期刊文献+
共找到43篇文章
< 1 2 3 >
每页显示 20 50 100
Calculation of Mass Concrete Temperature Containing Cooling Water Pipe Based on Substructure and Iteration Algorithm
1
作者 Heng Zhang Chao Su +2 位作者 Zhizhong Song Zhenzhong Shen Huiguang Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期813-826,共14页
Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for... Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development. 展开更多
关键词 Fourier equation cooling water pipe mass concrete iteration algorithm
下载PDF
Optimization of circulating cooling water systems based on chance constrained programming 被引量:1
2
作者 Bo Liu Yufei Wang Xiao Feng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期167-178,共12页
Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained u... Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%). 展开更多
关键词 Circulating cooling water system UNCERTAINTY Chance constrained programming DESIGN OPTIMIZATION SIMULATION
下载PDF
Application of a water cooling treatment and its effect on coal-based reduction of high-chromium vanadium and titanium iron ore 被引量:2
3
作者 Song-tao Yang Mi Zhou +3 位作者 Tao Jiang Shan-fei Guan Wei-jun Zhang Xiang-xin Xue 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第12期1353-1359,共7页
A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), ... A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (Rs), and P removal ratio (Rp) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350℃ were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, Rs, and Rp in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350℃, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation. 展开更多
关键词 MAGNETITE ore reduction water cooling METALLIZATION magnetic separation
下载PDF
Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water 被引量:2
4
作者 李金波 翟文 +1 位作者 郑茂盛 朱杰武 《Journal of Pharmaceutical Analysis》 SCIE CAS 2008年第1期33-37,60,共6页
The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarizati... The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times. 展开更多
关键词 stainless steel TEMPERATURE chloride ions sulfide ions simulated cooling water
下载PDF
Application of Cooling Water in Controlled Runout Table Cooling on Hot Strip Mill 被引量:2
5
作者 LIUZheng-dong IVSamarasekera 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2004年第3期15-23,共9页
The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to ... The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to study the heat transfer by water jet impingement boiling during runout,apilot facility was constructed at the University of British Columbia.On this pilot facility,the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters,such as cooling water temperature,water jet impingement velocity,initial strip temperature,water flow rate,water nozzle diameter and array of water nozzles,on the heat transfer of heated strip.The results obtained contribute to the optimization of cooling water during runout. 展开更多
关键词 cooling water controlled runout table hot strip mill
下载PDF
CFD Analysis and Optimization of a Diesel Engine Cooling Water Jacket 被引量:1
6
作者 Shunshun Qin Chengfen Xie +3 位作者 Song Li Qi Yang Jianwei Chen Ke Sun 《Fluid Dynamics & Materials Processing》 EI 2022年第3期647-659,共13页
The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.... The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail. 展开更多
关键词 Diesel engine cooling water jacket CFD
下载PDF
Influence of CO_(2) inleakage on the slight-alkalization of generator internal cooling water
7
作者 Tianping Wang Xuxiang Jia +1 位作者 Yu Wang Chunsong Ye 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第8期91-97,共7页
The slight-alkalization of generator internal cooling water(GICW)is widely used to inhibit the corrosion of hollow copper conductor and thereby ensure the safe operation of the generator.CO_(2) inleakage is increasing... The slight-alkalization of generator internal cooling water(GICW)is widely used to inhibit the corrosion of hollow copper conductor and thereby ensure the safe operation of the generator.CO_(2) inleakage is increasingly identified as a potential security risk for GICW system.In this paper,the influence of CO_(2) inleakage on the slight-alkalization of GICW was theoretically discussed.Based on the equilibriums of the CO_(2)-NaOH-H_(2)O system,CO_(2) inleakage saturation was derived to quantify the amount of the dissolved CO_(2) in GICW.This parameter can be directly calculated with the measured conductivity and the[Na+]of GICW.The influence of CO_(2) inleakage on the slight-alkalization conditioning of GICW and the measurement of its water quality parameters were then analyzed.The more severe the inleakage,the narrower the water quality operation ranges of GICW,resulting in the more difficult the slight-alkalization conditioning of GICW.The temperature calibrations of the conductivity and the pH value of GICW show nonlinear correlations with the amount of CO_(2) inleakage and the NaOH dosage.This study provides insights into the influence of CO_(2) inleakage on the slight-alkalization of GICW,which can serve as the theoretical basis for the actual slight-alkalization when CO_(2) inleakage occurs. 展开更多
