A wide variety of near-fault strong ground motion records were collected from various tectonic environments worldwide and were used to study the peak value ratio and response spectrum ratio of the vertical to horizont...A wide variety of near-fault strong ground motion records were collected from various tectonic environments worldwide and were used to study the peak value ratio and response spectrum ratio of the vertical to horizontal component of ground motion, focusing on the effect of earthquake magnitude, site conditions, pulse duration, and statistical component. The results show that both the peak value ratio and response spectrum ratio are larger than the 2/3 value prescribed in existing seismic codes, and the relationship between the vertical and horizontal ground motions is comparatively intricate. In addition, the effect of the near-fault ground motions on bridge performance is analyzed, considering both the material nonlinear characteristics and the P-A effect.展开更多
Many studies have focused on horizontal ground motion, resulting in many coherency functions for horizontal ground motion while neglecting related problems arising from vertical ground motion. However, seismic events ...Many studies have focused on horizontal ground motion, resulting in many coherency functions for horizontal ground motion while neglecting related problems arising from vertical ground motion. However, seismic events have demonstrated that the vertical components of ground motion sometimes govern the ultimate failure of structures. In this paper, a vertical coherency function model of spatial ground motion is proposed based on the Hao model and SMART 1 array records, and the validity of the model is demonstrated. The vertical coherency function model of spatial ground motion is also compared with the horizontal coherency function model, indicating that neither model exhibits isotropic characteristics. The value of the vertical coherency function has little correlation with that of the horizontal coherency function. However, the coherence of the vertical ground motion between a pair of stations decreases with their projection distance and the frequency of the ground motion. When the projection distance in the wave direction is greater than 800 meters, the coherency between the two points can be neglected.展开更多
The effect of seawater on vertical ground motions is studied via a theoretical method and then actual offshore ground motion records are analyzed using a statistical method. A theoretical analysis of the effect of sea...The effect of seawater on vertical ground motions is studied via a theoretical method and then actual offshore ground motion records are analyzed using a statistical method. A theoretical analysis of the effect of seawater on incident plane P and SV waves at ocean bottom indicate that on one hand, the affected frequency range of vertical ground motions is prominent due to P wave resonance in the water layer if the impedance ratio between the seawater and the underlying medium is large, but it is greatly suppressed if the impedance ratio is small; on the other hand, for the ocean bottom interface model selected herein, vertical ground motions consisting of mostly P waves are more easily affected by seawater than those dominated by SV waves. The statistical analysis of engineering parameters of offshore ground motion records indicate that:(1) Under the infl uence of softer surface soil at the seafl oor, both horizontal and vertical spectral accelerations of offshore motions are exaggerated at long period components, which leads to the peak spectral values moving to a longer period.(2) The spectral ratios(V/H) of offshore ground motions are much smaller than onshore ground motions near the P wave resonant frequencies in the water layer; and as the period becomes larger, the effect of seawater becomes smaller, which leads to a similar V/H at intermediate periods(near 2 s). These results are consistent with the conclusions of Boore and Smith(1999), but the V/H of offshore motion may be smaller than the onshore ground motions at longer periods(more than 5 s).展开更多
