期刊文献+
共找到11,091篇文章
< 1 2 250 >
每页显示 20 50 100
The Optimization Design of the Nozzle Section for theWater Jet Propulsion System Applied in Jet Skis
1
作者 Cheng-Yeh Li Jui-Hsiang Kao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2277-2304,共28页
The performance of a water jet propulsion system is related to the inlet duct,rotor,stator,and nozzle.Generally,the flow inlet design must fit the bottom line of the hull,and the design of the inlet duct is often limi... The performance of a water jet propulsion system is related to the inlet duct,rotor,stator,and nozzle.Generally,the flow inlet design must fit the bottom line of the hull,and the design of the inlet duct is often limited by stern space.The entire section,from the rotor to the nozzle through the stator,must be designed based on system integration in that the individual performance of these three components will influence each other.Particularly,the section from the rotor to the nozzle significantly impacts the performance of a water jet propulsion system.This study focused on nozzle design and established referable analysis results to facilitate subsequent integrated studies on the design parameters regarding nozzle contour.Most existing studies concentrate on discussions on rotor design and the tip leakage flow of rotors or have replaced the existing complex computational domain with a simple flow field.However,research has yet to implement an integrated,optimal design of the section from the rotor to the nozzle.Given the above,our program conducted preliminary research on this system integration design issue,discussed the optimal nozzle for this section in-depth,and proposed design suggestions based on the findings.This program used an existing model as the design case.This study referred to the actual trial data as the design conditions for the proposed model.Unlike prior references’simple flow field form,this study added a jet ski geometry and free surface to the computational domain.After the linear hull shape was considered,the inflow in the inlet duct would be closer to the actual condition.Based on the numerical calculation result,this study recommends that the optimal nozzle outlet area should be 37%of the inlet area and that the nozzle contour should be linear.Furthermore,for the pump head,static pressure had a more significant impact than dynamic pressure. 展开更多
关键词 water jet propulsion system rotor nozzle outlet area nozzle contour
下载PDF
Calculation of Mass Concrete Temperature Containing Cooling Water Pipe Based on Substructure and Iteration Algorithm
2
作者 Heng Zhang Chao Su +2 位作者 Zhizhong Song Zhenzhong Shen Huiguang Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期813-826,共14页
Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for... Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development. 展开更多
关键词 Fourier equation cooling water pipe mass concrete iteration algorithm
下载PDF
Experimental Study on the Resistance and Splash Performances of Water Collecting Devices for Mechanical Draft Cooling Towers
3
作者 Guoqing Long Guogang Zhang +3 位作者 Qi Zhang Cuilin Zhao Suoying He Fengzhong Sun 《Fluid Dynamics & Materials Processing》 EI 2023年第7期1789-1801,共13页
In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To ex... In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To explore the feasibility of this approach for mechanical draft cooling towers,a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices(WCDs)for different water flow rates and wind speeds.The experimental results show that within the considered ranges of wind speed and water flow rate,the pressure drop of the different WCDs can vary significantly.The resistance and local splash performances can also be remarkably different.Some recommendations about the most suitable system are provided.Moreover,a regression analysis of the experimental data is conducted,and the resulting fitting formulas for resistance and splash performance of WCD are reported. 展开更多
关键词 Mechanical draft cooling towers water collecting device resistance performance splash performance fitting formulas
下载PDF
Design and analysis of a high loss density motor cooling system with water cold plates
4
作者 Xin Zhao Haojie Cui +2 位作者 Yun Teng Zhe Chen Guangwei Liu 《Global Energy Interconnection》 EI CSCD 2023年第3期343-354,共12页
Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect o... Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor. 展开更多
关键词 cooling system design High loss density motor water cold plate Temperature field analysis
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
