AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.MET...AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.展开更多
AIM:To compare the effects of scleral buckling using wide-angle viewing systems(WAVS) with that using indirect ophthalmoscope for the treatment of rhegmatogenous retinal detachment.METHODS:The study was a retrospe...AIM:To compare the effects of scleral buckling using wide-angle viewing systems(WAVS) with that using indirect ophthalmoscope for the treatment of rhegmatogenous retinal detachment.METHODS:The study was a retrospective analyses of the medical records of 94 eyes(94 patients) with rhegmatogenous retinal detachment.Among them,47 eyes underwent scleral buckling using WAVS with endoiiluminator(Group W),and 47 eyes underwent scleral buckling using indirect ophthalmoscope(Group I).Surgical durations,primary success rate,best-corrected visual acuities(BCVA),delayed subretinal fluid absorptions and surgical complications were compared between the two groups.RESULTS:At baseline,there were no statistical differences between the two groups in patient's age(P=0.997),gender(P=0.853),symptom duration(P=0.216),BCVA(P=0.389),refractive error(P=0.167),intraocular pressure(P=0.595),the number of retinal breaks(P=0.832),the extent of retinal detachment(P =0.246),subretinal demarcation line(P=0.801),and macular detachment(P=0.811).The follow-up period was 12 mo.The surgical durations in Group W(with or without encircling buckling) were significant shorter than those in Group I(P〈0.001 respectively).The primary success rate was94.27%in Group W,which was similar to that in Group I(92.38%,P=0.931).The BCVA in Group W was better than that in Group I(P〈0.001) at 1-month follow-up visit.However,there were no significant differences between the two groups at 3-month(P=0.221),6-month(P =0.674),and 12-month(P=0.363) follow-up visits respectively.Delayed subretinal fluid absorptions were more common in Group I than in Group W at 1-month(P=0.045) follow-up visit,but there were no significant differences between the two groups at 3-month(P=0.111),6-month(P =1.000) and 12-month follow-up visits respectively.CONCLUSION:Scleral buckling using WAVS can be an alternative choose for rhegmatogenous retinal detachment展开更多
AIM: To assess the optimal conditions for preventing condensation of objective lens during vitrectomy with noncontact wide-angle viewing systems(WAVSs). METHODS: We explored the effectiveness of the coating with o...AIM: To assess the optimal conditions for preventing condensation of objective lens during vitrectomy with noncontact wide-angle viewing systems(WAVSs). METHODS: We explored the effectiveness of the coating with ophthalmic viscoelastic device(OVDs) on the corneal surface and the soaking the objective lens in warm-saline for preventing condensation of objective lens. First, to find the optimal soaking time to keep the objective lens warm, we measured the temperature of objective lens every minute after soaking in warm saline. Second, to find optimal distance between cornea and objective lens, which provide as wide a view as possible and less condensation at the same time, we measured the condensation time with different distances. With the obtained optimal soaking time and distance, we explored the effect of coating cornea with OVDs and soaking objective lens in warm saline on condensation time.RESULTS: One and 5 min of soaking in warm saline was most effective for keeping the lens warm enough(45.1℃±2.1℃ for 1 min and 46.4℃±1.0℃ for 5 min, P=0.109). The mean condensation times for the control group at 1, 3, and 5 mm from corneal surface to objective lens were 1±0.4, 4±1.4, 190±26.1 s, respectively, thus 5 mm was most optimal distance for vitrectomy with WAVSs. For the OVD coating group, the mean condensation times were 1.5±0.3, 13±1.4, and 200±23.9 s at 1, 3, and 5 mm distance and borderline significant compared with control group(P=0.068, 0.051, and 0.063, respectively). With the 1-minute warm saline soaking group, the mean condensation time were extended to 188±34.4, 416±65.7, and 600±121.3 s at 1, 3, and 5 mm distance and statistically significant compared with control(P=0.043, 0.041 and 0.043, respectively).CONCLUSION: OVD coating on corneal surface shows no difference on condensation time with control group. However, soaking the objective lens in warm saline revealed statistically significant extension of condensation time compared to control group. Therefore, keeping the objective lens warm with soaking in warm saline is a simple but effective to prevent condensation of objective lens during vitrectomy. The thermodynamics between objective lens and cornea during vitrectomy warrants further investigation.展开更多
