In recent years,switched inductor(SL)technology,switched capacitor(SC)technology,and switched inductor-capacitor(SL-SC)technology have been widely applied to optimize and improve DC-DC boost converters,which can effec...In recent years,switched inductor(SL)technology,switched capacitor(SC)technology,and switched inductor-capacitor(SL-SC)technology have been widely applied to optimize and improve DC-DC boost converters,which can effectively enhance voltage gain and reduce device stress.To address the issue of low output voltage in current renewable energy power generation systems,this study proposes a novel non-isolated cubic high-gain DC-DC converter based on the traditional quadratic DC-DC boost converter by incorporating a SC and a SL-SC unit.Firstly,the proposed converter’s details are elaborated,including its topology structure,operating mode,voltage gain,device stress,and power loss.Subsequently,a comparative analysis is conducted on the voltage gain and device stress between the proposed converter and other high-gain converters.Then,a closed-loop simulation system is constructed to obtain simulation waveforms of various devices and explore the dynamic performance.Finally,an experimental prototype is built,experimental waveforms are obtained,and the experimental dynamic performance and conversion efficiency are analyzed.The theoretical analysis’s correctness is verified through simulation and experimental results.The proposed converter has advantages such as high voltage gain,low device stress,high conversion efficiency,simple control,and wide input voltage range,achieving a good balance between voltage gain,device stress,and power loss.The proposed converter is well-suited for renewable energy systems and holds theoretical significance and practical value in renewable energy applications.It provides an effective solution to the issue of low output voltage in renewable energy power generation systems.展开更多
The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results ...The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results to the load shading issue that led to the voltage and frequency instability. In additional to that, the high proportions of erratic renewable energy sources can lead to erratic frequency changes which affect the grid stability. In order to reduce this effect, the energy storage system is commonly used in most wind-solar energy systems to balance the voltage and frequency instability during load variations. One of the innovative energy storage systems is the compressed air energy storage system (CAES) for wind and solar hybrid energy system and this technology is the key focus in this research study. The aim of this research was to examine the system configuration of the CAES system through modelling and experimental approach with PID controller design for regulating the voltage and frequency under different load conditions. The essential elements and the entire system have been presented in this work as thorough modelling in the MATLAB/Simulink environment for different load conditions. The developed model was tested through an experimental workbench using the developed prototype of the compressed air storage in the Siemens Lab at DeKUT and explored the consequence of the working parameters on the system proficiency and the model accuracy. The performance of the system for the developed prototype of CAES system was validated using results from an experimental workbench with MATLAB/Simulink R2022b simulation. The modeling and experimental results, shows that the frequency fluctuation and voltage drop of the developed CAES system during load variations was governed by the I/P converter using a PID_Compact controller programed in the TIA Portal V17 software and downloaded into PLC S7 1200. Based on these results, the model can be applied as a basis for the performance assessment of the compressed air energy storage system so as to be included in current technology of wind and solar hybrid energy systems.展开更多
Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of...Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of PMSM. Thus, an inter-turn short-circuit fault(ITSCF) diagnosis method based on high frequency(HF) voltage residual is proposed in this paper with proper HF signal injection. First, the analytical models of PMSM after the ITSCF are deduced. Based on the model, the voltage residual at low frequency(LF) and HF can be obtained. It is revealed that the HF voltage residual has a stronger ITSCF detection capability compared to the LF voltage residual. To obtain optimal fault signature, a 3-phase symmetrical HF voltage is injected into the machine drive system, and the HF voltage residuals are extracted. The fault indicator is defined as the standard deviation of the 3-phase HF voltage residuals. The effectiveness of the proposed ITSCF diagnosis method is verified by experiments on a triple 3-phase PMSM. It is worth noting that no extra hardware equipment is required to implement the proposed method.展开更多
