BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate wheth...BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate whether combining the ratio of the cross diameters(RATIO)of the appendix with MOD of the appendix can enhance the diagnostic performance of acute appendicitis.METHODS A retrospective study was conducted,and medical records of 233 patients with acute appendicitis and 112 patients with a normal appendix were reviewed.The MOD and RATIO of the appendix were calculated and tested for their diagnostic performance of acute appendicitis,both individually and in combination.RESULTS The RATIO for a normal appendix was 1.32±0.16,while for acute appendicitis it was 1.09±0.07.The cut-off value for RATIO was determined to be≤1.18.The area under the receiver operating characteristic curve(AUC)for diagnosing acute appendicitis using RATIO≤1.18 and MOD>6 mm was 0.870 and 0.652,respectively.There was a significant difference in AUC between RATIO≤1.18 and MOD>6 mm(P<0.0001).When comparing the combination of RATIO≤1.18 and MOD>6 mm with MOD>6 mm alone,the combination showed increased specificity,positive predictive value(PPV),and AUC.However,the sensitivity and negative predictive value decreased.CONCLUSION Combining RATIO of the appendix≤1.18 and MOD>6 mm can significantly improve the specificity,PPV,and AUC in the US diagnosis of acute appendicitis.展开更多
Objective:Vesicoureteral reflux(VUR)index is a simple,validated tool that reliably predicts significant improvement and spontaneous resolution of primary reflux in children.The aim of this study was to evaluate and co...Objective:Vesicoureteral reflux(VUR)index is a simple,validated tool that reliably predicts significant improvement and spontaneous resolution of primary reflux in children.The aim of this study was to evaluate and compare the ureter diameter ratio(UDR)and VUR index(VURx)of patients treated with endoscopic injection(EI)and ureteroneocystostomy(UNC)methods in the pediatric age group due to primary VUR.Methods:Patients under the age of 18 years old who underwent EI and UNC with the diagnosis of primary VUR between January 2011 and September 2021 were determined as the participants.The UDR was assessed using voiding cystourethrography,and the VURx score was determined prior to treatment based on hospital records included in the study.Results:A total of 255 patients,60(23.5%)boys and 195(76.5%)girls,with a mean age of 76.5(range 13.0e204.0)months,were included in the study.EI was applied to 130(51.0%)patients and UNC was applied to 125(49.0%)patients due to primary VUR.The optimum cut-off for the distal UDR was obtained as 0.17 with sensitivity and specificity of 73.0%and 63.0%,respectively.The positive and negative predictive values were 66.0%and 70.0%,respectively.Conclusion:When the UDR and VURx score are evaluated together for the surgical treatment of primary VUR in the pediatric age group,it is thought that it may be useful in predicting the clinical course of the disease and evaluating surgical treatment options.展开更多
AIM: To validate whether the platelet count/spleen size ratio can be used to predict the presence of esophageal varices in Mexican patients with hepatic cirrhosis.
Residual coal pillars play an important role in mining the adjacent coal seam safely,managing the gobs and maintaining the stability of abandoned coal mines.The height to diameter ratio(H/D)affects the stability of re...Residual coal pillars play an important role in mining the adjacent coal seam safely,managing the gobs and maintaining the stability of abandoned coal mines.The height to diameter ratio(H/D)affects the stability of residual coal pillars.In this study,uniaxial compressive tests of coal specimens with five H/D(2.0,1.5,1.0,0.8 and 0.6)were performed,and the stress,strain and acoustic emission(AE)were monitored.Results show that the uniaxial compressive strength(UCS)and peak strain increase with H/D decreasing.An empirical equation is proposed to calculate the UCS based on the H/D.The AE activities during coal failure process can be separated into four periods.The span of quiet period and rapid decline period shorten with H/D decreasing.The smaller the H/D is,the more complicated the failure characteristics of coal will be.The failure form of coal with H/D of 2.0,1.5,and 1.0 is primarily shear failure,while splitting failure along the axial direction is the mainly mode when H/D is 0.8 or 0.6.The initiation,expansion,aggregation and connection of micro-cracks can be reflected by the real-time spatial evolution of AE event points.展开更多
