Despite advancements in neuroimaging,false positive diagnoses of intracranial aneurysms remain a significant concern.This article examines the causes,prevalence,and implications of such false-positive diagnoses.We dis...Despite advancements in neuroimaging,false positive diagnoses of intracranial aneurysms remain a significant concern.This article examines the causes,prevalence,and implications of such false-positive diagnoses.We discuss how conditions like arterial occlusion with vascular stump formation and infundibular widening can mimic aneurysms,particularly in the anterior circulation.The article compares various imaging modalities,including computer tomography angiogram,magnetic resonance imaging/angiography,and digital subtraction angiogram,highlighting their strengths and limitations.We emphasize the im-portance of accurate differentiation to avoid unnecessary surgical interventions.The potential of emerging technologies,such as high-resolution vessel wall ima-ging and deep neural networks for automated detection,is explored as promising avenues for improving diagnostic accuracy.This manuscript underscores the need for continued research and clinical vigilance in the diagnosis of intracranial aneurysms.展开更多
[Objective] The aim was to explore the reasons of false positives in Different Display Reverse Transcription(DDRT)analysis.[Method] Soybean varieties "Jilin 30" and "Tongnong 13" were used as materials to carry ...[Objective] The aim was to explore the reasons of false positives in Different Display Reverse Transcription(DDRT)analysis.[Method] Soybean varieties "Jilin 30" and "Tongnong 13" were used as materials to carry out analysis on false positives in DDRT analysis.[Result] An important origin of false positives appeared in DDRT analysis was the non-specific amplification caused by the combination of single primer and cDNA.The parallel PCR test of single primer should be set so as to verify whether the obtained fragments were the false positives or the PCR productions combined with single primer.[Conclusion] This study had provided basis for improving the success rate of DDRT experiment.展开更多
Introduction: HIV screening tests are routinely conducted on dialysis patients as the constant exposure of their blood during the dialysis process makes them a reasonable risk for blood-borne infections. However, in l...Introduction: HIV screening tests are routinely conducted on dialysis patients as the constant exposure of their blood during the dialysis process makes them a reasonable risk for blood-borne infections. However, in low prevalence settings, where HIV rates are <0.1% of the population, false positive results are more likely. This results in apprehension in the dialysis unit as breaches in infectious disease protocols could be presumed. This is illustrated in the case report below. Case Summary: A 62-year-old male Saudi end-stage kidney disease patient secondary to DM nephropathy began dialysis a year before presentation in a hemodialysis center in Saudi Arabia. Routine screening tests done at the start of dialysis revealed negative Hepatitis C, HIV 1 and 2 screening but a positive Hepatitis B surface antigen screen. The patient went for holiday dialysis at another facility and had a routine fourth-generation HIV test done which was positive. A confirmatory HIV PCR test was negative. Conclusion: This case highlights the need for caution in interpreting highly sensitive and specific HIV screening tests in a low-prevalence setting. Routine screening beyond the national recommendation may not be necessary in low-prevalence areas.展开更多
BACKGROUND:Rapid plasma regain positive and/or treponema pallidum hemagglutination negative [RPR(+)/TPHA(-)] results were designated as biologic false-positive (BFP).There are limited data about BFP reactions against ...BACKGROUND:Rapid plasma regain positive and/or treponema pallidum hemagglutination negative [RPR(+)/TPHA(-)] results were designated as biologic false-positive (BFP).There are limited data about BFP reactions against syphilis in patients with hepatitis C virus (HCV) infection.This study aimed to determine the prevalence of BFP reactions for syphilis in patients with HCV infection in a large sample and assess the relationship between BFP reactions and HCV infection.METHODS:A total of 2656 patients with positive anti-HCV and 5600 healthy control subjects were enrolled in this study.Hepatitis C serology was determined by a second generation ELISA test for HCV antibody.Syphilis serology was determined by the RPR test.Those subjects with reactive RPR positive underwent the TPHA test.Demographics and laboratory data