BACKGROUND Iterative decomposition of water and fat with echo asymmetry and least squares estimation quantification sequence(IDEAL-IQ)is based on chemical shift-based water and fat separation technique to get proton d...BACKGROUND Iterative decomposition of water and fat with echo asymmetry and least squares estimation quantification sequence(IDEAL-IQ)is based on chemical shift-based water and fat separation technique to get proton density fat fraction.Multiple studies have shown that using IDEAL-IQ to test the stability and repeatability of liver fat is acceptable and has high accuracy.AIM To explore whether Gadoxetate Disodium(Gd-EOB-DTPA)interferes with the measurement of the hepatic fat content quantified with the IDEAL-IQ and to evaluate the robustness of this technique.METHODS IDEAL-IQ was used to quantify the liver fat content at 3.0T in 65 patients injected with Gd-EOB-DTPA contrast.After injection,IDEAL-IQ was estimated four times,and the fat fraction(FF)and R2* were measured at the following time points:Precontrast,between the portal phase(70 s)and the late phase(180 s),the delayed phase(5 min)and the hepatobiliary phase(20 min).One-way repeated-measures analysis was conducted to evaluate the difference in the FFs between the four time points.Bland-Altman plots were adopted to assess the FF changes before and after injection of the contrast agent.P<0.05 was considered statistically significant.RESULTS The assessment of the FF at the four time points in the liver,spleen and spine showed no significant differences,and the measurements of hepatic FF yielded good consistency between T1 and T2[95%confidence interval:-0.6768%,0.6658%],T1 and T3(-0.3900%,0.3178%),and T1 and T4(-0.3750%,0.2825%).R2* of the liver,spleen and spine increased significantly after injection(P<0.0001).CONCLUSION Using the IDEAL-IQ sequence to measure the FF,we can obtain results that will not be affected by Gd-EOB-DTPA.The high reproducibility of the IDEAL-IQ sequence makes it available in the scanning interval to save time during multiphase examinations.展开更多
Four peptides PSPP1,PSPP2,PSPP3 and PSPP4 were purified from the water-extract of Papaver somniferum pollen.Their sequences,with 21,17,13 and 16 amino acid residues respectively,have been determined by Edman degradati...Four peptides PSPP1,PSPP2,PSPP3 and PSPP4 were purified from the water-extract of Papaver somniferum pollen.Their sequences,with 21,17,13 and 16 amino acid residues respectively,have been determined by Edman degradation-N-terminal dansylation.PSPP2, PSPP3 and PSPP4 were synthesized using solid phase method.The immunopromotive activities of PSPP1,PSPP2,PSPP3,PSPP4 and the initially separated sample PSPP have been also observed by the methods of counting erythrocyte rosette forming cells(ERFC) and T-lymphocyte transformation test in vitro.展开更多
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee...Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples.展开更多
According to the characteristics of frequent water level step-variation in the Wanquan Well, the step-variation frequency change on the time axis can be regarded as a sequence of step-variation. A study of the relati...According to the characteristics of frequent water level step-variation in the Wanquan Well, the step-variation frequency change on the time axis can be regarded as a sequence of step-variation. A study of the relationship between the process of development and evolution of the sequential step-variation and the regional seismicity indicated that the sequential step-variation anomalies are rather better in coincidence with the time, magnitude and frequency of regional seismic activities, which may predict the seismicity trend in months. Furthermore, on this basis, if the water level changes in a characteristic manner, the seismic regime during the time period from several days to 20 days or more may be evaluated. By using the method presented in this paper we had a prediction about the Baotou ML=6.6 earthquake on May 3, 1996. This event occurred within the predicted time span but with a less magnitude and a little location deviation.展开更多
