Wide area damping controller(WADC) is usually utilized to damp interarea low frequency oscillation in power system. However, conventional WADC design method neglects the influence of signal transmission delay and damp...Wide area damping controller(WADC) is usually utilized to damp interarea low frequency oscillation in power system. However, conventional WADC design method neglects the influence of signal transmission delay and damping performance of WADC designed by the conventional method may deteriorate or even has no effect when signal transmission delay is beyond delay margin, an index that denotes delay endurance degree of power system. Therefore, a new design method for WADC under the condition of expected damping factor and required signal transmission delay is presented in this work. An improved delay margin with less conservatism is derived by adopting a new Lyapunov-Krasovskii function and more compact bounding technique on the derivative of Lyapunov-Krasovskii functional. The improved delay margin, which constructs the correlation of damping factor and signal transmission delay, can be used to design WADC. WADC designed by the proposed method can ensure that power system satisfies expected damping factor when WADC input signal is delayed within delay margin. Satisfactory test results demonstrate the effectiveness of the proposed method.展开更多
A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power system...A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station.展开更多
Integration of renewable energy sources(RES)with a conventional power system has a detrimental effect on interarea oscillation.Most popular RESs are solar photovoltaic(PV)and wind energy conversion systems(WECS).Both ...Integration of renewable energy sources(RES)with a conventional power system has a detrimental effect on interarea oscillation.Most popular RESs are solar photovoltaic(PV)and wind energy conversion systems(WECS).Both solar PV power generation and WECS are integrated with power systems using a power electronic converter.Increasing the amount of RES generation lead towards reduction of system damping,which leads towards inter-area oscillation.Also,the intermittent behavior of a RES reduces the effectiveness of damping controllers.A dynamic controller based wide area damping controller(WADC)is proposed in this paper to increase small signal stability of a RES integrated power system.The WADC is designed for contemplating delay in a communication channel,communication failure and saturation.An anti-windup compensator is developed to overcome the effect of actuator saturation.However,the gain of the anti-windup compensator is calculated using LyapunovKrasovskii functional(LKF)in terms of linear matrix inequality(LMI).The actuator considered in this paper is a unified power flow controller(UPFC).Efficacy of PV and wind power integration on power system is also observed.The efficacy of the developed dynamic controller is verified using IEEE 39 bus and 68 bus power system.展开更多
In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of...In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of transmission lines, increase wear and tear on network components, increase line losses etc. This paper is to maintain the stability of system by damping inter-area oscillations. Implementation of new equipment consists of high power electronics based technologies such as FACTs and proper controller design has become an essential to provide better damping performance than Power System Stabilizer (PSS). With development of Wide Area Measurement System (WAMS), remote signals have become as feedback signals to design Wide Area Damping Controller (WADC) for FACTs devices. In this work, POD is applied to both SVC and SSSC. Simulation studies are carried out in Power System Analysis Toolbox (PSAT) environment to evaluate the effectiveness of the FACTs controller in a large area power system. Results show that extensive analysis of FACTs controller for improving stability of system.展开更多
This paper presents a novel composite wide area control of a DFIG wind energy system which combines the Robust Exact Differentiator(RED)and Discontinuous Integral(DI)control to damp out inter-area oscillations.RED gen...This paper presents a novel composite wide area control of a DFIG wind energy system which combines the Robust Exact Differentiator(RED)and Discontinuous Integral(DI)control to damp out inter-area oscillations.RED generates the real-time differentiation of a relative speed signal in a noisy environment while DI control,an extension to a twisting algorithm and PID control,develops a continuous control signal and hence reduces chattering.The proposed control is robust to disturbances and can enhance the overall stability of the system.The proposed composite sliding mode control is evaluated using a modified benchmark two-area power system model with wind energy integration.Simulation results under various operating scenarios show the efficacy of the proposed approach.展开更多