关键词 Generator internal cooling water(GICW) Hollow copper conductor CO_(2)inleakage Slight-alkalization Temperature calibration
下载PDF
Effects of air-atomized water spray cooling device structure on the quenching process,microstructure,and properties of wear-resistant steel
8
作者 WEN Shibo WU Jianfeng ZHU Jianhua 《Baosteel Technical Research》 CAS 2022年第2期35-41,共7页
With its high strength and hardness, wear-resistant steel has become an important material in the field of construction machinery manufacturing.Given that quenching technology is a crucial component of wear-resistant ... With its high strength and hardness, wear-resistant steel has become an important material in the field of construction machinery manufacturing.Given that quenching technology is a crucial component of wear-resistant steel production, the selection of the cooling method to be used during this process is important.In this study, the feasibility of quenching wear-resistant steel by air-atomized water spray cooling was studied, and the cooling rate, microstructure, and hardness of wear-resistant steel under various cooling device structures were analyzed.The results reveal that the air-atomized water spray cooling method is an effective technique in quenching wear-resistant steel.Furthermore, martensite and uniform hardness were obtained by the air-atomized water spray cooling technique.As the space between the nozzles in each row in the device increased, the cooling rate was reduced during quenching.Meanwhile, the martensite content decreased, and more carbides were observed in the martensitic structure.A mixture comprising self-tempered martensite and bainite was formed at a large distance over a longer period of time.All these factors resulted in lower hardness and worse property uniformity. 展开更多
关键词 wear-resistant steel air-atomized water spray cooling cooling rate MICROSTRUCTURE HARDNESS
下载PDF
Cooling Water Flow Rate Calculation for Hearth of Large Blast Furnaces
9
作者 LI Hengxu CHE Yiunan +2 位作者 ZHOU Zhe WANG Qi WANG Hongtao 《China's Refractories》 CAS 2015年第2期16-20,共5页
The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requ... The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requirements of the increasing smelting intensity and to ensure the safety at the end of the first campaign,the designed maximum cooling water flow rate should be 5 900m3/ h; according to the flow distribution stability and the calculated resistance loss,hearth cooling stave pipes with the specification of 76 mm × 6 mm shall be adopted to assure the flow velocity in pipes of hearth cooling stave in the range of 1. 9- 2. 3 m / s. 展开更多
关键词 hearth of blast furnaces cooling water flow rate simulation calculation
下载PDF
Cooling System Design and Thermal Analysis of Modular Stator Hybrid Excitation Synchronous Motor
10
作者 Shengnan Wu Daquan Hao Wenming Tong 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期241-251,共11页
Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind... Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind power generation and other fields. This paper introduces the basic structure of hybrid excitation motor with modular stator, and analyzes the operation principle of hybrid excitation motor. The cooling structure of the water-cooled plate is designed, and the effects of the thickness of the water-cooled plate and the number of water channels in the water-cooled plate on the heat dissipation capacity of the water-cooled plate are analyzed by theoretical and computational fluid dynamics methods. The effects of different water cooling plate structures on water velocity, pressure drop, water pump power consumption and heat dissipation capacity were compared and analyzed. The influence of different inlet flow velocity on the maximum temperature rise of each part of the motor is analyzed, and the temperature of each part of the motor under the optimal water flow is analyzed. The influence of the traditional spiral water jacket cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of the motor components is compared and analyzed. The results show that the water-cooled plate cooling structure is more suitable for the modular stator motor studied in this paper. Based on the water-cooled plate cooling structure, the air-water composite cooling structure is designed, and the effects of the air-water composite cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of each component of the motor are compared and analyzed. The results show that the maximum temperature rise of each component of the motor is reduced under the air-water composite cooling structure. 展开更多
