In order to investigate the relationship between the flow-field parameters outside the vehicle and the altitude,this paper takes the Atmospheric Reentry Demonstrator(ARD)with an angle of attack of-20°as the resea...In order to investigate the relationship between the flow-field parameters outside the vehicle and the altitude,this paper takes the Atmospheric Reentry Demonstrator(ARD)with an angle of attack of-20°as the research object and adopts a two-temperature model coupled with the shear-stress transport k-ωturbulence model to focus on the variation of flow-field parameters including flow-field pressure,Mach number and temperature with the reentry altitude.It is found that the flow-field high-pressure region and low-Mach region both appear in the shock layer near the head of the ARD,while the maximum pressure of the surface appears on the windward side of the ARD's head with a toroidal distribution,and the numerical magnitude is inversely proportional to the radius of the torus.With fluid through the shoulder of the ARD flow expansion plays a dominant role,the airflow velocity increases,the Mach number of the windward side of the rear cone increases and the flow-field pressure and surface pressure rapidly decrease.When the fluid passes through the shock layer,the translational-rotation temperature will increase before the vibration-electron temperature,there is a thermal non-equilibrium effect and the two temperatures will rapidly decrease again when approaching the surface of the ARD due to the existence of temperature gradient.At the same time,both the windward side of the shoulder and the back cover of the ARD suffer from a large thermal load and require thermal protection.展开更多
The stoichiometric ratios and related regimes, which can promote anti-flooding of polymer electrolyte membrane fuel cell (PEMFC) with in-plate adverse-flow flow-field (IPAF), were investigated. Two flow combinatio...The stoichiometric ratios and related regimes, which can promote anti-flooding of polymer electrolyte membrane fuel cell (PEMFC) with in-plate adverse-flow flow-field (IPAF), were investigated. Two flow combinations, which are the simple and complex adverse-flow between plates (ABP) that can be realized by IPAF, were employed. Constant stoichiometric ratios examination indicates that the complex ABP could improve anti-flooding of PEMFC better in the medium (greater than 200 mA/cm2 and less than 1 000 mA/cm2) and high (greater than 1 000 mA/cm2) current densities than the simple ABP. More stoichiometric ratios were introduced to find the cathode critical stoichiometry. Under the condition of cathode critical stoichiometry, the maximal local relative humidity of both electrodes of complex ABP is equal to 100% and below while the anti-flooding of the cathode of simple ABP is not satisfactory in the medium and high current densities. Further study shows that the mechanism of fuel cell, which is the imerdependence between the electrodes effect, can make significant contribution to anti-flooding.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.12175177)the China Postdoctoral Science Foundation(Grant No.2021M693889)。
文摘In order to investigate the relationship between the flow-field parameters outside the vehicle and the altitude,this paper takes the Atmospheric Reentry Demonstrator(ARD)with an angle of attack of-20°as the research object and adopts a two-temperature model coupled with the shear-stress transport k-ωturbulence model to focus on the variation of flow-field parameters including flow-field pressure,Mach number and temperature with the reentry altitude.It is found that the flow-field high-pressure region and low-Mach region both appear in the shock layer near the head of the ARD,while the maximum pressure of the surface appears on the windward side of the ARD's head with a toroidal distribution,and the numerical magnitude is inversely proportional to the radius of the torus.With fluid through the shoulder of the ARD flow expansion plays a dominant role,the airflow velocity increases,the Mach number of the windward side of the rear cone increases and the flow-field pressure and surface pressure rapidly decrease.When the fluid passes through the shock layer,the translational-rotation temperature will increase before the vibration-electron temperature,there is a thermal non-equilibrium effect and the two temperatures will rapidly decrease again when approaching the surface of the ARD due to the existence of temperature gradient.At the same time,both the windward side of the shoulder and the back cover of the ARD suffer from a large thermal load and require thermal protection.
基金Project(20976095) supported by the National Natural Science Foundation of ChinaProject(2012CB215500) supported by the National Basic Research Program of China+1 种基金Project(20090002110074) supported by the Specialized Research Fund for the Doctoral Program of Higher Education, ChinaProjects(2012AA1106012, 2012AA053402) supported by the National Hi-tech Research and Development Program of China
文摘The stoichiometric ratios and related regimes, which can promote anti-flooding of polymer electrolyte membrane fuel cell (PEMFC) with in-plate adverse-flow flow-field (IPAF), were investigated. Two flow combinations, which are the simple and complex adverse-flow between plates (ABP) that can be realized by IPAF, were employed. Constant stoichiometric ratios examination indicates that the complex ABP could improve anti-flooding of PEMFC better in the medium (greater than 200 mA/cm2 and less than 1 000 mA/cm2) and high (greater than 1 000 mA/cm2) current densities than the simple ABP. More stoichiometric ratios were introduced to find the cathode critical stoichiometry. Under the condition of cathode critical stoichiometry, the maximal local relative humidity of both electrodes of complex ABP is equal to 100% and below while the anti-flooding of the cathode of simple ABP is not satisfactory in the medium and high current densities. Further study shows that the mechanism of fuel cell, which is the imerdependence between the electrodes effect, can make significant contribution to anti-flooding.