由2篇论文组成的系列论文旨在研究广域闭环控制系统(wide-area closed-loop control system,WACS)中时延的特性。在系列论文第1篇的研究基础上,首先提出估计实际WACS中闭环时延的方法,综合考虑通信时延与操作时延,提出正态分布模型以估...由2篇论文组成的系列论文旨在研究广域闭环控制系统(wide-area closed-loop control system,WACS)中时延的特性。在系列论文第1篇的研究基础上,首先提出估计实际WACS中闭环时延的方法,综合考虑通信时延与操作时延,提出正态分布模型以估计实际系统中的闭环时延分布,并给出确定正态分布模型参数的方法。然后介绍在实际WACS中实测闭环时延的时标对比法。最后,在专用通道与非专用通道的条件下,实测贵州电网WACS中的闭环时延,并将实测结果与使用正态分布模型的估计结果进行对比分析,验证了所提出的正态分布估计模型。该文对时延的分析及测试结果对广域闭环控制的研究及应用具有参考价值。展开更多
基金Project(51007042) supported by the National Natural Science Foundation of China
文摘Wide area damping controller(WADC) is usually utilized to damp interarea low frequency oscillation in power system. However, conventional WADC design method neglects the influence of signal transmission delay and damping performance of WADC designed by the conventional method may deteriorate or even has no effect when signal transmission delay is beyond delay margin, an index that denotes delay endurance degree of power system. Therefore, a new design method for WADC under the condition of expected damping factor and required signal transmission delay is presented in this work. An improved delay margin with less conservatism is derived by adopting a new Lyapunov-Krasovskii function and more compact bounding technique on the derivative of Lyapunov-Krasovskii functional. The improved delay margin, which constructs the correlation of damping factor and signal transmission delay, can be used to design WADC. WADC designed by the proposed method can ensure that power system satisfies expected damping factor when WADC input signal is delayed within delay margin. Satisfactory test results demonstrate the effectiveness of the proposed method.
文摘A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station.
文摘Integration of renewable energy sources(RES)with a conventional power system has a detrimental effect on interarea oscillation.Most popular RESs are solar photovoltaic(PV)and wind energy conversion systems(WECS).Both solar PV power generation and WECS are integrated with power systems using a power electronic converter.Increasing the amount of RES generation lead towards reduction of system damping,which leads towards inter-area oscillation.Also,the intermittent behavior of a RES reduces the effectiveness of damping controllers.A dynamic controller based wide area damping controller(WADC)is proposed in this paper to increase small signal stability of a RES integrated power system.The WADC is designed for contemplating delay in a communication channel,communication failure and saturation.An anti-windup compensator is developed to overcome the effect of actuator saturation.However,the gain of the anti-windup compensator is calculated using LyapunovKrasovskii functional(LKF)in terms of linear matrix inequality(LMI).The actuator considered in this paper is a unified power flow controller(UPFC).Efficacy of PV and wind power integration on power system is also observed.The efficacy of the developed dynamic controller is verified using IEEE 39 bus and 68 bus power system.
文摘In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of transmission lines, increase wear and tear on network components, increase line losses etc. This paper is to maintain the stability of system by damping inter-area oscillations. Implementation of new equipment consists of high power electronics based technologies such as FACTs and proper controller design has become an essential to provide better damping performance than Power System Stabilizer (PSS). With development of Wide Area Measurement System (WAMS), remote signals have become as feedback signals to design Wide Area Damping Controller (WADC) for FACTs devices. In this work, POD is applied to both SVC and SSSC. Simulation studies are carried out in Power System Analysis Toolbox (PSAT) environment to evaluate the effectiveness of the FACTs controller in a large area power system. Results show that extensive analysis of FACTs controller for improving stability of system.
文摘This paper presents a novel composite wide area control of a DFIG wind energy system which combines the Robust Exact Differentiator(RED)and Discontinuous Integral(DI)control to damp out inter-area oscillations.RED generates the real-time differentiation of a relative speed signal in a noisy environment while DI control,an extension to a twisting algorithm and PID control,develops a continuous control signal and hence reduces chattering.The proposed control is robust to disturbances and can enhance the overall stability of the system.The proposed composite sliding mode control is evaluated using a modified benchmark two-area power system model with wind energy integration.Simulation results under various operating scenarios show the efficacy of the proposed approach.
文摘由2篇论文组成的系列论文旨在研究广域闭环控制系统(wide-area closed-loop control system,WACS)中时延的特性。在系列论文第1篇的研究基础上,首先提出估计实际WACS中闭环时延的方法,综合考虑通信时延与操作时延,提出正态分布模型以估计实际系统中的闭环时延分布,并给出确定正态分布模型参数的方法。然后介绍在实际WACS中实测闭环时延的时标对比法。最后,在专用通道与非专用通道的条件下,实测贵州电网WACS中的闭环时延,并将实测结果与使用正态分布模型的估计结果进行对比分析,验证了所提出的正态分布估计模型。该文对时延的分析及测试结果对广域闭环控制的研究及应用具有参考价值。