This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive ...This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive and capacitive parasitic components in the converter. The switch devices operate in a zero-voltage soft-switching mode. Consequently, the high voltage and high current spikes caused by parasitic inductors or capacitors oscillation do not occur in this circuit, and the high power loss caused by high frequency switching can be greatly reduced. A large value inductor is adopted between the input capacitor and the switches, thus, this novel converter shares the benefits of both voltage-type and current-type circuits simultaneously, and there are no needs of dead time between two switches. The working principles in different modes are introduced. Results of simulation and experiments operated at around 1 MHz frequency verify the validity of parasitic components absorption and show that this convener is competent for super high frequency applications.展开更多
This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency o...This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency of timer output waveform which is measured using a digital storage oscillator(DSO)is almost linearly proportional to the applied input voltage.Hence we obtain a linear relationship between the frequency of timer output waveform and the input voltage.Because of its quasi-digital output,the main advantages of this developed converter are linear input-output relationship,small size,easy portabilityand high cost performance.In addition,the timer output waveform can be directly interfaced with personal computer or microprocessor/microcontroller for further processing of the input voltage signal without intervening any analog-to-digital converter(ADC).展开更多
The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by syn...The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by synchronizing their output voltage with the one at the point of common coupling. In the circumstances, a concept of Virtual Synchronous Machine (VSM) is proposed, where the self-commutated power converters are emulating synchronous generators. This paper describes a converter control to contribute to enhancing the synchronizing torque. The proposed control is similar to the VSM but it simply realizes active power trades among power generation units including converter-based generators by modulating phase angles of their output voltages. Therefore, it can provide an effective support to regulate the system frequency where the total rated power of the converter-based generators increases as much as the one of conventional rotating generators like a microgrid. This paper especially focuses on its robustness where the number of converter-based generators is increased or they are dispersed in the power network. The effectiveness is verified by simulation study based on instantaneous values.展开更多
As is well known, there exists a tradeoff between the breakdown voltage BVcEO and the cut-off frequency fT for a standard heterojunction bipolar transistor (HBT). In this paper, this tradeoff is alleviated by collec...As is well known, there exists a tradeoff between the breakdown voltage BVcEO and the cut-off frequency fT for a standard heterojunction bipolar transistor (HBT). In this paper, this tradeoff is alleviated by collector doping engineering in the SiGe HBT by utilizing a novel composite of P+ and N- doping layers inside the collector-base (CB) space-charge region (SCR). Compared with the single N-type collector, the introduction of the thin P+ layers provides a reverse electric field weakening the electric field near the CB metallurgical junction without changing the field direction, and the thin N layer further effectively lowers the electric field near the CB metallurgical junction. As a result, the electron temperature near the CB metallurgical junction is lowered, consequently suppressing the impact ionization, thus BVcEO is improved with a slight degradation in fT. The results show that the product of fTXBVcEo is improved from 309.51 GHz.V to 326.35 GHz.V.展开更多
The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capabi...The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capability for nodal-power control.To maintain the system frequency and voltage magnitude around rated values,a new multi-objective optimization model for both voltage and frequency control is proposed.Moreover,a great similarity between the multiobjective optimization and game problems appears.To reduce the strong subjectivity of the traditional methods,the idea and method of the game theory are introduced into the solution.According to the present situational data and analysis of the voltage and frequency sensitivities to nodal-power variations,the design variables involved in the voltage and frequency control are classified into two strategy spaces for players using hierarchical clustering.Finally,the effectiveness and rationality of the proposed control are verified in MATLAB.展开更多
