A single layer triangular patch antenna fed by an L-shaped probe was investigated numerically by using FDTD (Finite Difference Time Domain) method. It achieves >40% impedance bandwidth (VSWR<2) and stable radiat...A single layer triangular patch antenna fed by an L-shaped probe was investigated numerically by using FDTD (Finite Difference Time Domain) method. It achieves >40% impedance bandwidth (VSWR<2) and stable radiation pattern across the passband. The triangular patch antenna with two orientations of L-shaped probe has almost the same characteristics, such as impedance bandwidth and radiation pattern. The bandwidth vs feeding position was also investigated, the broadband characteristic can be observed when the feeding position is only in a small segment along the centerline.展开更多
This study evaluated the efficacy and safety of "J"-shaped uterine incision for caesarean section for patients diagnosed with placenta previa. A total of 55 consecutive cases of placenta previa treated in Union Hosp...This study evaluated the efficacy and safety of "J"-shaped uterine incision for caesarean section for patients diagnosed with placenta previa. A total of 55 consecutive cases of placenta previa treated in Union Hospital were retrospectively analyzed over a period of two years and 10 months. The subjects were divided into two groups with respect to the uterine incision. Twenty-four pregnant women with placenta previa who were indicated for caesarean section underwent the procedure using a new "J"-shaped uterine incision and 31 pregnant women with placenta previa received caesarean section that used the traditional transverse incision. The two groups were compared in terms of operation time, estimated blood loss, infant expulsion time, exhaust time and postoperative recovery. Meanwhile, comparison was also made in neonatal clinical data between the two groups. Compared with the "J"-shaped incision group, the traditional incision group had a lower Apgar scores (P〈0.05). However, there existed no statistically significant differences in the overall time of operation and postoperative period of breaking wind (P〉0.05). It is concluded that, with caesarean section for placenta previa patients, the "J"-shaped uterine incision significantly decreases intraoperative blood loss and facilitates the fetal delivery.展开更多
A new 4 H–SiC light triggered thyristor(LTT) with 7-shaped thin n-base doping profile is proposed and simulated using a two-dimensional numerical method. In this new structure, the bottom region of the thin n-base ...A new 4 H–SiC light triggered thyristor(LTT) with 7-shaped thin n-base doping profile is proposed and simulated using a two-dimensional numerical method. In this new structure, the bottom region of the thin n-base has a graded doping profile to induce an accelerating electric field and compensate for the shortcoming of the double-layer thin n-base structure in transmitting injected holes. In addition, the accelerating electric field can also speed up the transmission of photongenerated carriers during light triggering. As a result, the current gain of the top pnp transistor of the SiC LTT is further increased. According to the TCAD simulations, the turn-on delay time of the SiC LTT decreases by about 91.5% compared with that of previous double-layer thin n-base SiC LTT. The minimum turn-on delay time of the SiC LTT is only 828 ns,when triggered by 100 mW/cm^2 ultraviolet light. Meanwhile, there is only a slight degradation in the forward blocking characteristic.展开更多
BACKGROUND Robotic pancreaticoduodenectomy(RPD)can achieve similar surgical results to open and PD;however,RPD has a long learning curve and operation time(OT).To address this issue,we have summarized a surgical path ...BACKGROUND Robotic pancreaticoduodenectomy(RPD)can achieve similar surgical results to open and PD;however,RPD has a long learning curve and operation time(OT).To address this issue,we have summarized a surgical path to shorten the surgical learning curve and OT.AIM To investigate the effective learning curve of a“G”-shaped surgical approach in RPD for patients.METHODS A total of 60 patients,who received“G”-shaped RPD(GRPD)by a single surgeon in the First Hospital of Shanxi Medical University from May 2017 to April 2020,were included in this study.The OT,demographic data,intraoperative blood loss,complications,hospitalization time,and pathological results were recorded,and the cumulative sum(CUSUM)analysis was performed to evaluate the learning curve for GRPD.RESULTS According to the CUSUM analysis,the learning curve for GRPD was grouped into two phases:The early and late phases.The OT was 480±81.65 min vs 331±76.54 min,hospitalization time was 22±4.53 d vs 17±6.08 d,and blood loss was 308±54.78 mL vs 169.2±35.33 mL in the respective groups.Complications,including pancreatic fistula,bile leakage,reoperation rate,postoperative death,and delayed gastric emptying,were significantly decreased after this surgical technique.CONCLUSION GRPD can improve the learning curve and operative time,providing a new method for shortening the RPD learning curve.展开更多