In response to the challenges posed by insufficient real-time performance and suboptimal matching accuracy of traditional feature matching algorithms within automotive panoramic surround view systems,this paper has pr...In response to the challenges posed by insufficient real-time performance and suboptimal matching accuracy of traditional feature matching algorithms within automotive panoramic surround view systems,this paper has proposed a high-performance dimension reduction parallel matching algorithm that integrates Principal Component Analysis(PCA)and Dual-Heap Filtering(DHF).The algorithm employs PCA to map the feature points into the lower-dimensional space and employs the square of Euclidean distance for feature matching,which significantly reduces computational complexity.To ensure the accuracy of feature matching,the algorithm utilizes Dual-Heap Filtering to filter and refine matched point pairs.To further enhance matching speed and make optimal use of computational resources,the algorithm introduces a multi-core parallel matching strategy,greatly elevating the efficiency of feature matching.Compared to Scale-Invariant Feature Transform(SIFT)and Speeded Up Robust Features(SURF),the proposed algorithm reduces matching time by 77%to 80%and concurrently enhances matching accuracy by 5%to 15%.Experimental results demonstrate that the proposed algorithmexhibits outstanding real-time matching performance and accuracy,effectivelymeeting the feature-matching requirements of automotive panoramic surround view systems.展开更多
Distinguished from purely formalistic research methods,iconography pursues the interpretation of the hidden historical and humanistic connotations behind artworks,and is a discipline that combines visual text and cont...Distinguished from purely formalistic research methods,iconography pursues the interpretation of the hidden historical and humanistic connotations behind artworks,and is a discipline that combines visual text and content analysis methods.Combining the three stages of iconography proposed by Panofsky,the paper studies Shizeng Chen’s Viewing Paintings from the perspective of iconography,summarizing the formation and change of the images and contents of the artworks in the cultural system and civilization at that time,as well as their implied ideology,and analyzing the hidden spirit of the times and the historical significance behind them,so as to expound their iconographic significance.Through an in-depth discussion at three levels:pre-pictorial iconographic description,iconographic analysis,and iconographic interpretation,the facts and surface contents reproduced in the images,the traditional level of literary,artistic,and cultural knowledge,as well as the interpretation of the potential meanings are revealed.展开更多
The methods of estimating the minimum allowed value of IFOV (instantaneous field of view) of the detector in a rosette scan system are investigated. The common method for the estimation of IFOV is described. A new met...The methods of estimating the minimum allowed value of IFOV (instantaneous field of view) of the detector in a rosette scan system are investigated. The common method for the estimation of IFOV is described. A new method which uses the maximum distance between two neighboring petals as the estimated value of IFOV is developed and a comparison between the common method and the new method is given. It is concluded that the minimum allowed value of IFOV of rosette scanning is over estimated by the common method while this value can be calculated accurately with the new method.展开更多
基金Supported by National Natural Science Foundation of China(No.81700884)Scientific Research Foundation of National Health and Health Commission(No.WKJ-ZJ-2037)+1 种基金Zhejiang Public Welfare Technology Application Project(No.LGF21H120005)Science and Technology Project of Wenzhou(No.Y20190649).
文摘AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.
基金Supported by the Projects of Henan Health and Family Planning Commission(No.2014005)Henan Health Department(No.201304007)Henan Science and Technology Department(No.142102310110)
文摘AIM:To compare the effects of scleral buckling using wide-angle viewing systems(WAVS) with that using indirect ophthalmoscope for the treatment of rhegmatogenous retinal detachment.METHODS:The study was a retrospective analyses of the medical records of 94 eyes(94 patients) with rhegmatogenous retinal detachment.Among them,47 eyes underwent scleral buckling using WAVS with endoiiluminator(Group W),and 47 eyes underwent scleral buckling using indirect ophthalmoscope(Group I).Surgical durations,primary success rate,best-corrected visual acuities(BCVA),delayed subretinal fluid absorptions and surgical complications were compared between the two groups.RESULTS:At baseline,there were no statistical differences between the two groups in patient's age(P=0.997),gender(P=0.853),symptom duration(P=0.216),BCVA(P=0.389),refractive error(P=0.167),intraocular pressure(P=0.595),the number of retinal breaks(P=0.832),the extent of retinal detachment(P =0.246),subretinal demarcation line(P=0.801),and macular detachment(P=0.811).The follow-up period was 12 mo.The surgical durations in Group W(with or without encircling buckling) were significant shorter than those in Group I(P〈0.001 respectively).The primary success rate was94.27%in Group W,which was similar to that in Group I(92.38%,P=0.931).The BCVA in Group W was better than that in Group I(P〈0.001) at 1-month follow-up visit.However,there were no significant differences between the two groups at 3-month(P=0.221),6-month(P =0.674),and 12-month(P=0.363) follow-up visits respectively.Delayed subretinal fluid absorptions were more common in Group I than in Group W at 1-month(P=0.045) follow-up visit,but there were no significant differences between the two groups at 3-month(P=0.111),6-month(P =1.000) and 12-month follow-up visits respectively.CONCLUSION:Scleral buckling using WAVS can be an alternative choose for rhegmatogenous retinal detachment
