This paper deals with implementation of Sinusoidal Pulse-Width-Modulation (SPWM) for a single-phase hybrid power filter generator for Photovoltaic (PV) and wind grid applications. Using policy iteration algorithm, an ...This paper deals with implementation of Sinusoidal Pulse-Width-Modulation (SPWM) for a single-phase hybrid power filter generator for Photovoltaic (PV) and wind grid applications. Using policy iteration algorithm, an improved variable step-size perturbation and observation algorithm is contrived and it is implemented proficiently using a hard-ware description language (VHDL) (Very High Speed Integrated Circuit Hardware Description Language). Subsequently, the new generated grid source supplements the existing grid power in rural houses during its cut off or restricted supply period. The software is used for generating SPWM modulation integrated with a solar-power & wind power grid system which is implemented on the Spartan 3 FPGA. The proposed algorithm performs as a conventional controller in terms of tracking speed and mitigating fluctuation output power in steady state operation which is shown in the experimental results with a commercial PV array and HPW (Height Weight Proportional) show. Simulation results demonstrate the validity with load of the proposed algorithm.展开更多
This study aims to provide electricity to a remote village in the Union of Comoros that has been affected by energy problems for over 40 years. The study uses a 50 kW diesel generator, a 10 kW wind turbine, 1500 kW ph...This study aims to provide electricity to a remote village in the Union of Comoros that has been affected by energy problems for over 40 years. The study uses a 50 kW diesel generator, a 10 kW wind turbine, 1500 kW photovoltaic solar panels, a converter, and storage batteries as the proposed sources. The main objective of this study is to conduct a detailed analysis and optimization of a hybrid diesel and renewable energy system to meet the electricity demand of a remote area village of 800 to 1500 inhabitants located in the north of Ngazidja Island in Comoros. The study uses the Hybrid Optimization Model for Electric Renewable (HOMER) Pro to conduct simulations and optimize the analysis using meteorological data from Comoros. The results show that hybrid combination is more profitable in terms of margin on economic cost with a less expensive investment. With a diesel cost of $1/L, an average wind speed of 5.09 m/s and a solar irradiation value of 6.14 kWh/m<sup>2</sup>/day, the system works well with a proportion of renewable energy production of 99.44% with an emission quantity of 1311.407 kg/year. 99.2% of the production comes from renewable sources with an estimated energy surplus of 2,125,344 kWh/year with the cost of electricity (COE) estimated at $0.18/kWh, presenting a cost-effective alternative compared to current market rates. These results present better optimization of the used hybrid energy system, satisfying energy demand and reducing the environmental impact.展开更多
Wind-solar hybrid systems are employed extensively due to certain advantages. However, two problems exist in their application: the PV modules operate at high temperatures, particularly during summer, and low wind pow...Wind-solar hybrid systems are employed extensively due to certain advantages. However, two problems exist in their application: the PV modules operate at high temperatures, particularly during summer, and low wind power cannot be utilized. To solve these two problems, a novel hybrid system is designed based on PV/thermal systems, in which PV modules are cooled with fans driven by a wind turbine. This paper studies the practicability of the novel hybrid system. First, the electrical performance of the wind turbine is compared using a fan and battery load,respectively. Second, different types and numbers of fans are tested to obtain the largest air volume. Third, the height of the air duct on the back of the PV module is optimized and the cooling effect is studied. Results show that a 24 V DC fan is more appropriate for the novel system than a 12 V DC fan, as it provides a greater air volume, and with a switch wind speed of 3.0 m/s the power of PV module shows a maximum increase of 8.0%.展开更多
This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and e...This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and energy storage system (ESS). The reliability of the MG system is modeled based on the loss of power supply probability (SPSP). For optimization, an enhanced Genetic Algorithm (GA) is used to minimize the total cost of the system over a 20-year period, while satisfying some reliability and operation constraints. A case study addressing optimal sizing of an off-grid hybrid microgrid in Nigeria is discussed. The result is compared with results obtained from the Brute Force and standard GA methods.展开更多
This work is a contribution to the study of hybrid systems for converting solar and wind energy into electricity in Burkina Faso. The approach consists of evaluating and analyzing the production of a wind turbine and ...This work is a contribution to the study of hybrid systems for converting solar and wind energy into electricity in Burkina Faso. The approach consists of evaluating and analyzing the production of a wind turbine and a solar field in order to optimize the production of all the technologies. The results obtained made it possible to evaluate the operating performance of the installation and to show the complementarity between the two energy sources with regard to temporary and seasonal variations in resources. During nighttime periods or periods of low sunlight, the wind turbine is a good alternative to energy storage by batteries, the output of the wind turbine can be up to 853.76 W. It was also a question of proposing solutions for optimizing the hybrid system through the automation of the hybrid charge regulator. A minimum height of 30 m above the ground has been chosen as the optimum height for the wind turbine.展开更多
文摘This paper deals with implementation of Sinusoidal Pulse-Width-Modulation (SPWM) for a single-phase hybrid power filter generator for Photovoltaic (PV) and wind grid applications. Using policy iteration algorithm, an improved variable step-size perturbation and observation algorithm is contrived and it is implemented proficiently using a hard-ware description language (VHDL) (Very High Speed Integrated Circuit Hardware Description Language). Subsequently, the new generated grid source supplements the existing grid power in rural houses during its cut off or restricted supply period. The software is used for generating SPWM modulation integrated with a solar-power & wind power grid system which is implemented on the Spartan 3 FPGA. The proposed algorithm performs as a conventional controller in terms of tracking speed and mitigating fluctuation output power in steady state operation which is shown in the experimental results with a commercial PV array and HPW (Height Weight Proportional) show. Simulation results demonstrate the validity with load of the proposed algorithm.