关键词 Hybrid excitation synchronous motor cooling structure of the water-cooled plate The heat dissipation capacity of the water-cooled plate The maximum temperature rise of each part Air water composite cooling structure
下载PDF
Strength-ductility balance of AZ31 magnesium alloy via accumulated extrusion bonding combined with two-stage artificial cooling Author links open overlay panel
11
作者 Tingzhuang Han Guangsheng Huang +3 位作者 Heng Li Lifei Wang Hua Zhang Fusheng Pan 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第5期1549-1555,共7页
AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage ar... AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage artificial cooling in this work,viz.local water cooling and artificial cooling.The microstructure developed consecutively as a result of discontinuous dynamic recrystallization(DDRX)for the AEBed samples.{10-12}tensile twinning also played an important role for the AEB with local water cooling at the initial extrusion stage in the container.Local water cooling could further reduce the DRXed grain size to~2.1µm comparing that without water cooling.And the grain growth rate was reduced by artificial cooling out of extrusion die.Under the combination of two-stage cooling,the fine DRXed grains at sizing band were almost retained with average grain size of~2.3µm after the sheet out of extrusion die,and the unDRXed grains with high residual dislocation density accumulation were also reserved.The tensile tests results indicated that a good strength-ductility balance with a high ultimate tensile strength(319 MPa vs.412 MPa)and fracture elongation(19.9%vs.30.3%)were obtained.The strength enhancement was mainly owing to the grain refinement and local residual plastic strain reserved by the artificial cooling.The excellent ductility originated from fine DRXed microstructure and ED-tilt double peak texture. 展开更多
关键词 Magnesium alloy Accumulated extrusion bonding Local water cooling Artificial cooling Microstructure Mechanical properties
下载PDF
Removal of kathon by UV-C activated hydrogen peroxide:Kinetics,mechanisms,and enhanced biodegradability assessment
12
作者 Jinzhi Cui Guiqiao Wang +6 位作者 Xing Rong Wensu Gao Yaxin Lu Yawen Luo Lichao Zhang Zhongfa Cheng Canzhu Gao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第1期178-187,共10页
Kathon(CMI-MI),a mixture of 5-chloro-2-methyl-4-isothiazolin-3-one(CMI)and 2-methyl-4-isothiazolin-3-one(MI),was extensively used in industry as a nonoxidizing biocide or disinfectant.However,it would show adverse eff... Kathon(CMI-MI),a mixture of 5-chloro-2-methyl-4-isothiazolin-3-one(CMI)and 2-methyl-4-isothiazolin-3-one(MI),was extensively used in industry as a nonoxidizing biocide or disinfectant.However,it would show adverse effects on aquatic life when it is discharged into surface water.In this study,the removal performance,parameter influence,degradation products and enhancement of subsequent biodegradation of CMI-MI in UV/H_(2)O_(2)system were systematically investigated.The degradation rate of CMI-MI could reach 90%under UV irradiation for 20 min when the dosage of H_(2)O_(2)was 0.3 mmol·L^(–1).The DOC(dissolved organic carbon)mineralization rate of CMI-MI could reach 35%under certain conditions([H_(2)O_(2)]=0.3 mmol·L^(–1),UV irradiation for 40 min).kobs was inversely proportional to the concentration of CMI-MI and proportional to the concentration of H_(2)O_(2).The degradation rate of CMIMI was almost unchanged in the pH range from 4 to 10.Except the presence of CO_(3)^(2-)inhibited the removal rate of CMI-MI,SO_(4)^(2-),Cl^(-),NO_(3)^(-),and NH_(4)^(+) did not interfere with the degradation of CMI-MI in the system.It was found that UV/H_(2)O_(2)system had lower energy consumption and more economic advantage compared with UV/PS system by comparing the EEO(electric energy per order)values under the same conditions.Two main organic products were identified,namely HCOOH and CH_(3)NH_(2).There’s also the formation of Cl^(-)and SO_(4)^(2-).After UV and UV/H_(2)O_(2)photolysis,the biochemical properties of CMI-MI solution were obviously improved,especially the UV/H_(2)O_(2)treatment effect was better,indicating that UV/H_(2)O_(2)technology is expected to combine with biotechnology to remove CMI-MI effectively and environmentally friendly from wastewater. 展开更多
关键词 Kathon UV/H_(2)O_(2) Biological degradation Circulating cooling water
下载PDF
