A design of a solar-wind electrical hybrid system to supply space heating requirements for a 1,200 m^2 residential building in Amman-Jordan was implemented. The building heating requirements were estimated from existi...A design of a solar-wind electrical hybrid system to supply space heating requirements for a 1,200 m^2 residential building in Amman-Jordan was implemented. The building heating requirements were estimated from existing heating building data based on traditional heating design already adopted by engineering firms in Jordan. The traditional heating load was transferred into electrical load to be supplied by hybrid system. The hybrid system consists of a 75 kW vertical axis windmill and 140 solar modules. Because of the high cost of land in residential buildings, the hybrid system is to be installed on the building roof. The hybrid system and the conventional systems' cost were found to be compatible in four years period when oil prices reach $100 per barrel. As the international price of oil rises above $100 per barrel, the proposed hybrid system becomes more economical than the already existing hot water heating system.展开更多
Wind-solar hybrid systems are employed extensively due to certain advantages. However, two problems exist in their application: the PV modules operate at high temperatures, particularly during summer, and low wind pow...Wind-solar hybrid systems are employed extensively due to certain advantages. However, two problems exist in their application: the PV modules operate at high temperatures, particularly during summer, and low wind power cannot be utilized. To solve these two problems, a novel hybrid system is designed based on PV/thermal systems, in which PV modules are cooled with fans driven by a wind turbine. This paper studies the practicability of the novel hybrid system. First, the electrical performance of the wind turbine is compared using a fan and battery load,respectively. Second, different types and numbers of fans are tested to obtain the largest air volume. Third, the height of the air duct on the back of the PV module is optimized and the cooling effect is studied. Results show that a 24 V DC fan is more appropriate for the novel system than a 12 V DC fan, as it provides a greater air volume, and with a switch wind speed of 3.0 m/s the power of PV module shows a maximum increase of 8.0%.展开更多
For the bi-power system adopted widely in future armored vehicles,a hybrid power generator with dual stator-winding was proposed.Its structure and working principle were analyzed first,and its main parameters were det...For the bi-power system adopted widely in future armored vehicles,a hybrid power generator with dual stator-winding was proposed.Its structure and working principle were analyzed first,and its main parameters were determined and verified according to the power requirements.The system's mathematical model was established,and a decoupled control method was put forward on the basis of the instantaneous reactive power theory.For the voltage building-up,a voltage control strategy was designed on the basis of mixed reactive power compensation to implement stabilized 28V and 270V outputs simultaneously.The simulation results show that the stabilization accuracy and disturbance rejection ability of the system are improved much more than other ordinary generators.展开更多
Energy is critical to the economic growth and social development of any country. Indigenous energy resources need to be developed to the optimum level to minimize dependence on imported fuels, subject to resolving eco...Energy is critical to the economic growth and social development of any country. Indigenous energy resources need to be developed to the optimum level to minimize dependence on imported fuels, subject to resolving economic, environmental and social constraints. This led to an increase in research and development as well as investments in the renewable energy industry in search of ways to meet the energy demand and to reduce the dependency on fossil fuels. Wind and solar energy are becoming popular owing to the abundance, availability and ease of harnessing the energy for electrical power generation. This paper focuses on an integrated hybrid renewable energy system consisting of wind and solar energies. Many parts of Libya have the potential for the development of economic power generation, so maps locations were used to identify where both wind and solar potentials are high. The focal point of this paper is to describe and evaluate a wind-solar hybrid power generation system for a selected location. Grid-tied power generation systems make use of solar PV or wind turbines to produce electricity and supply the load by connecting to the grid. In this study, the HOMER (Hybrid Optimization Model for Electric Renewable) computer modeling software was used to model the power system, its physical behavior and its life cycle cost. Computer modeling software was used to model the power system, its physical behavior and its life cycle cost. The hybrid power system was designed for a building at the University of Al-Marj (MARJU). Through the use of simulations, the installation of ten 100-kW wind turbines and 150-KW solar PV was evaluated.展开更多
