Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial l...Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial low power heat into“renewable heat”useful to enhance the efficiency of the system is essential and actual innovation in the field of worldwide environmental protection.By introducing and defining the terminology of low-potential,“renewable”,“green heat”has created a new,parallel category of research in the energy sector.Traditional co-generation systems produce heat for space heating and hot water and generate electricity.Moving to tri-generation allows growing demand for air conditioning for homes,offices and commercial spaces such as server rooms and switchboards to be met simultaneously or on a seasonal basis.Tri-generation,or combined cooling,heat and power,is the process by which some of the heat produced by a co-generation plant is used to generate chilled water for air conditioning or refrigeration.Usually an absorption chiller is linked to the plant to provide this functionality.The technical solution is related to the new efficient manner and system of simultaneous generation of heat/cold from multiple heat sources,which has not yet been known,but in practice required.New system also enables advantageous utilization of solar power in supporting of the cooling output.The innovative system can be operated also within the existing central heating distribution systems.展开更多
A new waste heat recovery system is presented to recover exhausted steam waste heat from the steam turbine by absorption heat pump(AHP) in a gas-steam combined cycle(GSCC) power plant. The system can decrease energy c...A new waste heat recovery system is presented to recover exhausted steam waste heat from the steam turbine by absorption heat pump(AHP) in a gas-steam combined cycle(GSCC) power plant. The system can decrease energy consumption and further improve the energy utilization. The performance evaluation criteria are calculated, and exergy analysis for key components are implemented in terms of the energy and exergy analysis theory. Besides, the change of these criteria is also revealed before and after modification. The net power output approximately increases by 21738 kW, and equivalent coal consumption decreases by 5.58 g/kWh. A 1.81% and 1.92% increase in the thermal and exergy efficiency is respectively obtained in the new integrated system as the heating load is 401095 kJ at 100% condition. Meanwhile, the appropriate extraction parameters for heating have been also analyzed in the two systems. The proposed scheme can not only save energy consumption but also reduce emission and gain great economic benefit, which is proven to be a huge potential for practical application.展开更多
In the present study,the thermodynamic and economic performance of a combined thermodynamic cycle formed by an ORC and a Kalina cycle,which can simultaneously recover waste heat of exhaust gas and cooling water of mar...In the present study,the thermodynamic and economic performance of a combined thermodynamic cycle formed by an ORC and a Kalina cycle,which can simultaneously recover waste heat of exhaust gas and cooling water of marine engine,has been analyzed.Two typical marine engines are selected to be the waste heat source.Six economic indicators are used to analyze the economic performance of this combined thermodynamic cycle system with different marine engine load and under practical comprehensive operating condition of marine engine.The results of the present study show that the combined thermodynamic cycle system with R123 as organic working fluid has the best performance.The system with cis-butene has the worst economic performance.Under practical comprehensive operating conditions of ships,R123 has the shortest Payback Periods,which are 8.51 years and 8.14 years for 8 S70 ME-C10.5 engine and 5G95 ME-C10.5 engine,respectively.Correspondingly,payback Periods of Cyclopentane are 11.95 years and 11.90 years.The above values are much shorter than 25 years which are the lifetime of a marine ship.Under practical comprehensive operating conditions of ships,the combined cycle system can provide output power which is at least equivalent to 25%of engine power.Considering that R123 will be phased out in near future,cyclopentane may be its good successor.Cyclopentane can be used safely by correct handling and installing according to manufacturer's instructions.展开更多
文摘Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial low power heat into“renewable heat”useful to enhance the efficiency of the system is essential and actual innovation in the field of worldwide environmental protection.By introducing and defining the terminology of low-potential,“renewable”,“green heat”has created a new,parallel category of research in the energy sector.Traditional co-generation systems produce heat for space heating and hot water and generate electricity.Moving to tri-generation allows growing demand for air conditioning for homes,offices and commercial spaces such as server rooms and switchboards to be met simultaneously or on a seasonal basis.Tri-generation,or combined cooling,heat and power,is the process by which some of the heat produced by a co-generation plant is used to generate chilled water for air conditioning or refrigeration.Usually an absorption chiller is linked to the plant to provide this functionality.The technical solution is related to the new efficient manner and system of simultaneous generation of heat/cold from multiple heat sources,which has not yet been known,but in practice required.New system also enables advantageous utilization of solar power in supporting of the cooling output.The innovative system can be operated also within the existing central heating distribution systems.
基金supported by National Natural Science Foundation of China No. 51274224the China Scholarship Council (CSC) (No. 201706440092)
文摘A new waste heat recovery system is presented to recover exhausted steam waste heat from the steam turbine by absorption heat pump(AHP) in a gas-steam combined cycle(GSCC) power plant. The system can decrease energy consumption and further improve the energy utilization. The performance evaluation criteria are calculated, and exergy analysis for key components are implemented in terms of the energy and exergy analysis theory. Besides, the change of these criteria is also revealed before and after modification. The net power output approximately increases by 21738 kW, and equivalent coal consumption decreases by 5.58 g/kWh. A 1.81% and 1.92% increase in the thermal and exergy efficiency is respectively obtained in the new integrated system as the heating load is 401095 kJ at 100% condition. Meanwhile, the appropriate extraction parameters for heating have been also analyzed in the two systems. The proposed scheme can not only save energy consumption but also reduce emission and gain great economic benefit, which is proven to be a huge potential for practical application.
基金funded by the National Natural Science Foundation of China(Grant No.51506001)Beijing Municipal Education Commission(KM201710005029)。
文摘In the present study,the thermodynamic and economic performance of a combined thermodynamic cycle formed by an ORC and a Kalina cycle,which can simultaneously recover waste heat of exhaust gas and cooling water of marine engine,has been analyzed.Two typical marine engines are selected to be the waste heat source.Six economic indicators are used to analyze the economic performance of this combined thermodynamic cycle system with different marine engine load and under practical comprehensive operating condition of marine engine.The results of the present study show that the combined thermodynamic cycle system with R123 as organic working fluid has the best performance.The system with cis-butene has the worst economic performance.Under practical comprehensive operating conditions of ships,R123 has the shortest Payback Periods,which are 8.51 years and 8.14 years for 8 S70 ME-C10.5 engine and 5G95 ME-C10.5 engine,respectively.Correspondingly,payback Periods of Cyclopentane are 11.95 years and 11.90 years.The above values are much shorter than 25 years which are the lifetime of a marine ship.Under practical comprehensive operating conditions of ships,the combined cycle system can provide output power which is at least equivalent to 25%of engine power.Considering that R123 will be phased out in near future,cyclopentane may be its good successor.Cyclopentane can be used safely by correct handling and installing according to manufacturer's instructions.