Model free optimization of building cooling water systems with refined action space
13
作者 Qiaofeng Xiong Zhengwei Li +1 位作者 Wenxia Cai Zhechao Wang 《Building Simulation》 SCIE EI CSCD 2023年第4期615-627,共13页
Deep Q Network(DQN)is an efficient model-free optimization method,and has the potential to be used in building cooling water systems.However,due to the high dimension of actions,this method requires a complex neural n... Deep Q Network(DQN)is an efficient model-free optimization method,and has the potential to be used in building cooling water systems.However,due to the high dimension of actions,this method requires a complex neural network.Therefore,both the required number of training samples and the length of convergence period are barriers for real application.Furthermore,penalty function based exploration may lead to unsafe actions,causing the application of this optimization method even more difficult.To solve these problems,an approach to limit the action space within a safe area is proposed in this paper.First of all,the action space for cooling towers and pumps are separated into two sub-regions.Secondly,for each type of equipment,the action space is further divided into safe and unsafe regions.As a result,the convergence speed is significantly improved.Compared with the traditional DQN method in a simulation environment validated by real data,the proposed method is able to save the convergence time by 1 episode(one cooling season).The results in this paper suggest that,the proposed DQN method can achieve a much quicker learning speed without any undesired consequences,and therefore is more suitable to be used in projects without pre-learning stage. 展开更多
关键词 building cooling water system cooling tower cooling water pump DQN controller convergence speed
原文传递
Optimization of rhizosphere cooling airflow for microclimate regulation and its effects on lettuce growth in plant factory 被引量:2
14
作者 LI Kun FANG Hui +1 位作者 ZOU Zhi-rong CHENG Rui-feng 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2021年第10期2680-2695,共16页
In plant factories,the plant microclimate is affected by the control system,plant physiological activities and aerodynamic characteristics of leaves,which often leads to poor ventilation uniformity,suboptimal environm... In plant factories,the plant microclimate is affected by the control system,plant physiological activities and aerodynamic characteristics of leaves,which often leads to poor ventilation uniformity,suboptimal environmental conditions and inefficient air conditioning.In this study,interlayer cool airflow(ILCA)was used to introduce room air into plants’internal canopy through vent holes in cultivation boards and air layer between cultivation boards and nutrient solution surface(interlayer).By using optimal operating parameters at a room temperature of 28℃,the ILCA system achieved similar cooling effects in the absence of a conventional air conditioning system and achieved an energy saving of 50.8% while bringing about positive microclimate change in the interlayer and nutrient solution.This resulted in significantly reduced root growth by 41.7% without a negative influence on lettuce crop yield.Future development in this precise microclimate control method is predicted to replace the conventional cooling(air conditioning)systems for crop production in plant factories. 展开更多
关键词 air movement environmental control MICROCLIMATE water cooling root and shoot growth
下载PDF
Optimal Design of Multi-channel Water Cooled Radiator for Motor Controller of New Energy Vehicle 被引量:4
15
作者 Zhu Zhang Yunfan Liu Jingyuan Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期87-94,共8页
In order to improve the heat dissipation capability of motor controller for new energy vehicles,the water cooled radiator with multiple channels is optimized in this paper.The heat conduction between the heat source I... In order to improve the heat dissipation capability of motor controller for new energy vehicles,the water cooled radiator with multiple channels is optimized in this paper.The heat conduction between the heat source IGBT and the radiator,the convective heat transfer between the radiator and the coolant,the mechanical strength and the manufacturing cost are comprehensively considered during the optimization process.The power loss and thermal resistance of the IGBT unit are calculated at first,and finite element model of the radiator is established.On this basis,multi-physics coupling analysis of the water cooled radiator is carried out.Secondly,the sensitivity analysis is applied to verify the influence of structural parameters on the heat dissipation performance of the radiator system.The influence of coolant inlet velocity v,number of cooling ribs n,height of radiator ribs H on the maximum temperature rise T,the temperature difference ΔT between phase U and W,and the coolant pressure lossΔP are analyzed in depth,and the optimal range of the structural parameters for heat dissipation is obtained.Finally,an experimental platform was set up to verify the performance of the proposed structure of water cooled radiator for motor controller of new energy vehicle.The results show that the heat dissipation capability of the proposed radiator is improved compared with the initial design. 展开更多