An elastic vibration model for high length diameter ratio spinning rocket with attitude control system which can be used for trajectory simulation is established. The basic theory of elastic dynamics and vibration dy...An elastic vibration model for high length diameter ratio spinning rocket with attitude control system which can be used for trajectory simulation is established. The basic theory of elastic dynamics and vibration dynamics were both used to set up the elastic vibration model of rocket body. In order to study the problem more conveniently, the rocket's body was simplified to be an even beam with two free ends. The model was validated by simulation results and the test data.展开更多
AIM To determine the laboratory and radiologic parameters, including the platelet count(PC)-to-spleen diameter(SD) ratio as a non-invasive marker that may predict the presence of esophageal varices(EV) in children wit...AIM To determine the laboratory and radiologic parameters, including the platelet count(PC)-to-spleen diameter(SD) ratio as a non-invasive marker that may predict the presence of esophageal varices(EV) in children with cirrhosis.METHODS Eighty-nine patients with cirrhosis, but without a history of variceal bleeding were prospectively included. The children were grouped into 6-12 and 12-18 years of age groups. These groups were also divided into 2 subgroups(presence and absence of EV). All of the patients underwent a complete biochemical and radiologic evaluation. The PC(n/mm^3)-to-SD(mm) ratio was calculated for each patient. RESULTS Sixty-nine of 98(70.4%) patients had EV. The presence of ascites in all age groups was significantly associatedwith the presence of EV. There were no differences in serum albumin levels, PC, SD and the PC-to-SD ratio between the presence and absence of EV groups in both age groups(P > 0.05). CONCLUSION Laboratory and radiologic parameters, including the PC-to-SD ratio as a non-invasive marker(except for the presence of ascites), was inappropriate for detecting EV in children with cirrhosis.展开更多
In this paper, the factors of affecting surface roughness and profiles accuracy of the machined larege depth diamter ratio aspheric surfaces in ultra-precision grinding process are analyzed theoretically. An ultra-pre...In this paper, the factors of affecting surface roughness and profiles accuracy of the machined larege depth diamter ratio aspheric surfaces in ultra-precision grinding process are analyzed theoretically. An ultra-precision aspheric grinding system is then designed and manufactured. Aerostatic form is adopted to build the spindle of the workpiece, transverse guideway, longitudinal guideway and the spindle of the grinder in this system. The following specification is achieved, such as the turning accuracy of the spindle of the workpiece is 0.05 μm, radial rigidity of the spindle is GE 220N/μm, axial rigidity is GE 160 N/μm, radial rigidity of the guideway is GE 200N/μm, the highest rotational speed of the grinder is 80 000 rev/min and its turning accuracy is 0.1 μm, the resolution of linear displacement of the transverse and longitudinal guideway is 4.9 nm. Adjusting range of this adjusting mechanism is 2 mm in the Y direction, the adjusting accuracy of the precise adjusting mechanism is 0.1 μm. Micro displacement measuring system of this ultra-precision aspheric grinding adopts two-backfeed strategy, and angle displacement back-feed is realized by photoelectric encoder, it’s resolution is 655 360 pulse/rev. after 4 frequency multiplication, it’s angle displacement resolution is achieved 2 621 440 pulse/rev. Straight-line displacement is monitored by single frequency laser interferometer (DLSTAX LTM-20B, made in Japan). This CNC system adopts inimitable bi-arc step length flex CN interpolation algorithm, it’s CN system resolution is 5 nm.So this aspheric grinding system ensures profile accuracy of the machined part. The resolution of this interferometer is 5 nm. Finally, lots of ultra-precision grinding experiments are carried out on this grinding system. Some optical aspheric parts, with profiles accuracy of 0.3 μm, surface roughness less than 0.01 μm, are obtained.展开更多
