期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
The Impermeability Mechanism of Self-compacting Water Proof Concrete 被引量:2
1
作者 李厚祥 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第1期121-125,共5页
The impermeability mechanism of water-proof self-compacting concrete (WPSCC )w as studied. The mechanism and influential factors, such as water-cement ratio(w /c), dosage of powder, superplasticizer, sand content, agg... The impermeability mechanism of water-proof self-compacting concrete (WPSCC )w as studied. The mechanism and influential factors, such as water-cement ratio(w /c), dosage of powder, superplasticizer, sand content, aggregate conte nt, fly ash, UEA, PP fiber, on compactibility and crack resistance of WPSCC were analyzed. A type of WPSCC successfully applied in tunnel liner with its validit ies, conveniences and economies by mockup test was developed and optimized. Expe rimental results show that the WPSCC has good workability, mechanical properties and impermeability when reasonable requirements are fulfilled. 展开更多
关键词 self-compacting waterproof concrete IMPERMEABILITY MECHANISM
下载PDF
Numerical analysis and capacity evaluation of composite sprayed concrete lined tunnels 被引量:3
2
作者 Alan Bloodworth Jiang Su 《Underground Space》 SCIE EI 2018年第2期87-108,共22页
Spray-applied membranes for waterproofing of sprayed concrete tunnels have led to the possibility of shear transfer between primary and secondary linings through the membrane interface,with the potential for reducing o... Spray-applied membranes for waterproofing of sprayed concrete tunnels have led to the possibility of shear transfer between primary and secondary linings through the membrane interface,with the potential for reducing overall lining thickness.Laboratory tests have shown a reasonable degree of composite action in beam specimens.In this study,a numerical model previously calibrated against such tests is applied to a whole tunnel,considering soil–structure interaction and staged lining construction.The model shows composite action,and load sharing between the lining layers is expected in the tunnel as in the beams.Parametric studies over the practical range of interface stiffness values show that composite action is maintained,although at high interface stiffness,excessive bending may be imposed on the secondary lining,requiring additional reinforcement.An effcient composite shell design with minimal additional rein-forcement is achievable if the secondary lining thickness is reduced as compared to current practice.Robustness of the system,measured in terms of the interface’s ability to transfer stress under unequal loading causing distortion on the tunnel,is found to be generally ade-quate.However,adjacent construction in close proximity may provide insuffcient margin on membrane tensile de-bonding,particularly if the membrane is partially or fully saturated. 展开更多
关键词 Composite sprayed concrete lining Spray-applied waterproofing membrane Interface parameters Lining eficiency
原文传递