We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies r...We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies reached contradictory conclusions regarding device interchangeability,this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance,among these devices:A-scan,ultrasound biomicroscopy,Orbscan and Orbscan Ⅱ(Bausch&Lomb Surgical Inc.,San Dimas,California,USA),Pentacam and Pentacam HR(Oculus,Wetzlar,Germany),Galilei(Ziemer,Switzerland),Visante optical coherence tomography(Visante OCT,Carl Zeiss Meditec Inc.,Dublin,California,USA),lOLMaster(Carl Zeiss Meditec,Jena,Germany),and Lenstar LS 900/Biograph(Haag-Streit AG,Koeniz,Switzerland/Alcon Laboratories Inc.,Ft Worth,Texas,USA).展开更多
The current paper is devoted to the study of the stochastic stability of FitzHugh-Nagumo systems perturbed by Gaussian white noise. First, the dynamics of stochastic FitzHugh-Nagumo systems are studied. Then, the exis...The current paper is devoted to the study of the stochastic stability of FitzHugh-Nagumo systems perturbed by Gaussian white noise. First, the dynamics of stochastic FitzHugh-Nagumo systems are studied. Then, the existence and uniqueness of their invariant measures, which mix exponentially are proved. Finally, the asymptotic behaviors of invariant measures when size of noise gets to zero are investigated.展开更多
文摘We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies reached contradictory conclusions regarding device interchangeability,this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance,among these devices:A-scan,ultrasound biomicroscopy,Orbscan and Orbscan Ⅱ(Bausch&Lomb Surgical Inc.,San Dimas,California,USA),Pentacam and Pentacam HR(Oculus,Wetzlar,Germany),Galilei(Ziemer,Switzerland),Visante optical coherence tomography(Visante OCT,Carl Zeiss Meditec Inc.,Dublin,California,USA),lOLMaster(Carl Zeiss Meditec,Jena,Germany),and Lenstar LS 900/Biograph(Haag-Streit AG,Koeniz,Switzerland/Alcon Laboratories Inc.,Ft Worth,Texas,USA).
基金Project supported by the National Natural Science Foundation of China(No.10926096)
文摘The current paper is devoted to the study of the stochastic stability of FitzHugh-Nagumo systems perturbed by Gaussian white noise. First, the dynamics of stochastic FitzHugh-Nagumo systems are studied. Then, the existence and uniqueness of their invariant measures, which mix exponentially are proved. Finally, the asymptotic behaviors of invariant measures when size of noise gets to zero are investigated.