关键词 Motor controller water cooled radiator Finite element method New energy vehicle
下载PDF
Corrosion of candidate materials for supercritical water-cooled reactor
16
作者 ZHANG Lefu~(1)),BAO Yichen~(1)) and TANG Rui~(2)) 1) School of Nuclear Sci.&Eng,Shanghai Jiao Tong Univ.,Shanghai 200240,China 2) National Key Laboratory for Nuclear Fuel and Materials,Nuclear Power Institute of China,Chengdu 610041,China 《Baosteel Technical Research》 CAS 2010年第S1期71-,共1页
Supercritical water reactor(SCWR) was proposed as a GenerationⅣconcept for building large capacity nuclear power plants.Comparing with the present GenerationⅡandⅢlight water reactors,SCWR possesses great advantages... Supercritical water reactor(SCWR) was proposed as a GenerationⅣconcept for building large capacity nuclear power plants.Comparing with the present GenerationⅡandⅢlight water reactors,SCWR possesses great advantages of 10%higher efficiency,simpler system design,better sustainability,and so on. However,the selection of materials for fuel cladding and reactor internals of SCWR is facing a great challenge. Corrosion in supercritical steam is of the first important issue to be solved to meet the stringent requirement of the reactor internal components.Corrosion screening tests were conducted on candidate materials for nuclear fuel cladding and reactor internals of supercritical water reactor(SCWR) in static and re-circulating autoclave at the temperatures of 550,600 and 650℃,pressure of about 25 MPa,deaerated or saturated dissolved hydrogen(STP). Nickel base alloy type Hastelloy C276,austenitic stainless steels type 304NG,AL-6XN,HR3C.NF709 and SAVE 25,ferritic/martensitic(F/M) steel type P92,P122 and 410,and oxide dispersion strengthened steel MA 956,are tested.This paper presents corrosion rate,and focuses on the formation and breakdown of corrosion oxide film,and proposes the future trend for the development of SCWR internal structure materials. 展开更多
关键词 supercritical water cooled reactor cladding material CORROSION protective oxide film
下载PDF
Cool water brought by upwelling in the Sanya Bay benefits corals in the background of global warming
17
作者 YANG Dingtian 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第3期14-19,共6页
It has been reported that global warming has negative effects on coral ecosystems in the past 50 years and the effects vary in different ocean environment. In order to make clear the coral reef status in the backgroun... It has been reported that global warming has negative effects on coral ecosystems in the past 50 years and the effects vary in different ocean environment. In order to make clear the coral reef status in the background of global warming along the south coast of Hainan Island of China, satellite and in situ data are used to retrieve the information of the coral reef status and surrounding environmental factors. The results show that cool water induced by upwelling along the south coast of Hainan Island is found in the area every summer month, especially in the relatively strong El Ni?o years(2002–2003 and 2005). From the NOAA satellite data, degree heating week(DHW) index does not exceed 3 in Sanya Bay even in the relatively strong El Ni?o years. By comparison of a coral reef growth rate in the Sanya Bay with respect to El Ni?o events from 1957 to 2000, coral's growth rate is relatively greater during 1972, 1991–1994 and 1998 El Ni?o event. By analyzing the environmental factors, it is found that the cool water induced by upwelling may be the main reason for protecting corals from global warming effects. 展开更多
关键词 cool water upwelling corals degree heating week Sanya Bay
下载PDF
A Study of Water Treatment Chemical Effects on Type I” Pitting Corrosion of Copper Tubes
18
作者 Takashi Iyasu Motoki Kuratani +3 位作者 Itaru Ikeda Noriyuki Tanaka Yutaka Yamada Osamu Sakurada 《Materials Sciences and Applications》 2020年第7期494-504,共11页
