In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed...In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.展开更多
To investigate the effects of silver nanoparticles(Ag NPs)and low temperature double-pressure on the wastewater treatment efficacy and the microbial community structure of constructed wetlands,a pilot-scale vertical f...To investigate the effects of silver nanoparticles(Ag NPs)and low temperature double-pressure on the wastewater treatment efficacy and the microbial community structure of constructed wetlands,a pilot-scale vertical flow constructed wetland was set up to treat synthetic wastewater under laboratory conditions.By measuring the effluent concentration of ammonia nitrogen(NH_(4)^(+)-N),total nitrogen(TN),total phosphorus(TP),chemical oxygen demand(COD),and the diversity,richness,and community structure of microorganisms of the upper and lower soil layers in the wetland,the nutrient removal effect of the constructed wetland and the changes in the microflora of the soil layer were studied.The results reveal that the correlation coefficients between the removal rates of TN and NH_(4)^(+)-N and the temperature are 0.463 and 0.692,respectively,indicating a significant positive correlation.From the warm to the cold season,both the diversity and richness of microorganisms in the lower soil layer of wetlands are inhibited under the double-pressure of Ag NPs and low temperature,and the abundances of the denitrogenation functional bacteria such as Candidatus nitrososphaera,Sulfuritalea,Anaeromyxobacter,Candidatus solibacter,Nitrospira,and Zoogloea are altered.Low temperature and Ag NPs exposure can thus affect the wastewater treatment performance of constructed wetlands,possibly because of the seasonal changes of the microflora.展开更多
A Natural Ecological Wastewater Treatment System (NEWTS) is usually built on natural terrain with necessary topography modification to improve water flowing route and pattern, and then the topography modified NEWTS ...A Natural Ecological Wastewater Treatment System (NEWTS) is usually built on natural terrain with necessary topography modification to improve water flowing route and pattern, and then the topography modified NEWTS should also have a reasonable water storage volume and hydraulic retention time so as to achieve the anticipated water purification effect. In this study, the dynamic mesh technique based on the finite element method and element storativity coefficients was presented to develop a two-dimensional hydrodynamic and water quality model, which was used to optimize the design of NEWTS under the dynamic land-water boundary due to various water storage volume. The models were employed in the optimized design of NEWTS from a large abandoned coal mine, which purifies the polluted water flowing into a large water storage lake, as part of the East Route South-to-North Water Transfer Project in China. Specifically, the natural topography modification scheme was presented, and further, a reasonable water storage volume and hydraulic residence time was obtained, based on the reasonable estimation of roughness coefficient and pollutant removal rate of the NEWTS with phragmites communis.展开更多
Efficiently predicting effluent quality through data-driven analysis presents a significant advancement for consistent wastewater treatment operations.In this study,we aimed to develop an integrated method for predict...Efficiently predicting effluent quality through data-driven analysis presents a significant advancement for consistent wastewater treatment operations.In this study,we aimed to develop an integrated method for predicting effluent COD and NH3 levels.We employed a 200 L pilot-scale sequencing batch reactor(SBR)to gather multimodal data from urban sewage over 40 d.Then we collected data on critical parameters like COD,DO,pH,NH_(3),EC,ORP,SS,and water temperature,alongside wastewater surface images,resulting in a data set of approximately 40246 points.Then we proposed a brain-inspired image and temporal fusion model integrated with a CNN-LSTM network(BITF-CL)using this data.This innovative model synergized sewage imagery with water quality data,enhancing prediction accuracy.As a result,the BITF-CL model reduced prediction error by over 23%compared to traditional methods and still performed comparably to conventional techniques even without using DO and SS sensor data.Consequently,this research presents a cost-effective and precise prediction system for sewage treatment,demonstrating the potential of brain-inspired models.展开更多
A water quality model for water reuse was made by mathematics induction. The relationship among the reuse rate of treated wastewater(R), pollutant concentration of reused water( Cs ), pollutant concentration of in...A water quality model for water reuse was made by mathematics induction. The relationship among the reuse rate of treated wastewater(R), pollutant concentration of reused water( Cs ), pollutant concentration of influent( C0), removal efficiency of pollutant in wastewater( E), and the standard of reuse water were discussed in this study. According to the experiment result of a toilet wastewater treatment and reuse with membrane bioreactors, R would be set at less than 40%, on which all the concerned parameters could meet with the reuse water standards. To raise R of reuse water in the toilet, an important way was to improve color removal of the wastewater.展开更多
针对污水处理厂生化池中参数监测智能化水平不高、人力耗费较大的问题,提出基于麻雀算法-长短期记忆神经网络(Sparrow Search Algorithm-Long Short Term Memory Network,SSA-LSTM)的水质参数预测模型。以污水处理过程中好氧区溶解氧(Di...针对污水处理厂生化池中参数监测智能化水平不高、人力耗费较大的问题,提出基于麻雀算法-长短期记忆神经网络(Sparrow Search Algorithm-Long Short Term Memory Network,SSA-LSTM)的水质参数预测模型。以污水处理过程中好氧区溶解氧(Dissolved Oxygen,DO)、好氧区混合液悬浮固体(Mixed Liquid Suspended Solids,MLSS)质量浓度、缺氧区DO、缺氧区氧化还原电位(Oxidation-Reduction Potential,ORP)、厌氧区DO和厌氧区ORP 6个关键指标为数据样本,进行实例研究。将SSA-LSTM的预测结果与长短期记忆神经网络(Long Short-Term Memory Network,LSTM)、粒子群算法(Particle Swarm optimization-Long Short Term Memory Network,PSO-LSTM)、深度森林以及支持向量机进行对比分析,结果显示:SSA-LSTM在6个参数上的均方误差(EMSE)和决定系数(R2)均表现出更好的预测性,预测精度最高。展开更多
文摘In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.