文摘This study aims to provide electricity to a remote village in the Union of Comoros that has been affected by energy problems for over 40 years. The study uses a 50 kW diesel generator, a 10 kW wind turbine, 1500 kW photovoltaic solar panels, a converter, and storage batteries as the proposed sources. The main objective of this study is to conduct a detailed analysis and optimization of a hybrid diesel and renewable energy system to meet the electricity demand of a remote area village of 800 to 1500 inhabitants located in the north of Ngazidja Island in Comoros. The study uses the Hybrid Optimization Model for Electric Renewable (HOMER) Pro to conduct simulations and optimize the analysis using meteorological data from Comoros. The results show that hybrid combination is more profitable in terms of margin on economic cost with a less expensive investment. With a diesel cost of $1/L, an average wind speed of 5.09 m/s and a solar irradiation value of 6.14 kWh/m<sup>2</sup>/day, the system works well with a proportion of renewable energy production of 99.44% with an emission quantity of 1311.407 kg/year. 99.2% of the production comes from renewable sources with an estimated energy surplus of 2,125,344 kWh/year with the cost of electricity (COE) estimated at $0.18/kWh, presenting a cost-effective alternative compared to current market rates. These results present better optimization of the used hybrid energy system, satisfying energy demand and reducing the environmental impact.
文摘Wind-solar hybrid systems are employed extensively due to certain advantages. However, two problems exist in their application: the PV modules operate at high temperatures, particularly during summer, and low wind power cannot be utilized. To solve these two problems, a novel hybrid system is designed based on PV/thermal systems, in which PV modules are cooled with fans driven by a wind turbine. This paper studies the practicability of the novel hybrid system. First, the electrical performance of the wind turbine is compared using a fan and battery load,respectively. Second, different types and numbers of fans are tested to obtain the largest air volume. Third, the height of the air duct on the back of the PV module is optimized and the cooling effect is studied. Results show that a 24 V DC fan is more appropriate for the novel system than a 12 V DC fan, as it provides a greater air volume, and with a switch wind speed of 3.0 m/s the power of PV module shows a maximum increase of 8.0%.
文摘This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and energy storage system (ESS). The reliability of the MG system is modeled based on the loss of power supply probability (SPSP). For optimization, an enhanced Genetic Algorithm (GA) is used to minimize the total cost of the system over a 20-year period, while satisfying some reliability and operation constraints. A case study addressing optimal sizing of an off-grid hybrid microgrid in Nigeria is discussed. The result is compared with results obtained from the Brute Force and standard GA methods.
文摘This work is a contribution to the study of hybrid systems for converting solar and wind energy into electricity in Burkina Faso. The approach consists of evaluating and analyzing the production of a wind turbine and a solar field in order to optimize the production of all the technologies. The results obtained made it possible to evaluate the operating performance of the installation and to show the complementarity between the two energy sources with regard to temporary and seasonal variations in resources. During nighttime periods or periods of low sunlight, the wind turbine is a good alternative to energy storage by batteries, the output of the wind turbine can be up to 853.76 W. It was also a question of proposing solutions for optimizing the hybrid system through the automation of the hybrid charge regulator. A minimum height of 30 m above the ground has been chosen as the optimum height for the wind turbine.