Pure K2Ti4O9 whiskers were prepared by KDC(Kneading-Drying-Calcination) method with TiO2 and K2CO3 as raw materials. The influences of TiO2/K2CO3 molar ratio(RT/K), calcination temperature(TC) and cooling proces...Pure K2Ti4O9 whiskers were prepared by KDC(Kneading-Drying-Calcination) method with TiO2 and K2CO3 as raw materials. The influences of TiO2/K2CO3 molar ratio(RT/K), calcination temperature(TC) and cooling process on phase composition and morphology of the whiskers were investigated by TG-DSC(thermo gravimetric-differential scanning calorimeter), XRD(X-ray diffraction), and SEM(scanning electron microscope). Pure K2Ti4O9 potassium titanate whiskers with large length-diameter ratio(r)(over 250) can be obtained at RT/K = 2.9 and TC = 950 ℃.展开更多
Silicon carbide ceramics with different thicknesses/diameter ratios were prepared by using ultra-fine silicon carbide powder with the sintering additives of 1.0 wt% boron and 1.5 wt% carbon. The influence of thickness...Silicon carbide ceramics with different thicknesses/diameter ratios were prepared by using ultra-fine silicon carbide powder with the sintering additives of 1.0 wt% boron and 1.5 wt% carbon. The influence of thickness/diameter ratio on the microstructure and density of SiC ceramics was investigated in detail. The experimental results show that the addition of boron and carbon sintering aids can promote the densification process of SiC ceramic, leading to the low sintering temperature and improve mechanical properties. At 1950 ℃, SiC ceramic with a density of 99% exhibits Young's modulus, hardness, and flexural strength of 476 MPa, 28.3 GPa, and 334 MPa, respectively. It is found that long holding time has a positive effect on the uniformity of the microstructure and density distribution of SiC ceramics with large thickness/diameter ratios. Additionally, the sintering additive of boron can solid-solve into SiC, and then facilitate the phase transformation of SiC to form 6H-SiC and 4H-SiC composite ceramics.展开更多
Background Previous studies have shown that an echocardiographic right/left ventricular end-diastolic diameter ratio(RV/LV ratio)≥0.9 is an independent predictor of poor prognosis in patients with acute pulmonary emb...Background Previous studies have shown that an echocardiographic right/left ventricular end-diastolic diameter ratio(RV/LV ratio)≥0.9 is an independent predictor of poor prognosis in patients with acute pulmonary embolism. The prognostic value of the RV/LV ratio in patients with idiopathic pulmonary arterial hypertension(IPAH) is still unknown. Methods We retrospectively enrolled 95 consecutive patients with newly diagnosed IPAH and 16 of them were reevaluated by echocardiography at 3-12 months following targeted therapy.Follow-up data were obtained by telephone interviews and review of the patients’ records.Results The RV/LV ratio was in parallel with the severity of World Health Orgnization(WHO) functional class and mean right atrial pressure.The RV/LV ratio was positively correlated with total pulmonary resistance(P P P 2 saturation(P P = 0.001),weight and absence of targeted therapy were independent predictors of death.No significant changes in the RV/LV ratio before and after targeted therapy were observed. A baseline RV/LV ratio≥0.84 or a further increase in the RV/LV ratio during targeted therapy indicated a poor prognosis. Conclusions The RV/LV ratio helps to assess the severity of IPAH and serves as an independent predictor of prognosis in patients with IPAH.展开更多
文摘BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate whether combining the ratio of the cross diameters(RATIO)of the appendix with MOD of the appendix can enhance the diagnostic performance of acute appendicitis.METHODS A retrospective study was conducted,and medical records of 233 patients with acute appendicitis and 112 patients with a normal appendix were reviewed.The MOD and RATIO of the appendix were calculated and tested for their diagnostic performance of acute appendicitis,both individually and in combination.RESULTS The RATIO for a normal appendix was 1.32±0.16,while for acute appendicitis it was 1.09±0.07.The cut-off value for RATIO was determined to be≤1.18.The area under the receiver operating characteristic curve(AUC)for diagnosing acute appendicitis using RATIO≤1.18 and MOD>6 mm was 0.870 and 0.652,respectively.There was a significant difference in AUC between RATIO≤1.18 and MOD>6 mm(P<0.0001).When comparing the combination of RATIO≤1.18 and MOD>6 mm with MOD>6 mm alone,the combination showed increased specificity,positive predictive value(PPV),and AUC.However,the sensitivity and negative predictive value decreased.CONCLUSION Combining RATIO of the appendix≤1.18 and MOD>6 mm can significantly improve the specificity,PPV,and AUC in the US diagnosis of acute appendicitis.
