In our previous work, the reactive dividing wall column(RDWC) was proposed and proved to be effective for selective hydrogenation and separation of C3 stream. In the present paper, the dynamics and control of the prop...In our previous work, the reactive dividing wall column(RDWC) was proposed and proved to be effective for selective hydrogenation and separation of C3 stream. In the present paper, the dynamics and control of the proposed RDWC are investigated. Four control structures including composition and temperature controls are proposed. The feed forward controllers are employed in the four control strategies to shorten the dynamic response time, reduce the maximum deviations and offer an immediate adjustment. The control structures are compared by applying them into the RDWC system with 20% disturbances in both the feed flow rate and the feed compositions, and the results are discussed.展开更多
Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in th...Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time.展开更多
Based on the three-term decomposition model for turbulent flows, the fundamental equations for quasi-periodic motions are obtained, and the approximate analytical solutions of these second-order nonlinear partial diff...Based on the three-term decomposition model for turbulent flows, the fundamental equations for quasi-periodic motions are obtained, and the approximate analytical solutions of these second-order nonlinear partial differential equations are derived by using the match method. The effects on the mo- mentum, heat and mass transport processes in the wall turbulent flows can be estimated approximately.展开更多
基金Supported by the National Basic Research Program of China(2012CB720500)the National Supporting Research Program of China(2013BAA03B01)+1 种基金the National Natural Science Foundation of China(21176178)China Scholarship Council(CSC[2015]3022)
文摘In our previous work, the reactive dividing wall column(RDWC) was proposed and proved to be effective for selective hydrogenation and separation of C3 stream. In the present paper, the dynamics and control of the proposed RDWC are investigated. Four control structures including composition and temperature controls are proposed. The feed forward controllers are employed in the four control strategies to shorten the dynamic response time, reduce the maximum deviations and offer an immediate adjustment. The control structures are compared by applying them into the RDWC system with 20% disturbances in both the feed flow rate and the feed compositions, and the results are discussed.
基金Supported by Open Research Project of State Key Laboratory of Chemical Engineering(Grant No.SKL-Ch E-16B06)
文摘Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time.
文摘Based on the three-term decomposition model for turbulent flows, the fundamental equations for quasi-periodic motions are obtained, and the approximate analytical solutions of these second-order nonlinear partial differential equations are derived by using the match method. The effects on the mo- mentum, heat and mass transport processes in the wall turbulent flows can be estimated approximately.