To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery sys...To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery system, back-up diesel generator, etc., Isolated MicroGrid, which usually uses the inverter to maintain voltage and frequency of the system, is very weak in terms of voltage and frequency stability compared to the large-scale electrical power system. If wind turbine generator is applied to this weak power system, it could experience many problems in terms of maintaining its voltage and frequency. In this paper, the measurement result of voltage and frequency is presented for MicroGrid, which consists of the Wind Turbine Generator adopting the induction generator and the battery system. MicroGrid’s voltage waveform distortion and Wind Turbine Generator’s output oscillation problems are analyzed using PSCAD/EMTDC. Based on the analyzed result, the importance of type and capacity choice has been suggested in case the Wind Turbine Generator is applied to the Isolated MicroGrid.展开更多
Thick CrN coatings were deposited on Si (111) substrates by electron source assisted mid-frequency magnetron sputtering working at 40 kHz. The deposition rate, structure, and microhardness of the coatings were stron...Thick CrN coatings were deposited on Si (111) substrates by electron source assisted mid-frequency magnetron sputtering working at 40 kHz. The deposition rate, structure, and microhardness of the coatings were strongly influenced by the negative bias voltage (Vb). The deposition rate reached 8.96 μm/h at a Vb of -150 V. X-ray diffraction measurement revealed strong CrN (200) orientation for films prepared at low bias voltages. At a high bias voltage of Vb less than -25 V both CrN (200) and (111) were observed. Large and homogeneous grains were observed by both atomic force microscopy and scanning electron microscopy in samples prepared under optimal conditions. The samples exhibited a fibrous microstructure for a low bias voltage and a columnar structure for VD less than -150 V.展开更多
The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficie...The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems.The objective of this paper is to present the design,implementation,and testing of a compact multi-port solid-state transformer for microgrid integration applications.The proposed system has a four-port transformer and four converters connected to the ports.The transformer has four windings integrated on a single common core.Thus,it can integrate different renewable energy resources and energy storage systems.Each port has a rated power of 25 kW,and the switching frequency is pushed to 50 k Hz.The ports are chosen to represent a realistic industrial microgrid model consisting of grid,energy storage system,photovoltaic system,and load.The grid port is designed to operate at 4.16 k VAC corresponding to 7.2 kV DC bus voltage,while the other three ports operate at 500 VDC.Moreover,the grid,energy storage and photovoltaic ports are active ports with dual active bridge topologies,while the load port is a passive port with full bridge rectifier one.The proposed design is first validated with simulation results,and then the proposed transformer is implemented and tested.Experimental results show that the designed system is suitable for 4.16 k VAC medium voltage grid integration.展开更多
Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations ma...Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.展开更多
For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.Ho...For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.展开更多
The electrical and thermal characterization of near-surface electrical discharge plasma driven by radio frequency voltage are investigated experimentally in this paper. The influences of operating pressure, electrode ...The electrical and thermal characterization of near-surface electrical discharge plasma driven by radio frequency voltage are investigated experimentally in this paper. The influences of operating pressure, electrode distance, and duty cycle on the discharge are studied. When pressure reaches 60 Ton. (1 Torr= 1.33322 x 102 Pa) the transition from diffuse glow mode to constricted mode occurs. With the operating pressure varying from 10 Tort to 60 Torr, the discharge energy calculated from the charge-voltage (Q-V) Lissajous figure decreases rapidly, while it remains unchanged between 60 Torr and 460 Torr. Under certain experimental conditions, there exists an optimized electrode distance (8 mm). As the duty cycle of applied voltage increases, the voltage-current waveforms and Q-V Lissajous figures show no distinct changes.展开更多
In this letter, a scheduling scheme based on Dynamic Frequency Clocking (DFC) and multiple voltages is proposed for low power designs under the timing and the resource constraints. Unlike the conventional methods at h...In this letter, a scheduling scheme based on Dynamic Frequency Clocking (DFC) and multiple voltages is proposed for low power designs under the timing and the resource constraints. Unlike the conventional methods at high level synthesis where only voltages of nodes were considered, the scheme based on a gain function considers both voltage and frequency simultaneously to reduce energy consumption. Experiments with a number of DSP benchmarks show that the proposed scheme achieves an effective energy reduction.展开更多
