The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the ded...The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the dedicated outdoor air system(DOAS) and indoor thermal comfort can be enhanced by the radiant cooling system(RCS). The optimal air-supply mode of the hybrid system and the corresponding design approach were investigated. A full-scale experimental chamber with various air outlets and the ceiling radiant cooling panels(CRCP) was designed and established. The performances of different air-supply modes along with CRCPs were analyzed by multi-index evaluations. Preliminary investigations were also conducted on the humidity stratification and the control effect of different airflow modes to prevent condensation on CRCP. The overhead supply air is recommended as the best combination mode for the hybrid system after comprehensive comparison of the experiment results. The optimal proportion of CRCP accounting for the total cooling capacities in accord with specific cooling loads is found, which may provide valuable reference for the design and operation of the hybrid system.展开更多
The industrial trials of two cooling modes, i e, water cooling in forepart + air cooling in later part (WAC) and air cooling in forepart + water cooling in later part (AWC), were carried out for a Ti- Nb microalloyed ...The industrial trials of two cooling modes, i e, water cooling in forepart + air cooling in later part (WAC) and air cooling in forepart + water cooling in later part (AWC), were carried out for a Ti- Nb microalloyed steel. The average cooling rates and coiling temperature were the same for two modes. The continuous cooling transformation (CCT) curve of the tested steel was drawn. The effects of the cooling mode on the microstructure, precipitates, and properties of the steels were investigated. Results show that the strength of the steel in the WAC mode is significantly larger than that in the AWC mode, mainly because the smaller the grain size, the more and finer the grain precipitates. Therefore, when the average cooling rate is constant, the fast cooling in the forepart is an effective method to increase the strength of steels. However, the increase in the strength is accompanied by the decrease in toughness, so that the toughness of the steel should be considered when changing the cooling mode.展开更多
Optomechanical dynamics in two systems which are a transmission line resonator and Fabrya-Perot optical cavity via radiation-pressure are investigated by linearized quantum Langevin equation. We work in the resolved s...Optomechanical dynamics in two systems which are a transmission line resonator and Fabrya-Perot optical cavity via radiation-pressure are investigated by linearized quantum Langevin equation. We work in the resolved sideband regime where the oscillator resonance frequency exceeds the cavity linewidth. Normal mode splittings of the mechanical resonator as a pure result of the coupling interaction in the two optomechanical systems is studied, and we make a comparison of normal mode splitting of mechanical resonator between the two systems. In the optical cavity, the normal mode splitting of the movable mirror approaches the latest experiment very well. In addition, an approximation scheme is introduced to demonstrate the ground state cooling, and we make a comparison of cooling between the two systems dominated by two key factors, which are the initial bath temperature and the mechanical quality factor. Since both the normal mode splitting and cooling require working in the resolved sideband regime, whether the normal mode splitting influences the cooling of the mirror is considered. Considering the size of the mechanical resonator and precooling the system, the mechanical resonator in the transmission line resonator system is easier to achieve the ground state cooling than in optical cavity.展开更多
