Nonlinear model predictive control(NMPC)scheme is an effective method of multi-objective optimization control in complex industrial systems.In this paper,a NMPC scheme for the wet limestone flue gas desulphurization(W...Nonlinear model predictive control(NMPC)scheme is an effective method of multi-objective optimization control in complex industrial systems.In this paper,a NMPC scheme for the wet limestone flue gas desulphurization(WFGD)system is proposed which provides a more flexible framework of optimal control and decision-making compared with PID scheme.At first,a mathematical model of the FGD process is deduced which is suitable for NMPC structure.To equipoise the model’s accuracy and conciseness,the wet limestone FGD system is separated into several modules.Based on the conservation laws,a model with reasonable simplification is developed to describe dynamics of different modules for the purpose of controller design.Then,by addressing economic objectives directly into the NMPC scheme,the NMPC controller can minimize economic cost and track the set-point simultaneously.The accuracy of model is validated by the field data of a 1000 MW thermal power plant in Henan Province,China.The simulation results show that the NMPC strategy improves the economic performance and ensures the emission requirement at the same time.In the meantime,the control scheme satisfies the multiobjective control requirements under complex operation conditions(e.g.,boiler load fluctuation and set point variation).The mathematical model and NMPC structure provides the basic work for the future development of advanced optimized control algorithms in the wet limestone FGD systems.展开更多
In the paper, the gas-liquid two-phase flow performance and desulfurisation performance of the gas-liquid screen scrubber were experimentally studied when limestone was used as absorbent. Experiments were carried out ...In the paper, the gas-liquid two-phase flow performance and desulfurisation performance of the gas-liquid screen scrubber were experimentally studied when limestone was used as absorbent. Experiments were carried out at varying the flue gas velocity and slurry flux in concurrent and countercurrent tower respectively. The experimental results showed that the flow resistance of absorber increased rapidly with an increase of the flue gas velocity whether in concurrent or in countereurrent tower, and the up trend of the flow resistance in the cotmtercurrent tower was higher than those in the concurrent one. The influence of the flue gas velocity on the flow resistance of absorber was more than those of the slurry flux density. Whether in the concurrent tower or in the cotmtercurrent one, increasing the flue gas velocity or the slurry flux density would enhance the desulphurization efficiency. The influence of the slurry flux density on the desulfurisation efficiency was greater than those of the flue gas velocity.展开更多
Desulphurization of model and real oil samples was investigated using performic acid as oxidant assisted by air as co-oxidant. The catalysts used were Mo-oxide supported on ZSM-5 zeolite, which was synthesized in the ...Desulphurization of model and real oil samples was investigated using performic acid as oxidant assisted by air as co-oxidant. The catalysts used were Mo-oxide supported on ZSM-5 zeolite, which was synthesized in the laboratory and characterized by FT-IR, XRD, SEM and SSA analysis. In case of model oil, the optimum condition determined for complete oxidation of all the model compounds including thiophene, DBT and 4,6-DMDBT were;60?C, 60 min, ambient pressure and air flow rate of 100 mL/min. The oxidation reactivity decreased from 4,6-DMDBT to DBT and thiophene, which was found to follow pseudo first order kinetics. The real oil sample used in the study included untreated naphtha (NP), light gas oil (LGO), heavy gas oil (HGO) and Athabasca bitumen (Bit.). In case of NP and LGO the sulfur removal of above 78% was attained whereas in case of HGO and Bit. samples about 60% of desulfurization was achieved.展开更多
基金Financial support from the National Key R&D Program of China(No.2017YFB0601805)。
文摘Nonlinear model predictive control(NMPC)scheme is an effective method of multi-objective optimization control in complex industrial systems.In this paper,a NMPC scheme for the wet limestone flue gas desulphurization(WFGD)system is proposed which provides a more flexible framework of optimal control and decision-making compared with PID scheme.At first,a mathematical model of the FGD process is deduced which is suitable for NMPC structure.To equipoise the model’s accuracy and conciseness,the wet limestone FGD system is separated into several modules.Based on the conservation laws,a model with reasonable simplification is developed to describe dynamics of different modules for the purpose of controller design.Then,by addressing economic objectives directly into the NMPC scheme,the NMPC controller can minimize economic cost and track the set-point simultaneously.The accuracy of model is validated by the field data of a 1000 MW thermal power plant in Henan Province,China.The simulation results show that the NMPC strategy improves the economic performance and ensures the emission requirement at the same time.In the meantime,the control scheme satisfies the multiobjective control requirements under complex operation conditions(e.g.,boiler load fluctuation and set point variation).The mathematical model and NMPC structure provides the basic work for the future development of advanced optimized control algorithms in the wet limestone FGD systems.
基金Sponsored by the National Natural Science Foundation of China (Grant No 50476050) and the PHD Foundation of NCEPU
文摘In the paper, the gas-liquid two-phase flow performance and desulfurisation performance of the gas-liquid screen scrubber were experimentally studied when limestone was used as absorbent. Experiments were carried out at varying the flue gas velocity and slurry flux in concurrent and countercurrent tower respectively. The experimental results showed that the flow resistance of absorber increased rapidly with an increase of the flue gas velocity whether in concurrent or in countereurrent tower, and the up trend of the flow resistance in the cotmtercurrent tower was higher than those in the concurrent one. The influence of the flue gas velocity on the flow resistance of absorber was more than those of the slurry flux density. Whether in the concurrent tower or in the cotmtercurrent one, increasing the flue gas velocity or the slurry flux density would enhance the desulphurization efficiency. The influence of the slurry flux density on the desulfurisation efficiency was greater than those of the flue gas velocity.
文摘Desulphurization of model and real oil samples was investigated using performic acid as oxidant assisted by air as co-oxidant. The catalysts used were Mo-oxide supported on ZSM-5 zeolite, which was synthesized in the laboratory and characterized by FT-IR, XRD, SEM and SSA analysis. In case of model oil, the optimum condition determined for complete oxidation of all the model compounds including thiophene, DBT and 4,6-DMDBT were;60?C, 60 min, ambient pressure and air flow rate of 100 mL/min. The oxidation reactivity decreased from 4,6-DMDBT to DBT and thiophene, which was found to follow pseudo first order kinetics. The real oil sample used in the study included untreated naphtha (NP), light gas oil (LGO), heavy gas oil (HGO) and Athabasca bitumen (Bit.). In case of NP and LGO the sulfur removal of above 78% was attained whereas in case of HGO and Bit. samples about 60% of desulfurization was achieved.