文摘Objective:Vesicoureteral reflux(VUR)index is a simple,validated tool that reliably predicts significant improvement and spontaneous resolution of primary reflux in children.The aim of this study was to evaluate and compare the ureter diameter ratio(UDR)and VUR index(VURx)of patients treated with endoscopic injection(EI)and ureteroneocystostomy(UNC)methods in the pediatric age group due to primary VUR.Methods:Patients under the age of 18 years old who underwent EI and UNC with the diagnosis of primary VUR between January 2011 and September 2021 were determined as the participants.The UDR was assessed using voiding cystourethrography,and the VURx score was determined prior to treatment based on hospital records included in the study.Results:A total of 255 patients,60(23.5%)boys and 195(76.5%)girls,with a mean age of 76.5(range 13.0e204.0)months,were included in the study.EI was applied to 130(51.0%)patients and UNC was applied to 125(49.0%)patients due to primary VUR.The optimum cut-off for the distal UDR was obtained as 0.17 with sensitivity and specificity of 73.0%and 63.0%,respectively.The positive and negative predictive values were 66.0%and 70.0%,respectively.Conclusion:When the UDR and VURx score are evaluated together for the surgical treatment of primary VUR in the pediatric age group,it is thought that it may be useful in predicting the clinical course of the disease and evaluating surgical treatment options.
文摘AIM: To validate whether the platelet count/spleen size ratio can be used to predict the presence of esophageal varices in Mexican patients with hepatic cirrhosis.
基金Projects(51974192,52004172)supported by the National Natural Science Foundation of ChinaProject(51925402)supported by the Distinguished Youth Funds of National Natural Science Foundation of ChinaProject(U1710258)supported by the Joint Funds of National Natural Science Foundation of China and Shanxi Province,China。
文摘Residual coal pillars play an important role in mining the adjacent coal seam safely,managing the gobs and maintaining the stability of abandoned coal mines.The height to diameter ratio(H/D)affects the stability of residual coal pillars.In this study,uniaxial compressive tests of coal specimens with five H/D(2.0,1.5,1.0,0.8 and 0.6)were performed,and the stress,strain and acoustic emission(AE)were monitored.Results show that the uniaxial compressive strength(UCS)and peak strain increase with H/D decreasing.An empirical equation is proposed to calculate the UCS based on the H/D.The AE activities during coal failure process can be separated into four periods.The span of quiet period and rapid decline period shorten with H/D decreasing.The smaller the H/D is,the more complicated the failure characteristics of coal will be.The failure form of coal with H/D of 2.0,1.5,and 1.0 is primarily shear failure,while splitting failure along the axial direction is the mainly mode when H/D is 0.8 or 0.6.The initiation,expansion,aggregation and connection of micro-cracks can be reflected by the real-time spatial evolution of AE event points.
文摘An elastic vibration model for high length diameter ratio spinning rocket with attitude control system which can be used for trajectory simulation is established. The basic theory of elastic dynamics and vibration dynamics were both used to set up the elastic vibration model of rocket body. In order to study the problem more conveniently, the rocket's body was simplified to be an even beam with two free ends. The model was validated by simulation results and the test data.
文摘AIM To determine the laboratory and radiologic parameters, including the platelet count(PC)-to-spleen diameter(SD) ratio as a non-invasive marker that may predict the presence of esophageal varices(EV) in children with cirrhosis.METHODS Eighty-nine patients with cirrhosis, but without a history of variceal bleeding were prospectively included. The children were grouped into 6-12 and 12-18 years of age groups. These groups were also divided into 2 subgroups(presence and absence of EV). All of the patients underwent a complete biochemical and radiologic evaluation. The PC(n/mm^3)-to-SD(mm) ratio was calculated for each patient. RESULTS Sixty-nine of 98(70.4%) patients had EV. The presence of ascites in all age groups was significantly associatedwith the presence of EV. There were no differences in serum albumin levels, PC, SD and the PC-to-SD ratio between the presence and absence of EV groups in both age groups(P > 0.05). CONCLUSION Laboratory and radiologic parameters, including the PC-to-SD ratio as a non-invasive marker(except for the presence of ascites), was inappropriate for detecting EV in children with cirrhosis.
