Performance of a Horizontal Flow Constructed Reed Bed Filter for Municipal Wastewater Treatment: The Case Study of the Prototype Installed at Gaston Berger University, Saint-Louis, Senegal
1
作者 Abdou Khafor Ndiaye Falilou Coundoul +2 位作者 Abdoulaye Deme Antonina Torrens Armengol Abdoulaye Senghor 《Natural Resources》 2024年第1期1-16,共16页
In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed... In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability. 展开更多
关键词 Constructed Wetlands Horizontal Flow Reed Beds wastewater treatment Phragmites and Typha Plants Physicochemical Pollutant Removal Microbiological Indicators Fecal Coliforms and Helminth Eggs Water Quality Improvement Senegal Water Reuse Standards Sustainable Water Management Agricultural Irrigation Reuse Nutrient Removal Efficiency Environmental Engineering Ecological Sanitation Systems
下载PDF
Performance Evaluation of Two Series Vertical Flow Filters for Wastewater Treatment: A Case Study of the Prototype Installed at Gaston Berger University, Saint-Louis, Senegal
2
作者 Abdou Khafor Ndiaye Falilou Coundoul +2 位作者 Abdoulaye Deme Antonina Torrens Armengol Abdoulaye Senghor 《Open Journal of Modern Hydrology》 CAS 2024年第1期14-32,共19页
This paper evaluates the efficacy of two sequential vertical flow filters (VFF), FV1 and FV2, implanted with Typha, in a pilot-scale wastewater treatment system. FV1 comprises three cells (FV1a, FV1b, and FV1c), while... This paper evaluates the efficacy of two sequential vertical flow filters (VFF), FV1 and FV2, implanted with Typha, in a pilot-scale wastewater treatment system. FV1 comprises three cells (FV1a, FV1b, and FV1c), while FV2 consists of two cells (FV2a and FV2b), each designed to reduce various physicochemical and microbiological pollutants from wastewater. Quantitative analyses show significant reductions in electrical conductivity (from 1331 to 1061 μS/cm), biochemical oxygen demand (BOD5 from 655.6 to 2.3 mg/L), chemical oxygen demand (COD from 1240 to 82.2 mg/L), total nitrogen (from 188 to 37.3 mg/L), and phosphates (from 70.9 to 14.6 mg/L). Notably, FV2 outperforms FV1, particularly in decreasing dissolved salts and BOD5 to remarkably low levels. Microbiological assessments reveal a substantial reduction in fecal coliforms, from an initial concentration of 7.5 log CFU/100mL to 3.7 log CFU/100mL, and a complete elimination of helminth eggs, achieving a 100% reduction rate in FV2. The study highlights the impact of design parameters, such as filter material, media depth, and plant species selection, on treatment outcomes. The findings suggest that the judicious choice of these components is critical for optimizing pollutant removal. For instance, different filtration materials show varying efficacies, with silex plus river gravel in FV1c achieving superior pollutant reduction rates. In conclusion, VFFs emerge as a promising solution for wastewater treatment, underscoring the importance of design optimization to enhance system efficiency. Continuous monitoring and adaptation of treatment practices are imperative to ensure water quality, allowing for safe environmental discharge or water reuse. The research advocates for ongoing improvements in wastewater treatment technologies, considering the environmental challenges of the current era. The study concludes with a call for further research to maximize the effectiveness of VFFs in water management. 展开更多
关键词 PHYTOREMEDIATION Phytopurification Plant-Based Purifier wastewater Treat-ment Vertical Flow Filters Pollutant Reduction TYPHA Physicochemical Analysis Microbial Removal
下载PDF
Ecological Wastewater Treatment System in a School Environment Using a Horizontal Flow Biological Reactor: The Case of Typha
3
作者 Falilou Coundoul Abdou Khafor Ndiaye Abdoulaye Deme 《Journal of Environmental Protection》 2024年第1期1-12,共12页
The overarching goal of this study is to offer an effective and sustainable solution to the challenges of sanitation in rural and school settings in the northern region of Senegal. The study explores a wastewater trea... The overarching goal of this study is to offer an effective and sustainable solution to the challenges of sanitation in rural and school settings in the northern region of Senegal. The study explores a wastewater treatment approach based on phytoremediation, with a particular focus on the use of horizontally-flowing reed bed filters. Furthermore, it aims to adapt and optimize these systems for the specific needs of Senegal, focusing on wastewater in school environments. Thus, we constructed a horizontally-flowing reed bed filter, planted with Typha, at the Ndiébène Gandiol school in Senegal. We will investigate the efficiency of wastewater treatment by this horizontally-flowing reed bed filter, emphasizing the role of the plant used: Typha. The filter is described in detail, specifying its dimensions, its composition of flint gravel, and