期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Experimental Analysis of the Flow Characteristics of an Adjustable Critical-Flow Venturi Nozzle
1
作者 Chun Ye Jingjing Gao +4 位作者 Zhihui Wang Weibiao Zheng Yibei Wang Xingkai Zhang Ming Liu 《Fluid Dynamics & Materials Processing》 EI 2023年第3期754-765,共12页
The response of an adjustable critical-flow Venturi nozzle is investigated through a set indoor experiments aimed to determine the related critical flow rate,critical pressure ratio,and discharge coefficient.The effec... The response of an adjustable critical-flow Venturi nozzle is investigated through a set indoor experiments aimed to determine the related critical flow rate,critical pressure ratio,and discharge coefficient.The effect of a variation in the cone displacement and liquid content on the critical flow characteristics is examined in detail and it is shown that the former can be used to effectively adjust the critical flow rate.The critical pressure ratio of the considered nozzle is above 0.85,and the critical flow control deviation of the gas flow is within±3%.Liquid flow can reduce the gas critical mass flow rate accordingly,especially for the cases with larger liquid volume and lower inlet pressure.The set of results and conclusions provided are intended to support the optimization of steam injection techniques in the context of heavy oil recovery processes. 展开更多
关键词 Adjustable critical flow venturi nozzle critical pressure ratio critical mass flow rate gas-liquid two-phase critical flow
下载PDF
Study on Venturi nozzle for gas-liquid two-phase flow metering
2
作者 梁法春 张修刚 +1 位作者 王栋 林宗虎 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2012年第1期107-110,共4页
Experiments were carried out to study gas-liquid two-phase flow through a horizontally mounted Venturi nozzle. The inner diameter of pipe is 25 mm and the throat diameter of Venturi nozzle is 5. 1 mm. The pressure dif... Experiments were carried out to study gas-liquid two-phase flow through a horizontally mounted Venturi nozzle. The inner diameter of pipe is 25 mm and the throat diameter of Venturi nozzle is 5. 1 mm. The pressure difference and pressure loss across the nozzle were measured. It was found that the degree of pressure fluctuation strongly depends on the gas quality. However,the relationship between the standard deviation of pressure difference and the gas quality is not monotonous. Multiple solutions may occur when the relationship was used to determine gas quality. On the other hand,the standard deviation of pressure loss was found to be monotonously correlated to X. This phenomenon was applied to measured gas quality. Also a modified Lin's equation is proposed to calculate the two-phase flow rate. The experimental measurements agree well with the predicted values. 展开更多
关键词 two-phase flow venturi nozzle flow measurement
下载PDF