Supercharging is the process of supplying air for combustion at a pressure greater than that achieved by natural or atmospheric induction, as applied to internal combustion engines. As a consequence of demonstrated te...Supercharging is the process of supplying air for combustion at a pressure greater than that achieved by natural or atmospheric induction, as applied to internal combustion engines. As a consequence of demonstrated technological, economical and energetic advantages in multiple literature evaluations concerning the large scale wind-compressed air hybrid storage system with gas turbines, the utilization of a hybrid wind-diesel system with compressed air storage (HWDCAS) has been frequently explored. These will mainly have average or small scale application such as the powering of isolated sites. It has been proven in numerous studies that the HWDCAS combined with an additional supercharging of the diesel engines will contribute to the increase of the power and efficiency of the diesel engine, the reduction of both fuel consumption and the emission of greenhouse gases (GHG). This article presents the obtained results from experimental validation of the selected design with an aim to valorize this innovative solution and become trustworthy.展开更多
This paper proposes the most feasible technical and environmentally friendly hybrid power system configuration;a stand-alone hybrid wind-solar energy system with battery storage for a residential area of an Agro-indus...This paper proposes the most feasible technical and environmentally friendly hybrid power system configuration;a stand-alone hybrid wind-solar energy system with battery storage for a residential area of an Agro-industrial Company, Cameroon Development Cooperation (CDC), with headquarters in Bota-Limbe, south west region, Cameroon. The power network of the CDC Bota-Limbe Camp amongst other camps, which accommodates plantation workers, is plagued with challenges such as reliance on grid power which is unreliable, poor power quality which endangers home appliances and a spider webbed transmission system that poses as a threat to the lives of plantation workers. This paper addresses those concerns by designing a modular hybrid solar-wind renewable energy system for the camp. Limbe is a coastal area with proven existence of wind and solar resources. It is expected that the proposed system, if adopted and well implemented, will provide huge opportunities for the CDC in several other locations in Cameroon where there is adequate supply of renewable energy resources.展开更多
This work is a contribution to the study of hybrid systems for converting solar and wind energy into electricity in Burkina Faso. The approach consists of evaluating and analyzing the production of a wind turbine and ...This work is a contribution to the study of hybrid systems for converting solar and wind energy into electricity in Burkina Faso. The approach consists of evaluating and analyzing the production of a wind turbine and a solar field in order to optimize the production of all the technologies. The results obtained made it possible to evaluate the operating performance of the installation and to show the complementarity between the two energy sources with regard to temporary and seasonal variations in resources. During nighttime periods or periods of low sunlight, the wind turbine is a good alternative to energy storage by batteries, the output of the wind turbine can be up to 853.76 W. It was also a question of proposing solutions for optimizing the hybrid system through the automation of the hybrid charge regulator. A minimum height of 30 m above the ground has been chosen as the optimum height for the wind turbine.展开更多
If two or more renewable energy sources are available in the same region, their complementary can be advantageous in a hybrid power system. Three indices are defined in this work for assessing the complementarity of s...If two or more renewable energy sources are available in the same region, their complementary can be advantageous in a hybrid power system. Three indices are defined in this work for assessing the complementarity of solar and wind resources for energy production. Based on existing data of solar radiation and wind speed, these complementarity indices were calculated and represented in the form of maps for the state of Rio Grande do Sul, in southern Brazil. The results found suggest that there are some areas of the state where the use of hybrid wind-solar power systems could be more effective than single photovoltaic or wind systems.展开更多
This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and e...This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and energy storage system (ESS). The reliability of the MG system is modeled based on the loss of power supply probability (SPSP). For optimization, an enhanced Genetic Algorithm (GA) is used to minimize the total cost of the system over a 20-year period, while satisfying some reliability and operation constraints. A case study addressing optimal sizing of an off-grid hybrid microgrid in Nigeria is discussed. The result is compared with results obtained from the Brute Force and standard GA methods.展开更多
Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total sys...Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total system power generation and the minimum ten-day joint output. To effectively optimize the multi-objective model, a new algorithm named non-dominated sorting culture differential evolution algorithm(NSCDE) is proposed. The feasibility of NSCDE was verified through several well-known benchmark problems. It was then applied to the Jinping Wind-Solar-Hydro complementary power generation system. The results demonstrate that NSCDE can provide decision makers a series of optimized scheduling schemes.展开更多