The instability of the Mack mode is destabilized by wall-cooling in a high speed boundary layer. The aim of this paper is to study the mechanism of the wall cooling effect on the Mack mode instability by numerical met...The instability of the Mack mode is destabilized by wall-cooling in a high speed boundary layer. The aim of this paper is to study the mechanism of the wall cooling effect on the Mack mode instability by numerical methods. It is shown that the wall-cooling can destabilize the Mack mode instability, similar to the previous conclusions with the exception that the Mack mode instability can be stabilized by wall-cooling if the wall temperature is extremely low. The reversed wall temperature is related to a freestream condition. If the Mach number increases to a large enough value, e.g., about 7, the reversed wall temperature will tend to be zero. It seems that the Mack mode instability is determined by the region between the boundary layer edge and the critical layer. When the wall temperature decreases, this region becomes wider, and the boundary layer becomes more unstable. Additionally, a relative supersonic unstable mode can be observed when the velocity of the critical layer is less than 1 - liMa or is cancelled by the wall-cooling effect. These results provide a deeper understanding on the wall-cooling effect in high speed boundary layers.展开更多
An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and ...An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and L3. The influence rule of different factors on the cooling effect and thermal stress of the plate were studied, for which the influence rank was respectively R 〉 L1 〉 L3 and L3 〉 R 〉 L1. The highest temperature value decreased when R and L1 increased~ and the maximum thermal stress value dropped when R, L1 and L3 increased. The final optimized results can be summarized as: R equals 6 mm or 7 mm, L1 equals 19 mm, and L3 equals 20 mm. Compared with the initial design, the highest temperature value had a small decline~ and the maximum thermal stress value dropped by 19~ to 24~. So it was not ideal to improve the cooling effect by optimizing the geometry sizes of the water-cooled structure, even worse than increasing the flow speed, but it was very effective for dropping the maximum thermal stress value. The orthogoaal experimental method reduces the number of experiments by 80%, and thus it is feasible and effective to optimize the water-cooled structure of the divertor plate with the orthogonal theory.展开更多
LiFePO4 was prepared by heating the pre-decomposed precursor mixtures sealed in vacuum quartz-tube. Three kinds of cooling modes including nature cooling, air quenching, and water quenching were applied to comparing t...LiFePO4 was prepared by heating the pre-decomposed precursor mixtures sealed in vacuum quartz-tube. Three kinds of cooling modes including nature cooling, air quenching, and water quenching were applied to comparing the effects of cooling modes on the microstructure and electrochemical characteristics of the material. The results indicate that the water quenching mode can control overgrowth of the grain size of final product and improve its electrochemical performance compared with nature cooling mode and air quenching mode. The sample synthesized by using water quenching mode is of the highest reversible discharge specific capacity and the best cyclic electrochemical performance, demonstrating the first discharge capacity of 138.1 mA·h/g at 0.1C rate and the total loss of capacity of 3.11% after 20 cycles.展开更多
The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by...The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced.展开更多
The microstructure and tensile properties of Sn-9Zn solder under different cooling and aging condition were studied. During solidification,the distribution of Zn-rich phases and grain size in the microstructure of Sn-...The microstructure and tensile properties of Sn-9Zn solder under different cooling and aging condition were studied. During solidification,the distribution of Zn-rich phases and grain size in the microstructure of Sn-9Zn solder were decided by the cooling rate. The Zn-rich phase in Sn-9Zn solder under furnace cooling,air cooling and water cooling media was separately existed as coarsen dendritic and needle like shape,fine needle like shape and very fine rod-like shape,respectively. After aging,the coarsen dendritic was broken and the coarsen needle like Zn-rich phase was partly changed into fine distribution of Zn-rich phase for Sn-9Zn solder with furnace cooling,and the rod-like Zn phase in the Sn-9Zn solder under water cooling was changed to conglomerated Zn with needle shape. During tensile testing on Sn-9Zn solder,tensile strength and ductility reached the best with water cooling,but decreased with aging effect. Meanwhile,the ductility of solder with air cooling and the strength of solder with furnace cooling increased with aging. The fracture mode was ductile and was independent of cooling media and aging effect. The size and depth of dimples decreased from water,furnace to air cooling.After aging,number and size of dimples increased on the solder with furnace cooling and air cooling. The change on the size of dimples for the Sn-9Zn solder under different cooling condition and with aging effect was accordance to the tensile properties.展开更多
Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind...Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind power generation and other fields. This paper introduces the basic structure of hybrid excitation motor with modular stator, and analyzes the operation principle of hybrid excitation motor. The cooling structure of the water-cooled plate is designed, and the effects of the thickness of the water-cooled plate and the number of water channels in the water-cooled plate on the heat dissipation capacity of the water-cooled plate are analyzed by theoretical and computational fluid dynamics methods. The effects of different water cooling plate structures on water velocity, pressure drop, water pump power consumption and heat dissipation capacity were compared and analyzed. The influence of different inlet flow velocity on the maximum temperature rise of each part of the motor is analyzed, and the temperature of each part of the motor under the optimal water flow is analyzed. The influence of the traditional spiral water jacket cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of the motor components is compared and analyzed. The results show that the water-cooled plate cooling structure is more suitable for the modular stator motor studied in this paper. Based on the water-cooled plate cooling structure, the air-water composite cooling structure is designed, and the effects of the air-water composite cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of each component of the motor are compared and analyzed. The results show that the maximum temperature rise of each component of the motor is reduced under the air-water composite cooling structure.展开更多
With the stability analysis of hyperbolic cooling tower shells with ring-stiffeners. our paper proposes the linear pre-buckling consistent theory. The numerical result shows that this linear analysis method is very ef...With the stability analysis of hyperbolic cooling tower shells with ring-stiffeners. our paper proposes the linear pre-buckling consistent theory. The numerical result shows that this linear analysis method is very effective and practical in engineering, for its precision of compulation is up to the level of the nonlinear analysis when it is used for the study of critical loads of the hyperbolic cooling tower which is mainly governed by wind pressure and for the study of the effect of some oilier factors concerned in design on the buckling of shells. Based on that, we have obtained a scries of conclusions whicii will greatly benefits the engineering design when discussing the effect on the critical windloading of the shell which is caused by the following factors such as the position of rings, the number of rings and the dead weight.展开更多
针对强迫导向油循环风冷(oir directrd air forced,ODAF)结构变压器负荷能力受温升约束影响的问题,提出了3种负荷类型情况下变压器负荷能力评估方法。首先,考虑风扇与油泵的运行状态以及油粘度变化对热阻的影响等因素,基于热电类比法建...针对强迫导向油循环风冷(oir directrd air forced,ODAF)结构变压器负荷能力受温升约束影响的问题,提出了3种负荷类型情况下变压器负荷能力评估方法。首先,考虑风扇与油泵的运行状态以及油粘度变化对热阻的影响等因素,基于热电类比法建立了变压器热路模型,以计算绕组热点与顶部油温度;其次,采用粒子群优化(particle swarm optimization,PSO)算法拟合热路模型参数,并基于2台不同型号变压器的运行数据,对热路模型的计算精度与拟合参数适用性进行有效性验证;最后,参考GB/T1094.7负载导则给出的温升限值,基于温升特性提出了负荷能力评估模型。分析结果表明,该研究所提热路模型计算热点温度的误差不大于2.35℃,在工程允许范围内;正常周期性负荷下当环境温度低于1℃时,关闭1组子散热器后仍满足温升约束。展开更多
基金Project(51178298)supported by the National Natural Science Foundation of China
文摘The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the dedicated outdoor air system(DOAS) and indoor thermal comfort can be enhanced by the radiant cooling system(RCS). The optimal air-supply mode of the hybrid system and the corresponding design approach were investigated. A full-scale experimental chamber with various air outlets and the ceiling radiant cooling panels(CRCP) was designed and established. The performances of different air-supply modes along with CRCPs were analyzed by multi-index evaluations. Preliminary investigations were also conducted on the humidity stratification and the control effect of different airflow modes to prevent condensation on CRCP. The overhead supply air is recommended as the best combination mode for the hybrid system after comprehensive comparison of the experiment results. The optimal proportion of CRCP accounting for the total cooling capacities in accord with specific cooling loads is found, which may provide valuable reference for the design and operation of the hybrid system.