were collected by trained clinicians.RESULTS:Among 2656 patients,111 (4.2%) had a reactive RPR test.Of the 111 patients who were subjected to reactive RPR test,30 (27.0%) showed HCV(+)/RPR(+).Of 5600 healthy controls,80 (1.4%) had a reactive RPR test.Fourteen (17.5%) controls with HCV(-)/RPR(+) had a non-reactive TPHA test.These represented 1.1% of all HCV-positive and 0.3% of all HCV-negative subjects (P<0.001).A significantly increased prevalence shown by false-positive tests for syphilis was observed in elderly HCV-seropositive patients.BFP-HCV positive group had a higher prevalence of eosinophilia.The eosinophil abnormality was compared between the patients and controls (66.7% vs 21.4%,P=0.0043).No significant results were observed in antinuclear antibodies,antiphospholipid and complement (C3,C4) (P>0.05).CONCLUSIONS:The data of this study demonstrate that HCV infection is associated with a false-positive RPR test.In this study BFPs were significantly more common in HCV positive patients compared to HCV-negative ones.Eosinophil abnormality can be considered as a predictor for BFP.Excessive BFPs must be considered in assessing the frequency of syphilis in a HCV-positive population and the importance of the treponemal specific serologic test should be emphasized for a diagnosis of syphilis in such population.展开更多
A new modification of false position method for solving nonlinear equations is presented by applying homotopy analysis method (HAM). Some numerical illustrations are given to show the efficiency of algorithm.
A wide variety of surgical related uptake has been reported on F18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography(FDG PET/CT) scan, most of which can be differentiated from neoplastic proces...A wide variety of surgical related uptake has been reported on F18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography(FDG PET/CT) scan, most of which can be differentiated from neoplastic process based on the pattern of FDG uptake and/or anatomic appearance on the integrated CT in image interpretation. A more potential problem we may be aware is postoperative reactive lymphadenitis, which may mimic regional nodal metastases on FDG PET/CT. This review presents five case examples demonstrating that postoperative reactive lymphadenitis could be a false-positive source for regional nodal metastasis on FDG PET/CT. Surgical oncologists and radiologists should be aware of reactive lymphadenitis in interpreting postoperative restaging FDG PET/CT scan when FDG avid lymphadenopathy is only seen in the lymphatic draining location from surgical site.展开更多
At present,with the development of technology,the detection of cryptococcal antigen(CRAG)plays an increasingly important role in the diagnosis of cryptococcosis.However,the three major CRAG detection technologies,late...At present,with the development of technology,the detection of cryptococcal antigen(CRAG)plays an increasingly important role in the diagnosis of cryptococcosis.However,the three major CRAG detection technologies,latex agglutination test(LA),lateral flow assay(LFA)and Enzyme-linked Immunosorbent Assay,have certain limitations.Although these techniques do not often lead to false-positive results,once this result occurs in a particular group of patients(such as human immunodeficiency virus patients),it might lead to severe consequences.展开更多
In Intrusion Detection Systems (IDS), the operation costs represent one of the big challenges for researchers. They are apart from the IDS cost acquisition and they comprise the costs of maintenance, administration, r...In Intrusion Detection Systems (IDS), the operation costs represent one of the big challenges for researchers. They are apart from the IDS cost acquisition and they comprise the costs of maintenance, administration, response, running and errors reactions costs. In the present paper, we focus on the missed reactions which include False Positive (FP) and False Negative (FN) reactions. For that a new optimization cost model is proposed for IDS. This optimization proposes a minimal interval where the IDSs work optimally. In simulation, we found this interval as a trade-off between the damage costs and the FP.展开更多
