We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies r...We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies reached contradictory conclusions regarding device interchangeability,this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance,among these devices:A-scan,ultrasound biomicroscopy,Orbscan and Orbscan Ⅱ(Bausch&Lomb Surgical Inc.,San Dimas,California,USA),Pentacam and Pentacam HR(Oculus,Wetzlar,Germany),Galilei(Ziemer,Switzerland),Visante optical coherence tomography(Visante OCT,Carl Zeiss Meditec Inc.,Dublin,California,USA),lOLMaster(Carl Zeiss Meditec,Jena,Germany),and Lenstar LS 900/Biograph(Haag-Streit AG,Koeniz,Switzerland/Alcon Laboratories Inc.,Ft Worth,Texas,USA).展开更多
For the multisensor linear discrete time-invariant stochastic systems with correlated noises and unknown noise statistics,an on-line noise statistics estimator is presented by using the correlation method.Substituting...For the multisensor linear discrete time-invariant stochastic systems with correlated noises and unknown noise statistics,an on-line noise statistics estimator is presented by using the correlation method.Substituting it into the steady-state Riccati equation,the self-tuning Riccati equation is obtained.Using the Kalman filtering method,based on the self-tuning Riccati equation,a self-tuning weighted measurement fusion white noise deconvolution estimator is presented.By the dynamic error system analysis(DESA) method,it is proved that the self-tuning fusion white noise deconvolution estimator converges to the optimal fusion steadystate white noise deconvolution estimator in a realization,so that it has the asymptotic global optimality.A simulation example for Bernoulli-Gaussian input white noise shows its effectiveness.展开更多
The current paper is devoted to the study of the stochastic stability of FitzHugh-Nagumo systems perturbed by Gaussian white noise. First, the dynamics of stochastic FitzHugh-Nagumo systems are studied. Then, the exis...The current paper is devoted to the study of the stochastic stability of FitzHugh-Nagumo systems perturbed by Gaussian white noise. First, the dynamics of stochastic FitzHugh-Nagumo systems are studied. Then, the existence and uniqueness of their invariant measures, which mix exponentially are proved. Finally, the asymptotic behaviors of invariant measures when size of noise gets to zero are investigated.展开更多
文摘We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies reached contradictory conclusions regarding device interchangeability,this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance,among these devices:A-scan,ultrasound biomicroscopy,Orbscan and Orbscan Ⅱ(Bausch&Lomb Surgical Inc.,San Dimas,California,USA),Pentacam and Pentacam HR(Oculus,Wetzlar,Germany),Galilei(Ziemer,Switzerland),Visante optical coherence tomography(Visante OCT,Carl Zeiss Meditec Inc.,Dublin,California,USA),lOLMaster(Carl Zeiss Meditec,Jena,Germany),and Lenstar LS 900/Biograph(Haag-Streit AG,Koeniz,Switzerland/Alcon Laboratories Inc.,Ft Worth,Texas,USA).
基金supported by the National Natural Science Foundation of China(60874063)Science and Technology Research Foundation of Heilongjiang Education Department(11551355)Key Laboratory of Electronics Engineering,College of Heilongjiang Province(DZZD20105)
文摘For the multisensor linear discrete time-invariant stochastic systems with correlated noises and unknown noise statistics,an on-line noise statistics estimator is presented by using the correlation method.Substituting it into the steady-state Riccati equation,the self-tuning Riccati equation is obtained.Using the Kalman filtering method,based on the self-tuning Riccati equation,a self-tuning weighted measurement fusion white noise deconvolution estimator is presented.By the dynamic error system analysis(DESA) method,it is proved that the self-tuning fusion white noise deconvolution estimator converges to the optimal fusion steadystate white noise deconvolution estimator in a realization,so that it has the asymptotic global optimality.A simulation example for Bernoulli-Gaussian input white noise shows its effectiveness.
基金Project supported by the National Natural Science Foundation of China(No.10926096)
文摘The current paper is devoted to the study of the stochastic stability of FitzHugh-Nagumo systems perturbed by Gaussian white noise. First, the dynamics of stochastic FitzHugh-Nagumo systems are studied. Then, the existence and uniqueness of their invariant measures, which mix exponentially are proved. Finally, the asymptotic behaviors of invariant measures when size of noise gets to zero are investigated.