the choice of plants, namely Typha. The experimental protocol is detailed, describing the sampling at the entrance and exit of the filter to evaluate water quality. The parameters analyzed include Chemical Oxygen Demand (COD), Biochemical Oxygen Demand over 5 days (BOD5), suspended solids, ammonium, nitrates, phosphates, pH, conductivity, and fecal coliforms. The results indicate a significant improvement in water quality after treatment. COD, BOD5, suspended solids, and fecal coliforms are greatly reduced, thus demonstrating the efficacy of the Typha filter. However, nitrate concentrations remain relatively stable, suggesting room for improvement in their elimination. A perspective of reuse of the treated water is considered, showing that the effluents from the planted filter meet Senegalese and international standards for irrigation. The findings suggest that these waters could be used for a variety of crops, thereby reducing the pressure on freshwater resources. In conclusion, the Typha-based filtration system shows promising results for improving water quality in this region of Senegal. However, adjustments are necessary for more effective nitrate removal. This study paves the way for sustainable use of treated wastewater for irrigation, thus contributing to food security and the preservation of water resources. 展开更多
关键词 Hydraulic Engineering wastewater Quality wastewater treatment Agricultural Irrigation SANITATION Engineering ENVIRONMENT
下载PDF
Ecological Wastewater Treatment System Using a Horizontal Flow Biological Reactor: The Case of Vetiver
4
作者 Falilou Coundoul Abdou Khafor Ndiaye Abdoulaye Deme 《Journal of Environmental Protection》 2024年第1期26-38,共13页
Confronted with the challenge of wastewater management, particularly in the school environment of Senegal, our study set out to achieve multiple objectives. Following field surveys, laboratory analyses of wastewater s... Confronted with the challenge of wastewater management, particularly in the school environment of Senegal, our study set out to achieve multiple objectives. Following field surveys, laboratory analyses of wastewater samples were carried out, revealing a significant pollutant load. In the community of Gandiol, near Saint-Louis (Senegal), the school of Ndiebene Gandiol 1 faces significant sanitation challenges. Our study aimed to address this issue by using a constructed filter composed of two filtering bed cells measuring 12 × 8.5 m, preceded by a septic tank. We particularly focused on the influence of Vetiver;a plant chosen for its purification potential. Our analyses showed remarkable efficiency of the filter. Elimination rates reached 95% for 5-Day Biochemical Oxygen Demand (BOD5), 91% for Chemical Oxygen Demand (COD), and 92% for SS, far exceeding the Senegalese standards set at 50 mg/L, 200 mg/L, and 40 mg/L, respectively. Furthermore, the concentration of fecal coliforms was reduced to 176 FCU/100mL, well below the Senegalese threshold of 2000 FCU/100mL and close to the World Health Organization’s (WHO) recommendation of 1000 FCU/100mL. However, despite these promising results, some parameters, particularly the concentration of certain pollutants, approached the thresholds defined by European legislation. For example, for Suspended Solids (SS), the post-treatment level of 3 mg/L was well below the Senegalese standard but edged close to the European minimum of 10 mg/L. In conclusion, the Vetiver filter demonstrated a remarkable ability to treat school wastewater, offering high pollutant elimination percentages. These results suggest significant opportunities for the reuse of treated water, potentially in areas such as irrigation, though some adjustments may be necessary to meet the strictest standards such as those of the European union (EU). 展开更多
关键词 Hydraulic Engineering wastewater Quality wastewater treatment Agricultural Irrigation SANITATION ENGINEERING ENVIRONMENT
下载PDF
Design and Sizing of an Ecological Wastewater Treatment System in a School Environment: A Case Study of Ndiebene Gandiol 1 School
5
作者 Falilou Coundoul Abdou Khafor Ndiaye +1 位作者 Abdoulaye Deme David de la Varga 《Journal of Water Resource and Protection》 CAS 2024年第1期41-57,共17页