基金The National Natural Science Foundation of China(No.50909019,51479034)the Fundamental Research Funds for the Central Universities(No.2242019K40064)。
文摘To investigate the effects of silver nanoparticles(Ag NPs)and low temperature double-pressure on the wastewater treatment efficacy and the microbial community structure of constructed wetlands,a pilot-scale vertical flow constructed wetland was set up to treat synthetic wastewater under laboratory conditions.By measuring the effluent concentration of ammonia nitrogen(NH_(4)^(+)-N),total nitrogen(TN),total phosphorus(TP),chemical oxygen demand(COD),and the diversity,richness,and community structure of microorganisms of the upper and lower soil layers in the wetland,the nutrient removal effect of the constructed wetland and the changes in the microflora of the soil layer were studied.The results reveal that the correlation coefficients between the removal rates of TN and NH_(4)^(+)-N and the temperature are 0.463 and 0.692,respectively,indicating a significant positive correlation.From the warm to the cold season,both the diversity and richness of microorganisms in the lower soil layer of wetlands are inhibited under the double-pressure of Ag NPs and low temperature,and the abundances of the denitrogenation functional bacteria such as Candidatus nitrososphaera,Sulfuritalea,Anaeromyxobacter,Candidatus solibacter,Nitrospira,and Zoogloea are altered.Low temperature and Ag NPs exposure can thus affect the wastewater treatment performance of constructed wetlands,possibly because of the seasonal changes of the microflora.
基金supported by the Key Program on the S and T for the Pollution Control and Treatment of Water Bodies (Grant Nos.2009ZX07210-008,2009ZX07316-005)the Science and Technology Commission of Shanghai Municipal People's Government (Grant No.072312050)
文摘A Natural Ecological Wastewater Treatment System (NEWTS) is usually built on natural terrain with necessary topography modification to improve water flowing route and pattern, and then the topography modified NEWTS should also have a reasonable water storage volume and hydraulic retention time so as to achieve the anticipated water purification effect. In this study, the dynamic mesh technique based on the finite element method and element storativity coefficients was presented to develop a two-dimensional hydrodynamic and water quality model, which was used to optimize the design of NEWTS under the dynamic land-water boundary due to various water storage volume. The models were employed in the optimized design of NEWTS from a large abandoned coal mine, which purifies the polluted water flowing into a large water storage lake, as part of the East Route South-to-North Water Transfer Project in China. Specifically, the natural topography modification scheme was presented, and further, a reasonable water storage volume and hydraulic residence time was obtained, based on the reasonable estimation of roughness coefficient and pollutant removal rate of the NEWTS with phragmites communis.
基金supported by the National Key R&D Program of China(No.2021YFC1809001).
文摘Efficiently predicting effluent quality through data-driven analysis presents a significant advancement for consistent wastewater treatment operations.In this study,we aimed to develop an integrated method for predicting effluent COD and NH3 levels.We employed a 200 L pilot-scale sequencing batch reactor(SBR)to gather multimodal data from urban sewage over 40 d.Then we collected data on critical parameters like COD,DO,pH,NH_(3),EC,ORP,SS,and water temperature,alongside wastewater surface images,resulting in a data set of approximately 40246 points.Then we proposed a brain-inspired image and temporal fusion model integrated with a CNN-LSTM network(BITF-CL)using this data.This innovative model synergized sewage imagery with water quality data,enhancing prediction accuracy.As a result,the BITF-CL model reduced prediction error by over 23%compared to traditional methods and still performed comparably to conventional techniques even without using DO and SS sensor data.Consequently,this research presents a cost-effective and precise prediction system for sewage treatment,demonstrating the potential of brain-inspired models.
基金The Hi_Tech Research and Development Program(863) of China(No:2002AA601220)
文摘A water quality model for water reuse was made by mathematics induction. The relationship among the reuse rate of treated wastewater(R), pollutant concentration of reused water( Cs ), pollutant concentration of influent( C0), removal efficiency of pollutant in wastewater( E), and the standard of reuse water were discussed in this study. According to the experiment result of a toilet wastewater treatment and reuse with membrane bioreactors, R would be set at less than 40%, on which all the concerned parameters could meet with the reuse water standards. To raise R of reuse water in the toilet, an important way was to improve color removal of the wastewater.