For dielectric barrier discharge(DBD)driven by AC voltage in helium at atmospheric,the relationship between the breakdown voltage and the driving frequency is experimentally investigated using a pair of parallel elect...For dielectric barrier discharge(DBD)driven by AC voltage in helium at atmospheric,the relationship between the breakdown voltage and the driving frequency is experimentally investigated using a pair of parallel electrodes.The gap between the electrodes is 1 mm,4 mm,7 mm,and 10 mm,respectively.Meanwhile with an increment of 2 kHz,the applied AC voltage varies from 12 kHz to 30 kHz.In each experiment,the driving voltage increases slowly,till the helium-filled gap breaks down.Based on a number of experimental results and further analyses,conclusions are obtained as follows.(1)For a small gap(1 mm),the voltage that triggers the first breakdown(Uf)is close to the one that sustains steady breakdowns(Us).However,in the larger gaps(4,7,and 10 mm),Uf is obviously larger than Us.(2)For a fixed gap,Uf does not change significantly with the driving frequency,whereas in the gaps except the 1 mm one,Us drastically decreases with the increase of driving frequency.(3)The motion of residual space charges and the dissipation of positive column,two reasonable factors that explains asymmetrical discharges,are also main reasons for the effect of the driving frequency on the breakdown voltages.展开更多
Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series res...Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series resistance(Rs), donor concentration(Nd), and dielectric characterization depending on frequency or voltage. These parameters are acquired by use of impedance spectroscopy measurements at frequencies ranging from 10 k Hz to 1 MHz and the direct current(DC) bias voltages in a range from-2 V to +2 V at room temperature are used. The main electrical parameters and dielectric parameters,such as dielectric constant(ε"), dielectric loss(ε"), loss tangent(tan δ), the real and imaginary parts of electric modulus(M and M), and alternating current(AC) electrical conductivity(σ) are affected by changing voltage and frequency. The characterizations show that some main electrical parameters usually decrease with increasing frequency because charge carriers at surface states have not enough time to fallow an external AC signal at high frequencies, and all dielectric parameters strongly depend on the voltage and frequency especially in the depletion and accumulation regions. Consequently, it can be concluded that interfacial polarization and interface charges can easily follow AC signal at low frequencies.展开更多
In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling techniqu...In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks.展开更多
A circuit configuration and a circuit topologic family of the novel forward mode AC/AC converters with high frequency link are presented. The circuit configuration is constituted of input cycloconverter, high frequenc...A circuit configuration and a circuit topologic family of the novel forward mode AC/AC converters with high frequency link are presented. The circuit configuration is constituted of input cycloconverter, high frequency transformer, output cycloconverter, input and output filters. The circuit topologic family includes eight circuit topologies, such as full-bridge-full-wave mode, etc. The bi-polarity phase-shifted control strategy and steady principles are thoroughly investigated. The output characteristics are obtained. By using the bi-polarity phase-shifted control strategy with phase-shifted control between the output cycloconveter and the input cycloconverter, commutation overlap period of the output cycloconverter, and polarity selection of the output filtering inductance current and the input voltage, the leakage inductance energy and the output filtering inductance current are naturally commutated, and surge voltage and surge current of the cycloconverters are overcome. The converters have such advantages as simple topology, two-stage power conversions(LFAC/HFAC/LFAC), bi-directional power flow, high frequency electrical isolation, good output waveforms, and strong ability to stabilize voltage. The converters lay key technical foundation on a new-type of regulated sinusoidal AC power supplies and electronic transformers. The correction and advancement of the converters are well verified by a principle test.展开更多
Phase shifted converter realizes zero voltage switching (ZVS) with the use of leakage inductance of the main transformer, however, the realization of ZVS for lagging bridge leg is difficult. This paper proposes a c...Phase shifted converter realizes zero voltage switching (ZVS) with the use of leakage inductance of the main transformer, however, the realization of ZVS for lagging bridge leg is difficult. This paper proposes a current enhanced principle, and based on the principle, a novel phase shifted converter is proposed, which adds an auxi liary resonant net to the conventional full bridge converter to help the lagging bridge leg to realize ZVS. The principle and the design of the novel converter are analyzed, and the simulational and experimental results verify the principle.展开更多
基金This work was supported by China Railway Corporation Science and Technology Research and Development Project(P2021J038).
