Objective To evaluate the disinfection of wastewater in China. Methods During the SARS epidemic occurred in Beijing, a study of different disinfection methods used in the main local wastewater plants including means o...Objective To evaluate the disinfection of wastewater in China. Methods During the SARS epidemic occurred in Beijing, a study of different disinfection methods used in the main local wastewater plants including means of chlorine, chlorine dioxide, ozone, and ultraviolet was carried out in our laboratory. The residual coliform, bacteria and trihalomethanes, haloacetic acids were determined after disinfection. Results Chlorine had fairly better efficiency on microorganism inactivation than chlorine dioxide with the same dosage. Formation of THMs and HAAs does not exceed the drinking water standard. UV irradiation had good efficiency on microorganism inactivation and good future of application in China. Organic material and ammonia nitrogen was found to be significant on inactivation and DBPs formation. Conclusion Chlorine disinfection seems to be the best available technology for coliform and bacteria inactivation. And it is of fairly low toxicological hazard due to the transformation of monochloramine.展开更多
The reclamation and disinfection of waters impacted by human activities(e.g., wastewater effluent discharges) are of growing interest for various applications but has been associated with the formation of toxic nitr...The reclamation and disinfection of waters impacted by human activities(e.g., wastewater effluent discharges) are of growing interest for various applications but has been associated with the formation of toxic nitrogenous disinfection byproducts(N-DBPs). Monochloramine used as an alternative disinfectant to chlorine can be an additional source of nitrogen in the formation of N-DBPs. Individual toxicity assays have been performed on many DBPs, but few studies have been conducted with complex mixtures such as wastewater effluents. In this work, we compared the cytotoxicity and genotoxicity of wastewater effluent organic matter(Ef OM) before and after chloramination. The toxicity of chloraminated Ef OM was significantly higher than the toxicity of raw Ef OM, and the more hydrophobic fraction(HPO)isolated on XAD-8 resin was more toxic than the fraction isolated on XAD-4 resin.More DBPs were also isolated on the XAD-8 resin. N-DBPs(i.e., haloacetonitriles or haloacetamides) were responsible for the majority of the cytotoxicity estimated from DBP concentrations measured in the XAD-8 and XAD-4 fractions(99.4% and 78.5%, respectively).Measured DBPs accounted for minor proportions of total brominated and chlorinated products, which means that many unknown halogenated compounds were formed and can be responsible for a significant part of the toxicity. Other non-halogenated byproducts(e.g.,nitrosamines) may contribute to the toxicity of chloraminated effluents as well.展开更多
Recycling wastewater is becoming more common as communities around the world try to better control their water resources against an increased frequency of either prolonged droughts or intense flooding. For communities...Recycling wastewater is becoming more common as communities around the world try to better control their water resources against an increased frequency of either prolonged droughts or intense flooding. For communities in coastal areas, wastewaters may contain elevated levels of bromide(Br^-) and iodide(I^-) from seawater intrusion or high mineral content of source waters. Disinfection of such wastewater is mandatory to prevent the spread of pathogens, however little is known about the toxicity of wastewater after disinfection in the presence of Br^-and I^-. In this study we compared the induction of chronic cytotoxicity in mammalian cells in samples of municipal secondary wastewater effluent amended with elevated levels of Br^-/I^-after disinfection by chlorine, chloramines or ozone to identify which disinfection process generated wastewater with the lowest level of adverse biological response. Chlorination increased mammalian cell cytotoxicity by 5times as compared to non-disinfected controls. Chloramination produced disinfected wastewater that expressed 6.3 times more cytotoxicity than the non-disinfected controls and was 1.3 times more cytotoxic than the chlorinated samples. Ozonation produced wastewater with cytotoxicity comparable to the non-disinfected controls and was at least 4times less cytotoxic than the chlorine disinfected wastewaters. These results indicate that compared to chlorination and chloramination, ozonation of wastewater with high Br^-/Ilevels yielded the lowest mammalian cell cytotoxicity, suggesting its potential as a more favorable method to disinfect wastewater with minimizing the biological toxicity in mind.展开更多
文摘Objective To evaluate the disinfection of wastewater in China. Methods During the SARS epidemic occurred in Beijing, a study of different disinfection methods used in the main local wastewater plants including means of chlorine, chlorine dioxide, ozone, and ultraviolet was carried out in our laboratory. The residual coliform, bacteria and trihalomethanes, haloacetic acids were determined after disinfection. Results Chlorine had fairly better efficiency on microorganism inactivation than chlorine dioxide with the same dosage. Formation of THMs and HAAs does not exceed the drinking water standard. UV irradiation had good efficiency on microorganism inactivation and good future of application in China. Organic material and ammonia nitrogen was found to be significant on inactivation and DBPs formation. Conclusion Chlorine disinfection seems to be the best available technology for coliform and bacteria inactivation. And it is of fairly low toxicological hazard due to the transformation of monochloramine.