To evaluate the retention properties of the novel ‘C'-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement(RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanic...To evaluate the retention properties of the novel ‘C'-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement(RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanical properties of the band were examined and the retention performance was characterized in the mesial, distal and vertical directions. A clinical trial was conducted using a spilt-mouth design on 50 patients. The novel C-shaped molar bands fit most molars without a repeated try-in process.The use of both nanoHA coating and RMGIC enhanced the tensile(8.00 ± 1.8 MPa) and shear strengths(27.17 ± 8.6 MPa) of the molar bands, leading to high retention in vertical, mesial and distal directions( p 〈 0.001). In clinical trials, the C-shaped molar bands had a failure rate(15%) comparable to that of traditional bands, and 93% of the failed bands demonstrated an adhesive remnant index score of 0, corroborating the observation that no luting agent residue remained on the tooth surface in most cases. The novel C-shaped molar bands appear to be a promising appliance that requires further clinical investigations, and may be used effectively in orthodontics.展开更多
Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper...Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper respiratory tract disease(URTD)and virulent systemic disease(FCV-VSD)[1].Infected cats usually presented with mouth ulcers,salivation and gingivitis-stomatitis.Furthermore,both recovered cats and asymptomatic carriers can still carry and spread the FCV virus for extended periods of time,contributing to the potential for outbreak.This presented a significant threat to the health and lives of cats,and rare wildlife and took a heavy financial loss on the pet industry,making the prevention and control of the virus difficult.Hence,rapid identification of FCV in clinical samples was necessary to prevent the spread of FCV and avoid financial loss.展开更多
A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including differe...A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including different coil structures,varies.In this study,two planar eddy current probes with differential pickup structures and the same size,Koch and circular probes,were used to compare lift-off effects.The eddy current distributions of the probes perturbed by 0°and 90°cracks were obtained by finite element analysis.The analysis results show that the 90°crack can impede the eddy current induced by the Koch probe even further at relatively low lift-off distance.The peak-to-peak values of the signal output from the two probes were compared at different lift-off distances using finite element analysis and experimental methods.In addition,the effects of different frequencies on the lift-off were studied experimentally.The results show that the signal peak-to-peak value of the Koch probe for the inspection of cracks in 90°orientation is larger than that of the circular probe when the lift-off distance is smaller than 1.2 mm.In addition,the influence of the lift-off distance on the peak-to-peak signal value of the two probes was studied via normalization.This indicates that the influence becomes more evident with an increase in excitation frequency.This research discloses the lift-off effect of differential planar eddy current probes with different coil shapes and proves the detection merit of the Koch probe for 90°cracks at low lift-off distances.展开更多
Uniaxial strain is a powerful tuning parameter that can control symmetry and anisotropic electronic properties in iron-based superconductors.However,accurately characterizing anisotropic strain can be challenging and ...Uniaxial strain is a powerful tuning parameter that can control symmetry and anisotropic electronic properties in iron-based superconductors.However,accurately characterizing anisotropic strain can be challenging and complex.Here,we utilize a cryogenic optical system equipped with a high-spatial-resolution microscope to characterize surface strains in iron-based superconductors using the digital image correlation method.Compared with other methods such as high-resolution x-ray diffraction,strain gauge,and capacitive sensor,digital image correlation offers a non-contact full-field measurement approach,acting as an optical virtual strain gauge that provides high spatial resolution.The results measured on detwinned BaFe_(2)As_(2)are quantitatively consistent with the distortion measured by x-ray diffraction and neutron Larmor diffraction.These findings highlight the potential of cryogenic digital image correlation as an effective and accessible tool for probing the isotropic and anisotropic strains,facilitating applications of uniaxial strain tuning in research of quantum materials.展开更多
Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affec...Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies.展开更多
A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparis...A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparison with a traditional tungsten emissive probe,including the operating temperature,the electron emission capability and the plasma potential measurement.Studies of the operating temperature and electron emission capability show that the tungsten emissive probe usually works at a temperature of 1800 K-2200 K while the oxide cathode emissive probe can function at about 1200 K-1400 K.In addition,plasma potential measurements using the oxide cathode emissive probe with different techniques have been accomplished in microwave electron cyclotron resonance plasmas with different discharge powers.It is found that a reliable plasma potential can be obtained using the improved inflection point method and the hot probe with zero emission limit method,while the floating point method is invalid for the oxide cathode emissive probe.展开更多
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be...In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus.展开更多
An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the...An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the substrate medium,we design a circular microstrip antenna,which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz,specifically suitable for NV center experiments.Subsequently,this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support,allowing the optical fiber tip to extend out of a dedicated aperture.To mitigate errors originating from processing,precise tuning within a narrow range can be achieved by adjusting the conformal amplitude.Finally,we image the microwave magnetic field around the integrated probe with high resolution,and determine the suitable area for placing the fiber tip(SAP).展开更多
A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examina...A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examination of this probe revealed its attributes and factors affecting its performance.By using temperature modulation,the probe was adept at detecting DCP concentrations ranging between 1.0×10^(-6)and 9.0×10^(-6)mol/L.Such a probe offers remarkable selectivity,repeatability,and robust stability,so that the detection of DCP can be carried out at different temperatures,and a fast,reliable,sensitive and low-cost intelligent detection method is realized.展开更多
Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluor...Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluorescence of terbium ions(Tb^(3+))via binding with single-strand DNA.Mercury ion,Hg^(2+)induced thymine(T)-rich DNA strand to form a double-strand structure(T-Hg^(2+)-T),thus leading to fluorescence reduction.Based on the principle,Hg^(2+)can be quantified based on the fluorescence of Tb^(3+),the limit of detection was 0.0689μmol/L and the linear range was 0.1-6.0μmol/L.Due to the specificity of T-Hg^(2+)-T artificial base pair,the assay could distinguish Hg^(2+)from other metal ions.The recovery rate was ranged in 98.71%-101.34%for detecting mercury pollution in three food samples.The assay is low-cost,separation-free and mix-to-read,thus was a competitive tool for detection of mercury pollution to ensure food safety.展开更多
Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,...Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,the rigid neural probes,such as Utah arrays,Michigan probes,and metal microfilament electrodes,are mechanically unmatched with brain tissue and are prone to rejection and glial scarring after implantation,which leads to a significant degradation in the signal quality with the implantation time.In recent years,flexible neural electrodes are rapidly developed with less damage to biological tissues,excellent biocompatibility,and mechanical compliance to alleviate scarring.Among them,the mechanical modeling is important for the optimization of the structure and the implantation process.In this review,the theoretical calculation of the flexible neural probes is firstly summarized with the processes of buckling,insertion,and relative interaction with soft brain tissue for flexible probes from outside to inside.Then,the corresponding mechanical simulation methods are organized considering multiple impact factors to realize minimally invasive implantation.Finally,the technical difficulties and future trends of mechanical modeling are discussed for the next-generation flexible neural probes,which is critical to realize low-invasiveness and long-term coexistence in vivo.展开更多