The primary objective of this study was to design and size a sustainable sanitation solution for the Ndiebene Gandiol 1 school located in the eponymous commune in northern Senegal. Field investigations led to the coll... The primary objective of this study was to design and size a sustainable sanitation solution for the Ndiebene Gandiol 1 school located in the eponymous commune in northern Senegal. Field investigations led to the collection of wastewater samples. Their analysis revealed specific pollutant loads, including loads of BOD5 3.6966 kgO<sub>2</sub>/day and COD of 12.8775 kgO<sub>2</sub>/day, which were central to the design phase. Following a rigorous assessment of the existing sanitation infrastructure, constructed wetland (CWs) emerged as the most appropriate ecological solution. This system, valued for its ability to effectively remove contaminants, was tailored to the specific needs of the site. Consequently, the final design of the filter extends over 217.16 m<sup>2</sup>, divided into two cells of 108.58 m<sup>2</sup> each, with dimensions of 12.77 m in length and 8.5 m in width. The depth of the filtering medium is approximately 0.60 m, meeting the standards while ensuring maximized purification. Typha, an indigenous and prolific plant known for its purification abilities, was selected as the filtering agent. Concurrently, non-crushed gravel was chosen for its proven filtration capacity. This study is the result of a combination of scientific rigor and design expertise. It provides a holistic view of sanitation for Ndiebene Gandiol. The technical specifications and dimensions of the constructed wetland filter embody an approach that marries indepth analysis and practical application, all aimed at delivering an effective and long-lasting solution to the local sanitation challenges. By integrating precise scientific data with sanitation design expertise, this study delivers a holistic solution for Ndiebene Gandiol. The detailed dimensions and specifications of the constructed wetland filter reflect a methodology that combines meticulous analysis with practical adaptation, aiming to provide an effective and sustainable response to the challenges of rural and school sanitation in the northern region of Senegal. 展开更多
关键词 Water Review Hydraulic Engineering Water treatment Agricultural Irrigation SANITATION Engineering Environment
下载PDF
A Comparative Analysis of Vetiver and Typha in Ecological Wastewater Treatment Using a Horizontal Flow Constructed Wetlands in Rural Setting
6
作者 Falilou Coundoul Abdou Khafor Ndiaye +1 位作者 Abdoulaye Deme Antonina Torrens Armegnol 《Journal of Agricultural Chemistry and Environment》 2024年第1期67-82,共16页
This study presents an assessment of wastewater ecological treatment processes utilizing a horizontal flow bio-reactor at the Ndiebene Gandiol 1 school. It primarily aims to juxtapose the filtration efficacy of two di... This study presents an assessment of wastewater ecological treatment processes utilizing a horizontal flow bio-reactor at the Ndiebene Gandiol 1 school. It primarily aims to juxtapose the filtration efficacy of two distinct vegetative cells, Vetiver and Typha, in the pursuit of sustainable wastewater management strategies for rural scholastic institutions. A synergistic approach was employed, integrating on-site surveys for site-specific insights and laboratory analyses to quantify the pollutant loads pre- and post-treatment. Our findings indicate that both Vetiver and Typha-infused filter beds significantly reduce most contaminants, with particular success in diminishing chemical oxygen demand (COD) and biological oxygen demand (BOD5). Vetiver was notable for its superior reduction of COD, achieving an average effluent concentration of 74 mg/L, in contrast to Typha’s 155 mg/L. Conversely, Typha excelled in suspended solids removal, registering 1 mg/L against Vetiver’s 3 mg/L. While both systems notably surpassed the target metrics across several indicators, including fecal coliform reduction, our results pinpoint the need for refinement in phosphate remediation. Conclusively, the study underscores the efficacy of both Vetiver and Typha systems in rural wastewater treatment contexts, with their integrative application potentially paving the way for enhanced system robustness and efficiency. The outcomes herein highlight the imperative for continued research to further hone these ecological treatment modalities, especially concerning phosphate elimination. 展开更多
关键词 Hydraulics Water treatment Agricultural Irrigation SANITATION Engineering Environment
下载PDF
Design and Operation of the Printing and Dyeing Wastewater Treatment Project by Combination of Coagulation Sedimentation - Hydrolytic Acidification with Aeration Tank - Biological Aerated Filter - Active Sand Filter 被引量:2
7
作者 Dong Qianqian He Qianmei +2 位作者 Yang Jingyuan Peng Yadong Bian Lipo 《Meteorological and Environmental Research》 CAS 2017年第4期84-88,92,共6页