基金Funded by the National Natural Science Foundation of China(No.51274154)the National High-tech Research and Development Program of China(863 Program)(No.2012AA03A504)Research and Development Center of Wuhan Iron and Steel(Group)Corp
文摘The industrial trials of two cooling modes, i e, water cooling in forepart + air cooling in later part (WAC) and air cooling in forepart + water cooling in later part (AWC), were carried out for a Ti- Nb microalloyed steel. The average cooling rates and coiling temperature were the same for two modes. The continuous cooling transformation (CCT) curve of the tested steel was drawn. The effects of the cooling mode on the microstructure, precipitates, and properties of the steels were investigated. Results show that the strength of the steel in the WAC mode is significantly larger than that in the AWC mode, mainly because the smaller the grain size, the more and finer the grain precipitates. Therefore, when the average cooling rate is constant, the fast cooling in the forepart is an effective method to increase the strength of steels. However, the increase in the strength is accompanied by the decrease in toughness, so that the toughness of the steel should be considered when changing the cooling mode.
基金supported by the National Natural Science Foundation of China (Grant Nos. 10647132 and 11104113)the Scientific Research Fund of Hunan Provincial Education Department of China (Grant No. 10A100)
文摘Optomechanical dynamics in two systems which are a transmission line resonator and Fabrya-Perot optical cavity via radiation-pressure are investigated by linearized quantum Langevin equation. We work in the resolved sideband regime where the oscillator resonance frequency exceeds the cavity linewidth. Normal mode splittings of the mechanical resonator as a pure result of the coupling interaction in the two optomechanical systems is studied, and we make a comparison of normal mode splitting of mechanical resonator between the two systems. In the optical cavity, the normal mode splitting of the movable mirror approaches the latest experiment very well. In addition, an approximation scheme is introduced to demonstrate the ground state cooling, and we make a comparison of cooling between the two systems dominated by two key factors, which are the initial bath temperature and the mechanical quality factor. Since both the normal mode splitting and cooling require working in the resolved sideband regime, whether the normal mode splitting influences the cooling of the mirror is considered. Considering the size of the mechanical resonator and precooling the system, the mechanical resonator in the transmission line resonator system is easier to achieve the ground state cooling than in optical cavity.
基金Project supported by the State Key Program of National Natural Science Foundation of China(No.11332007)the Young Scientists Fund of the National Natural Science Foundation of China(No.11402167)
文摘The instability of the Mack mode is destabilized by wall-cooling in a high speed boundary layer. The aim of this paper is to study the mechanism of the wall cooling effect on the Mack mode instability by numerical methods. It is shown that the wall-cooling can destabilize the Mack mode instability, similar to the previous conclusions with the exception that the Mack mode instability can be stabilized by wall-cooling if the wall temperature is extremely low. The reversed wall temperature is related to a freestream condition. If the Mach number increases to a large enough value, e.g., about 7, the reversed wall temperature will tend to be zero. It seems that the Mack mode instability is determined by the region between the boundary layer edge and the critical layer. When the wall temperature decreases, this region becomes wider, and the boundary layer becomes more unstable. Additionally, a relative supersonic unstable mode can be observed when the velocity of the critical layer is less than 1 - liMa or is cancelled by the wall-cooling effect. These results provide a deeper understanding on the wall-cooling effect in high speed boundary layers.
基金supported by National Basic Research Program of China(973 Program)(No.2013GB102000)
文摘An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and L3. The influence rule of different factors on the cooling effect and thermal stress of the plate were studied, for which the influence rank was respectively R 〉 L1 〉 L3 and L3 〉 R 〉 L1. The highest temperature value decreased when R and L1 increased~ and the maximum thermal stress value dropped when R, L1 and L3 increased. The final optimized results can be summarized as: R equals 6 mm or 7 mm, L1 equals 19 mm, and L3 equals 20 mm. Compared with the initial design, the highest temperature value had a small decline~ and the maximum thermal stress value dropped by 19~ to 24~. So it was not ideal to improve the cooling effect by optimizing the geometry sizes of the water-cooled structure, even worse than increasing the flow speed, but it was very effective for dropping the maximum thermal stress value. The orthogoaal experimental method reduces the number of experiments by 80%, and thus it is feasible and effective to optimize the water-cooled structure of the divertor plate with the orthogonal theory.