5
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
城市化进程的加快意味着城市和国际组织需要去寻找各种能够提高能源效率和减少空气中污染物排放的方法。冷热电联产(CCHP)系统可以同时供暖、制冷和发电,具有提高城市或城市区域能源发电效率的潜力。本研究的目的是在满足建筑热需求(供... 城市化进程的加快意味着城市和国际组织需要去寻找各种能够提高能源效率和减少空气中污染物排放的方法。冷热电联产(CCHP)系统可以同时供暖、制冷和发电,具有提高城市或城市区域能源发电效率的潜力。本研究的目的是在满足建筑热需求(供热和制冷)的各种运行条件下,对亚特兰大大都市区内的五种常见建筑类型在采用CCHP系统时的发电耗水、CO_2和NO_x排放,及其经济性进行评价。对于大多数采用或不采用净计量策略的建筑类型来说,以满足每小时热需求去运行CCHP系统均可减少CO_2的排放量。该系统能否对这些建筑类型产生经济效益,主要取决于天然气的价格、净计量策略的采用和假定的CCHP系统的成本结构。当建筑物采用净计量策略并且CCHP系统是以满足建筑物每年的最大热需求而运行时,CCHP系统的发电耗水量和NO_x的排放量均有最大限度的减少,尽管此时该运行情景会增加温室气体排放和发电成本。CCHP系统对中型办公楼、大型办公楼和多户型住宅建筑更经济、实用。 展开更多
关键词 电力系统 空气冷却 供热成本 亚特兰大 微型燃气轮机 空气污染 冷热电联供系统 二氧化碳排放
下载PDF
Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water 被引量:2
6
作者 李金波 翟文 +1 位作者 郑茂盛 朱杰武 《Journal of Pharmaceutical Analysis》 SCIE CAS 2008年第1期33-37,60,共6页
The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarizati... The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times. 展开更多
关键词 stainless steel TEMPERATURE chloride ions sulfide ions simulated cooling water
下载PDF
Optimization of circulating cooling water systems based on chance constrained programming 被引量:3
7
作者 Bo Liu Yufei Wang Xiao Feng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期167-178,共12页
Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained u... Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%). 展开更多
关键词 Circulating cooling water system UNCERTAINTY Chance constrained programming DESIGN OPTIMIZATION SIMULATION
下载PDF
Possibilities of Using Solar Energy in District Cooling Systems in the Mediterranean Region 被引量:2
8
作者 John Vourdoubas 《Open Journal of Energy Efficiency》 2019年第2期21-34,共14页
Use of district heating and cooling systems has many environmental advantages compared to individual heating and cooling. Recent advances in solar energy technologies for heat and power generation have reduced their c... Use of district heating and cooling systems has many environmental advantages compared to individual heating and cooling. Recent advances in solar energy technologies for heat and power generation have reduced their cost and promoted their use instead of fossil fuels. Solar-PV energy for electricity generation and solar thermal energy for hot water production are broadly used today. Solar energy resources in the Mediterranean region are abundant while space cooling in buildings is required when solar irradiance is high. The possibility of using solar energy for fuelling water chillers providing cold water in district cooling systems in the Mediterranean basin has been investigated. Existing literature and studies concerning the use of district cooling systems globally as well as the energy sources used in them have been examined. Solar-PV energy combined with compression chillers and solar thermal energy combined with thermally driven chillers can be used for cold water production. Their overall efficiencies, converting solar energy to cold water, vary between 22% and 56% compared with 45% for compression chillers using grid electricity. It is concluded that various solar energy technologies could be used with different types of water chillers for fuelling district cooling networks in the future in the Mediterranean region. 展开更多
关键词 DISTRICT cooling EFFICIENCY Mediterranean REGION SOLAR Energy water Chillers
下载PDF
Energy, Exergy and Thermoeconomics Analysis of Water Chiller Cooler for Gas Turbines Intake Air Cooling 被引量:1
9
作者 Galal Mohammed Zaki Rahim Kadhim Jassim Majed Moalla Alhazmy 《Smart Grid and Renewable Energy》 2011年第3期190-205,共16页
Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the... Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff. 展开更多
关键词 Gas Turbine EXERGY Analysis Power BOOSTING Hot Climate Air cooling water CHILLER
下载PDF
Effects of Nutrients on Biofouling Formation and Preponderant Bacteria Diversity in Recirculating Cooling Water System 被引量:2
10
作者 Ma Tao Liu Fang +1 位作者 Zhang Guizhi Zhao Chaocheng (College of Chemistry and Chemical Engineering,China University of Petroleum,Qingdao 266555) 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2010年第4期57-62,共6页
一系列直角的数组实验作为主要用碳来源,氨氮和全部的磷(TP ) 被进行影响因素在使水系统凉下来的 recirculating 在 biofouling 形成和优势的细菌差异上调查营养素的效果。碳来源被表明是影响 biofouling 形成的最重要的决定因素。当 B... 一系列直角的数组实验作为主要用碳来源,氨氮和全部的磷(TP ) 被进行影响因素在使水系统凉下来的 recirculating 在 biofouling 形成和优势的细菌差异上调查营养素的效果。碳来源被表明是影响 biofouling 形成的最重要的决定因素。当 BOD5, NH4+-N 和 TP 分别地是 25, 10,和 1 mg/L 时,最小的 biofouling 结果被获得。然后,在 biofouling 的优势的细菌紧张集中在 twotypical 文化条件下面(否定、有利)被识别与种系发生的联营分析使用传统的生物化学的方法和进一步分子的生物学技术,它显示了那 Enterobacteriaceae Enterobacter , Micrococcaceae 葡萄球菌, Bacillaceae 杆菌, Enterobacteriaceae 盲螈属, Neisseriaceae Neis-seria 和 Pseudomonadaceae Pseudomonas 在否定状况下面是主导的,当时 展开更多