In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics ... In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics and SS,and lots of pollutants difficult to degrade by microorganism. The process and operating parameters of project are optimized and debugged,and its economic and environmental benefits are analyzed.The results show that the process of coagulation sedimentation-hydrolytic acidification with aeration tank-biological aerated filter-active sand filter is applied in Gaoyang Sewage Treatment Plant. The design scale of sewage treatment plant is 120000 m^3/d. The influent is as following: COD is 669mg/L; SS is 424mg/L; NH_3-N is 8.83mg/L; TP is 6.03mg/L. After the process,the best removal rates of COD,SS,NH_3-N and TP are 93. 5%,98. 8%,97. 1% and 96. 2%,respectively. The various indexes of effluent water complied with standard A of the first order in Pollutants Emission Standard of Urban Wastewater Treatment Plant( GB 18918-2002). The processing cost is only 0. 807 yuan/m^3. As a result,the project construction and operation not only improve the environment,but also promote regional economic development. Process design and operating parameters provide an important reference value for the printing and dyeing wastewater treatment industry. 展开更多
关键词 Water pollution control engineering Printing and DYEING wastewater Biological aerated FILTER ACTIVE SAND FILTER Industrial design
下载PDF
Significance of Primary Treatment Selection in the Efficiency of Wastewater Treatment in Constructed Wetlands (CWs)
8
作者 Snezana Didanovic Danijel Vrhovsek 《Journal of Water Resource and Protection》 CAS 2024年第5期309-327,共19页
This research explores strategies to enhance the efficiency of secondary treatment in Vertical Flow Constructed Wetlands (CW) in Montenegro. The focus is on selecting appropriate primary treatment methods alongside th... This research explores strategies to enhance the efficiency of secondary treatment in Vertical Flow Constructed Wetlands (CW) in Montenegro. The focus is on selecting appropriate primary treatment methods alongside three distinct substrate types to improve wastewater treatment efficacy. The study examines the combination of two primary treatments with different substrate types in constructed wetlands (CW1, CW2, and CW3). The primary treatments include the existing wastewater treatment plant (WWTP) in Podgorica, involving coarse material removal through screens, inert material separation in aerated sand traps, and sediment and suspended matter removal in primary sedimentation tanks. The Extreme Separator (ExSep) was employed to evaluate its efficacy as a primary treatment method. The research demonstrates that the efficiency of CW can be significantly enhanced by selecting suitable primary treatment methods and substrates in Podgorica’s conditions. The most promising results were achieved by combining ExSep as a primary treatment with secondary treatment in CW-3. The removal efficiencies after CW3 for COD, BOD, and TSS exceeded 89%, 93%, and 91%, respectively. The outcomes underscore the significance of primary treatment in mitigating pollutant loads before discharge into the constructed wetlands, emphasizing potential areas for further optimization in wastewater treatment practices to enhance environmental sustainability and water quality management. 展开更多
关键词 Constructed Wetlands (CW) Substrates for Wetlands Vertical Flow System Primary treatment treatment Efficacy
下载PDF
Progress and prospects of Mg-based amorphous alloys in azo dye wastewater treatment
9
作者 Yanan Chen Fengchun Chen +5 位作者 Liang Li Chen Su Bo Song Hongju Zhang Shengfeng Guo Fusheng Pan 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第3期873-889,共17页
Mg-based amorphous alloys exhibit efficient catalytic performance and excellent biocompatibility with a promising application probability,specifically in the field of azo dye wastewater degradation.However,the problem... Mg-based amorphous alloys exhibit efficient catalytic performance and excellent biocompatibility with a promising application probability,specifically in the field of azo dye wastewater degradation.However,the problems like difficulty in preparation and poor cycling stability need to be solved.At present,Mg-based amorphous alloys applied in wastewater degradation are available in powder and ribbon.The amorphous alloy powder fabricated by ball milling has a high specific surface area,and its reactivity is thousands of times better than that of gas atomized alloy powder.But the development is limited due to the high energy consumption,difficult and costly process of powder recycling.The single roller melt-spinning method is a new manufacturing process of amorphous alloy ribbon.Compared to amorphous powder,the specific surface area of amorphous ribbon is relatively lower,therefore,it is necessary to carry out surface modification to enhance it.Dealloying is a way that can form a pore structure on the surface of the amorphous alloys,increasing the specific surface area and providing more reactive sites,which all contribute to the catalytic performance.Exploring the optimal conditions for Mg-based amorphous alloys in wastewater degradation by adjusting amorphous alloy composition,choosing suitable method to preparation and surface modification,reducing cost,expanding the pH range will advance the steps to put Mg-based amorphous alloys in industrial environments into practice. 展开更多
关键词 Mg-based amorphous alloys Azo dyes DEALLOYING Surface modification wastewater degradation.
