Adopting the quasi-three-dimensional (Quasi-3D) numerical method to optimize the anti-freeze design parameters of an underground pipeline usually involves heavy numerical calculations. Here, the fitting formulae bet...Adopting the quasi-three-dimensional (Quasi-3D) numerical method to optimize the anti-freeze design parameters of an underground pipeline usually involves heavy numerical calculations. Here, the fitting formulae between the safe con-veyance distance (SCD) of a water pipeline and six influencing factors are established based on the lowest water temper-ature (LWT) along the pipeline axis direction. With reference to the current widely used anti-freeze design approaches for underground pipelines in seasonally frozen areas, this paper first analyzes the feasibility of applying the maximum frozen penetration (MFP) instead of the mean annual ground surface temperature (MAGST) and soil water content (SWC) to calculate the SCD. The results show that the SCD depends on the buried depth if the MFP is fixed and the variation of the MAGST and SWC combination does not significantly change the SCD. A comprehensive formula for the SCD is estab-lished based on the relationships between the SCD and several primary influencing factors and the interaction among them. This formula involves five easy-to-access parameters: the MFP, buried depth, pipeline diameter, flow velocity, and inlet water temperature. A comparison between the analytical method and the numerical results based on the Quasi-3D method indicates that the two methods are in good agreement overall. The analytic method can be used to optimize the anti-freeze design parameters of underground water pipelines in seasonally frozen areas under the condition of a 1.5 safety coefficient.展开更多
In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highw...In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highways,railroads,and water supply pipelines,was particularly severe in areas where these structures intersected the seismogenic fault.Critical infrastructure projects that traverse active faults are susceptible to the influence of fault movement,pulse velocity,and ground motions.In this study,we used a unique approach to analyze the acceleration records obtained from the seismic station array(9 strong ground motion stations)located along the East Anatolian Fault(the seismogenic fault of the MW7.8 mainshock of the 2023 Türkiye earthquake doublet).The acceleration records were filtered and integrated to obtain the velocity and displacement time histories.We used the results of an on-site investigation,jointly conducted by China Earthquake Administration and Türkiye’s AFAD,to analyze the distribution of PGA,PGV,and PGD recorded by the strong motion array of the East Anatolian Fault.We found that the maximum horizontal PGA in this earthquake was 3.0 g,and the maximum co-seismic surface displacement caused by the East Anatolian Fault rupture was 6.50 m.As the fault rupture propagated southwest,the velocity pulse caused by the directional effect of the rupture increased gradually,with the maximum PGA reaching 162.3 cm/s.We also discussed the seismic safety of critical infrastructure projects traversing active faults,using two case studies of water supply pipelines in Türkiye that were damaged by earthquakes.We used a three-dimensional finite element model of the PE(polyethylene)water pipeline at the Islahiye State Hospital and fault displacement observations obtained through on-site investigation to analyze pipeline failure mechanisms.We further investigated the effect of the fault-crossing angle on seismic safety of a pipeline,based on our analysis and the failure performance of the large-diameter Thames Water pipeline during the 1999 Kocaeli earthquake.The seismic method of buried pipelines crossing the fault was summarized.展开更多
At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of ...At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of pipeline leakage is of great significance for saving water resources and reducing economic losses.Acoustic emission technology is the most widely used pipeline leak location technology.The traditional non-stationary random signal de-noising method mainly relies on the estimation of noise parameters,ignoring periodic noise and components unrelated to pipeline leakage.Aiming at the above problems,this paper proposes a leak location method for water supply pipelines based on a multivariate variational mode decomposition algorithm.This method combines the two parameters of the energy loss coefficient and the correlation coefficient between adjacent modes,and adaptively determines the decomposition mode number K according to the characteristics of the signal itself.According to the correlation coefficient,the effective component is selected to reconstruct the signal and the cross-correlation time delay is estimated to determine the location of the pipeline leakage point.The experimental results show that this method has higher accuracy than the cross-correlation method based on VMD and the cross-correlation method based on EMD,and the average relative positioning error is less than 2.2%.展开更多