Objective The detection of RNA single nucleotide polymorphism(SNP)is of great importance due to their association with protein expression related to various diseases and drug responses.At present,splintR ligase-assist...Objective The detection of RNA single nucleotide polymorphism(SNP)is of great importance due to their association with protein expression related to various diseases and drug responses.At present,splintR ligase-assisted methods are important approaches for RNA direct detection,but its specificity will be limited when the fidelity of ligases is not ideal.The aim of this study was to create a method to improve the specificity of splintR ligase for RNA detection.Methods In this study,a dualcompetitive-padlock-probe(DCPLP)assay without the need for additional enzymes or reactions is proposed to improve specificity of splintR ligase ligation.To verify the method,we employed dual competitive padlock probe-mediated rolling circle amplification(DCPLP-RCA)to genotype the CYP2C9 gene.Results The specificity was well improved through the competition and strand displacement of dual padlock probe,with an 83.26%reduction in nonspecific signal.By detecting synthetic RNA samples,the method demonstrated a dynamic detection range of 10 pmol/L-1 nmol/L.Furthermore,clinical samples were applied to the method to evaluate its performance,and the genotyping results were consistent with those obtained using the qPCR method.Conclusion This study has successfully established a highly specific direct RNA SNP detection method,and provided a novel avenue for accurate identification of various types of RNAs.展开更多
The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA)....The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA). The TK6 cell line has the native p53 tumor-suppressor gene, whereas WTK1 cells contain a p53 mutation. Each cell line was isolated pre- and post-irradiation (2 and 3 Gy) and analyzed by MLPA. The impact of irradiation on these two cell lines was investigated using probes that target specific regions on chromosomes associated with subtelomeric regions. Results indicate that WTK1 and TK6 are impacted differently after irradiation, and that each cell line presents its own unique MLPA profile. The most notable differences are the appearance of a number of probes in the post-irradiated MLPA profile that are not present in the controls, and two unique probe signals only seen in WTK1 cells. These results build on our previous studies that indicate how different human cell lines can be affected by radiation in significantly different ways depending on the presence or absence of wild type p53.展开更多
Lithium hexafluorophosphate(LiPF_(6)),the most commonly used lithium battery electrolyte salt,is vulnerable to heat and humidity.Quantitative and qualitative determination the variation of LiPF_(6)have always relied o...Lithium hexafluorophosphate(LiPF_(6)),the most commonly used lithium battery electrolyte salt,is vulnerable to heat and humidity.Quantitative and qualitative determination the variation of LiPF_(6)have always relied on advanced equipment.Herein,we develop a fast,convenient,high-selective fluorescence detection method based on metal-organic cages(MOC),whose emission is enhanced by nearly 20 times in the presence of LiPF_(6)with good stability and photobleaching resistance.The fluorescent probe can also detect moisture in battery electrolyte.We propose and verify that the luminescence enhancement is due to the presence of hydrogen bond-induced enhanced emission effect in cages.Fluorescent excitation-emission matrix spectra and variable-temperature nuclear magnetic resonance spectroscopy are employed to clarify the role of hydrogen bonds in guest-loaded cages.Density functional theory(DFT)calculation is applied to simulate the structure of host-guest complexes and estimate the adsorption energy involved in the system.The precisely matched lock-and-key model paves a new way for designing and fabricating novel host structures,enabling specific recognition of other target compounds.展开更多
文摘A single layer triangular patch antenna fed by an L-shaped probe was investigated numerically by using FDTD (Finite Difference Time Domain) method. It achieves >40% impedance bandwidth (VSWR<2) and stable radiation pattern across the passband. The triangular patch antenna with two orientations of L-shaped probe has almost the same characteristics, such as impedance bandwidth and radiation pattern. The bandwidth vs feeding position was also investigated, the broadband characteristic can be observed when the feeding position is only in a small segment along the centerline.