Although transmission systems are able to cover most of the areas in many countries, there are still some isolated areas such as rural counties and remote desert lands where grid power cannot be accessed. Therefore, a...Although transmission systems are able to cover most of the areas in many countries, there are still some isolated areas such as rural counties and remote desert lands where grid power cannot be accessed. Therefore, a reliable and economical power supply scheme is required to solve the problem. One of them combines wind/solar power generation with the support of storage system. This paper is to give an overview of the optimization methodologies about the wind/solar stand-alone system supported by storage systems or integrating with other renewable or conventional power generation sources. It is shown that continued research and optimization methodology in this area are still in great need for performance improvement.展开更多
This paper applies new maximum-power-point tracking (MPPT) algorithm to a hybrid renewable energy system that combines both Wind-Turbine Generator (WTG) and Solar Photovoltaic (PV) Module (SPVM). In this paper...This paper applies new maximum-power-point tracking (MPPT) algorithm to a hybrid renewable energy system that combines both Wind-Turbine Generator (WTG) and Solar Photovoltaic (PV) Module (SPVM). In this paper, the WTG is a direct-drive system and includes wind turbine, three-phase permanent magnet synchronous generator, three-phase full bridge rectifier, and buck-bust converter, while the SPVM consist of solar PV modules, buck converter, maximum power tracking system for both systems, and load. Several methods are applied to obtain maximum performances, the appropriate and most effective method is called gradient-approximation method for WTG approach, because it enables the generator to operate at variable wind speeds. Furthermore MPPT also is used to optimized the achieved energy generated by solar PV modules.Matlab / Simulink approach is used to simulate, discuss, and optimized the generated power by varying the duty cycle of the converters, and tip speed ratio of the WTG system.展开更多
The paper deals with automatic reactive power control of an isolated wind-diesel hybrid power system. The power is generated by diesel engine and wind turbine as prime movers with electrical power conversion by perman...The paper deals with automatic reactive power control of an isolated wind-diesel hybrid power system. The power is generated by diesel engine and wind turbine as prime movers with electrical power conversion by permanent-magnet synchronous generator (PMSG) and permanent-magnet induction generator (PMIG) respectively. The mathematical model of the system developed is based on reactive power flow equations. The paper investigates the dynamic performance of the hybrid system for 1% step increase in reactive power load with 1% step increase in input wind power.展开更多
The paper presents the next generation of power energy systems using solar- and wind-energy systems for the country of Jordan. Presently with the oil prices are on the rise, the cost of electrical power production is ...The paper presents the next generation of power energy systems using solar- and wind-energy systems for the country of Jordan. Presently with the oil prices are on the rise, the cost of electrical power production is very high. The opportunity of a large wind and solar hybrid power production is being explored. Sights are chosen to produce electricity using the wind in the Mountains in Northern Jordan and the sun in the Eastern Desert. It is found that the cost of windmill farm to produce 100 - 150 MW is US$290 million while solar power station to produce 100 MW costs US$560 million. The electrical power costs US$0.02/kWh for the wind power and US$0.077 for the solar power. The feasibility for using wind and solar energies is now when the price oil reaches US$ 100.00 per barrel. The paper also discusses different power electronics circuits and control methods to link the renewable energy to the national grid. This paper also looks at some of the modern power electronics converters and electrical generators, which have improved significantly solar and wind energy technologies.展开更多
In Mongolia,the numbers of herders who own more than 1,000 herds have been increasing year by year.Some of the herder families are operating small agricultural factories as well.The appropriate power supply systems ar...In Mongolia,the numbers of herders who own more than 1,000 herds have been increasing year by year.Some of the herder families are operating small agricultural factories as well.The appropriate power supply systems are not being developed yet in their farms.At the farms,mostly 4-10 herder families work together and the monthly power consumption of one farm reaches to 11.8-14.9 kWh.Currently,the gasoline,diesel,solar and wind power are being used as a source of energy production.In addition,the small-scale CHP(Combined Heat and Power)system is not introduced to the farms for their sustainable operation.There are abundant biomass resources in the rural area of Mongolia.In this paper,we conduct experimental studies on biomass gasification system and suggest small-scale CHP system for rural farms in Mongolia.展开更多