文摘AIM: To assess the optimal conditions for preventing condensation of objective lens during vitrectomy with noncontact wide-angle viewing systems(WAVSs). METHODS: We explored the effectiveness of the coating with ophthalmic viscoelastic device(OVDs) on the corneal surface and the soaking the objective lens in warm-saline for preventing condensation of objective lens. First, to find the optimal soaking time to keep the objective lens warm, we measured the temperature of objective lens every minute after soaking in warm saline. Second, to find optimal distance between cornea and objective lens, which provide as wide a view as possible and less condensation at the same time, we measured the condensation time with different distances. With the obtained optimal soaking time and distance, we explored the effect of coating cornea with OVDs and soaking objective lens in warm saline on condensation time.RESULTS: One and 5 min of soaking in warm saline was most effective for keeping the lens warm enough(45.1℃±2.1℃ for 1 min and 46.4℃±1.0℃ for 5 min, P=0.109). The mean condensation times for the control group at 1, 3, and 5 mm from corneal surface to objective lens were 1±0.4, 4±1.4, 190±26.1 s, respectively, thus 5 mm was most optimal distance for vitrectomy with WAVSs. For the OVD coating group, the mean condensation times were 1.5±0.3, 13±1.4, and 200±23.9 s at 1, 3, and 5 mm distance and borderline significant compared with control group(P=0.068, 0.051, and 0.063, respectively). With the 1-minute warm saline soaking group, the mean condensation time were extended to 188±34.4, 416±65.7, and 600±121.3 s at 1, 3, and 5 mm distance and statistically significant compared with control(P=0.043, 0.041 and 0.043, respectively).CONCLUSION: OVD coating on corneal surface shows no difference on condensation time with control group. However, soaking the objective lens in warm saline revealed statistically significant extension of condensation time compared to control group. Therefore, keeping the objective lens warm with soaking in warm saline is a simple but effective to prevent condensation of objective lens during vitrectomy. The thermodynamics between objective lens and cornea during vitrectomy warrants further investigation.
基金the National Natural Science Foundation of China(61803206)the Key R&D Program of Jiangsu Province(BE2022053-2)the Nanjing Forestry University Youth Science and Technology Innovation Fund(CX2018004)for partly funding this project.
文摘In response to the challenges posed by insufficient real-time performance and suboptimal matching accuracy of traditional feature matching algorithms within automotive panoramic surround view systems,this paper has proposed a high-performance dimension reduction parallel matching algorithm that integrates Principal Component Analysis(PCA)and Dual-Heap Filtering(DHF).The algorithm employs PCA to map the feature points into the lower-dimensional space and employs the square of Euclidean distance for feature matching,which significantly reduces computational complexity.To ensure the accuracy of feature matching,the algorithm utilizes Dual-Heap Filtering to filter and refine matched point pairs.To further enhance matching speed and make optimal use of computational resources,the algorithm introduces a multi-core parallel matching strategy,greatly elevating the efficiency of feature matching.Compared to Scale-Invariant Feature Transform(SIFT)and Speeded Up Robust Features(SURF),the proposed algorithm reduces matching time by 77%to 80%and concurrently enhances matching accuracy by 5%to 15%.Experimental results demonstrate that the proposed algorithmexhibits outstanding real-time matching performance and accuracy,effectivelymeeting the feature-matching requirements of automotive panoramic surround view systems.
文摘Distinguished from purely formalistic research methods,iconography pursues the interpretation of the hidden historical and humanistic connotations behind artworks,and is a discipline that combines visual text and content analysis methods.Combining the three stages of iconography proposed by Panofsky,the paper studies Shizeng Chen’s Viewing Paintings from the perspective of iconography,summarizing the formation and change of the images and contents of the artworks in the cultural system and civilization at that time,as well as their implied ideology,and analyzing the hidden spirit of the times and the historical significance behind them,so as to expound their iconographic significance.Through an in-depth discussion at three levels:pre-pictorial iconographic description,iconographic analysis,and iconographic interpretation,the facts and surface contents reproduced in the images,the traditional level of literary,artistic,and cultural knowledge,as well as the interpretation of the potential meanings are revealed.
文摘The methods of estimating the minimum allowed value of IFOV (instantaneous field of view) of the detector in a rosette scan system are investigated. The common method for the estimation of IFOV is described. A new method which uses the maximum distance between two neighboring petals as the estimated value of IFOV is developed and a comparison between the common method and the new method is given. It is concluded that the minimum allowed value of IFOV of rosette scanning is over estimated by the common method while this value can be calculated accurately with the new method.