In this work, historical background of power generation by small hydro-power plants across the world and specially across the Iran with emphasis on small hydro-power plant utilization as recovery turbine in water tran...In this work, historical background of power generation by small hydro-power plants across the world and specially across the Iran with emphasis on small hydro-power plant utilization as recovery turbine in water transmission pipeline have been attended firstly, and then, three water transmission pipelines from Chah-nemie to Zahedan city, Shirindare dam to Bojnord city and Mokhtaran desert to Birjand city in Iran have been studied as case study samples. According to the sample pipeline characteristics and pipeline topography, reachable energy have been estimated; in the next step, pay attending to reachable energy, initial investment cost, total benefit of operating period, benefit to cost ratio and other economical parameters for small hydro-power plants in case study pipelines have been presented and generated power cost of the same amount via other resources compared to the hydro-power cost. At the end, in agreement with environmental advantages of small hydro-power plants, the methods of generated power utilization, proper solution for optimization of reachable energy in water transmission pipeline and substitution of pressure reducing valve by small hydro-power plant in the pipelines as a major solution for energy recovering in water pipelines have been proposed.展开更多
The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, ...The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, it would be necessary to establish a system of information management for the pipeline. The monitoring, calculating and analyzing functions of the system serve to give controlling instructions and safe operating rules to the automatic equipment and technician, making sure the resistance coefficient distribution along the pipeline is reasonable; the hydraulic state transition is smooth when operating conditions change or water supply accidents occur, avoiding the damage of water hammer. This paper covered the composition structures of the information management system of long-distance water transmission pipelines and the functions of the subsystems, and finally elaborated on the approaches and steps of building a mathematics model for the analysis of dynamic hydraulic status.展开更多
Damage caused by the 2011 Tohoku Earthquake (Mw 9.0) to transmission and distribution pipelines in Sendai City is summarized. The locations of the pipeline repairs are discussed relative to earthquake intensity, geo...Damage caused by the 2011 Tohoku Earthquake (Mw 9.0) to transmission and distribution pipelines in Sendai City is summarized. The locations of the pipeline repairs are discussed relative to earthquake intensity, geomorphologic conditions and landform change in the developed areas of hilly land. Repair rate (repairs/km) is summarized according to pipe material and presence or absence of artificial landform change. The following findings were obtained: (1) More than 80% of the repairs took place in pipelines installed in higher lands such as hill and terrace areas consisting of hard soils; (2) Nearly all the pipe repairlocations in hill areas are where landform change was made through land development tor residential purposes over me past several decades; (3) The aforementioned repair rate was more than 3.6 times than that of other lowland areas where no landform change occurred. The heaviest concentrations of pipe repairs of vinyl chloride pipes and ductile iron pipes were observed within the boundary area between cutting and filling, having a thickness between -2.5 m and 2.5 m. Approximately 78% of the all pipe repairs occurred outside of areas where severe ground failures took place. A mechanism of pipe damage in the areas free of severe ground failure was discussed.展开更多
A profound understanding of the costs to perform condition assessment on buried drinking water pipeline infrastructure is required for enhanced asset management. Toward this end, an automated and uniform method of col...A profound understanding of the costs to perform condition assessment on buried drinking water pipeline infrastructure is required for enhanced asset management. Toward this end, an automated and uniform method of collecting cost data can provide water utilities a means for viewing, understanding, interpreting and visualizing complex geographically referenced cost information to reveal data relationships, patterns and trends. However, there has been no standard data model that allows automated data collection and interoperability across platforms. The primary objective of this research is to develop a standard cost data model for drinking water pipeline condition assessment projects and to conflate disparate datasets from differing utilities. The capabilities of this model will be further demonstrated through performing trend analyses. Field mapping files will be generated from the standard data model and demonstrated in an interactive web map created using Google Maps API (application programming interface) for JavaScript that allows the user to toggle project examples and to perform regional comparisons. The aggregation of standardized data and further use in mapping applications will help in providing timely access to condition assessment cost information and resources that will lead to enhanced asset management and resource allocation for drinking water utilities.展开更多