A modified Gauss-Markov model with weighted constraints was constructed by combining satellite altimeter and tide gauge records. Vertical motion rates of nine tide gauge stations around the Bohal Sea and Yellow Sea ar...A modified Gauss-Markov model with weighted constraints was constructed by combining satellite altimeter and tide gauge records. Vertical motion rates of nine tide gauge stations around the Bohal Sea and Yellow Sea are estimated. This is the first time systematic estimates have been derived in this region. Downward trends were seen at the six tide gauge stations located at Tanggu, Longkou, Laohutan, Bayuquan, Xiaochangshan, and Yantai; with vertical motion rates of-1.82±0.50, -1.65±0.46, -0.88±0.42, -0.58±0.62, -0.13±0.43, and -0.01±0.43 mm/yr, respectively. Upward trends were seen at the three tide gauge stations located at Qinhuangdao, Huludao and Chengshantou; with vertical motion rates of 1.12±0.46, 0.55±0.49 and 0.26±0.44 mm/yr, respectively. There was significant subsidence in Tanggu and Longkou, and a rising trend in Qinhuangdao. According to our results, the rate of sea level rise calculated from these tide gauge records can be improved using a more accurate measurement of the land elevation accounting for lifting or subsidence. The model derived can be used to estimate vertical motions of tide gauge stations, and can be widely applied to revise the benchmark levels of tide gauges.展开更多
A hybrid control platform is investigated in this paper to mitigate microvibrations to a group of vibration-sensitive equipment installed in a microelectronics facility subject to nearby road vehicle-induced horizonta...A hybrid control platform is investigated in this paper to mitigate microvibrations to a group of vibration-sensitive equipment installed in a microelectronics facility subject to nearby road vehicle-induced horizontal and vertical ground motions. The hybrid control platform, on which microelectronics equipment is installed, is mounted on a building floor through a series of passive mounts and controlled by hydraulic actuators in both horizontal and vertical directions. The control platform is an elastic body with significant bending modes of vibration, and a sub-optimal control algorithm is used to manipulate the hydraulic actuators with actuator dynamics included. The finite element model and the equations of motion of the coupled platform-building system are then established in the absolute coordinate to facilitate the feedback control and performance evaluation of the platform. The horizontal and vertical ground vibrations at the base of the building induced by nearby moving road vehicles are assumed to be stationary random processes. A typical three-story microelectronics building is selected as a case study. The case study shows that the vertical vibration of the microelectronics building is higher than the horizontal. The use of a hybrid control platform can effectively reduce both horizontal and vertical microvibrations of the microelectronics equipment to the level which satisfies the stringent microscale velocity requirement specified in the Bolt Beranek & Newman (BBN) criteria.展开更多
基金National Natural Science Foundation of China Under Grant No.50278002Dalian Nationalities University PHD Foundation Under Grant No.20066104
文摘A wide variety of near-fault strong ground motion records were collected from various tectonic environments worldwide and were used to study the peak value ratio and response spectrum ratio of the vertical to horizontal component of ground motion, focusing on the effect of earthquake magnitude, site conditions, pulse duration, and statistical component. The results show that both the peak value ratio and response spectrum ratio are larger than the 2/3 value prescribed in existing seismic codes, and the relationship between the vertical and horizontal ground motions is comparatively intricate. In addition, the effect of the near-fault ground motions on bridge performance is analyzed, considering both the material nonlinear characteristics and the P-A effect.
基金Supported by National Natural Science Foundation of China Under Grant No.90715005,No.NCET-07-0186 and No.200802860007
文摘Many studies have focused on horizontal ground motion, resulting in many coherency functions for horizontal ground motion while neglecting related problems arising from vertical ground motion. However, seismic events have demonstrated that the vertical components of ground motion sometimes govern the ultimate failure of structures. In this paper, a vertical coherency function model of spatial ground motion is proposed based on the Hao model and SMART 1 array records, and the validity of the model is demonstrated. The vertical coherency function model of spatial ground motion is also compared with the horizontal coherency function model, indicating that neither model exhibits isotropic characteristics. The value of the vertical coherency function has little correlation with that of the horizontal coherency function. However, the coherence of the vertical ground motion between a pair of stations decreases with their projection distance and the frequency of the ground motion. When the projection distance in the wave direction is greater than 800 meters, the coherency between the two points can be neglected.