基金supported by a grant from the National Natural Sciences Foundation of China (No. 30872776)
文摘This study evaluated the efficacy and safety of "J"-shaped uterine incision for caesarean section for patients diagnosed with placenta previa. A total of 55 consecutive cases of placenta previa treated in Union Hospital were retrospectively analyzed over a period of two years and 10 months. The subjects were divided into two groups with respect to the uterine incision. Twenty-four pregnant women with placenta previa who were indicated for caesarean section underwent the procedure using a new "J"-shaped uterine incision and 31 pregnant women with placenta previa received caesarean section that used the traditional transverse incision. The two groups were compared in terms of operation time, estimated blood loss, infant expulsion time, exhaust time and postoperative recovery. Meanwhile, comparison was also made in neonatal clinical data between the two groups. Compared with the "J"-shaped incision group, the traditional incision group had a lower Apgar scores (P〈0.05). However, there existed no statistically significant differences in the overall time of operation and postoperative period of breaking wind (P〉0.05). It is concluded that, with caesarean section for placenta previa patients, the "J"-shaped uterine incision significantly decreases intraoperative blood loss and facilitates the fetal delivery.
基金Project supported by the National Natural Science Foundation of China(Grant No.51677149)
文摘A new 4 H–SiC light triggered thyristor(LTT) with 7-shaped thin n-base doping profile is proposed and simulated using a two-dimensional numerical method. In this new structure, the bottom region of the thin n-base has a graded doping profile to induce an accelerating electric field and compensate for the shortcoming of the double-layer thin n-base structure in transmitting injected holes. In addition, the accelerating electric field can also speed up the transmission of photongenerated carriers during light triggering. As a result, the current gain of the top pnp transistor of the SiC LTT is further increased. According to the TCAD simulations, the turn-on delay time of the SiC LTT decreases by about 91.5% compared with that of previous double-layer thin n-base SiC LTT. The minimum turn-on delay time of the SiC LTT is only 828 ns,when triggered by 100 mW/cm^2 ultraviolet light. Meanwhile, there is only a slight degradation in the forward blocking characteristic.
基金Supported by Shanxi Provincial Science and Technology Department Social Development Fund,No.201903D321144.
文摘BACKGROUND Robotic pancreaticoduodenectomy(RPD)can achieve similar surgical results to open and PD;however,RPD has a long learning curve and operation time(OT).To address this issue,we have summarized a surgical path to shorten the surgical learning curve and OT.AIM To investigate the effective learning curve of a“G”-shaped surgical approach in RPD for patients.METHODS A total of 60 patients,who received“G”-shaped RPD(GRPD)by a single surgeon in the First Hospital of Shanxi Medical University from May 2017 to April 2020,were included in this study.The OT,demographic data,intraoperative blood loss,complications,hospitalization time,and pathological results were recorded,and the cumulative sum(CUSUM)analysis was performed to evaluate the learning curve for GRPD.RESULTS According to the CUSUM analysis,the learning curve for GRPD was grouped into two phases:The early and late phases.The OT was 480±81.65 min vs 331±76.54 min,hospitalization time was 22±4.53 d vs 17±6.08 d,and blood loss was 308±54.78 mL vs 169.2±35.33 mL in the respective groups.Complications,including pancreatic fistula,bile leakage,reoperation rate,postoperative death,and delayed gastric emptying,were significantly decreased after this surgical technique.CONCLUSION GRPD can improve the learning curve and operative time,providing a new method for shortening the RPD learning curve.
基金Funded by Department of Education,National Natural Science Foundation of China(No.81170960)Heilongjiang Province(No.11531204)+1 种基金Department of Health,Heilongjiang Province(No.2006-123)Youth Foundation of the Second Affiliated Hospital of Harbin Medical University(No.QN2006-13)
文摘To evaluate the retention properties of the novel ‘C'-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement(RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanical properties of the band were examined and the retention performance was characterized in the mesial, distal and vertical directions. A clinical trial was conducted using a spilt-mouth design on 50 patients. The novel C-shaped molar bands fit most molars without a repeated try-in process.The use of both nanoHA coating and RMGIC enhanced the tensile(8.00 ± 1.8 MPa) and shear strengths(27.17 ± 8.6 MPa) of the molar bands, leading to high retention in vertical, mesial and distal directions( p 〈 0.001). In clinical trials, the C-shaped molar bands had a failure rate(15%) comparable to that of traditional bands, and 93% of the failed bands demonstrated an adhesive remnant index score of 0, corroborating the observation that no luting agent residue remained on the tooth surface in most cases. The novel C-shaped molar bands appear to be a promising appliance that requires further clinical investigations, and may be used effectively in orthodontics.