This study explores the arrivals of water pipeline break failures. The aim is to assist the facility manager in the decision making process. Based on characteristics of the data set ranging from 2011 to 2014, two step...This study explores the arrivals of water pipeline break failures. The aim is to assist the facility manager in the decision making process. Based on characteristics of the data set ranging from 2011 to 2014, two steps of analysis were presented in the paper. This first step is the analysis of partially complete data set (2011 data). The 2-sample KS test is adopted to check the similarity between this data set and the entire data set with no underlying distribution implied. In order to conduct the reliability analysis, the Weibull distribution is adopted to evaluate the data. For annual data set, the 2-parameter Weibull distribution fits data sets pretty well. The shape parameters are a little greater than 1, indicating a slightly increasing arrival rate of such failures. For the entire data set, the 3-parameter Weibull tends to fit the data better than the 2-parameter Weibull. The shape parameter is well above 1, indicating an increasing arrival rate of the failures. To eliminate the impact of missing points for the 2011 data set, data from 2012 to 2014 were also considered as a new set, the Weibull distribution generated a decent fitting. The shape parameter is a little greater than 1. Therefore, there is a slightly increasing arrival rate of those pipeline failures. Results from this study provide decision makers valuable information in terms of whether additional efforts shall be made to enhance the system’s performance in order to reduce the failure rate.展开更多
Landslide term is used for all mass movements on slopes, including falling, overturns and flow debris. Using the potential landslide hazard zonation, areas with high potential of landslide hazard can be detected and s...Landslide term is used for all mass movements on slopes, including falling, overturns and flow debris. Using the potential landslide hazard zonation, areas with high potential of landslide hazard can be detected and so prevent the landslide occurrence with providing appropriate solutions. In this study, the landslide hazard zonation along the water transmission lines of the Amir-Almomenin (AS) water supply complex has been done. Studied area is located at the western part of the Northern Khorasan (Bojnord). Study procedure includes the general geology survey, recognition of the most important effective parameters on the landslide phenomena (such as slope, lithology, faults and streams) and has been evaluated as basic maps. Then, each layer was validated based on the importance of the effective factors using the maps weighting method in ArcGis software. Finally, the studied area was zoned based on the landslide potential using the overlapping of the various layers. Final zonation map shows that the North, Northwestern and Median parts of the studied area have the highest landslide potential. These areas are included of Marl and red Marl and to some extend loss deposits with slopes between 14 to more of 50 degrees. Seemingly, faults (due to low occurrence) and streams (due to drought) have lower effect on the landslide potential. However, the degree of the slope and type of lithology are the most important parameters on the landslide potential, respectively.展开更多
Losses due to hazards are inevitable and numerical simulations for estimations are complex.This study proposes a model for estimating correlated seismic damages and losses of a water supply pipeline system as an alter...Losses due to hazards are inevitable and numerical simulations for estimations are complex.This study proposes a model for estimating correlated seismic damages and losses of a water supply pipeline system as an alternative for numerical simulations.The common approach in other research shows average damage spots per mesh estimated statistically independent to one another.Spatially distributed lifeline systems,such as water supply pipelines,are interconnected,and seismic spatial variability affects the damages across the region;thus,spatial correlation of damage spots is an important factor in target areas for portfolio loss estimation.Generally,simulations are used to estimate possible losses;however,these assume each damage behaves independently and uncorrelated.This paper assumed that damages per mesh behave in a Poisson distribution to avoid over-dispersion and eliminate negative losses in estimations.The purpose of this study is to obtain a probabilistic portfolio loss model of an extensive water supply area.The proposed model was compared to the numerical simulation data with the correlated Poisson distribution.The application of the Normal To Anything(NORTA)obtained correlations for Poisson Distributions.The proposed probabilistic portfolio loss model,based on the generalized linear model and central limit theory,estimated the possible losses,such as the Probable Maximum Loss(PML,90%non-exceedance)or Normal Expected Loss(NEL,50%non-exceedance).The proposed model can be used in other lifeline systems as well,though additional investigation is needed for confirmation.From the estimations,a seismic physical portfolio loss for the water supply system was presented.The portfolio was made to show possible outcomes for the system.The proposed method was tested and analyzed using an artificial field and a location-based scenario of a water supply pipeline system.This would aid in pre-disaster planning and would require only a few steps and time.展开更多