Bacterial community in the drinking water distribution system (DWDS) was regulated by multiple environmental factors, many of which varied as a function of water age. In this study, four water samples with different...Bacterial community in the drinking water distribution system (DWDS) was regulated by multiple environmental factors, many of which varied as a function of water age. In this study, four water samples with different water ages, including finished water (FW, 0 d) and tap water (TW) [TWI (1 d), TW2(2 d) and TW3(3 d)], were collected along with the mains of a practical DWDS, and the bacterial community was investigated by high-throughput sequencing technique. Results indicated that the residual chlorine declined with the increase of water age, accompanied by the increase of dissolved organic matter, total bacteria counts and bacterial diversity (Shannon). For bacterial community composition, although Proteobacteria phylum (84.12%-97.6%) and Alphaproteobacteria class (67.42c/,~93.09%) kept dominate, an evident regular was observed at the order level. In detail, the relative abundance of most of other residual orders increased with different degrees from the start to the end of the DWDS, while a downward trend was uniquely observed in terms of Rhizobiales, who was inferred to be chlorine-resistant and be helpful for inhibiting pipes corrosion. Moreover, some OTUs were found to be closely related with species possessing pathogenicity and chlorine-resistant ability, so it was recommended that the use of agents other than chlorine or agents that can act synergically with chlorine should be developed for drinking water disinfection. This paper revealed bacterial community variations along the mains of the DWDS and the result was helpful for understanding bacterial ecology in the DWDS.展开更多
Disinfectants are commonly applied to control the growth of microorganisms in drinking water distribution systems. However, the effect of disinfection on drinking water microbial community remains poorly understood. T...Disinfectants are commonly applied to control the growth of microorganisms in drinking water distribution systems. However, the effect of disinfection on drinking water microbial community remains poorly understood. The present study investigated the impacts of different disinfectants(chlorine and chloramine) and dosages on biofilm bacterial community in bench-scale pipe section reactors. Illumina MiS eq sequencing illustrated that disinfection strategy could affect both bacterial diversity and community structure of drinking water biofilm. Proteobacteria tended to predominate in chloraminated drinking water biofilms, while Firmicutes in chlorinated and unchlorinated biofilms. The major proteobacterial groups were influenced by both disinfectant type and dosage. In addition, chloramination had a more profound impact on bacterial community than chlorination.展开更多
Delivery of safe and pathogen-free drinking water is crucial to public health.However,there exist challenges to the maintenance of the sterility of drinking water throughout the drinking water distribution systems(D...Delivery of safe and pathogen-free drinking water is crucial to public health.However,there exist challenges to the maintenance of the sterility of drinking water throughout the drinking water distribution systems(DWDS).Microbial growth in DWDS,such as growth of opportunistic pathogenic microorganisms,can lead to severe health problems in consumers(Berry et al.,2006;Brettar and Hofle,2006;Lu et al.,2014;Zhang et al.,2015).展开更多
基金Supported by National Natural Science Foundation of China,No.82272053.
文摘BACKGROUND Iterative decomposition of water and fat with echo asymmetry and least squares estimation quantification sequence(IDEAL-IQ)is based on chemical shift-based water and fat separation technique to get proton density fat fraction.Multiple studies have shown that using IDEAL-IQ to test the stability and repeatability of liver fat is acceptable and has high accuracy.AIM To explore whether Gadoxetate Disodium(Gd-EOB-DTPA)interferes with the measurement of the hepatic fat content quantified with the IDEAL-IQ and to evaluate the robustness of this technique.METHODS IDEAL-IQ was used to quantify the liver fat content at 3.0T in 65 patients injected with Gd-EOB-DTPA contrast.After injection,IDEAL-IQ was estimated four times,and the fat fraction(FF)and R2* were measured at the following time points:Precontrast,between the portal phase(70 s)and the late phase(180 s),the delayed phase(5 min)and the hepatobiliary phase(20 min).One-way repeated-measures analysis was conducted to evaluate the difference in the FFs between the four time points.Bland-Altman plots were adopted to assess the FF changes before and after injection of the contrast agent.P<0.05 was considered statistically significant.RESULTS The assessment of the FF at the four time points in the liver,spleen and spine showed no significant differences,and the measurements of hepatic FF yielded good consistency between T1 and T2[95%confidence interval:-0.6768%,0.6658%],T1 and T3(-0.3900%,0.3178%),and T1 and T4(-0.3750%,0.2825%).R2* of the liver,spleen and spine increased significantly after injection(P<0.0001).CONCLUSION Using the IDEAL-IQ sequence to measure the FF,we can obtain results that will not be affected by Gd-EOB-DTPA.The high reproducibility of the IDEAL-IQ sequence makes it available in the scanning interval to save time during multiphase examinations.