基金supported by the natural science foundation reserve project of Jiangsu Agri-animal Husbandry Vocational College(No.NSF2023CB14).
文摘Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper respiratory tract disease(URTD)and virulent systemic disease(FCV-VSD)[1].Infected cats usually presented with mouth ulcers,salivation and gingivitis-stomatitis.Furthermore,both recovered cats and asymptomatic carriers can still carry and spread the FCV virus for extended periods of time,contributing to the potential for outbreak.This presented a significant threat to the health and lives of cats,and rare wildlife and took a heavy financial loss on the pet industry,making the prevention and control of the virus difficult.Hence,rapid identification of FCV in clinical samples was necessary to prevent the spread of FCV and avoid financial loss.
基金Supported by Gansu Provincial Natural Science Foundation of China(Grant No.22JR5RA229)National Natural Science Foundation of China(Grant Nos.51807086,12162021)Hongliu Youth Found of Lanzhou University of Technology and Gansu Provincial Outstanding Graduate Student Innovation Star of China(Grant No.2021CXZX-453).
文摘A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including different coil structures,varies.In this study,two planar eddy current probes with differential pickup structures and the same size,Koch and circular probes,were used to compare lift-off effects.The eddy current distributions of the probes perturbed by 0°and 90°cracks were obtained by finite element analysis.The analysis results show that the 90°crack can impede the eddy current induced by the Koch probe even further at relatively low lift-off distance.The peak-to-peak values of the signal output from the two probes were compared at different lift-off distances using finite element analysis and experimental methods.In addition,the effects of different frequencies on the lift-off were studied experimentally.The results show that the signal peak-to-peak value of the Koch probe for the inspection of cracks in 90°orientation is larger than that of the circular probe when the lift-off distance is smaller than 1.2 mm.In addition,the influence of the lift-off distance on the peak-to-peak signal value of the two probes was studied via normalization.This indicates that the influence becomes more evident with an increase in excitation frequency.This research discloses the lift-off effect of differential planar eddy current probes with different coil shapes and proves the detection merit of the Koch probe for 90°cracks at low lift-off distances.
基金supported by the National Key Research and Development Program of China(Grant No.2021YFA1400400)the Fundamental Research Funds for the Central Universities,and the National Natural Science Foundation of China(Grant Nos.12174029 and 11922402).
文摘Uniaxial strain is a powerful tuning parameter that can control symmetry and anisotropic electronic properties in iron-based superconductors.However,accurately characterizing anisotropic strain can be challenging and complex.Here,we utilize a cryogenic optical system equipped with a high-spatial-resolution microscope to characterize surface strains in iron-based superconductors using the digital image correlation method.Compared with other methods such as high-resolution x-ray diffraction,strain gauge,and capacitive sensor,digital image correlation offers a non-contact full-field measurement approach,acting as an optical virtual strain gauge that provides high spatial resolution.The results measured on detwinned BaFe_(2)As_(2)are quantitatively consistent with the distortion measured by x-ray diffraction and neutron Larmor diffraction.These findings highlight the potential of cryogenic digital image correlation as an effective and accessible tool for probing the isotropic and anisotropic strains,facilitating applications of uniaxial strain tuning in research of quantum materials.
基金supported by the National Natural Science Foundation of China(82072432)the China-Japan Friendship Hospital Horizontal Project/Spontaneous Research Funding(2022-HX-JC-7)+1 种基金the National High Level Hospital Clinical Research Funding(2022-NHLHCRF-PY-20)the Elite Medical Professionals project of China-Japan Friendship Hospital(ZRJY2021-GG12).
