerical model exactly the same as those in the model tunnel experimental test,but with the ventilation ducts being connected to the tunnel ceiling and a barrier placed at the tunnel outlet,the three-dimensional train-induced unsteady tunnel flows are numerically simulated.The computed distributions of the pressure and the air velocity in the tunnel as well as the time series of the mass flow rate at the ventilation ducts reveal the impact of the train motion on the exhaust and suction of the air through ventilation ducts and the effects of a barrier placed at the tunnel outlet on the duct ventilation performance.As the train approaches a ventilation duct,the air is pushed out of the tunnel through the duct.As the train passes the ventilation duct,the exhaust flow in the duct is changed rapidly to the suction flow.After the train passes the duct,the suction mass flow rate at the duct decreases with time since the air pressure at the opening of the duct is gradually recovered with time.A drastic change in the mass flow rate at a ventilation duct while a train passes the corresponding ventilation duct,causes a change in the exhaust mass flow rate at other ventilation ducts.Also,when a barrier is placed at the tunnel outlet,the air volume discharge rate at each ventilation duct is greatly increased,i.e.,the barrier placed at the tunnel outlet can improve remarkably the ventilation performance through each duct. 展开更多
关键词 train-induced flow subway tunnel natural ventilation duct ventilation performance dynamic layering method