关键词 循环冷却水系统 生物污染 优势菌 多样性 分子生物学技术 芽孢杆菌属 养分 肠杆菌属
下载PDF
Soft-Sensing Method of Water Temperature Measurement for Controlled Cooling System
11
作者 CAIXiao-hui ZHANGDian-hua +2 位作者 WANGGuo-dong LIUXiang-hua FANLei 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2003年第4期71-74,共4页
Aiming at the water temperature measuring problem for controlled cooling system of rolling plant,a new water temperature measuring method based on soft-sensing method with a water temperature model of on-line self cor... Aiming at the water temperature measuring problem for controlled cooling system of rolling plant,a new water temperature measuring method based on soft-sensing method with a water temperature model of on-line self correction parameter was built.A water temperature compensation factor model was also built to improve coiling temperature control precision.It was proved that the model meets production requirements.The soft-sensing technique has extensive applications in the field of metal forming. 展开更多
关键词 soft-sensing controlled cooling water temperature model correction model
下载PDF
Corrosion Prevention of the Generator Stator Hollow Copper Conductor and Water Quality Adjustment of Its Internal Cooling Water 被引量:2
12
作者 Ling PAN Qianqian HAN +2 位作者 Xuenong XIE Xuejun XIE Peng XIAO 《Energy and Power Engineering》 2009年第1期17-20,共4页
On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling gene... On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed. 展开更多
关键词 GENERATOR INTERNAL cooling-water HOLLOW COPPER conductor corrosion and protection
下载PDF
Nonlinear Vibration Induced by the Water-film Whirl and Whip in a Sliding Bearing Rotor System 被引量:3
13
作者 ZHAI Liming LUO Yongyao +2 位作者 WANG Zhengwei KITAUCHI Seishiro MIYAGAWA Kazuyoshi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第2期260-270,共11页
Many industrial applications and experiments have shown that sliding bearings often experience fluid film whip due to nonlinear fluid film forces which can cause rotor-stator rub-impact failures. The oil-film whips ha... Many industrial applications and experiments have shown that sliding bearings often experience fluid film whip due to nonlinear fluid film forces which can cause rotor-stator rub-impact failures. The oil-film whips have attracted many studies while the water-film whips in the water lubricated sliding bearing have been little researched with the mechanism still an open problem. The dynamic fluid film forces in a water sliding bearing are investigated numerically with rotational, whirling and squeezing motions of the journal using a nonlinear model to identify the relationships between the three motions. Rotor speed-up and slow-down experiments are then conducted with the rotor system supported by a water lubricated sliding bearing to induce the water-film whirl/whip and verify the relationship. The experimental results show that the vibrations of the journal alternated between increasing and decreasing rather than continuously increasing as the rotational speed increased to twice the first critical speed, which can be explained well by the nonlinear model. The radial growth rate of the whirl motion greatly affects the whirl frequency of the journal and is responsible for the frequency lock in the water-film whip. Further analysis shows that increasing the lubricating water flow rate changes the water-film whirl/whip characteristics, reduces the first critical speed, advances the time when significant water-film whirling motion occurs, and also increases the vibration amplitude at the bearing center which may lead to the rotor-stator rub-impact. The study gives the insight into the water-film whirl and whip in the water lubricated sliding bearing. 展开更多
关键词 rotor system sliding bearing vibration water-film whip nonlinear
下载PDF
Simulation of Gas-Fired Triple-Effect LiBr/Water Absorption Cooling System with Exhaust Heat Recovery Generator 被引量:1
14
作者 汪磊磊 由世俊 +1 位作者 张欢 李宪莉 《Transactions of Tianjin University》 EI CAS 2010年第3期187-193,共7页
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no... An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles. 展开更多
关键词 吸收制冷系统 发电机 溴化锂 水冷却 排气余热 燃气 蒸汽发生器 仿真
下载PDF
Risk Assessment of Mediterranean Sea Waters on Cooling System of Nuclear Power Plant
15
作者 M. S. Tawfik F. S. Tawfik 《Journal of Environmental Protection》 2019年第6期738-744,共7页