Objective To investigate if immunological factors associated with rheumatoid arthritis(RA) affect the result of human immunodeficiency virus(HIV) screening by electrochemiluminescence immunoassay(ECLIA) and enzyme-lin...Objective To investigate if immunological factors associated with rheumatoid arthritis(RA) affect the result of human immunodeficiency virus(HIV) screening by electrochemiluminescence immunoassay(ECLIA) and enzyme-linked immunosorbent assay(ELISA). Methods 100 RA cases were enrolled from January 2012 to February 2013 into this study. HIV screening was conducted with ECLIA detecting both HIV-1 p24 antigen, HIV-1 and HIV-2 antibodies, with ELISA and colloidal gold method detecting HIV-1 and HIV-2 antibodies. The samples producing positive results were submitted to the Center for Disease Control for confirmation using Western blotting method. The antibody titers of rheumatoid factors(RF) including RF-IgG, RF-IgM, RF-IgA, and CCP-IgG were analyzed by ELISA. Results The HIV positive-rate determined by ECLIA was significantly higher than that by ELISA and colloidal gold method(P<0.01). The false-positive rate of HIV screening was associated with antibody titers of RF-IgG, RF-IgM, RF-IgA, and CCP-IgG in RA(P<0.01). Conclusion Immunological factors, including RF and anti-CCP antibody, may influence the screening of HIV by ECLIA, producing false-positive result.展开更多
During the last decade, hundreds of studies have been pub- lished examining whether significant associations exist be- tween mitochondrial DNA (mtDNA) variants and/or haplogroups (clades) and particular diseases ...During the last decade, hundreds of studies have been pub- lished examining whether significant associations exist be- tween mitochondrial DNA (mtDNA) variants and/or haplogroups (clades) and particular diseases (generally com- mon/complex diseases) (Fig. 1). However, several authors have gathered evidence indicating a high incidence of false positive findings in mtDNA case-control association studies. Raule et al. (2007) and Herrnstadt and Howell (2004) showed various problems affecting mtDNA case-control association studies. Salas et al.展开更多
To solve the problem of poor detection and limited application range of current intrusion detection methods,this paper attempts to use deep learning neural network technology to study a new type of intrusion detection...To solve the problem of poor detection and limited application range of current intrusion detection methods,this paper attempts to use deep learning neural network technology to study a new type of intrusion detection method.Hence,we proposed an intrusion detection algorithm based on convolutional neural network(CNN)and AdaBoost algorithm.This algorithm uses CNN to extract the characteristics of network traffic data,which is particularly suitable for the analysis of continuous and classified attack data.The AdaBoost algorithm is used to classify network attack data that improved the detection effect of unbalanced data classification.We adopt the UNSW-NB15 dataset to test of this algorithm in the PyCharm environment.The results show that the detection rate of algorithm is99.27%and the false positive rate is lower than 0.98%.Comparative analysis shows that this algorithm has advantages over existing methods in terms of detection rate and false positive rate for small proportion of attack data.展开更多
文摘Despite advancements in neuroimaging,false positive diagnoses of intracranial aneurysms remain a significant concern.This article examines the causes,prevalence,and implications of such false-positive diagnoses.We discuss how conditions like arterial occlusion with vascular stump formation and infundibular widening can mimic aneurysms,particularly in the anterior circulation.The article compares various imaging modalities,including computer tomography angiogram,magnetic resonance imaging/angiography,and digital subtraction angiogram,highlighting their strengths and limitations.We emphasize the im-portance of accurate differentiation to avoid unnecessary surgical interventions.The potential of emerging technologies,such as high-resolution vessel wall ima-ging and deep neural networks for automated detection,is explored as promising avenues for improving diagnostic accuracy.This manuscript underscores the need for continued research and clinical vigilance in the diagnosis of intracranial aneurysms.
文摘[Objective] The aim was to explore the reasons of false positives in Different Display Reverse Transcription(DDRT)analysis.[Method] Soybean varieties "Jilin 30" and "Tongnong 13" were used as materials to carry out analysis on false positives in DDRT analysis.[Result] An important origin of false positives appeared in DDRT analysis was the non-specific amplification caused by the combination of single primer and cDNA.The parallel PCR test of single primer should be set so as to verify whether the obtained fragments were the false positives or the PCR productions combined with single primer.[Conclusion] This study had provided basis for improving the success rate of DDRT experiment.