基金the 973 Program under Grant No.2011CB013601Basic Science Research Foundation of IEM,CEA under Grant No.2011B02+1 种基金National Natural Science Foundation of China under Grant No.51238012,9121530113,50938006International Science&Technology Cooperation Program of China under Grant No.2012DFA70810
文摘The effect of seawater on vertical ground motions is studied via a theoretical method and then actual offshore ground motion records are analyzed using a statistical method. A theoretical analysis of the effect of seawater on incident plane P and SV waves at ocean bottom indicate that on one hand, the affected frequency range of vertical ground motions is prominent due to P wave resonance in the water layer if the impedance ratio between the seawater and the underlying medium is large, but it is greatly suppressed if the impedance ratio is small; on the other hand, for the ocean bottom interface model selected herein, vertical ground motions consisting of mostly P waves are more easily affected by seawater than those dominated by SV waves. The statistical analysis of engineering parameters of offshore ground motion records indicate that:(1) Under the infl uence of softer surface soil at the seafl oor, both horizontal and vertical spectral accelerations of offshore motions are exaggerated at long period components, which leads to the peak spectral values moving to a longer period.(2) The spectral ratios(V/H) of offshore ground motions are much smaller than onshore ground motions near the P wave resonant frequencies in the water layer; and as the period becomes larger, the effect of seawater becomes smaller, which leads to a similar V/H at intermediate periods(near 2 s). These results are consistent with the conclusions of Boore and Smith(1999), but the V/H of offshore motion may be smaller than the onshore ground motions at longer periods(more than 5 s).
基金supported by the National Natural Science Foundation of China(Grant Nos.4140603241206021&41376014)+4 种基金the National Basic Research Program of China(Grant No.2012CB955601)the National Key Technology R&D Program of China(Grant No.2014BAB12B02)the Key Technology R&D Program of Tianjin(Grant No.14ZCZDSF00012)the Open Fund of the State Key Laboratory of Satellite Ocean Environment Dynamics at the Second Institute of OceanographySOA(Grant No.SOED1305)
文摘A modified Gauss-Markov model with weighted constraints was constructed by combining satellite altimeter and tide gauge records. Vertical motion rates of nine tide gauge stations around the Bohal Sea and Yellow Sea are estimated. This is the first time systematic estimates have been derived in this region. Downward trends were seen at the six tide gauge stations located at Tanggu, Longkou, Laohutan, Bayuquan, Xiaochangshan, and Yantai; with vertical motion rates of-1.82±0.50, -1.65±0.46, -0.88±0.42, -0.58±0.62, -0.13±0.43, and -0.01±0.43 mm/yr, respectively. Upward trends were seen at the three tide gauge stations located at Qinhuangdao, Huludao and Chengshantou; with vertical motion rates of 1.12±0.46, 0.55±0.49 and 0.26±0.44 mm/yr, respectively. There was significant subsidence in Tanggu and Longkou, and a rising trend in Qinhuangdao. According to our results, the rate of sea level rise calculated from these tide gauge records can be improved using a more accurate measurement of the land elevation accounting for lifting or subsidence. The model derived can be used to estimate vertical motions of tide gauge stations, and can be widely applied to revise the benchmark levels of tide gauges.
基金CERG competitive research grant (Polyu 5054/02E) from Research Grants Council of Hong Kong, Area Strategic Development Programmer in Structural Control and Intelligent Buildings from The Hong Kong Polytechnic Universityand the Opening Research Foundation of the Beijing Key Laboratories (EESR2004-2) from Beijing University of Technology.
文摘A hybrid control platform is investigated in this paper to mitigate microvibrations to a group of vibration-sensitive equipment installed in a microelectronics facility subject to nearby road vehicle-induced horizontal and vertical ground motions. The hybrid control platform, on which microelectronics equipment is installed, is mounted on a building floor through a series of passive mounts and controlled by hydraulic actuators in both horizontal and vertical directions. The control platform is an elastic body with significant bending modes of vibration, and a sub-optimal control algorithm is used to manipulate the hydraulic actuators with actuator dynamics included. The finite element model and the equations of motion of the coupled platform-building system are then established in the absolute coordinate to facilitate the feedback control and performance evaluation of the platform. The horizontal and vertical ground vibrations at the base of the building induced by nearby moving road vehicles are assumed to be stationary random processes. A typical three-story microelectronics building is selected as a case study. The case study shows that the vertical vibration of the microelectronics building is higher than the horizontal. The use of a hybrid control platform can effectively reduce both horizontal and vertical microvibrations of the microelectronics equipment to the level which satisfies the stringent microscale velocity requirement specified in the Bolt Beranek & Newman (BBN) criteria.