It is known that one of the causes of pitting corrosion of copper tubes is residual carbon on the inner surface. It was confirmed that type I” pitting corrosion of the copper tube is suppressed by keeping the residua... It is known that one of the causes of pitting corrosion of copper tubes is residual carbon on the inner surface. It was confirmed that type I” pitting corrosion of the copper tube is suppressed by keeping the residual carbon amount at 2 mg/m<sup>2</sup> or less, which is lower than that of the type I’ pitting corrosion, or by removing the fine particles that are the corrosion product of galvanized steel pipes. The developed water treatment chemical was evaluated using three types of copper tubes with residual carbon amounts of 0 mg/m<sup>2</sup>, 0.5 mg/m<sup>2</sup>, and 6.1 mg/m<sup>2</sup>. The evaluation was conducted for three months in an open-circulation cooling water system and compared with the current water treatment chemical. Under the current water treatment chemical conditions, only the copper tube with a residual carbon amount of 6.1 mg/m<sup>2</sup> showed a significant increase in the natural corrosion potential after two weeks, and pitting corrosion occurred. No pitting corrosion and no increase in the natural corrosion potential were observed in any of the copper tubes that were treated with the developed water treatment chemical. In addition, the polarization curve was measured using the cooling water from this field test, and the anodic polarization of two cooling waters was compared. For copper tubes with a large amount of residual carbon, the current density near 0 mV vs. Ag/AgCl electrode (SSE) increased when the developed water treatment chemical was added. 展开更多
关键词 Copper Tube Pitting Corrosion Residual Carbon cooling water system water Treatment
下载PDF
PARAMETERS OF WATER CIRCULATION NETWORK FOR A DISTRICT HEATING AND COOLING SYSTEM
19
作者 Fu, Lin Pan, Jihong Jiang, Yi 《Journal of Hydrodynamics》 SCIE EI CSCD 2000年第1期87-95,共9页
In a district heating and cooling system, i.e. Beijing combined heating cooling and power (CHCP) system studied here, the high temperature water generated by two cogeneration plants circulates through a network betwee... In a district heating and cooling system, i.e. Beijing combined heating cooling and power (CHCP) system studied here, the high temperature water generated by two cogeneration plants circulates through a network between the plants and heat substations. At heat substations, the supply water of high temperature from the network drives absorption chillers for air-conditioning in summer and meets space heating demands in winter or domestic hot water demands by heat exchangers in the whole year. The parameters, i.e. supply/return water temperatures in the network, have a great impact on primary energy consumption (PEC) of the absorption chillers, circulation pumps and domestic hot water (DHW), which is studied in this paper. 展开更多
关键词 Boiler circulation Energy utilization Hot water heating Parameter estimation water cooling systems
原文传递
Preparation and application of a phosphorous free and non- nitrogen scale inhibitor in industrial cooling water systems 被引量:3
20
作者 Guangqing LIU Mengwei XUE +10 位作者 Jingyi HUANG Huchuan WANG Yuming ZHOU Qingzhao YAO Lei LING Ke CAO Yahui LIU Yunyun BU Yiyi CHEN Wendao WU Wei SUN 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2015年第3期545-553,共9页
A novel environmentally friendly type of calcium carbonate, zinc (Ⅱ) and iron (Ⅲ) scale inhibitor Acrylic acidallylpolyethoxy carboxylate copolymer (AA- APEL) was synthesized. The anti-scale property of the AA... A novel environmentally friendly type of calcium carbonate, zinc (Ⅱ) and iron (Ⅲ) scale inhibitor Acrylic acidallylpolyethoxy carboxylate copolymer (AA- APEL) was synthesized. The anti-scale property of the AA-APEL toward CaCO3, zinc (Ⅱ) and iron (Ⅲ) in the artificial cooling water was studied through static scale inhibition tests. The observation shows that both calcium carbonate, zinc (Ⅱ) and iron (Ⅲ) inhibition increase with increasing the dosage of AA-APEL. The effect on formation of CaCO3 was investigated with combination of scanning electronic microscopy (SEM), transmission electron microscopy (TEM), X-ray powder diffraction (XRD) analysis and fourier transform infrared spectrometer, respectively. The results showed that the AA-APEL copolymer not only influenced calcium carbonate crystal morphology and crystal size but also the crystallinity. The crystallization of CaCO3 in the absence of inhibitor was rhombohedral calcite crystal, whereas a mixture of calcite with vaterite crystals was found in the presence of the AA- APEL copolymer. Inhibition mechanism is proposed that the interactions between calcium or iron ions and polyethylene glycol (PEG) are the fundamental impetus to restrain the formation of the scale in cooling water systems. 展开更多
关键词 phosphorous free calcium carbonate stabilize zinc (Ⅱ) disperse iron (Ⅲ) cooling water
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部