Keyhole Double-Sided Arc Welding Process 被引量:2
1
作者 Yuming ZHANG Shaobin ZHANG and bang JIANG Welding Research Laboratory, Center for Robottes and Manufacturing Systems, University of Kentucky, Lexington, Kentucky 40506, USA. Lin WU National Key Laboratory for Advanced Welding Production Technology, Harbi 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2001年第1期159-160,共2页
In the proposed method, the current/arc is guided through the keyhole so that the energy of the plasma jet is compensated while it is consumed in heating the workpiece along the keyhole. As a result, deep narrow penet... In the proposed method, the current/arc is guided through the keyhole so that the energy of the plasma jet is compensated while it is consumed in heating the workpiece along the keyhole. As a result, deep narrow penetration has been achieved on 12.7 mm (1/2") thick stainless steel plates using 70 A welding current. 展开更多
关键词 ARC Keyhole Double-Sided Arc welding process ZHANG
下载PDF
Statistical Analyses of the Effects of Welding Processes on Load, Extension and Hardness Properties of Welded Mild Steel Plates
2
作者 Dayo Hephzibah Oladebeye Samuel Babatope Adejuyigbe Biliyaminu Kareem 《Journal of Mechanics Engineering and Automation》 2020年第3期73-83,共11页
Mild steel plates of thicknesses 0.5 mm,0.6 mm,0.7 mm,0.8 mm,0.9 mm and 1.0 mm were prepared as test samples.After welding with the developed welding robot and manual electric arc welding machine these test samples we... Mild steel plates of thicknesses 0.5 mm,0.6 mm,0.7 mm,0.8 mm,0.9 mm and 1.0 mm were prepared as test samples.After welding with the developed welding robot and manual electric arc welding machine these test samples were subjected to Tensile Strength and Hardness tests.All data obtained including hardness,load and extension were analyzed and the data produced from electric arc welding operations,the robot welding operations and un-welded plates(control)were compared with one another.The statistical analyses of hardness,load and extension tests for developed welding robot,manual electric arc welding and un-welded(control)mild steel plates of different thicknesses were carried out.The results revealed that for hardness,the developed robot welding has the highest mean value of 115.30,standard deviation value of 14.32 and variance value of 205.06.The descriptive statistics of the load showed that the developed robot welding samples collectively have the lowest mean value of 2,536.85,standard deviation value of 704.21 and variance value of 495,911.72.The descriptive statistics of the extension in which the developed robot welding samples collectively have the lowest mean value of 1.29,standard deviation value of 0.43 and variance value of 0.18 were also determined.The result for hardness showed homogeneity of variance among hardness tests of the samples,which implies variation in the hardness test among the tests of the samples since p-value is 0.038.While the result for loads shows homogeneity of variance among loads of the samples in which the result reveals that there is no variation in the loads among the tests of the samples since p-value is 0.322.The result for extension shows homogeneity of variance among extensions of the samples in which it revealed that there is variation in the extensions among the tests of the samples since p-value is 0.011.The analysis of variance(ANOVA)test result revealed that there is a significant difference in the hardness of the samples in which developed robot welding operation gave the highest hardness compared with electric arc welding and un-welded(CONTROL)since p-value is 0.028.The ANOVA test result for load revealed that there is no significant difference in the loads of the samples since p-value is 0.51.The ANOVA test result of the extension shows that there is a significant difference in the extension of the samples in which developed robot welding operation gave the lowest extension compared with electric arc welding and un-welded(CONTROL)since p-value is 0.001.The results of hardness also showed the mean difference of 16.48 between developed robot welding and un-welded(CONTROL)samples and 7.26 between developed robot welding and electric arc welding samples.Finally,for extension the mean difference of-5.28 between developed robot welding and un-welded(CONTROL)samples and-1.22 between developed robot welding and electric arc welding samples were established. 展开更多
关键词 Statistical analysis welding processes LOAD EXTENSION HARDNESS mild steel.
下载PDF
The Mesozoic Welding Process between South and North Dabie Blocks:An Evidence from Pb Isotopes of Yanshanian Granites
3
作者 WANG Qiang ZHAO Zhenhua +2 位作者 QIU Jiaxiang WANG Renjing LIU Yuanjun 《资源环境与工程》 2016年第B04期129-130,共2页
The Pb isotope compositions of K-feldspar in granites is paid more and more geologists'attention,due to their importance of tracer.It is a fact that South Dabie Block(SDB)and North Dabie Block(NDB)had exited since... The Pb isotope compositions of K-feldspar in granites is paid more and more geologists'attention,due to their importance of tracer.It is a fact that South Dabie Block(SDB)and North Dabie Block(NDB)had exited since Indosinian epoch(Wang et al.,1992;Cong et al,1994;Zhai et al.,1995;Chen et al.1995;Zhang et al,1996,Wang et al,1997).However,the welding process between SDB 展开更多
关键词 Pb The Mesozoic welding process between South and North Dabie Blocks