文摘In this paper, the factors of affecting surface roughness and profiles accuracy of the machined larege depth diamter ratio aspheric surfaces in ultra-precision grinding process are analyzed theoretically. An ultra-precision aspheric grinding system is then designed and manufactured. Aerostatic form is adopted to build the spindle of the workpiece, transverse guideway, longitudinal guideway and the spindle of the grinder in this system. The following specification is achieved, such as the turning accuracy of the spindle of the workpiece is 0.05 μm, radial rigidity of the spindle is GE 220N/μm, axial rigidity is GE 160 N/μm, radial rigidity of the guideway is GE 200N/μm, the highest rotational speed of the grinder is 80 000 rev/min and its turning accuracy is 0.1 μm, the resolution of linear displacement of the transverse and longitudinal guideway is 4.9 nm. Adjusting range of this adjusting mechanism is 2 mm in the Y direction, the adjusting accuracy of the precise adjusting mechanism is 0.1 μm. Micro displacement measuring system of this ultra-precision aspheric grinding adopts two-backfeed strategy, and angle displacement back-feed is realized by photoelectric encoder, it’s resolution is 655 360 pulse/rev. after 4 frequency multiplication, it’s angle displacement resolution is achieved 2 621 440 pulse/rev. Straight-line displacement is monitored by single frequency laser interferometer (DLSTAX LTM-20B, made in Japan). This CNC system adopts inimitable bi-arc step length flex CN interpolation algorithm, it’s CN system resolution is 5 nm.So this aspheric grinding system ensures profile accuracy of the machined part. The resolution of this interferometer is 5 nm. Finally, lots of ultra-precision grinding experiments are carried out on this grinding system. Some optical aspheric parts, with profiles accuracy of 0.3 μm, surface roughness less than 0.01 μm, are obtained.
基金Funded by the Natural Science Foundation Key Project of Hubei Province(No.2011CDA060)
文摘Pure K2Ti4O9 whiskers were prepared by KDC(Kneading-Drying-Calcination) method with TiO2 and K2CO3 as raw materials. The influences of TiO2/K2CO3 molar ratio(RT/K), calcination temperature(TC) and cooling process on phase composition and morphology of the whiskers were investigated by TG-DSC(thermo gravimetric-differential scanning calorimeter), XRD(X-ray diffraction), and SEM(scanning electron microscope). Pure K2Ti4O9 potassium titanate whiskers with large length-diameter ratio(r)(over 250) can be obtained at RT/K = 2.9 and TC = 950 ℃.
基金Funded by the National Key Research and Development Plan of China (No.2017YFB0310400)the National Natural Science Foundation of China (No.5167020705)
文摘Silicon carbide ceramics with different thicknesses/diameter ratios were prepared by using ultra-fine silicon carbide powder with the sintering additives of 1.0 wt% boron and 1.5 wt% carbon. The influence of thickness/diameter ratio on the microstructure and density of SiC ceramics was investigated in detail. The experimental results show that the addition of boron and carbon sintering aids can promote the densification process of SiC ceramic, leading to the low sintering temperature and improve mechanical properties. At 1950 ℃, SiC ceramic with a density of 99% exhibits Young's modulus, hardness, and flexural strength of 476 MPa, 28.3 GPa, and 334 MPa, respectively. It is found that long holding time has a positive effect on the uniformity of the microstructure and density distribution of SiC ceramics with large thickness/diameter ratios. Additionally, the sintering additive of boron can solid-solve into SiC, and then facilitate the phase transformation of SiC to form 6H-SiC and 4H-SiC composite ceramics.
文摘Background Previous studies have shown that an echocardiographic right/left ventricular end-diastolic diameter ratio(RV/LV ratio)≥0.9 is an independent predictor of poor prognosis in patients with acute pulmonary embolism. The prognostic value of the RV/LV ratio in patients with idiopathic pulmonary arterial hypertension(IPAH) is still unknown. Methods We retrospectively enrolled 95 consecutive patients with newly diagnosed IPAH and 16 of them were reevaluated by echocardiography at 3-12 months following targeted therapy.Follow-up data were obtained by telephone interviews and review of the patients’ records.Results The RV/LV ratio was in parallel with the severity of World Health Orgnization(WHO) functional class and mean right atrial pressure.The RV/LV ratio was positively correlated with total pulmonary resistance(P P P 2 saturation(P P = 0.001),weight and absence of targeted therapy were independent predictors of death.No significant changes in the RV/LV ratio before and after targeted therapy were observed. A baseline RV/LV ratio≥0.84 or a further increase in the RV/LV ratio during targeted therapy indicated a poor prognosis. Conclusions The RV/LV ratio helps to assess the severity of IPAH and serves as an independent predictor of prognosis in patients with IPAH.
基金National Natural Science Foundation of China(No.51906262)Natural Science Foundation of Hunan Province,China(No.2020JJ5735)Youth Excellent Sci-Tech Talents Training Plan under Hunan Provincial Sci-Tech Talents Sponsorship Program,China(No.2023TJ-N10)。