Energy harvesting plays a crucial role in modern society.In the past years,solar energy,owing to its renewable,green,and infinite attributes,has attracted increasing attention across a broad range of applications from...Energy harvesting plays a crucial role in modern society.In the past years,solar energy,owing to its renewable,green,and infinite attributes,has attracted increasing attention across a broad range of applications from small-scale wearable electronics to large-scale energy powering.However,the utility of solar cells in providing a stable power supply for vari-ous electrical appliances in practical applications is restricted by weather conditions.To address this issue,researchers have made many efforts to integrate solar cells with other types of energy harvesters,thus developing hybrid energy har-vesters(HEHs),which can harvest energy from the ambient environment via different working mechanisms.In this re-view,four categories of energy harvesters including solar cells,triboelectric nanogenerators(TENGs),piezoelectric nanogenerators(PENGs),and thermoelectric generators(TEGs)are introduced.In addition,we systematically summar-ize the recent progress in solar cell-based hybrid energy harvesters(SCHEHs)with a focus on their structure designs and the corresponding applications.Three hybridization designs through unique combinations of TENG,PENG,and TEG with solar cells are elaborated in detail.Finally,the main challenges and perspectives for the future development of SCHEHs are discussed.展开更多
Figure of merit analysis is a general methodology used to evaluate whether a hybrid power plant could produce more power than two stand-alone power plants. In this paper, the assessment methodology using figure of mer...Figure of merit analysis is a general methodology used to evaluate whether a hybrid power plant could produce more power than two stand-alone power plants. In this paper, the assessment methodology using figure of merit analysis was re-examined for a hybrid solar-geothermal power plant. A new definition of the figure of merit was introduced specifically for a solar boosted geothermal plant to include both the technical and economic factors. The new definition was then applied in a case study of a hypothetical demonstration hybrid solar-geothermal power plant in Australia. The power plant was considered to have a typical net power output of 2.2 MW with a solar energy fraction of 27%. The analysis was performed to compare the power output and capital cost of the hybrid plant with the state-of-the-art (SoA) and existing stand-alone solar and geothermal plants. Based on the new definition, the hybrid plant was found to generally outperform the two existing stand-alone plants. Moreover, at an ambient temperature of 5 °C, the hybrid plant was found to outperform the SoA stand-alone plants when the geothermal temperature was greater than 150 °C. For geothermal temperature of 180 °C on the other hand, the hybrid plant outperformed the SoA stand-alone plants at ambient temperatures lower than 33 °C.展开更多
Hybrid utilization of renewable energy is one of effective method which can solve the problem that unstable of renewable energy so as not to substitute traditional fossil energy. As the typical renewable energy, solar...Hybrid utilization of renewable energy is one of effective method which can solve the problem that unstable of renewable energy so as not to substitute traditional fossil energy. As the typical renewable energy, solar energy and wind energy are in the van of renewable energy utilization. With the large scale utilization of solar and wind energy in the world, constructing large scale solar power plant in the large scale wind farm can make the most of ground resource combining the wind energy with solar energy. Feasibility of constructing large scale solar power plant in the large scale wind farm was analyzed in this paper, and come to a conclusion that constructing large scale solar power plant in the large scale wind farm can not also achieved the goal of mutual support of resource advantages and economizing money but also improved significantly the seasonal mismatch by combining solar with wind.展开更多
On Mauritania’s northern coast, wind and solar resources are abundant and must be used effectively. These resources have the potential to completely or partially replace the existing or projected diesel generators. T...On Mauritania’s northern coast, wind and solar resources are abundant and must be used effectively. These resources have the potential to completely or partially replace the existing or projected diesel generators. The main objective of this case study is to study the possibility of using a hybrid system (HS) of the type (diesel, wind and storage). The most important part of this case study intended for this area will be to add the solar in a first phase and then the incorporation of an interconnection with the nearby network in a second phase. This interconnection will be secured by mean of medium voltage lines of 33 kV, where the nearest point is located 35 km away. Indeed, the study of the optimization model is carried out through Homer, which was developed by National Renewable Energy Laboratory [NREL]. Thus, it should be noted that the HS is analyzed on the basis of costs ($/kW) and price ($/kWh) and greenhouse gas emissions. Therefore, in order to achieve these techno-economic optimization objectives, this paper introduces a sensitivity analysis that has been proposed to determine the effect of costs on each HS configuration. In the end, HSs are needed for maximum use of renewable resources at the studied site for an uninterrupted power supply.展开更多