文摘Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies.
基金Project supported by the National Natural Science Foundation of China (Grant No.11905076)S&T Program of Hebei (Grant No.SZX2020034)。
文摘A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparison with a traditional tungsten emissive probe,including the operating temperature,the electron emission capability and the plasma potential measurement.Studies of the operating temperature and electron emission capability show that the tungsten emissive probe usually works at a temperature of 1800 K-2200 K while the oxide cathode emissive probe can function at about 1200 K-1400 K.In addition,plasma potential measurements using the oxide cathode emissive probe with different techniques have been accomplished in microwave electron cyclotron resonance plasmas with different discharge powers.It is found that a reliable plasma potential can be obtained using the improved inflection point method and the hot probe with zero emission limit method,while the floating point method is invalid for the oxide cathode emissive probe.
基金supported in part by the National Natural Science Foundation of China under Grants 61975091,61905015,61575108,and 61505034by the Tsinghua Precision Medicine Foundation and“Bio-Brain+X”Advanced Imaging Instrument Development Seed Grant.
文摘In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus.
基金Project supported by the National Key Research and Development Program of China(Grant No.2021YFB2012600)the Science and Technology Plan Project of State Administration of Market Regulation,China(Grant No.2021MK039)。
文摘An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the substrate medium,we design a circular microstrip antenna,which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz,specifically suitable for NV center experiments.Subsequently,this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support,allowing the optical fiber tip to extend out of a dedicated aperture.To mitigate errors originating from processing,precise tuning within a narrow range can be achieved by adjusting the conformal amplitude.Finally,we image the microwave magnetic field around the integrated probe with high resolution,and determine the suitable area for placing the fiber tip(SAP).
基金Funded by the Natural Science Foundation of Hubei Province(No.2022CFB861)the Wenhua College Research and Innovation Team(No.2022T01)。
文摘A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examination of this probe revealed its attributes and factors affecting its performance.By using temperature modulation,the probe was adept at detecting DCP concentrations ranging between 1.0×10^(-6)and 9.0×10^(-6)mol/L.Such a probe offers remarkable selectivity,repeatability,and robust stability,so that the detection of DCP can be carried out at different temperatures,and a fast,reliable,sensitive and low-cost intelligent detection method is realized.
基金financially supported by National Natural Science Foundation of China(22074100)the Young Elite Scientist Sponsorship Program by CAST(YESS20200036)+3 种基金the Researchers Supporting Project Number RSP-2021/138King Saud University,Riyadh,Saudi ArabiaTechnological Innovation R&D Project of Chengdu City(2019-YF05-31702266-SN)Sichuan University-Panzhihua City joint Project(2020CDPZH-5)。
文摘Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluorescence of terbium ions(Tb^(3+))via binding with single-strand DNA.Mercury ion,Hg^(2+)induced thymine(T)-rich DNA strand to form a double-strand structure(T-Hg^(2+)-T),thus leading to fluorescence reduction.Based on the principle,Hg^(2+)can be quantified based on the fluorescence of Tb^(3+),the limit of detection was 0.0689μmol/L and the linear range was 0.1-6.0μmol/L.Due to the specificity of T-Hg^(2+)-T artificial base pair,the assay could distinguish Hg^(2+)from other metal ions.The recovery rate was ranged in 98.71%-101.34%for detecting mercury pollution in three food samples.The assay is low-cost,separation-free and mix-to-read,thus was a competitive tool for detection of mercury pollution to ensure food safety.
基金support received from the National Natural Science Foundation of China(GrantNos.62204204 and 52175148)Science and Technology Innovation 2030-Major Project(Grant No.2022ZD0208601)+1 种基金Shanghai Sailing Program(Grant No.21YF1451000)Presidential Foundation of CAEP(Grant No.YZJJZQ2022001).