The study evaluated the impacts such as corrosion and scale formation which may result from, using the once-through pass cooling system of a suggested nuclear power at different selected coastal regions of Alexandria ... The study evaluated the impacts such as corrosion and scale formation which may result from, using the once-through pass cooling system of a suggested nuclear power at different selected coastal regions of Alexandria coast. (Abu-Qir, Sidi Kerrir, Estern Harbour, El Max and Sidi Abd Elrhaman). The study had used The Langelier Saturation Index (LSI), which is a measure of a solution’s ability to dissolve or deposit calcium carbonate, which is often used as an indicator of the corrosivity of water. Like the Langelier saturation index, the Ryznar stability index (RSI) is also used to predicate the formation of scale and also the tendency for corrosion due to the concentration of calcium carbonate in the selected water system. Both of the two indexes ((LSI) and (RSI)) had been used to evaluate the internal environmental impact which may be occurred when used once-through pass system is as a cooling method of a coastal pressurized water reactor power plant. The study results showed that the calculated LSI and RSI values for selected regions indicated that, there was a low tendency for scale formation and possibility of corrosion at these selected study areas, so using nickel copper alloys in condenser is recommended to prevent any possibility of attack of corrosion besides the using of chemical treatment method of inlet cooling water system. 展开更多
关键词 cooling water CORROSION Langelier SATURATION INDEX
下载PDF
Effects of air-atomized water spray cooling device structure on the quenching process,microstructure,and properties of wear-resistant steel
16
作者 WEN Shibo WU Jianfeng ZHU Jianhua 《Baosteel Technical Research》 CAS 2022年第2期35-41,共7页
With its high strength and hardness, wear-resistant steel has become an important material in the field of construction machinery manufacturing.Given that quenching technology is a crucial component of wear-resistant ... With its high strength and hardness, wear-resistant steel has become an important material in the field of construction machinery manufacturing.Given that quenching technology is a crucial component of wear-resistant steel production, the selection of the cooling method to be used during this process is important.In this study, the feasibility of quenching wear-resistant steel by air-atomized water spray cooling was studied, and the cooling rate, microstructure, and hardness of wear-resistant steel under various cooling device structures were analyzed.The results reveal that the air-atomized water spray cooling method is an effective technique in quenching wear-resistant steel.Furthermore, martensite and uniform hardness were obtained by the air-atomized water spray cooling technique.As the space between the nozzles in each row in the device increased, the cooling rate was reduced during quenching.Meanwhile, the martensite content decreased, and more carbides were observed in the martensitic structure.A mixture comprising self-tempered martensite and bainite was formed at a large distance over a longer period of time.All these factors resulted in lower hardness and worse property uniformity. 展开更多
关键词 wear-resistant steel air-atomized water spray cooling cooling rate MICROSTRUCTURE HARDNESS
下载PDF
Controlled Cooling of Hot Rolled Steel Channels by Water Spraying on the Final Cooling Bed
17
作者 Srinivas Rachamadagu Malur Srinivasan 《Modern Mechanical Engineering》 2014年第1期28-34,共7页
The objective of this research is to design an effective and relatively simple method for controlled cooling of hot rolled steel channels by water spraying on the final cooling bed after continuous cast steel billets ... The objective of this research is to design an effective and relatively simple method for controlled cooling of hot rolled steel channels by water spraying on the final cooling bed after continuous cast steel billets passing through reheating furnace and sequential rolls to form channels. The need for this research arose as the channels were being cooled by forced air draft and natural convection which brought the temperature of the channels to about 270°C (518°F) at the shear stand. Steel at this temperature is too hot for convenient handling by the operators. Additional cooling by water spraying would be an acceptable solution but such cooling should be designed to enable an acceptable microstructure to be developed in the channel, as the microstructure of steel is strongly affected by nonequilibrium cooling through the eutectoid