For domestic consumers in the rural areas of northern Kenya, as in other developing countries, the typical source of electrical supply is diesel generators. However, diesel generators are associated with both CO2 emis...For domestic consumers in the rural areas of northern Kenya, as in other developing countries, the typical source of electrical supply is diesel generators. However, diesel generators are associated with both CO2 emissions, which adversely affect the environment and increase diesel fuel prices, which inflate the prices of consumer goods. The Kenya government has taken steps towards addressing this issue by proposing The Hybrid Mini-Grid Project, which involves the installation of 3 MW of wind and solar energy systems in facilities with existing diesel generators. However, this project has not yet been implemented. As a contribution to this effort, this study proposes, simulates and analyzes five different configurations of hybrid energy systems incorporating wind energy, solar energy and battery storage to replace the stand-alone diesel power systems servicing six remote villages in northern Kenya. If implemented, the systems proposed here would reduce Kenya’s dependency on diesel fuel, leading to reductions in its carbon footprint. This analysis confirms the feasibility of these hybrid systems with many configurations being profitable. A Multi-Attribute Trade-Off Analysis is employed to determine the best hybrid system configuration option that would reduce diesel fuel consumption and jointly minimize CO2 emissions and net present cost. This analysis determined that a wind-diesel-battery configuration consisting of two 500 kW turbines, 1200 kW diesel capacity and 95,040 Ah battery capacity is the best option to replace a 3200 kW stand-alone diesel system providing electricity to a village with a peak demand of 839 kW. It has the potential to reduce diesel fuel consumption and CO2 emissions by up to 98.8%.展开更多
文摘A design of a solar-wind electrical hybrid system to supply space heating requirements for a 1,200 m^2 residential building in Amman-Jordan was implemented. The building heating requirements were estimated from existing heating building data based on traditional heating design already adopted by engineering firms in Jordan. The traditional heating load was transferred into electrical load to be supplied by hybrid system. The hybrid system consists of a 75 kW vertical axis windmill and 140 solar modules. Because of the high cost of land in residential buildings, the hybrid system is to be installed on the building roof. The hybrid system and the conventional systems' cost were found to be compatible in four years period when oil prices reach $100 per barrel. As the international price of oil rises above $100 per barrel, the proposed hybrid system becomes more economical than the already existing hot water heating system.
文摘Wind-solar hybrid systems are employed extensively due to certain advantages. However, two problems exist in their application: the PV modules operate at high temperatures, particularly during summer, and low wind power cannot be utilized. To solve these two problems, a novel hybrid system is designed based on PV/thermal systems, in which PV modules are cooled with fans driven by a wind turbine. This paper studies the practicability of the novel hybrid system. First, the electrical performance of the wind turbine is compared using a fan and battery load,respectively. Second, different types and numbers of fans are tested to obtain the largest air volume. Third, the height of the air duct on the back of the PV module is optimized and the cooling effect is studied. Results show that a 24 V DC fan is more appropriate for the novel system than a 12 V DC fan, as it provides a greater air volume, and with a switch wind speed of 3.0 m/s the power of PV module shows a maximum increase of 8.0%.
文摘For the bi-power system adopted widely in future armored vehicles,a hybrid power generator with dual stator-winding was proposed.Its structure and working principle were analyzed first,and its main parameters were determined and verified according to the power requirements.The system's mathematical model was established,and a decoupled control method was put forward on the basis of the instantaneous reactive power theory.For the voltage building-up,a voltage control strategy was designed on the basis of mixed reactive power compensation to implement stabilized 28V and 270V outputs simultaneously.The simulation results show that the stabilization accuracy and disturbance rejection ability of the system are improved much more than other ordinary generators.
文摘Energy is critical to the economic growth and social development of any country. Indigenous energy resources need to be developed to the optimum level to minimize dependence on imported fuels, subject to resolving economic, environmental and social constraints. This led to an increase in research and development as well as investments in the renewable energy industry in search of ways to meet the energy demand and to reduce the dependency on fossil fuels. Wind and solar energy are becoming popular owing to the abundance, availability and ease of harnessing the energy for electrical power generation. This paper focuses on an integrated hybrid renewable energy system consisting of wind and solar energies. Many parts of Libya have the potential for the development of economic power generation, so maps locations were used to identify where both wind and solar potentials are high. The focal point of this paper is to describe and evaluate a wind-solar hybrid power generation system for a selected location. Grid-tied power generation systems make use of solar PV or wind turbines to produce electricity and supply the load by connecting to the grid. In this study, the HOMER (Hybrid Optimization Model for Electric Renewable) computer modeling software was used to model the power system, its physical behavior and its life cycle cost. Computer modeling software was used to model the power system, its physical behavior and its life cycle cost. The hybrid power system was designed for a building at the University of Al-Marj (MARJU). Through the use of simulations, the installation of ten 100-kW wind turbines and 150-KW solar PV was evaluated.