文摘Introduction: HIV screening tests are routinely conducted on dialysis patients as the constant exposure of their blood during the dialysis process makes them a reasonable risk for blood-borne infections. However, in low prevalence settings, where HIV rates are <0.1% of the population, false positive results are more likely. This results in apprehension in the dialysis unit as breaches in infectious disease protocols could be presumed. This is illustrated in the case report below. Case Summary: A 62-year-old male Saudi end-stage kidney disease patient secondary to DM nephropathy began dialysis a year before presentation in a hemodialysis center in Saudi Arabia. Routine screening tests done at the start of dialysis revealed negative Hepatitis C, HIV 1 and 2 screening but a positive Hepatitis B surface antigen screen. The patient went for holiday dialysis at another facility and had a routine fourth-generation HIV test done which was positive. A confirmatory HIV PCR test was negative. Conclusion: This case highlights the need for caution in interpreting highly sensitive and specific HIV screening tests in a low-prevalence setting. Routine screening beyond the national recommendation may not be necessary in low-prevalence areas.
文摘BACKGROUND:Rapid plasma regain positive and/or treponema pallidum hemagglutination negative [RPR(+)/TPHA(-)] results were designated as biologic false-positive (BFP).There are limited data about BFP reactions against syphilis in patients with hepatitis C virus (HCV) infection.This study aimed to determine the prevalence of BFP reactions for syphilis in patients with HCV infection in a large sample and assess the relationship between BFP reactions and HCV infection.METHODS:A total of 2656 patients with positive anti-HCV and 5600 healthy control subjects were enrolled in this study.Hepatitis C serology was determined by a second generation ELISA test for HCV antibody.Syphilis serology was determined by the RPR test.Those subjects with reactive RPR positive underwent the TPHA test.Demographics and laboratory data were collected by trained clinicians.RESULTS:Among 2656 patients,111 (4.2%) had a reactive RPR test.Of the 111 patients who were subjected to reactive RPR test,30 (27.0%) showed HCV(+)/RPR(+).Of 5600 healthy controls,80 (1.4%) had a reactive RPR test.Fourteen (17.5%) controls with HCV(-)/RPR(+) had a non-reactive TPHA test.These represented 1.1% of all HCV-positive and 0.3% of all HCV-negative subjects (P<0.001).A significantly increased prevalence shown by false-positive tests for syphilis was observed in elderly HCV-seropositive patients.BFP-HCV positive group had a higher prevalence of eosinophilia.The eosinophil abnormality was compared between the patients and controls (66.7% vs 21.4%,P=0.0043).No significant results were observed in antinuclear antibodies,antiphospholipid and complement (C3,C4) (P>0.05).CONCLUSIONS:The data of this study demonstrate that HCV infection is associated with a false-positive RPR test.In this study BFPs were significantly more common in HCV positive patients compared to HCV-negative ones.Eosinophil abnormality can be considered as a predictor for BFP.Excessive BFPs must be considered in assessing the frequency of syphilis in a HCV-positive population and the importance of the treponemal specific serologic test should be emphasized for a diagnosis of syphilis in such population.
文摘A new modification of false position method for solving nonlinear equations is presented by applying homotopy analysis method (HAM). Some numerical illustrations are given to show the efficiency of algorithm.
文摘A wide variety of surgical related uptake has been reported on F18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography(FDG PET/CT) scan, most of which can be differentiated from neoplastic process based on the pattern of FDG uptake and/or anatomic appearance on the integrated CT in image interpretation. A more potential problem we may be aware is postoperative reactive lymphadenitis, which may mimic regional nodal metastases on FDG PET/CT. This review presents five case examples demonstrating that postoperative reactive lymphadenitis could be a false-positive source for regional nodal metastasis on FDG PET/CT. Surgical oncologists and radiologists should be aware of reactive lymphadenitis in interpreting postoperative restaging FDG PET/CT scan when FDG avid lymphadenopathy is only seen in the lymphatic draining location from surgical site.