文摘In recent years,switched inductor(SL)technology,switched capacitor(SC)technology,and switched inductor-capacitor(SL-SC)technology have been widely applied to optimize and improve DC-DC boost converters,which can effectively enhance voltage gain and reduce device stress.To address the issue of low output voltage in current renewable energy power generation systems,this study proposes a novel non-isolated cubic high-gain DC-DC converter based on the traditional quadratic DC-DC boost converter by incorporating a SC and a SL-SC unit.Firstly,the proposed converter’s details are elaborated,including its topology structure,operating mode,voltage gain,device stress,and power loss.Subsequently,a comparative analysis is conducted on the voltage gain and device stress between the proposed converter and other high-gain converters.Then,a closed-loop simulation system is constructed to obtain simulation waveforms of various devices and explore the dynamic performance.Finally,an experimental prototype is built,experimental waveforms are obtained,and the experimental dynamic performance and conversion efficiency are analyzed.The theoretical analysis’s correctness is verified through simulation and experimental results.The proposed converter has advantages such as high voltage gain,low device stress,high conversion efficiency,simple control,and wide input voltage range,achieving a good balance between voltage gain,device stress,and power loss.The proposed converter is well-suited for renewable energy systems and holds theoretical significance and practical value in renewable energy applications.It provides an effective solution to the issue of low output voltage in renewable energy power generation systems.
文摘The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results to the load shading issue that led to the voltage and frequency instability. In additional to that, the high proportions of erratic renewable energy sources can lead to erratic frequency changes which affect the grid stability. In order to reduce this effect, the energy storage system is commonly used in most wind-solar energy systems to balance the voltage and frequency instability during load variations. One of the innovative energy storage systems is the compressed air energy storage system (CAES) for wind and solar hybrid energy system and this technology is the key focus in this research study. The aim of this research was to examine the system configuration of the CAES system through modelling and experimental approach with PID controller design for regulating the voltage and frequency under different load conditions. The essential elements and the entire system have been presented in this work as thorough modelling in the MATLAB/Simulink environment for different load conditions. The developed model was tested through an experimental workbench using the developed prototype of the compressed air storage in the Siemens Lab at DeKUT and explored the consequence of the working parameters on the system proficiency and the model accuracy. The performance of the system for the developed prototype of CAES system was validated using results from an experimental workbench with MATLAB/Simulink R2022b simulation. The modeling and experimental results, shows that the frequency fluctuation and voltage drop of the developed CAES system during load variations was governed by the I/P converter using a PID_Compact controller programed in the TIA Portal V17 software and downloaded into PLC S7 1200. Based on these results, the model can be applied as a basis for the performance assessment of the compressed air energy storage system so as to be included in current technology of wind and solar hybrid energy systems.
基金supported in part by the Jiangsu Carbon Peak Carbon Neutralization Science and Technology Innovation Special Fund under Grant BE2022032-1National Natural Science Foundation of China under Grant 52277035, Grant 51937006 and Grant 51907028the “SEU Zhishan Young Scholars” Program of Southeast University。
文摘Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of PMSM. Thus, an inter-turn short-circuit fault(ITSCF) diagnosis method based on high frequency(HF) voltage residual is proposed in this paper with proper HF signal injection. First, the analytical models of PMSM after the ITSCF are deduced. Based on the model, the voltage residual at low frequency(LF) and HF can be obtained. It is revealed that the HF voltage residual has a stronger ITSCF detection capability compared to the LF voltage residual. To obtain optimal fault signature, a 3-phase symmetrical HF voltage is injected into the machine drive system, and the HF voltage residuals are extracted. The fault indicator is defined as the standard deviation of the 3-phase HF voltage residuals. The effectiveness of the proposed ITSCF diagnosis method is verified by experiments on a triple 3-phase PMSM. It is worth noting that no extra hardware equipment is required to implement the proposed method.