文摘Supercharging is the process of supplying air for combustion at a pressure greater than that achieved by natural or atmospheric induction, as applied to internal combustion engines. As a consequence of demonstrated technological, economical and energetic advantages in multiple literature evaluations concerning the large scale wind-compressed air hybrid storage system with gas turbines, the utilization of a hybrid wind-diesel system with compressed air storage (HWDCAS) has been frequently explored. These will mainly have average or small scale application such as the powering of isolated sites. It has been proven in numerous studies that the HWDCAS combined with an additional supercharging of the diesel engines will contribute to the increase of the power and efficiency of the diesel engine, the reduction of both fuel consumption and the emission of greenhouse gases (GHG). This article presents the obtained results from experimental validation of the selected design with an aim to valorize this innovative solution and become trustworthy.
文摘This paper proposes the most feasible technical and environmentally friendly hybrid power system configuration;a stand-alone hybrid wind-solar energy system with battery storage for a residential area of an Agro-industrial Company, Cameroon Development Cooperation (CDC), with headquarters in Bota-Limbe, south west region, Cameroon. The power network of the CDC Bota-Limbe Camp amongst other camps, which accommodates plantation workers, is plagued with challenges such as reliance on grid power which is unreliable, poor power quality which endangers home appliances and a spider webbed transmission system that poses as a threat to the lives of plantation workers. This paper addresses those concerns by designing a modular hybrid solar-wind renewable energy system for the camp. Limbe is a coastal area with proven existence of wind and solar resources. It is expected that the proposed system, if adopted and well implemented, will provide huge opportunities for the CDC in several other locations in Cameroon where there is adequate supply of renewable energy resources.
文摘This work is a contribution to the study of hybrid systems for converting solar and wind energy into electricity in Burkina Faso. The approach consists of evaluating and analyzing the production of a wind turbine and a solar field in order to optimize the production of all the technologies. The results obtained made it possible to evaluate the operating performance of the installation and to show the complementarity between the two energy sources with regard to temporary and seasonal variations in resources. During nighttime periods or periods of low sunlight, the wind turbine is a good alternative to energy storage by batteries, the output of the wind turbine can be up to 853.76 W. It was also a question of proposing solutions for optimizing the hybrid system through the automation of the hybrid charge regulator. A minimum height of 30 m above the ground has been chosen as the optimum height for the wind turbine.
文摘If two or more renewable energy sources are available in the same region, their complementary can be advantageous in a hybrid power system. Three indices are defined in this work for assessing the complementarity of solar and wind resources for energy production. Based on existing data of solar radiation and wind speed, these complementarity indices were calculated and represented in the form of maps for the state of Rio Grande do Sul, in southern Brazil. The results found suggest that there are some areas of the state where the use of hybrid wind-solar power systems could be more effective than single photovoltaic or wind systems.
文摘This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and energy storage system (ESS). The reliability of the MG system is modeled based on the loss of power supply probability (SPSP). For optimization, an enhanced Genetic Algorithm (GA) is used to minimize the total cost of the system over a 20-year period, while satisfying some reliability and operation constraints. A case study addressing optimal sizing of an off-grid hybrid microgrid in Nigeria is discussed. The result is compared with results obtained from the Brute Force and standard GA methods.
基金supported by the National Key R&D Program of China (2016YFC0402209)the Major Research Plan of the National Natural Science Foundation of China (No. 91647114)
文摘Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total system power generation and the minimum ten-day joint output. To effectively optimize the multi-objective model, a new algorithm named non-dominated sorting culture differential evolution algorithm(NSCDE) is proposed. The feasibility of NSCDE was verified through several well-known benchmark problems. It was then applied to the Jinping Wind-Solar-Hydro complementary power generation system. The results demonstrate that NSCDE can provide decision makers a series of optimized scheduling schemes.
文摘Although transmission systems are able to cover most of the areas in many countries, there are still some isolated areas such as rural counties and remote desert lands where grid power cannot be accessed. Therefore, a reliable and economical power supply scheme is required to solve the problem. One of them combines wind/solar power generation with the support of storage system. This paper is to give an overview of the optimization methodologies about the wind/solar stand-alone system supported by storage systems or integrating with other renewable or conventional power generation sources. It is shown that continued research and optimization methodology in this area are still in great need for performance improvement.
