Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement...Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU.展开更多
Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the...Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the heat load on the electrode system of the ion source and the heat loading components of the beamline. Due to the heat loss in the return water pipe, there are some measuring errors for the current WFC system. In this paper, the errors were measured experimentally and analyzed theoretically, which lay a basis for the exact calculation of beam power deposition distribution and neutralization efficiency.展开更多
Using ion beam biotechnology in combination with soil-less plant cultivation on artificial substratum (floating beds), the experiments were conducted with Ipomoea aquatica Forsk. Plants were attached to floating-beds ...Using ion beam biotechnology in combination with soil-less plant cultivation on artificial substratum (floating beds), the experiments were conducted with Ipomoea aquatica Forsk. Plants were attached to floating-beds which were placed on the surface of artificially nutrient-enriched tank water, in order to study the purification and remediation efficiency of ion beam-treated I. aquatica cultivars. The results show that N + ion beams with 25keV energy and dosages of 0, 2.6, 3.9, 5.2, 6.5, 7.8, 9.1×10 13N +(ions)/cm 2 affected I. aquatica dry seeds differently, with the dose of 3.9×10 13N + (ions)/cm 2 improving effectively the performance as expressed by various biological indices. After ion beam application, I. aquatica cultivars grew well in nutrient-enriched water bodies, increasing the growth of leaves and stem, number of leaves, length and area of roots, plant height, and weight more remarkably than observed in the control. The net removing rates of TN, TP were as high as 75% and 82%, respectively. Especially under the dose of 3.9×10 13N +(ions)/cm 2, the net removing rates of TN, TP were highest, for 77% and 85%, respectively. It was proved that ion beam application improves phytoremediation and may be used to purify nutrient rich water bodies.展开更多
文摘Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU.
基金supported by the National Magnetic Confinement Fusion Science Program of China(No.2013GB101001)the International Science&Technology Cooperation Program of China(No.2014DFG61950)
文摘Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the heat load on the electrode system of the ion source and the heat loading components of the beamline. Due to the heat loss in the return water pipe, there are some measuring errors for the current WFC system. In this paper, the errors were measured experimentally and analyzed theoretically, which lay a basis for the exact calculation of beam power deposition distribution and neutralization efficiency.
文摘Using ion beam biotechnology in combination with soil-less plant cultivation on artificial substratum (floating beds), the experiments were conducted with Ipomoea aquatica Forsk. Plants were attached to floating-beds which were placed on the surface of artificially nutrient-enriched tank water, in order to study the purification and remediation efficiency of ion beam-treated I. aquatica cultivars. The results show that N + ion beams with 25keV energy and dosages of 0, 2.6, 3.9, 5.2, 6.5, 7.8, 9.1×10 13N +(ions)/cm 2 affected I. aquatica dry seeds differently, with the dose of 3.9×10 13N + (ions)/cm 2 improving effectively the performance as expressed by various biological indices. After ion beam application, I. aquatica cultivars grew well in nutrient-enriched water bodies, increasing the growth of leaves and stem, number of leaves, length and area of roots, plant height, and weight more remarkably than observed in the control. The net removing rates of TN, TP were as high as 75% and 82%, respectively. Especially under the dose of 3.9×10 13N +(ions)/cm 2, the net removing rates of TN, TP were highest, for 77% and 85%, respectively. It was proved that ion beam application improves phytoremediation and may be used to purify nutrient rich water bodies.