A solid ternary mixture consisting of NaF, silicon and one of the metal oxides such as Al2O3, MgO, CaO, SrO, BaO was prepared and used as a defluorinated reagent for CF4 decomposition. The results show that the initia...A solid ternary mixture consisting of NaF, silicon and one of the metal oxides such as Al2O3, MgO, CaO, SrO, BaO was prepared and used as a defluorinated reagent for CF4 decomposition. The results show that the initial conversion of CF4 reached 100% over NaF-Si-MgO and NaF-Si-CaO at 850°C, and the reagent with NaF/Si/MgO molar ratio of 33/34/33 exhibited a high reactivity with a full conversion of CF4 lasting for 57 min. The plausible paths of CF4 decomposition over NaF-Si-Al2O3, NaF-Si-MgO, NaF-Si-CaO, NaF-Si-SrO and NaF-Si-BaO are proposed.展开更多
Nessler's reagent spectrophotometry,gas phase molecular absorption spectrometry and ion chromatography were respectively used to determine ammonia nitrogen in surface water.The detection limit,precision,accuracy a...Nessler's reagent spectrophotometry,gas phase molecular absorption spectrometry and ion chromatography were respectively used to determine ammonia nitrogen in surface water.The detection limit,precision,accuracy and recovery rate of the three methods were compared,and the determination results of the actual water samples were analyzed by t test.The results showed that the three methods all could meet the requirement of the laboratory quality control,and there was no significant difference in the determination results.Compared with Nessler's reagent spectrophotometry,the operation of gas phase molecular absorption spectrometry and ion chromatography operation was more convenient and fast and has no pollution,which can be used for the determination of ammonia nitrogen content in a large quantity of surface water samples.展开更多
The heteroligand complex of manganese with 1,10-phenantroline and o-nitrobenzolazosalicylic acid has been investigated by spectrophotometric method. The condition of complexing and extraction, physical-chemical and an...The heteroligand complex of manganese with 1,10-phenantroline and o-nitrobenzolazosalicylic acid has been investigated by spectrophotometric method. The condition of complexing and extraction, physical-chemical and analytical characteristics of this complex have been found. Complex formation is observed in the pH range 5 - 11. Extraction constant was found as 5.3 × 1012, stability constant was found as lgβK = 9.03?± 0.03. Molar absorptivity is ε = (1.36 ± 0.08) × 104 l·g﹣1·cm﹣1. Beer's law is obeyed in the range of 1.0 - 22.5 μkg manganese (II). The extraction-photometric methods of manganese determination have been worked out. The influence of diverse ions on determination of manganese (II) has been studied. The proposed method was applied successfully to determine amount of manganese in tap water.展开更多
基金financially supported by the National Natural Science Foundation of China(No.20976149)
文摘A solid ternary mixture consisting of NaF, silicon and one of the metal oxides such as Al2O3, MgO, CaO, SrO, BaO was prepared and used as a defluorinated reagent for CF4 decomposition. The results show that the initial conversion of CF4 reached 100% over NaF-Si-MgO and NaF-Si-CaO at 850°C, and the reagent with NaF/Si/MgO molar ratio of 33/34/33 exhibited a high reactivity with a full conversion of CF4 lasting for 57 min. The plausible paths of CF4 decomposition over NaF-Si-Al2O3, NaF-Si-MgO, NaF-Si-CaO, NaF-Si-SrO and NaF-Si-BaO are proposed.
文摘Nessler's reagent spectrophotometry,gas phase molecular absorption spectrometry and ion chromatography were respectively used to determine ammonia nitrogen in surface water.The detection limit,precision,accuracy and recovery rate of the three methods were compared,and the determination results of the actual water samples were analyzed by t test.The results showed that the three methods all could meet the requirement of the laboratory quality control,and there was no significant difference in the determination results.Compared with Nessler's reagent spectrophotometry,the operation of gas phase molecular absorption spectrometry and ion chromatography operation was more convenient and fast and has no pollution,which can be used for the determination of ammonia nitrogen content in a large quantity of surface water samples.
文摘The heteroligand complex of manganese with 1,10-phenantroline and o-nitrobenzolazosalicylic acid has been investigated by spectrophotometric method. The condition of complexing and extraction, physical-chemical and analytical characteristics of this complex have been found. Complex formation is observed in the pH range 5 - 11. Extraction constant was found as 5.3 × 1012, stability constant was found as lgβK = 9.03?± 0.03. Molar absorptivity is ε = (1.36 ± 0.08) × 104 l·g﹣1·cm﹣1. Beer's law is obeyed in the range of 1.0 - 22.5 μkg manganese (II). The extraction-photometric methods of manganese determination have been worked out. The influence of diverse ions on determination of manganese (II) has been studied. The proposed method was applied successfully to determine amount of manganese in tap water.