A combined process was developed to inhibit the corrosion both in the pipeline of reclaimed water supplies(PRWS) and in downstream recirculating cooling water systems(RCWS)using the reclaimed water as makeup. Hydr...A combined process was developed to inhibit the corrosion both in the pipeline of reclaimed water supplies(PRWS) and in downstream recirculating cooling water systems(RCWS)using the reclaimed water as makeup. Hydroxyl carboxylate-based corrosion inhibitors(e.g.,gluconate, citrate, tartrate) and zinc sulfate heptahydrate, which provided Zn^2+ as a synergistic corrosion inhibition additive, were added prior to the PRWS when the phosphate(which could be utilized as a corrosion inhibitor) content in the reclaimed water was below 1.7 mg/L, and no additional corrosion inhibitors were required for the downstream RCWS.Satisfactory corrosion inhibition was achieved even if the RCWS was operated under the condition of high numbers of concentration cycles. The corrosion inhibition requirement was also met by the appropriate combination of PO4^3- and Zn^2+ when the phosphate content in the reclaimed water was more than 1.7 mg/L. The process integrated not only water reclamation and reuse, and the operation of a highly concentrated RCWS, but also the comprehensive utilization of phosphate in reclaimed water and the application of non-phosphorus corrosion inhibitors. The proposed process reduced the operating cost of the PRWS and the RCWS, and lowered the environmental hazard caused by the excessive discharge of phosphate. Furthermore, larger amounts of water resources could be conserved as a result.展开更多
Water supply pipelines are the lifelines of a city. When pipelines burst, the burst site is difficult to locate by traditional methods such as manual tools or only by watching. In this paper, the burst site was iden...Water supply pipelines are the lifelines of a city. When pipelines burst, the burst site is difficult to locate by traditional methods such as manual tools or only by watching. In this paper, the burst site was identified using back-propagation (BP) artificial neural networks (ANN). The study is based on an indoor urban water supply model experiment. The key to appling BP ANN is to optimize the ANN's topological structure and learning parameters. This paper presents the optimizing method for a 3-layer BP neural network's topological structure and its learning parameters-learning ratio and the momentum factor. The indoor water supply pipeline model experimental results show that BP ANNs can be used to locate the burst point in urban water supply systems. The topological structure and learning parameters were optimized using the experimental results.展开更多
基金financially supported by the National Basic Research Program of China (No. 2013CBA01803)the National Natural Science Foundation of China (No. 41101065)and the CAS "Equipment Development Project for Scientific Research" (No. YZ201523)
文摘Adopting the quasi-three-dimensional (Quasi-3D) numerical method to optimize the anti-freeze design parameters of an underground pipeline usually involves heavy numerical calculations. Here, the fitting formulae between the safe con-veyance distance (SCD) of a water pipeline and six influencing factors are established based on the lowest water temper-ature (LWT) along the pipeline axis direction. With reference to the current widely used anti-freeze design approaches for underground pipelines in seasonally frozen areas, this paper first analyzes the feasibility of applying the maximum frozen penetration (MFP) instead of the mean annual ground surface temperature (MAGST) and soil water content (SWC) to calculate the SCD. The results show that the SCD depends on the buried depth if the MFP is fixed and the variation of the MAGST and SWC combination does not significantly change the SCD. A comprehensive formula for the SCD is estab-lished based on the relationships between the SCD and several primary influencing factors and the interaction among them. This formula involves five easy-to-access parameters: the MFP, buried depth, pipeline diameter, flow velocity, and inlet water temperature. A comparison between the analytical method and the numerical results based on the Quasi-3D method indicates that the two methods are in good agreement overall. The analytic method can be used to optimize the anti-freeze design parameters of underground water pipelines in seasonally frozen areas under the condition of a 1.5 safety coefficient.
基金funded by the China National Key Research and Development Program(No.2022YFC3003505)the Fundamental Research Fund for the Central Public-interest Scientific Institutes(No.DQJB23Y01)+1 种基金the National Natural Science Foundation of China(No.52278540)the Fundamental Research Fund for the Central Public-interest Scientific Institutes(No.DQJB22B28).