range: the mechanical properties of steel are a consequence of the microstructure. The approach followed in this investigation was first to develop a finite element method (FEM) to determine the temperature profiles in the channel subjected to cooling by water spraying and natural convection and arrive at suitable water spray rates to bring the temperature of the channel at the shear stand to levels suitable for convenient handling. PATRAN was used for preprocessing and ABAQUS for processing and post processing. Next, laboratory experiments were conducted to determine the microstructure and hardness of channels at the spray rates found suitable through FEM, to suggest the water spray rate most suitable for providing a temperature convenient for handling and for developing a desirable microstructure. 展开更多
关键词 FINITE Element Method Steel Channel water SPRAY cooling Microstructure NONEQUILIBRIUM cooling
下载PDF
Influence of CO_(2) inleakage on the slight-alkalization of generator internal cooling water
18
作者 Tianping Wang Xuxiang Jia +1 位作者 Yu Wang Chunsong Ye 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第8期91-97,共7页
The slight-alkalization of generator internal cooling water(GICW)is widely used to inhibit the corrosion of hollow copper conductor and thereby ensure the safe operation of the generator.CO_(2) inleakage is increasing... The slight-alkalization of generator internal cooling water(GICW)is widely used to inhibit the corrosion of hollow copper conductor and thereby ensure the safe operation of the generator.CO_(2) inleakage is increasingly identified as a potential security risk for GICW system.In this paper,the influence of CO_(2) inleakage on the slight-alkalization of GICW was theoretically discussed.Based on the equilibriums of the CO_(2)-NaOH-H_(2)O system,CO_(2) inleakage saturation was derived to quantify the amount of the dissolved CO_(2) in GICW.This parameter can be directly calculated with the measured conductivity and the[Na+]of GICW.The influence of CO_(2) inleakage on the slight-alkalization conditioning of GICW and the measurement of its water quality parameters were then analyzed.The more severe the inleakage,the narrower the water quality operation ranges of GICW,resulting in the more difficult the slight-alkalization conditioning of GICW.The temperature calibrations of the conductivity and the pH value of GICW show nonlinear correlations with the amount of CO_(2) inleakage and the NaOH dosage.This study provides insights into the influence of CO_(2) inleakage on the slight-alkalization of GICW,which can serve as the theoretical basis for the actual slight-alkalization when CO_(2) inleakage occurs. 展开更多
关键词 Generator internal cooling water(GICW) Hollow copper conductor CO_(2)inleakage Slight-alkalization Temperature calibration
下载PDF
The Preliminary Research of Sea Water District Heating and Cooling for Tallinn Coastal Area
19
作者 Allan Hani Teet-Andrus Koiv 《Smart Grid and Renewable Energy》 2012年第3期246-252,共7页
This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studie... This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studied for continental climatic conditions. The district network study bases on 21 buildings located near to the Gulf of Finland. Industrial reversible heat pump technology is selected to cover heating and cooling loads for the new buildings. Combination of existing district heating and heat pump technology is considered for existing buildings. The results show possibilities, threats and need for further research of the sea water based heat pump district network implementation. 展开更多
关键词 DISTRICT HEATING cooling SEA water Heat PUMP RENEWABLE Energy office Building
下载PDF
Mathematical model on heat transfer of water-cooling steel-stick bottom electrode of DC electric arc furnace 被引量:1
20
作者 HaiXu XiaoLiu 《Journal of University of Science and Technology Beijing》 CSCD 2002年第5期338-342,共5页
For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mat... For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mathematical model by control capacity methodis built. At the same time, the measurement on the melted depth ofbottom electrode is conducted which verified the correctness of thebuilt mathematical model. On the base of verification, all kinds ofkey parameters are calculated through the application and a series ofresults are simulated. Finally, the optimum parameters are found andthe service life of bottom electrode is prolonged. 展开更多
关键词 DC electric arc furnace water-cooling steel-stick electrode MAtheMATICALMODEL heat transfer
下载PDF