文摘Four peptides PSPP1,PSPP2,PSPP3 and PSPP4 were purified from the water-extract of Papaver somniferum pollen.Their sequences,with 21,17,13 and 16 amino acid residues respectively,have been determined by Edman degradation-N-terminal dansylation.PSPP2, PSPP3 and PSPP4 were synthesized using solid phase method.The immunopromotive activities of PSPP1,PSPP2,PSPP3,PSPP4 and the initially separated sample PSPP have been also observed by the methods of counting erythrocyte rosette forming cells(ERFC) and T-lymphocyte transformation test in vitro.
基金Supported by the Basic Scientific Fund for National Public Research Institutes of China(Nos.GY02-2011T10,2015P07)the Qingdao Talent Program(No.13-CX-20)+1 种基金the National Natural Science Foundation of China(Nos.31100567,41176061)the National Natural Science Foundation for Creative Groups(No.41521064)
文摘Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples.
文摘According to the characteristics of frequent water level step-variation in the Wanquan Well, the step-variation frequency change on the time axis can be regarded as a sequence of step-variation. A study of the relationship between the process of development and evolution of the sequential step-variation and the regional seismicity indicated that the sequential step-variation anomalies are rather better in coincidence with the time, magnitude and frequency of regional seismic activities, which may predict the seismicity trend in months. Furthermore, on this basis, if the water level changes in a characteristic manner, the seismic regime during the time period from several days to 20 days or more may be evaluated. By using the method presented in this paper we had a prediction about the Baotou ML=6.6 earthquake on May 3, 1996. This event occurred within the predicted time span but with a less magnitude and a little location deviation.
文摘Bacterial community in the drinking water distribution system (DWDS) was regulated by multiple environmental factors, many of which varied as a function of water age. In this study, four water samples with different water ages, including finished water (FW, 0 d) and tap water (TW) [TWI (1 d), TW2(2 d) and TW3(3 d)], were collected along with the mains of a practical DWDS, and the bacterial community was investigated by high-throughput sequencing technique. Results indicated that the residual chlorine declined with the increase of water age, accompanied by the increase of dissolved organic matter, total bacteria counts and bacterial diversity (Shannon). For bacterial community composition, although Proteobacteria phylum (84.12%-97.6%) and Alphaproteobacteria class (67.42c/,~93.09%) kept dominate, an evident regular was observed at the order level. In detail, the relative abundance of most of other residual orders increased with different degrees from the start to the end of the DWDS, while a downward trend was uniquely observed in terms of Rhizobiales, who was inferred to be chlorine-resistant and be helpful for inhibiting pipes corrosion. Moreover, some OTUs were found to be closely related with species possessing pathogenicity and chlorine-resistant ability, so it was recommended that the use of agents other than chlorine or agents that can act synergically with chlorine should be developed for drinking water disinfection. This paper revealed bacterial community variations along the mains of the DWDS and the result was helpful for understanding bacterial ecology in the DWDS.
基金financially supported by the State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (No. MARC2012D010)the National Water Special Program (No. 2012ZX07404-002)the International Science & Technology Cooperation Program of China (No. 2010DFA91830)
文摘Disinfectants are commonly applied to control the growth of microorganisms in drinking water distribution systems. However, the effect of disinfection on drinking water microbial community remains poorly understood. The present study investigated the impacts of different disinfectants(chlorine and chloramine) and dosages on biofilm bacterial community in bench-scale pipe section reactors. Illumina MiS eq sequencing illustrated that disinfection strategy could affect both bacterial diversity and community structure of drinking water biofilm. Proteobacteria tended to predominate in chloraminated drinking water biofilms, while Firmicutes in chlorinated and unchlorinated biofilms. The major proteobacterial groups were influenced by both disinfectant type and dosage. In addition, chloramination had a more profound impact on bacterial community than chlorination.
文摘Delivery of safe and pathogen-free drinking water is crucial to public health.However,there exist challenges to the maintenance of the sterility of drinking water throughout the drinking water distribution systems(DWDS).Microbial growth in DWDS,such as growth of opportunistic pathogenic microorganisms,can lead to severe health problems in consumers(Berry et al.,2006;Brettar and Hofle,2006;Lu et al.,2014;Zhang et al.,2015).