文摘In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highways,railroads,and water supply pipelines,was particularly severe in areas where these structures intersected the seismogenic fault.Critical infrastructure projects that traverse active faults are susceptible to the influence of fault movement,pulse velocity,and ground motions.In this study,we used a unique approach to analyze the acceleration records obtained from the seismic station array(9 strong ground motion stations)located along the East Anatolian Fault(the seismogenic fault of the MW7.8 mainshock of the 2023 Türkiye earthquake doublet).The acceleration records were filtered and integrated to obtain the velocity and displacement time histories.We used the results of an on-site investigation,jointly conducted by China Earthquake Administration and Türkiye’s AFAD,to analyze the distribution of PGA,PGV,and PGD recorded by the strong motion array of the East Anatolian Fault.We found that the maximum horizontal PGA in this earthquake was 3.0 g,and the maximum co-seismic surface displacement caused by the East Anatolian Fault rupture was 6.50 m.As the fault rupture propagated southwest,the velocity pulse caused by the directional effect of the rupture increased gradually,with the maximum PGA reaching 162.3 cm/s.We also discussed the seismic safety of critical infrastructure projects traversing active faults,using two case studies of water supply pipelines in Türkiye that were damaged by earthquakes.We used a three-dimensional finite element model of the PE(polyethylene)water pipeline at the Islahiye State Hospital and fault displacement observations obtained through on-site investigation to analyze pipeline failure mechanisms.We further investigated the effect of the fault-crossing angle on seismic safety of a pipeline,based on our analysis and the failure performance of the large-diameter Thames Water pipeline during the 1999 Kocaeli earthquake.The seismic method of buried pipelines crossing the fault was summarized.
基金supported by the three funds:Industry-University-research Project of Anhui Jianzhu University HYB20210116National Key Research and Development Project of China No.2017YFC0704100(entitled New Generation Intelligent Building Platform Techniques)Research Project of Anhui Jianzhu University jy2021-c-017(Project Name:Research and Application ofWater Distribution Network Leakage Detection System Based on DMA Partition).
文摘At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of pipeline leakage is of great significance for saving water resources and reducing economic losses.Acoustic emission technology is the most widely used pipeline leak location technology.The traditional non-stationary random signal de-noising method mainly relies on the estimation of noise parameters,ignoring periodic noise and components unrelated to pipeline leakage.Aiming at the above problems,this paper proposes a leak location method for water supply pipelines based on a multivariate variational mode decomposition algorithm.This method combines the two parameters of the energy loss coefficient and the correlation coefficient between adjacent modes,and adaptively determines the decomposition mode number K according to the characteristics of the signal itself.According to the correlation coefficient,the effective component is selected to reconstruct the signal and the cross-correlation time delay is estimated to determine the location of the pipeline leakage point.The experimental results show that this method has higher accuracy than the cross-correlation method based on VMD and the cross-correlation method based on EMD,and the average relative positioning error is less than 2.2%.
文摘In this work, historical background of power generation by small hydro-power plants across the world and specially across the Iran with emphasis on small hydro-power plant utilization as recovery turbine in water transmission pipeline have been attended firstly, and then, three water transmission pipelines from Chah-nemie to Zahedan city, Shirindare dam to Bojnord city and Mokhtaran desert to Birjand city in Iran have been studied as case study samples. According to the sample pipeline characteristics and pipeline topography, reachable energy have been estimated; in the next step, pay attending to reachable energy, initial investment cost, total benefit of operating period, benefit to cost ratio and other economical parameters for small hydro-power plants in case study pipelines have been presented and generated power cost of the same amount via other resources compared to the hydro-power cost. At the end, in agreement with environmental advantages of small hydro-power plants, the methods of generated power utilization, proper solution for optimization of reachable energy in water transmission pipeline and substitution of pressure reducing valve by small hydro-power plant in the pipelines as a major solution for energy recovering in water pipelines have been proposed.