下载PDF
Ultrahydrophobic melamine sponge via interfacial modification with reduced graphene oxide/titanium dioxide nanocomposite and polydimethylsiloxane for oily wastewater treatment
10
作者 Hamidatu Alhassan Ying Woan Soon +1 位作者 Anwar Usman Voo Nyuk Yoong 《Water Science and Engineering》 EI CAS CSCD 2024年第2期139-149,共11页
Three-dimensional(3D)porous absorbents have attracted significant attention in the oily wastewater treatment technology due to their high porosity and elasticity.Given their amphiphilic surface,they have a propensity ... Three-dimensional(3D)porous absorbents have attracted significant attention in the oily wastewater treatment technology due to their high porosity and elasticity.Given their amphiphilic surface,they have a propensity to simultaneously absorb water and oil,which restricts their range of applications.In this study,a reduced graphene oxide and titanium dioxide nanocomposite(rGO/TiO_(2))was used to fabricate an ultra-hydrophobic melamine sponge(MS)through interfacial modification using a solution immersion technique.To further modify it,poly-dimethylsiloxane(PDMS)was grafted onto its surface to establish stronger covalent bonds with the composite.The water contact angle of the sponge(rGO/TiO_(2)/PDMS/MS)was 164.2°,which satisfies the condition for ultrahydrophobicity.The evidence of its water repellency was demonstrated by the Cassie-Baxter theory and the lotus leaf effect.As a result of the increased density of rGO/TiO_(2)/PDMS/MS,it recorded an initial capacity that was 2 g/g lower than the raw MS for crude oil absorption.The raw MS retained 53% of its initial absorption capacity after 20 cycles of absorption,while rGO/TiO_(2)/PDMS/MS retained 97%,suggesting good recyclability.Excellent oil and organic solvent recovery(90%-96%)was demonstrated by rGO/TiO_(2)/PDMS/MS in oil-water combinations.In a continuous separation system,it achieved a remarkable separation efficiency of 2.4×10^(6)L/(m^(3)·h),and in turbulent emulsion separation,it achieved a demulsification efficiency of 90%-91%.This study provides a practical substitute for massive oil spill cleaning. 展开更多
关键词 Oily wastewater Reduced graphene oxide Polydimethylsiloxane(PDMS) Emulsion separation Melamine sponge
下载PDF
Simulation of Low TDS and Biological Units of Fajr Industrial Wastewater Treatment Plant Using Artificial Neural Network and Principal Component Analysis Hybrid Method
11
作者 Naser Mehrdadi Hamed Hasanlou +2 位作者 Mohammad Taghi Jafarzadeh Hamidreza Hasanlou Hamid Abdolabadi 《Journal of Water Resource and Protection》 2012年第6期370-376,共7页
Being familiar with characteristics of industrial town effluents from various wastewater treatment units, which have high qualitative and quantitative variations and more uncertainties compared to urban wastewaters, p... Being familiar with characteristics of industrial town effluents from various wastewater treatment units, which have high qualitative and quantitative variations and more uncertainties compared to urban wastewaters, plays very effective role in governing them. With regard to environmental issues, proper operation of wastewater treatment plants is of par- ticular importance that in the case of inappropriate utilization, they will cause serious problems. Processes that exist in environmental systems mostly have two major characteristics: they are dependent on many variables;and there are complex relationships between its components which make them very difficult to analyze. In order to achieve a better and efficient control over the operation of an industrial wastewater treatment plant (WWTP), powerful mathematical tool can be used that is based on recorded data from some basic parameters of wastewater during a period of treatment plant operation. In this study, the treatment plant was divided into two main subsystems including: Low TDS (Total Dissolved Solids) treatment unit and Biological unit (extended aeration). The multilayer perceptron feed forward neural network with a hidden layer and stop training method was used to predict quality parameters of the industrial effluent. Data of this study are related to the Fajr Industrial Wastewater Treatment Plant, located in Mahshahr—Iran that qualita- tive and quantitative characteristics of its units were used for training, calibration and validation of the neural model. Also, Principal Component Analysis (PCA) technique was applied to improve performance of generated models of neural networks. The results of L-TDS unit showed good accuracy of the models in estimating qualitative profile of wastewater but results of biological unit did not have sufficient accuracy to being used. This model facilitates evaluating the performance of each treatment plant units through comparing the results of prediction model with the standard amount of outputs. 展开更多
关键词 Fajr Industrial wastewater treatment Plant SIMULATION Artificial Neural Network PCA LOW TDS BIOLOGICAL Unit
下载PDF
Performance Simulation of H-TDS Unit of Fajr Industrial Wastewater Treatment Plant Using a Combination of Neural Network and Principal Component Analysis
12
作者 Hamed Hasanlou Naser Mehrdadi +1 位作者 Mohammad Taghi Jafarzadeh Hamidreza Hasanlou 《Journal of Water Resource and Protection》 2012年第5期311-317,共7页