文摘This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive and capacitive parasitic components in the converter. The switch devices operate in a zero-voltage soft-switching mode. Consequently, the high voltage and high current spikes caused by parasitic inductors or capacitors oscillation do not occur in this circuit, and the high power loss caused by high frequency switching can be greatly reduced. A large value inductor is adopted between the input capacitor and the switches, thus, this novel converter shares the benefits of both voltage-type and current-type circuits simultaneously, and there are no needs of dead time between two switches. The working principles in different modes are introduced. Results of simulation and experiments operated at around 1 MHz frequency verify the validity of parasitic components absorption and show that this convener is competent for super high frequency applications.
文摘This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency of timer output waveform which is measured using a digital storage oscillator(DSO)is almost linearly proportional to the applied input voltage.Hence we obtain a linear relationship between the frequency of timer output waveform and the input voltage.Because of its quasi-digital output,the main advantages of this developed converter are linear input-output relationship,small size,easy portabilityand high cost performance.In addition,the timer output waveform can be directly interfaced with personal computer or microprocessor/microcontroller for further processing of the input voltage signal without intervening any analog-to-digital converter(ADC).
文摘The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by synchronizing their output voltage with the one at the point of common coupling. In the circumstances, a concept of Virtual Synchronous Machine (VSM) is proposed, where the self-commutated power converters are emulating synchronous generators. This paper describes a converter control to contribute to enhancing the synchronizing torque. The proposed control is similar to the VSM but it simply realizes active power trades among power generation units including converter-based generators by modulating phase angles of their output voltages. Therefore, it can provide an effective support to regulate the system frequency where the total rated power of the converter-based generators increases as much as the one of conventional rotating generators like a microgrid. This paper especially focuses on its robustness where the number of converter-based generators is increased or they are dispersed in the power network. The effectiveness is verified by simulation study based on instantaneous values.
基金supported by the National Natural Science Foundation of China(Grant Nos.60776051,61006059,and 61006044)the Beijing Municipal Natural Science Foundation,China(Grant Nos.4142007,4143059,4082007,and 4122014)the Beijing Municipal Education Committee,China(Grant Nos.KM200710005015 and KM200910005001)
文摘As is well known, there exists a tradeoff between the breakdown voltage BVcEO and the cut-off frequency fT for a standard heterojunction bipolar transistor (HBT). In this paper, this tradeoff is alleviated by collector doping engineering in the SiGe HBT by utilizing a novel composite of P+ and N- doping layers inside the collector-base (CB) space-charge region (SCR). Compared with the single N-type collector, the introduction of the thin P+ layers provides a reverse electric field weakening the electric field near the CB metallurgical junction without changing the field direction, and the thin N layer further effectively lowers the electric field near the CB metallurgical junction. As a result, the electron temperature near the CB metallurgical junction is lowered, consequently suppressing the impact ionization, thus BVcEO is improved with a slight degradation in fT. The results show that the product of fTXBVcEo is improved from 309.51 GHz.V to 326.35 GHz.V.
基金the National Key Research and Development Program of China(Basic Research Class)(No.2017YFB0903000)the National Natural Science Foundation of China(No.U1909201).
文摘The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capability for nodal-power control.To maintain the system frequency and voltage magnitude around rated values,a new multi-objective optimization model for both voltage and frequency control is proposed.Moreover,a great similarity between the multiobjective optimization and game problems appears.To reduce the strong subjectivity of the traditional methods,the idea and method of the game theory are introduced into the solution.According to the present situational data and analysis of the voltage and frequency sensitivities to nodal-power variations,the design variables involved in the voltage and frequency control are classified into two strategy spaces for players using hierarchical clustering.Finally,the effectiveness and rationality of the proposed control are verified in MATLAB.