基金Hi-Tech Research and Development Program of China (863 Program)(2002AA601140)
文摘The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, it would be necessary to establish a system of information management for the pipeline. The monitoring, calculating and analyzing functions of the system serve to give controlling instructions and safe operating rules to the automatic equipment and technician, making sure the resistance coefficient distribution along the pipeline is reasonable; the hydraulic state transition is smooth when operating conditions change or water supply accidents occur, avoiding the damage of water hammer. This paper covered the composition structures of the information management system of long-distance water transmission pipelines and the functions of the subsystems, and finally elaborated on the approaches and steps of building a mathematics model for the analysis of dynamic hydraulic status.
文摘Damage caused by the 2011 Tohoku Earthquake (Mw 9.0) to transmission and distribution pipelines in Sendai City is summarized. The locations of the pipeline repairs are discussed relative to earthquake intensity, geomorphologic conditions and landform change in the developed areas of hilly land. Repair rate (repairs/km) is summarized according to pipe material and presence or absence of artificial landform change. The following findings were obtained: (1) More than 80% of the repairs took place in pipelines installed in higher lands such as hill and terrace areas consisting of hard soils; (2) Nearly all the pipe repairlocations in hill areas are where landform change was made through land development tor residential purposes over me past several decades; (3) The aforementioned repair rate was more than 3.6 times than that of other lowland areas where no landform change occurred. The heaviest concentrations of pipe repairs of vinyl chloride pipes and ductile iron pipes were observed within the boundary area between cutting and filling, having a thickness between -2.5 m and 2.5 m. Approximately 78% of the all pipe repairs occurred outside of areas where severe ground failures took place. A mechanism of pipe damage in the areas free of severe ground failure was discussed.
文摘A profound understanding of the costs to perform condition assessment on buried drinking water pipeline infrastructure is required for enhanced asset management. Toward this end, an automated and uniform method of collecting cost data can provide water utilities a means for viewing, understanding, interpreting and visualizing complex geographically referenced cost information to reveal data relationships, patterns and trends. However, there has been no standard data model that allows automated data collection and interoperability across platforms. The primary objective of this research is to develop a standard cost data model for drinking water pipeline condition assessment projects and to conflate disparate datasets from differing utilities. The capabilities of this model will be further demonstrated through performing trend analyses. Field mapping files will be generated from the standard data model and demonstrated in an interactive web map created using Google Maps API (application programming interface) for JavaScript that allows the user to toggle project examples and to perform regional comparisons. The aggregation of standardized data and further use in mapping applications will help in providing timely access to condition assessment cost information and resources that will lead to enhanced asset management and resource allocation for drinking water utilities.
文摘This study explores the arrivals of water pipeline break failures. The aim is to assist the facility manager in the decision making process. Based on characteristics of the data set ranging from 2011 to 2014, two steps of analysis were presented in the paper. This first step is the analysis of partially complete data set (2011 data). The 2-sample KS test is adopted to check the similarity between this data set and the entire data set with no underlying distribution implied. In order to conduct the reliability analysis, the Weibull distribution is adopted to evaluate the data. For annual data set, the 2-parameter Weibull distribution fits data sets pretty well. The shape parameters are a little greater than 1, indicating a slightly increasing arrival rate of such failures. For the entire data set, the 3-parameter Weibull tends to fit the data better than the 2-parameter Weibull. The shape parameter is well above 1, indicating an increasing arrival rate of the failures. To eliminate the impact of missing points for the 2011 data set, data from 2012 to 2014 were also considered as a new set, the Weibull distribution generated a decent fitting. The shape parameter is a little greater than 1. Therefore, there is a slightly increasing arrival rate of those pipeline failures. Results from this study provide decision makers valuable information in terms of whether additional efforts shall be made to enhance the system’s performance in order to reduce the failure rate.
文摘Landslide term is used for all mass movements on slopes, including falling, overturns and flow debris. Using the potential landslide hazard zonation, areas with high potential of landslide hazard can be detected and so prevent the landslide occurrence with providing appropriate solutions. In this study, the landslide hazard zonation along the water transmission lines of the Amir-Almomenin (AS) water supply complex has been done. Studied area is located at the western part of the Northern Khorasan (Bojnord). Study procedure includes the general geology survey, recognition of the most important effective parameters on the landslide phenomena (such as slope, lithology, faults and streams) and has been evaluated as basic maps. Then, each layer was validated based on the importance of the effective factors using the maps weighting method in ArcGis software. Finally, the studied area was zoned based on the landslide potential using the overlapping of the various layers. Final zonation map shows that the North, Northwestern and Median parts of the studied area have the highest landslide potential. These areas are included of Marl and red Marl and to some extend loss deposits with slopes between 14 to more of 50 degrees. Seemingly, faults (due to low occurrence) and streams (due to drought) have lower effect on the landslide potential. However, the degree of the slope and type of lithology are the most important parameters on the landslide potential, respectively.