基金Supported by the Key Discipline of Jiaxing Respiratory Medicine Construction Project,No.2019-zc-04.
文摘At present,with the development of technology,the detection of cryptococcal antigen(CRAG)plays an increasingly important role in the diagnosis of cryptococcosis.However,the three major CRAG detection technologies,latex agglutination test(LA),lateral flow assay(LFA)and Enzyme-linked Immunosorbent Assay,have certain limitations.Although these techniques do not often lead to false-positive results,once this result occurs in a particular group of patients(such as human immunodeficiency virus patients),it might lead to severe consequences.
文摘In Intrusion Detection Systems (IDS), the operation costs represent one of the big challenges for researchers. They are apart from the IDS cost acquisition and they comprise the costs of maintenance, administration, response, running and errors reactions costs. In the present paper, we focus on the missed reactions which include False Positive (FP) and False Negative (FN) reactions. For that a new optimization cost model is proposed for IDS. This optimization proposes a minimal interval where the IDSs work optimally. In simulation, we found this interval as a trade-off between the damage costs and the FP.
基金Supported by Shanghai Municipal Natural Science Foundation(11ZR1427000)
文摘Objective To investigate if immunological factors associated with rheumatoid arthritis(RA) affect the result of human immunodeficiency virus(HIV) screening by electrochemiluminescence immunoassay(ECLIA) and enzyme-linked immunosorbent assay(ELISA). Methods 100 RA cases were enrolled from January 2012 to February 2013 into this study. HIV screening was conducted with ECLIA detecting both HIV-1 p24 antigen, HIV-1 and HIV-2 antibodies, with ELISA and colloidal gold method detecting HIV-1 and HIV-2 antibodies. The samples producing positive results were submitted to the Center for Disease Control for confirmation using Western blotting method. The antibody titers of rheumatoid factors(RF) including RF-IgG, RF-IgM, RF-IgA, and CCP-IgG were analyzed by ELISA. Results The HIV positive-rate determined by ECLIA was significantly higher than that by ELISA and colloidal gold method(P<0.01). The false-positive rate of HIV screening was associated with antibody titers of RF-IgG, RF-IgM, RF-IgA, and CCP-IgG in RA(P<0.01). Conclusion Immunological factors, including RF and anti-CCP antibody, may influence the screening of HIV by ECLIA, producing false-positive result.
基金the "Ministerio de Ciencia e Innovacio'n"(No.SAF2011-26983)the Plan Galego IDT(No.EM 2012/045)the grant from the Sistema Universitario Gallego-Modalidad REDES(No.2012-PG226,to A.Salas) from the Xunta de Galicia
文摘During the last decade, hundreds of studies have been pub- lished examining whether significant associations exist be- tween mitochondrial DNA (mtDNA) variants and/or haplogroups (clades) and particular diseases (generally com- mon/complex diseases) (Fig. 1). However, several authors have gathered evidence indicating a high incidence of false positive findings in mtDNA case-control association studies. Raule et al. (2007) and Herrnstadt and Howell (2004) showed various problems affecting mtDNA case-control association studies. Salas et al.
基金supported in part by the National Key R&D Program of China(No.2022YFB3904503)National Natural Science Foundation of China(No.62172418)。
文摘To solve the problem of poor detection and limited application range of current intrusion detection methods,this paper attempts to use deep learning neural network technology to study a new type of intrusion detection method.Hence,we proposed an intrusion detection algorithm based on convolutional neural network(CNN)and AdaBoost algorithm.This algorithm uses CNN to extract the characteristics of network traffic data,which is particularly suitable for the analysis of continuous and classified attack data.The AdaBoost algorithm is used to classify network attack data that improved the detection effect of unbalanced data classification.We adopt the UNSW-NB15 dataset to test of this algorithm in the PyCharm environment.The results show that the detection rate of algorithm is99.27%and the false positive rate is lower than 0.98%.Comparative analysis shows that this algorithm has advantages over existing methods in terms of detection rate and false positive rate for small proportion of attack data.