文摘To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery system, back-up diesel generator, etc., Isolated MicroGrid, which usually uses the inverter to maintain voltage and frequency of the system, is very weak in terms of voltage and frequency stability compared to the large-scale electrical power system. If wind turbine generator is applied to this weak power system, it could experience many problems in terms of maintaining its voltage and frequency. In this paper, the measurement result of voltage and frequency is presented for MicroGrid, which consists of the Wind Turbine Generator adopting the induction generator and the battery system. MicroGrid’s voltage waveform distortion and Wind Turbine Generator’s output oscillation problems are analyzed using PSCAD/EMTDC. Based on the analyzed result, the importance of type and capacity choice has been suggested in case the Wind Turbine Generator is applied to the Isolated MicroGrid.
基金supported by National Natural Science Foundation of China(Nos.10435060,10675095)
文摘Thick CrN coatings were deposited on Si (111) substrates by electron source assisted mid-frequency magnetron sputtering working at 40 kHz. The deposition rate, structure, and microhardness of the coatings were strongly influenced by the negative bias voltage (Vb). The deposition rate reached 8.96 μm/h at a Vb of -150 V. X-ray diffraction measurement revealed strong CrN (200) orientation for films prepared at low bias voltages. At a high bias voltage of Vb less than -25 V both CrN (200) and (111) were observed. Large and homogeneous grains were observed by both atomic force microscopy and scanning electron microscopy in samples prepared under optimal conditions. The samples exhibited a fibrous microstructure for a low bias voltage and a columnar structure for VD less than -150 V.
基金supported by the National Science Foundation under Grant No.1650470,GRAPES I/UCRC program。
文摘The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems.The objective of this paper is to present the design,implementation,and testing of a compact multi-port solid-state transformer for microgrid integration applications.The proposed system has a four-port transformer and four converters connected to the ports.The transformer has four windings integrated on a single common core.Thus,it can integrate different renewable energy resources and energy storage systems.Each port has a rated power of 25 kW,and the switching frequency is pushed to 50 k Hz.The ports are chosen to represent a realistic industrial microgrid model consisting of grid,energy storage system,photovoltaic system,and load.The grid port is designed to operate at 4.16 k VAC corresponding to 7.2 kV DC bus voltage,while the other three ports operate at 500 VDC.Moreover,the grid,energy storage and photovoltaic ports are active ports with dual active bridge topologies,while the load port is a passive port with full bridge rectifier one.The proposed design is first validated with simulation results,and then the proposed transformer is implemented and tested.Experimental results show that the designed system is suitable for 4.16 k VAC medium voltage grid integration.
基金This work is jointly supported by the National Key R&D Programme of China(No.2017YFB0902000)the National Natural Science Foundation of China(No.U1766206)the Science and Technology Programme of the State Grid Corporation(No.52110418000P).
文摘Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.
基金supported by the National Key R&D Program of China(2017YFB0902704)the Science and Technology Project of SGCC(GY71-15-048)
文摘For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11472306,51407197,and 51507187)
文摘The electrical and thermal characterization of near-surface electrical discharge plasma driven by radio frequency voltage are investigated experimentally in this paper. The influences of operating pressure, electrode distance, and duty cycle on the discharge are studied. When pressure reaches 60 Ton. (1 Torr= 1.33322 x 102 Pa) the transition from diffuse glow mode to constricted mode occurs. With the operating pressure varying from 10 Tort to 60 Torr, the discharge energy calculated from the charge-voltage (Q-V) Lissajous figure decreases rapidly, while it remains unchanged between 60 Torr and 460 Torr. Under certain experimental conditions, there exists an optimized electrode distance (8 mm). As the duty cycle of applied voltage increases, the voltage-current waveforms and Q-V Lissajous figures show no distinct changes.
基金the Natural Science Foundation of Hei- longjiang Province, China (F2004-17).
文摘In this letter, a scheduling scheme based on Dynamic Frequency Clocking (DFC) and multiple voltages is proposed for low power designs under the timing and the resource constraints. Unlike the conventional methods at high level synthesis where only voltages of nodes were considered, the scheme based on a gain function considers both voltage and frequency simultaneously to reduce energy consumption. Experiments with a number of DSP benchmarks show that the proposed scheme achieves an effective energy reduction.