基金supported by the King Abdullah University of Science and Technology (KAUST) Office of Competitive Research Funds, entitled "Nitrogenous Disinfection By-Products in Reclaimed Wastewater Effluents: Chemistry, Toxicity and Control Strategies"
文摘The reclamation and disinfection of waters impacted by human activities(e.g., wastewater effluent discharges) are of growing interest for various applications but has been associated with the formation of toxic nitrogenous disinfection byproducts(N-DBPs). Monochloramine used as an alternative disinfectant to chlorine can be an additional source of nitrogen in the formation of N-DBPs. Individual toxicity assays have been performed on many DBPs, but few studies have been conducted with complex mixtures such as wastewater effluents. In this work, we compared the cytotoxicity and genotoxicity of wastewater effluent organic matter(Ef OM) before and after chloramination. The toxicity of chloraminated Ef OM was significantly higher than the toxicity of raw Ef OM, and the more hydrophobic fraction(HPO)isolated on XAD-8 resin was more toxic than the fraction isolated on XAD-4 resin.More DBPs were also isolated on the XAD-8 resin. N-DBPs(i.e., haloacetonitriles or haloacetamides) were responsible for the majority of the cytotoxicity estimated from DBP concentrations measured in the XAD-8 and XAD-4 fractions(99.4% and 78.5%, respectively).Measured DBPs accounted for minor proportions of total brominated and chlorinated products, which means that many unknown halogenated compounds were formed and can be responsible for a significant part of the toxicity. Other non-halogenated byproducts(e.g.,nitrosamines) may contribute to the toxicity of chloraminated effluents as well.
基金partially supported by grant RD83582201-0 from the U.S.Environmental Protection Agency (EPA)a USDA grant 2017-68007-26307
文摘Recycling wastewater is becoming more common as communities around the world try to better control their water resources against an increased frequency of either prolonged droughts or intense flooding. For communities in coastal areas, wastewaters may contain elevated levels of bromide(Br^-) and iodide(I^-) from seawater intrusion or high mineral content of source waters. Disinfection of such wastewater is mandatory to prevent the spread of pathogens, however little is known about the toxicity of wastewater after disinfection in the presence of Br^-and I^-. In this study we compared the induction of chronic cytotoxicity in mammalian cells in samples of municipal secondary wastewater effluent amended with elevated levels of Br^-/I^-after disinfection by chlorine, chloramines or ozone to identify which disinfection process generated wastewater with the lowest level of adverse biological response. Chlorination increased mammalian cell cytotoxicity by 5times as compared to non-disinfected controls. Chloramination produced disinfected wastewater that expressed 6.3 times more cytotoxicity than the non-disinfected controls and was 1.3 times more cytotoxic than the chlorinated samples. Ozonation produced wastewater with cytotoxicity comparable to the non-disinfected controls and was at least 4times less cytotoxic than the chlorine disinfected wastewaters. These results indicate that compared to chlorination and chloramination, ozonation of wastewater with high Br^-/Ilevels yielded the lowest mammalian cell cytotoxicity, suggesting its potential as a more favorable method to disinfect wastewater with minimizing the biological toxicity in mind.