文摘Losses due to hazards are inevitable and numerical simulations for estimations are complex.This study proposes a model for estimating correlated seismic damages and losses of a water supply pipeline system as an alternative for numerical simulations.The common approach in other research shows average damage spots per mesh estimated statistically independent to one another.Spatially distributed lifeline systems,such as water supply pipelines,are interconnected,and seismic spatial variability affects the damages across the region;thus,spatial correlation of damage spots is an important factor in target areas for portfolio loss estimation.Generally,simulations are used to estimate possible losses;however,these assume each damage behaves independently and uncorrelated.This paper assumed that damages per mesh behave in a Poisson distribution to avoid over-dispersion and eliminate negative losses in estimations.The purpose of this study is to obtain a probabilistic portfolio loss model of an extensive water supply area.The proposed model was compared to the numerical simulation data with the correlated Poisson distribution.The application of the Normal To Anything(NORTA)obtained correlations for Poisson Distributions.The proposed probabilistic portfolio loss model,based on the generalized linear model and central limit theory,estimated the possible losses,such as the Probable Maximum Loss(PML,90%non-exceedance)or Normal Expected Loss(NEL,50%non-exceedance).The proposed model can be used in other lifeline systems as well,though additional investigation is needed for confirmation.From the estimations,a seismic physical portfolio loss for the water supply system was presented.The portfolio was made to show possible outcomes for the system.The proposed method was tested and analyzed using an artificial field and a location-based scenario of a water supply pipeline system.This would aid in pre-disaster planning and would require only a few steps and time.
基金supported by the Key Laboratory of Drinking Water Science and Technology, Chinese Academy of Sciences (No. 15Z01KLDWST)the National Natural Science Foundation of China (Nos. 51378491 and 51578533)
文摘A combined process was developed to inhibit the corrosion both in the pipeline of reclaimed water supplies(PRWS) and in downstream recirculating cooling water systems(RCWS)using the reclaimed water as makeup. Hydroxyl carboxylate-based corrosion inhibitors(e.g.,gluconate, citrate, tartrate) and zinc sulfate heptahydrate, which provided Zn^2+ as a synergistic corrosion inhibition additive, were added prior to the PRWS when the phosphate(which could be utilized as a corrosion inhibitor) content in the reclaimed water was below 1.7 mg/L, and no additional corrosion inhibitors were required for the downstream RCWS.Satisfactory corrosion inhibition was achieved even if the RCWS was operated under the condition of high numbers of concentration cycles. The corrosion inhibition requirement was also met by the appropriate combination of PO4^3- and Zn^2+ when the phosphate content in the reclaimed water was more than 1.7 mg/L. The process integrated not only water reclamation and reuse, and the operation of a highly concentrated RCWS, but also the comprehensive utilization of phosphate in reclaimed water and the application of non-phosphorus corrosion inhibitors. The proposed process reduced the operating cost of the PRWS and the RCWS, and lowered the environmental hazard caused by the excessive discharge of phosphate. Furthermore, larger amounts of water resources could be conserved as a result.
文摘Water supply pipelines are the lifelines of a city. When pipelines burst, the burst site is difficult to locate by traditional methods such as manual tools or only by watching. In this paper, the burst site was identified using back-propagation (BP) artificial neural networks (ANN). The study is based on an indoor urban water supply model experiment. The key to appling BP ANN is to optimize the ANN's topological structure and learning parameters. This paper presents the optimizing method for a 3-layer BP neural network's topological structure and its learning parameters-learning ratio and the momentum factor. The indoor water supply pipeline model experimental results show that BP ANNs can be used to locate the burst point in urban water supply systems. The topological structure and learning parameters were optimized using the experimental results.