基金Project supported by Fundamental Research Fund for the Central Universities of Ministry of Education of China(2011ZM0016)State Key Laboratory of Electrical Insulation and Power Equipment(EIPE10210)
文摘For dielectric barrier discharge(DBD)driven by AC voltage in helium at atmospheric,the relationship between the breakdown voltage and the driving frequency is experimentally investigated using a pair of parallel electrodes.The gap between the electrodes is 1 mm,4 mm,7 mm,and 10 mm,respectively.Meanwhile with an increment of 2 kHz,the applied AC voltage varies from 12 kHz to 30 kHz.In each experiment,the driving voltage increases slowly,till the helium-filled gap breaks down.Based on a number of experimental results and further analyses,conclusions are obtained as follows.(1)For a small gap(1 mm),the voltage that triggers the first breakdown(Uf)is close to the one that sustains steady breakdowns(Us).However,in the larger gaps(4,7,and 10 mm),Uf is obviously larger than Us.(2)For a fixed gap,Uf does not change significantly with the driving frequency,whereas in the gaps except the 1 mm one,Us drastically decreases with the increase of driving frequency.(3)The motion of residual space charges and the dissipation of positive column,two reasonable factors that explains asymmetrical discharges,are also main reasons for the effect of the driving frequency on the breakdown voltages.
文摘Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series resistance(Rs), donor concentration(Nd), and dielectric characterization depending on frequency or voltage. These parameters are acquired by use of impedance spectroscopy measurements at frequencies ranging from 10 k Hz to 1 MHz and the direct current(DC) bias voltages in a range from-2 V to +2 V at room temperature are used. The main electrical parameters and dielectric parameters,such as dielectric constant(ε"), dielectric loss(ε"), loss tangent(tan δ), the real and imaginary parts of electric modulus(M and M), and alternating current(AC) electrical conductivity(σ) are affected by changing voltage and frequency. The characterizations show that some main electrical parameters usually decrease with increasing frequency because charge carriers at surface states have not enough time to fallow an external AC signal at high frequencies, and all dielectric parameters strongly depend on the voltage and frequency especially in the depletion and accumulation regions. Consequently, it can be concluded that interfacial polarization and interface charges can easily follow AC signal at low frequencies.
文摘In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks.
文摘A circuit configuration and a circuit topologic family of the novel forward mode AC/AC converters with high frequency link are presented. The circuit configuration is constituted of input cycloconverter, high frequency transformer, output cycloconverter, input and output filters. The circuit topologic family includes eight circuit topologies, such as full-bridge-full-wave mode, etc. The bi-polarity phase-shifted control strategy and steady principles are thoroughly investigated. The output characteristics are obtained. By using the bi-polarity phase-shifted control strategy with phase-shifted control between the output cycloconveter and the input cycloconverter, commutation overlap period of the output cycloconverter, and polarity selection of the output filtering inductance current and the input voltage, the leakage inductance energy and the output filtering inductance current are naturally commutated, and surge voltage and surge current of the cycloconverters are overcome. The converters have such advantages as simple topology, two-stage power conversions(LFAC/HFAC/LFAC), bi-directional power flow, high frequency electrical isolation, good output waveforms, and strong ability to stabilize voltage. The converters lay key technical foundation on a new-type of regulated sinusoidal AC power supplies and electronic transformers. The correction and advancement of the converters are well verified by a principle test.
文摘Phase shifted converter realizes zero voltage switching (ZVS) with the use of leakage inductance of the main transformer, however, the realization of ZVS for lagging bridge leg is difficult. This paper proposes a current enhanced principle, and based on the principle, a novel phase shifted converter is proposed, which adds an auxi liary resonant net to the conventional full bridge converter to help the lagging bridge leg to realize ZVS. The principle and the design of the novel converter are analyzed, and the simulational and experimental results verify the principle.