文摘This paper applies new maximum-power-point tracking (MPPT) algorithm to a hybrid renewable energy system that combines both Wind-Turbine Generator (WTG) and Solar Photovoltaic (PV) Module (SPVM). In this paper, the WTG is a direct-drive system and includes wind turbine, three-phase permanent magnet synchronous generator, three-phase full bridge rectifier, and buck-bust converter, while the SPVM consist of solar PV modules, buck converter, maximum power tracking system for both systems, and load. Several methods are applied to obtain maximum performances, the appropriate and most effective method is called gradient-approximation method for WTG approach, because it enables the generator to operate at variable wind speeds. Furthermore MPPT also is used to optimized the achieved energy generated by solar PV modules.Matlab / Simulink approach is used to simulate, discuss, and optimized the generated power by varying the duty cycle of the converters, and tip speed ratio of the WTG system.
文摘The paper deals with automatic reactive power control of an isolated wind-diesel hybrid power system. The power is generated by diesel engine and wind turbine as prime movers with electrical power conversion by permanent-magnet synchronous generator (PMSG) and permanent-magnet induction generator (PMIG) respectively. The mathematical model of the system developed is based on reactive power flow equations. The paper investigates the dynamic performance of the hybrid system for 1% step increase in reactive power load with 1% step increase in input wind power.
文摘The paper presents the next generation of power energy systems using solar- and wind-energy systems for the country of Jordan. Presently with the oil prices are on the rise, the cost of electrical power production is very high. The opportunity of a large wind and solar hybrid power production is being explored. Sights are chosen to produce electricity using the wind in the Mountains in Northern Jordan and the sun in the Eastern Desert. It is found that the cost of windmill farm to produce 100 - 150 MW is US$290 million while solar power station to produce 100 MW costs US$560 million. The electrical power costs US$0.02/kWh for the wind power and US$0.077 for the solar power. The feasibility for using wind and solar energies is now when the price oil reaches US$ 100.00 per barrel. The paper also discusses different power electronics circuits and control methods to link the renewable energy to the national grid. This paper also looks at some of the modern power electronics converters and electrical generators, which have improved significantly solar and wind energy technologies.
文摘In Mongolia,the numbers of herders who own more than 1,000 herds have been increasing year by year.Some of the herder families are operating small agricultural factories as well.The appropriate power supply systems are not being developed yet in their farms.At the farms,mostly 4-10 herder families work together and the monthly power consumption of one farm reaches to 11.8-14.9 kWh.Currently,the gasoline,diesel,solar and wind power are being used as a source of energy production.In addition,the small-scale CHP(Combined Heat and Power)system is not introduced to the farms for their sustainable operation.There are abundant biomass resources in the rural area of Mongolia.In this paper,we conduct experimental studies on biomass gasification system and suggest small-scale CHP system for rural farms in Mongolia.
基金We are grateful for financial support from the Deutsche Forschungsgemeinschaft(DFG,German Research Foundation)via Germany’s Excellence Strategy-EXC 2089/1-390776260(e-conversion)and via the International Research Training Group 2022 the Alberta/Technical University of Munich International Graduate School for Environmentally Responsible Functional Materials(ATUMS),TUM.
文摘Energy harvesting plays a crucial role in modern society.In the past years,solar energy,owing to its renewable,green,and infinite attributes,has attracted increasing attention across a broad range of applications from small-scale wearable electronics to large-scale energy powering.However,the utility of solar cells in providing a stable power supply for vari-ous electrical appliances in practical applications is restricted by weather conditions.To address this issue,researchers have made many efforts to integrate solar cells with other types of energy harvesters,thus developing hybrid energy har-vesters(HEHs),which can harvest energy from the ambient environment via different working mechanisms.In this re-view,four categories of energy harvesters including solar cells,triboelectric nanogenerators(TENGs),piezoelectric nanogenerators(PENGs),and thermoelectric generators(TEGs)are introduced.In addition,we systematically summar-ize the recent progress in solar cell-based hybrid energy harvesters(SCHEHs)with a focus on their structure designs and the corresponding applications.Three hybridization designs through unique combinations of TENG,PENG,and TEG with solar cells are elaborated in detail.Finally,the main challenges and perspectives for the future development of SCHEHs are discussed.