基金Project(50604018) supported by the National Natural Science Foundation of China
文摘LiFePO4 was prepared by heating the pre-decomposed precursor mixtures sealed in vacuum quartz-tube. Three kinds of cooling modes including nature cooling, air quenching, and water quenching were applied to comparing the effects of cooling modes on the microstructure and electrochemical characteristics of the material. The results indicate that the water quenching mode can control overgrowth of the grain size of final product and improve its electrochemical performance compared with nature cooling mode and air quenching mode. The sample synthesized by using water quenching mode is of the highest reversible discharge specific capacity and the best cyclic electrochemical performance, demonstrating the first discharge capacity of 138.1 mA·h/g at 0.1C rate and the total loss of capacity of 3.11% after 20 cycles.
文摘The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced.
基金supported by the Natural Science Foundation of Jiangsu Province(Grant No.BK2012163)University Science Research Project of Jiangsu Province(Grant No.11KJB460003)
文摘The microstructure and tensile properties of Sn-9Zn solder under different cooling and aging condition were studied. During solidification,the distribution of Zn-rich phases and grain size in the microstructure of Sn-9Zn solder were decided by the cooling rate. The Zn-rich phase in Sn-9Zn solder under furnace cooling,air cooling and water cooling media was separately existed as coarsen dendritic and needle like shape,fine needle like shape and very fine rod-like shape,respectively. After aging,the coarsen dendritic was broken and the coarsen needle like Zn-rich phase was partly changed into fine distribution of Zn-rich phase for Sn-9Zn solder with furnace cooling,and the rod-like Zn phase in the Sn-9Zn solder under water cooling was changed to conglomerated Zn with needle shape. During tensile testing on Sn-9Zn solder,tensile strength and ductility reached the best with water cooling,but decreased with aging effect. Meanwhile,the ductility of solder with air cooling and the strength of solder with furnace cooling increased with aging. The fracture mode was ductile and was independent of cooling media and aging effect. The size and depth of dimples decreased from water,furnace to air cooling.After aging,number and size of dimples increased on the solder with furnace cooling and air cooling. The change on the size of dimples for the Sn-9Zn solder under different cooling condition and with aging effect was accordance to the tensile properties.
基金supported by the National Natural Science Foundation of China (51907129)Project Supported by Department of Science and Technology of Liaoning Province (2021-MS-236)。
文摘Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind power generation and other fields. This paper introduces the basic structure of hybrid excitation motor with modular stator, and analyzes the operation principle of hybrid excitation motor. The cooling structure of the water-cooled plate is designed, and the effects of the thickness of the water-cooled plate and the number of water channels in the water-cooled plate on the heat dissipation capacity of the water-cooled plate are analyzed by theoretical and computational fluid dynamics methods. The effects of different water cooling plate structures on water velocity, pressure drop, water pump power consumption and heat dissipation capacity were compared and analyzed. The influence of different inlet flow velocity on the maximum temperature rise of each part of the motor is analyzed, and the temperature of each part of the motor under the optimal water flow is analyzed. The influence of the traditional spiral water jacket cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of the motor components is compared and analyzed. The results show that the water-cooled plate cooling structure is more suitable for the modular stator motor studied in this paper. Based on the water-cooled plate cooling structure, the air-water composite cooling structure is designed, and the effects of the air-water composite cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of each component of the motor are compared and analyzed. The results show that the maximum temperature rise of each component of the motor is reduced under the air-water composite cooling structure.
文摘With the stability analysis of hyperbolic cooling tower shells with ring-stiffeners. our paper proposes the linear pre-buckling consistent theory. The numerical result shows that this linear analysis method is very effective and practical in engineering, for its precision of compulation is up to the level of the nonlinear analysis when it is used for the study of critical loads of the hyperbolic cooling tower which is mainly governed by wind pressure and for the study of the effect of some oilier factors concerned in design on the buckling of shells. Based on that, we have obtained a scries of conclusions whicii will greatly benefits the engineering design when discussing the effect on the critical windloading of the shell which is caused by the following factors such as the position of rings, the number of rings and the dead weight.