文摘Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,the rigid neural probes,such as Utah arrays,Michigan probes,and metal microfilament electrodes,are mechanically unmatched with brain tissue and are prone to rejection and glial scarring after implantation,which leads to a significant degradation in the signal quality with the implantation time.In recent years,flexible neural electrodes are rapidly developed with less damage to biological tissues,excellent biocompatibility,and mechanical compliance to alleviate scarring.Among them,the mechanical modeling is important for the optimization of the structure and the implantation process.In this review,the theoretical calculation of the flexible neural probes is firstly summarized with the processes of buckling,insertion,and relative interaction with soft brain tissue for flexible probes from outside to inside.Then,the corresponding mechanical simulation methods are organized considering multiple impact factors to realize minimally invasive implantation.Finally,the technical difficulties and future trends of mechanical modeling are discussed for the next-generation flexible neural probes,which is critical to realize low-invasiveness and long-term coexistence in vivo.
文摘Objective The detection of RNA single nucleotide polymorphism(SNP)is of great importance due to their association with protein expression related to various diseases and drug responses.At present,splintR ligase-assisted methods are important approaches for RNA direct detection,but its specificity will be limited when the fidelity of ligases is not ideal.The aim of this study was to create a method to improve the specificity of splintR ligase for RNA detection.Methods In this study,a dualcompetitive-padlock-probe(DCPLP)assay without the need for additional enzymes or reactions is proposed to improve specificity of splintR ligase ligation.To verify the method,we employed dual competitive padlock probe-mediated rolling circle amplification(DCPLP-RCA)to genotype the CYP2C9 gene.Results The specificity was well improved through the competition and strand displacement of dual padlock probe,with an 83.26%reduction in nonspecific signal.By detecting synthetic RNA samples,the method demonstrated a dynamic detection range of 10 pmol/L-1 nmol/L.Furthermore,clinical samples were applied to the method to evaluate its performance,and the genotyping results were consistent with those obtained using the qPCR method.Conclusion This study has successfully established a highly specific direct RNA SNP detection method,and provided a novel avenue for accurate identification of various types of RNAs.
文摘The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA). The TK6 cell line has the native p53 tumor-suppressor gene, whereas WTK1 cells contain a p53 mutation. Each cell line was isolated pre- and post-irradiation (2 and 3 Gy) and analyzed by MLPA. The impact of irradiation on these two cell lines was investigated using probes that target specific regions on chromosomes associated with subtelomeric regions. Results indicate that WTK1 and TK6 are impacted differently after irradiation, and that each cell line presents its own unique MLPA profile. The most notable differences are the appearance of a number of probes in the post-irradiated MLPA profile that are not present in the controls, and two unique probe signals only seen in WTK1 cells. These results build on our previous studies that indicate how different human cell lines can be affected by radiation in significantly different ways depending on the presence or absence of wild type p53.
基金supported by National Natural Science Foundation of China(No.22278308,22109114 and 22102099)。
文摘Lithium hexafluorophosphate(LiPF_(6)),the most commonly used lithium battery electrolyte salt,is vulnerable to heat and humidity.Quantitative and qualitative determination the variation of LiPF_(6)have always relied on advanced equipment.Herein,we develop a fast,convenient,high-selective fluorescence detection method based on metal-organic cages(MOC),whose emission is enhanced by nearly 20 times in the presence of LiPF_(6)with good stability and photobleaching resistance.The fluorescent probe can also detect moisture in battery electrolyte.We propose and verify that the luminescence enhancement is due to the presence of hydrogen bond-induced enhanced emission effect in cages.Fluorescent excitation-emission matrix spectra and variable-temperature nuclear magnetic resonance spectroscopy are employed to clarify the role of hydrogen bonds in guest-loaded cages.Density functional theory(DFT)calculation is applied to simulate the structure of host-guest complexes and estimate the adsorption energy involved in the system.The precisely matched lock-and-key model paves a new way for designing and fabricating novel host structures,enabling specific recognition of other target compounds.