Nowadays, with regard to environmental issues, proper operation of wastewater treatment plants is of particular importance that in the case of inappropriate utilization, they will cause serious problems. Processes tha... Nowadays, with regard to environmental issues, proper operation of wastewater treatment plants is of particular importance that in the case of inappropriate utilization, they will cause serious problems. Processes that exist in environmental systems and environmental engineers are dealing with them mostly have two major characteristics: they are dependent on many variables;and there are complex relationships between its components which make them very difficult to analyze. Being familiar with characteristics of industrial town effluents from various wastewater treatment units, which have high qualitative and quantitative variations and more uncertainties compared to urban wastewaters, plays very effective role in governing them. In order to achieve a better and efficient control over the operation of an industrial wastewater treatment plant, powerful mathematical tool can be used that is based on recorded data from some basic parameters of wastewater during a period of treatment plant operation. In this study, the multilayer perceptron (MLP) feed forward neural network with a hidden layer and stop training method was used to predict quality parameters of the industrial effluent. Data of this study are related to the Fajr Industrial Wastewater Treatment Plant located in Mahshahr—Iran that qualitative and quantitative characteristics of its units were used for training, calibration and evaluation of the neural model. Also, Principal Component Analysis technique was applied to modify and improve performance of generated models of neural networks. The results of this model showed good accuracy of the model in estimating qualitative pro- file of wastewater. This model facilitates evaluating the performance of each treatment plant units through comparing the results of prediction model with the standard amount of output. 展开更多
关键词 Simulation Artificial NEURAL Network PCA Fajr Industrial WASTE Water treatment PLANT High TDS UNIT
下载PDF
Improvement of Water and Wastewater Treatment Process Using Various Sound Waves—A Consideration from the Viewpoint of Frequency 被引量:1
13
作者 Akira Hiratsuka Yugo Tomonaga +1 位作者 Yoshiro Yasuda Ryoji Tsujino 《Journal of Water Resource and Protection》 2014年第15期1464-1474,共11页
Application of sound waves is one of the novel techniques for the improvement of water treatment process. In this study, various sound waves such as 1) ultrasonic wave, 2) music box, and 3) windbell were irradiated to... Application of sound waves is one of the novel techniques for the improvement of water treatment process. In this study, various sound waves such as 1) ultrasonic wave, 2) music box, and 3) windbell were irradiated to water and wastewater for removing contaminants such as nitrate, phosphorus and BOD/COD. As a result, a possibility of improvement of water and wastewater treatment process using sound waves with various frequencies was proposed. 展开更多
关键词 Sound WAVES (Frequency) Total HARDNESS (Ca2%PLUS% Mg2%PLUS%) Nitrogen (N) Phosphorus (P) WATER treatment
下载PDF
Importance of Monitor and Control on New-Emerging Pollutants in Conventional Wastewater Treatment Plants
14
作者 Jingyang Luo Qin Zhang +2 位作者 Jiashun Cao Fang Fang Qian Feng 《Journal of Geoscience and Environment Protection》 2018年第1期55-58,共4页
The wide occurrence of new-emerging pollutants and their potential environmental and ecological risks have recently caused great public concerns. The paper firstly put forward the severe problem. Then the possible mai... The wide occurrence of new-emerging pollutants and their potential environmental and ecological risks have recently caused great public concerns. The paper firstly put forward the severe problem. Then the possible main reasons were analyzed which might attribute to both the inefficient removal of wastewater treatment plants with conventional technology and ignorance of the monitor and control of new-emerging pollutants in the effluents. Also, the complexity and extreme high costs may also make the organizations sidestep the problem. Finally, possible strategies to deal with the problems were proposed. The upgrade of wastewater treatment plants was important and urgent. 展开更多
关键词 New-Emerging POLLUTANTS Environmental and Ecological RISKS Inefficient Removal wastewater treatment Plants UPGRADE
下载PDF
Preparation and Application of Polymer Silicate Phosphate Ferric Sulfate Used in High-Viscosity Oil Refining Wastewater Treatment 被引量:1
15
作者 Xi CHEN Xinyang XU Yindi FAN 《Journal of Water Resource and Protection》 2009年第3期195-202,共8页
A new kind of flocculants, named Polymer Silicate Phosphate Ferric Sulfate(PSPFS), was synthesized by ferrous sulfate used as the main material and activated silicic acid as additive. In this paper, High-Viscosity Oil... A new kind of flocculants, named Polymer Silicate Phosphate Ferric Sulfate(PSPFS), was synthesized by ferrous sulfate used as the main material and activated silicic acid as additive. In this paper, High-Viscosity Oil Refining wastewater from Liaohe Petrochemical Corporation was the treatment object. Overall, the in-fluencing factors and synthesis technology conditions of PSPFS were determined by experiments. First of all, the conditions of influencing factors were showed as follows: the mass percent concentration of ferrous sulfate 55%,concentration of sodium silicate 15% , the molar ratio of ferrous sulfate and hydrogen peroxide 1.2:1, oxidation temperature 40 degree Celsius, oxidation time 4 hours, polymerization temperature 60 de-gree Celsius and polymerization time 2 hours. Secondly, the optimal ratios of components were determined by uniform design method. The molar ratio of Fe/Si is 5.0:1, Fe/H2SO4 is 3.2:1, and Fe/P is 18.0:1. At last, the optimal experimental condition was determined as follows: the dosing quantity 200mg/L, pH value 5.5~9, temperature 25~45℃, stirring time 2 min, and standing time 3 min, according to the result of floc-culation experiments with PSPFS. Besides, the result of the comparative experiments showed that the effi-ciency of PSPFS was much better than the reference flocculants. 展开更多