文摘Figure of merit analysis is a general methodology used to evaluate whether a hybrid power plant could produce more power than two stand-alone power plants. In this paper, the assessment methodology using figure of merit analysis was re-examined for a hybrid solar-geothermal power plant. A new definition of the figure of merit was introduced specifically for a solar boosted geothermal plant to include both the technical and economic factors. The new definition was then applied in a case study of a hypothetical demonstration hybrid solar-geothermal power plant in Australia. The power plant was considered to have a typical net power output of 2.2 MW with a solar energy fraction of 27%. The analysis was performed to compare the power output and capital cost of the hybrid plant with the state-of-the-art (SoA) and existing stand-alone solar and geothermal plants. Based on the new definition, the hybrid plant was found to generally outperform the two existing stand-alone plants. Moreover, at an ambient temperature of 5 °C, the hybrid plant was found to outperform the SoA stand-alone plants when the geothermal temperature was greater than 150 °C. For geothermal temperature of 180 °C on the other hand, the hybrid plant outperformed the SoA stand-alone plants at ambient temperatures lower than 33 °C.
文摘Hybrid utilization of renewable energy is one of effective method which can solve the problem that unstable of renewable energy so as not to substitute traditional fossil energy. As the typical renewable energy, solar energy and wind energy are in the van of renewable energy utilization. With the large scale utilization of solar and wind energy in the world, constructing large scale solar power plant in the large scale wind farm can make the most of ground resource combining the wind energy with solar energy. Feasibility of constructing large scale solar power plant in the large scale wind farm was analyzed in this paper, and come to a conclusion that constructing large scale solar power plant in the large scale wind farm can not also achieved the goal of mutual support of resource advantages and economizing money but also improved significantly the seasonal mismatch by combining solar with wind.
文摘On Mauritania’s northern coast, wind and solar resources are abundant and must be used effectively. These resources have the potential to completely or partially replace the existing or projected diesel generators. The main objective of this case study is to study the possibility of using a hybrid system (HS) of the type (diesel, wind and storage). The most important part of this case study intended for this area will be to add the solar in a first phase and then the incorporation of an interconnection with the nearby network in a second phase. This interconnection will be secured by mean of medium voltage lines of 33 kV, where the nearest point is located 35 km away. Indeed, the study of the optimization model is carried out through Homer, which was developed by National Renewable Energy Laboratory [NREL]. Thus, it should be noted that the HS is analyzed on the basis of costs ($/kW) and price ($/kWh) and greenhouse gas emissions. Therefore, in order to achieve these techno-economic optimization objectives, this paper introduces a sensitivity analysis that has been proposed to determine the effect of costs on each HS configuration. In the end, HSs are needed for maximum use of renewable resources at the studied site for an uninterrupted power supply.
文摘For domestic consumers in the rural areas of northern Kenya, as in other developing countries, the typical source of electrical supply is diesel generators. However, diesel generators are associated with both CO2 emissions, which adversely affect the environment and increase diesel fuel prices, which inflate the prices of consumer goods. The Kenya government has taken steps towards addressing this issue by proposing The Hybrid Mini-Grid Project, which involves the installation of 3 MW of wind and solar energy systems in facilities with existing diesel generators. However, this project has not yet been implemented. As a contribution to this effort, this study proposes, simulates and analyzes five different configurations of hybrid energy systems incorporating wind energy, solar energy and battery storage to replace the stand-alone diesel power systems servicing six remote villages in northern Kenya. If implemented, the systems proposed here would reduce Kenya’s dependency on diesel fuel, leading to reductions in its carbon footprint. This analysis confirms the feasibility of these hybrid systems with many configurations being profitable. A Multi-Attribute Trade-Off Analysis is employed to determine the best hybrid system configuration option that would reduce diesel fuel consumption and jointly minimize CO2 emissions and net present cost. This analysis determined that a wind-diesel-battery configuration consisting of two 500 kW turbines, 1200 kW diesel capacity and 95,040 Ah battery capacity is the best option to replace a 3200 kW stand-alone diesel system providing electricity to a village with a peak demand of 839 kW. It has the potential to reduce diesel fuel consumption and CO2 emissions by up to 98.8%.