Studies based on AC high voltage tests have been done at Cepel to investigate the performance of 800 kV busbar insulators under heavy wetting conditions.Insulators were tested which are now used on site and also with ...Studies based on AC high voltage tests have been done at Cepel to investigate the performance of 800 kV busbar insulators under heavy wetting conditions.Insulators were tested which are now used on site and also with different configurations of booster sheds.Images recorded by ultra-violet(UV) camera were used to help the investigations on the effectiveness of booster sheds.By comparing UV images of the insulator being stressed with high voltage under heavy artificial rain,with and without booster sheds,it was possible to observe how significant the reduction on the flashover formation process was when booster sheds were used.The effectiveness of booster sheds was also quantified by determining the disruptive discharge of the insulator with and without them.The results of these studies can also be considered as contribution to national and international standard technical committees to improving the standardized procedure for tests on ultra high voltage(UHV) insulators under heavy rain.Subjects such as the clear definition of relevant UHV test procedure and test arrangements,including the use of UV camera,have to be taken into account.展开更多
The increase of voltage level for AC and DC transmission systems requires some changes in the high voltage testing for Ultra High Voltage(UHV) equipment.After a short description of the coordination work in the standa...The increase of voltage level for AC and DC transmission systems requires some changes in the high voltage testing for Ultra High Voltage(UHV) equipment.After a short description of the coordination work in the standardization bodies the requirements for UHV equipment are mentioned.The main points concerning high voltage testing of UHV equipment are the impulse shape of standard lightning impulse voltage,the evaluation of the test voltage for impulses with oscillations or overshoot near the peak and the time parameter of switching impulses.The linearity check of the measuring devices,the proximity effect,the wet tests and the atmospheric correction factors are further points to be discussed concerning testing of UHV equipment.展开更多
文摘Studies based on AC high voltage tests have been done at Cepel to investigate the performance of 800 kV busbar insulators under heavy wetting conditions.Insulators were tested which are now used on site and also with different configurations of booster sheds.Images recorded by ultra-violet(UV) camera were used to help the investigations on the effectiveness of booster sheds.By comparing UV images of the insulator being stressed with high voltage under heavy artificial rain,with and without booster sheds,it was possible to observe how significant the reduction on the flashover formation process was when booster sheds were used.The effectiveness of booster sheds was also quantified by determining the disruptive discharge of the insulator with and without them.The results of these studies can also be considered as contribution to national and international standard technical committees to improving the standardized procedure for tests on ultra high voltage(UHV) insulators under heavy rain.Subjects such as the clear definition of relevant UHV test procedure and test arrangements,including the use of UV camera,have to be taken into account.
文摘The increase of voltage level for AC and DC transmission systems requires some changes in the high voltage testing for Ultra High Voltage(UHV) equipment.After a short description of the coordination work in the standardization bodies the requirements for UHV equipment are mentioned.The main points concerning high voltage testing of UHV equipment are the impulse shape of standard lightning impulse voltage,the evaluation of the test voltage for impulses with oscillations or overshoot near the peak and the time parameter of switching impulses.The linearity check of the measuring devices,the proximity effect,the wet tests and the atmospheric correction factors are further points to be discussed concerning testing of UHV equipment.