关键词 POLYMER SILICATE PHOSPHATE Ferric Sulfate FLOCCULANT PREPARATION High-Viscosity Oil Refining wastewater
下载PDF
Mass-producible low-cost flexible electronic fabrics for azo dye wastewater treatment by electrocoagulation
16
作者 Chaoyi Yin Jingyuan Ma +2 位作者 Jian Qiu Ruifang Liu Long Ba 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第7期222-230,共9页
Electrocoagulation is progressively becoming an ecologically friendly water treatment method owing to its lack of secondary pollution,high active ingredient concentration,high treatment effectiveness,simple equipment,... Electrocoagulation is progressively becoming an ecologically friendly water treatment method owing to its lack of secondary pollution,high active ingredient concentration,high treatment effectiveness,simple equipment,and simplicity of automated control implementation.Herein,electrocoagulation is offered as a method for treating wastewater containing azo dyes using a revolutionary flexible electronic fabric that can be mass-producible at a reasonable price.A computer-controlled machine embroiders 316L stainless steel fiber(316L SSF)onto an insulating fabric to manufacture a flexible electronic device of cathode and anode with a monopolar arrangement on the fabric surface.Using methyl orange(MO)solution to simulate azo dye wastewater,the decolorization rate of 500 ml MO reached 99.25% under the conditions of 50 mg·L^(-1)initial mass concentration,120 min electrolysis time,15 mA·g^(-1)current density,1 cm electrode spacing,0.1 mol·L^(-1)NaCl,pH 7.6,200 r·min^(-1)rotational speed of the stirrer,and 22-25℃ room temperature.In addition,it is feasible to embroider flexible electronic fabrics with varied sizes and numbers of electrodes based on the amount of treated sewage to increase the degradation rate,which has significant practical application value. 展开更多
关键词 Flexible electronic fabric 316L Stainless steel fiber EMBROIDERY ELECTROCOAGULATION wastewater treatment
下载PDF
Greenhouse gas reduction of co-benefit-type wastewater treatment system for fish-processing industry: A real-scale case study in Indonesia
17
作者 Yoshiteru Hamatani Takahiro Watari +3 位作者 Masashi Hatamoto Takashi Yamaguchi Tjandra Setiadi Toshihiko Konda 《Water Science and Engineering》 EI CAS CSCD 2023年第3期271-279,共9页
This study examined the application of co-benefit-type wastewater treatment technology in the fish-processing industry. Given that there was a dearth of information on fish-processing industrial wastewater in Indonesi... This study examined the application of co-benefit-type wastewater treatment technology in the fish-processing industry. Given that there was a dearth of information on fish-processing industrial wastewater in Indonesia, site surveys were conducted. For the entire fish-processing industry throughout the country, the dissemination rate of wastewater treatment facilities was less than 50%. Using a co-benefit approach, a real-scale swim-bed technology (SBT) and a system combining an anaerobic baffled reactor (ABR) with SBT (ABR–SBT) were installed in a fishmeal processing factory in Bali, Indonesia, and the wastewater system process performance was evaluated. In a business-as-usual scenario, the estimated chemical oxygen demand load and greenhouse gas (GHG) emissions from wastewater from the Indonesian fish-processing industry were 33 000 tons per year and 220 000 tons of equivalent CO_(2) per year, respectively. On the other hand, the GHG emissions in the co-benefit scenarios of the SBT system and ABR–SBT system were 98 149 and 26 720 tons per year, respectively. Therefore, introducing co-benefit-type wastewater treatment to Indonesia’s fish-processing industry would significantly reduce pollution loads and GHG emissions. 展开更多
关键词 Indonesian fish-processing industry Co-benefit wastewater treatment Greenhouse gas emission mitigation Anaerobic baffled reactor Swim-bed technology
下载PDF
Research Progress on Energy Plants in Piggery Wastewater Treatment
18
作者 Ziqiang AO Guiqun PENG +3 位作者 Cheng JIANG Bing YAN Jihai XIONG Jiaqi FU 《Agricultural Biotechnology》 CAS 2019年第1期215-218,223,共5页
Large-scale pig-raising can discharge a great deal of wastewater,which contains high content of organic matter,ammonia nitrogen and suspended solids.The improper treatment of the piggery wastewater can lead to serious... Large-scale pig-raising can discharge a great deal of wastewater,which contains high content of organic matter,ammonia nitrogen and suspended solids.The improper treatment of the piggery wastewater can lead to serious environmental problems. As a liquid fertilizer,piggery wastewater is relatively low in fertilizer efficiency and high in transportation cost,so it is very necessary to treat it in situ. Energy plants have the advantages of rapid growth,large biomass,strong tillering ability and developed root system. Therefore,energy plants can be used to absorb and transform the pollutants( like nitrogen and phosphorus) in piggery wastewater into the components of plants,as well as form the rhizosphere environment which is conducive to microbial growth,so as to enhance the effects of nitrogen and phosphorus removal. The obtained energy plants can be recycled as the raw materials for biogas to increase the production of biogas,which brings economic benefits while solving the environmental problems caused by piggery wastewater. 展开更多
关键词 Energy plants LARGE-SCALE PIG-RAISING RECYCLING wastewater treatment Nitrogen and PHOSPHORUS removal
下载PDF
Design and Comparison of Wastewater Treatment Plant Types (Activated Sludge and Membrane Bioreactor), Using GPS-X Simulation Program: Case Study of Tikrit WWTP (Middle Iraq)
19
作者 Alaa Uldeen Athil Arif Mohamed Tarek Sorour Samia Ahmed Aly 《Journal of Environmental Protection》 2018年第6期636-651,共16页
Mathematical models and simulation are considered a powerful tool in engineering practice. Those tools are becoming increasingly used for the improvement of wastewater treatment plants design because the conceptual de... Mathematical models and simulation are considered a powerful tool in engineering practice. Those tools are becoming increasingly used for the improvement of wastewater treatment plants design because the conceptual design is complex and ill-defined. In this paper, three alternatives: 1) complete mix activated sludge without nitrogen removal (CAS);2) complete mix activated sludge with nitrogen removal (CAS-N) and;3) membrane bioreactor (MBR) processes were designed into two steps: first concept design to calculate the size of process units, then second implement modeling and simulation to improve the accuracy of the conceptual design. In brief, the treatment process design has been verified by using the activated sludge model No. 1 (ASM1) in GPS-X (v.7) simulation software. This application helps not only in sizing the treatment units but also in understanding the plant’s capacity. In the same time, it can assist in studying the future expansion works required for increased hydraulic and organic loadings. For this purpose, Tikrit WWTP was selected as a case study. The used model was validated by comparing the designed values of the plant and the modeling data. The verification of the obtained results from both hand calculations and the results of the program showed a good agreement. A significant difference in the volume of secondary treatment was obtained from design calculations, where the CAS without denitrification system was 9244 m3 (aerobic and secondary tanks), CAS with denitrification system was 11,324 m3 (anoxic, aerobic and secondary tanks) and for MBR system was 7468 m3 (anoxic, aerobic and immersed membrane tanks). From the obtained results point of view, it can be concluded that mathematical models can be considered as worthy tools to complement the established wastewater treatment plant design procedures. 展开更多
关键词 Activated Sludge Membrane Bioreactor wastewater treatment wastewater treatment Plant DESIGN Modeling and Simulation
下载PDF
Occurrences of Glucocorticoids in Aquatic Environment and Their Removal during Wastewater Treatment
20
作者 吴清晨 吴世闵 +5 位作者 张茵茵 ANDERE Clement Miruka 朱大海 张艾 刘亚男 薛罡 《Journal of Donghua University(English Edition)》 CAS 2023年第3期293-318,共26页
Glucocorticoids(GCs) are a group of endocrine-disrupting compounds(EDCs) frequently prescribed against various medical conditions.Recently,GCs have been shown to be effective in managing septic shock in patients infec... Glucocorticoids(GCs) are a group of endocrine-disrupting compounds(EDCs) frequently prescribed against various medical conditions.Recently,GCs have been shown to be effective in managing septic shock in patients infected with the 2019 novel coronavirus(COVID-19).Due to colossal consumption and potential risks to aquatic organisms,GCs have immensely attracted the focus of the scientific research community as a water pollutant.Therefore,the aim of this paper is to review the current knowledge on the occurrence of various GCs in the aquatic environment and their removal during wastewater treatment.A variety of GCs are ubiquitous in surface water,hospital wastewater,and sewage water worldwide.And the minimum concentration in volume is below 0.01 ng/L,and the maximum one is 10 000 ng/L,and enter the environment through hospital and urban wastewater discharging.Compared with natural GCs,higher risks to aquatic environments could be induced by synthetic GCs.The current activated sludge processes used in wastewater treatment plants(WWTPs) are not fully effective in eliminating GCs,some of which may further increase the risk of GC in the environment.In comparison with the aerobic process in WWTPs,the anaerobic and anoxic processes were found to be more efficient for GC degradation.Of the studied GCs,fluticasone propionate,clobetasol propionate,fluocinolone acetonide,and triamcinolone acetonide need more attention due to their low removal efficiencies and strong toxicity.Among the advanced treatment processes,reverse osmosis,ultraviolet irradiation,CaO_(2),and plasma could achieve significant GC activity removal while micro/ultra-filtration,chlorination,and ozonation were less efficient. 展开更多
关键词 glucocorticoid(GC) endocrine disrupting compound(EDC) wastewater treatment plant(WWTP) advanced wastewater treatment