期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Diagnosis of Disc Space Variation Fault Degree of Transformer Winding Based on K-Nearest Neighbor Algorithm
1
作者 Song Wang Fei Xie +3 位作者 Fengye Yang Shengxuan Qiu Chuang Liu Tong Li 《Energy Engineering》 EI 2023年第10期2273-2285,共13页
Winding is one of themost important components in power transformers.Ensuring the health state of the winding is of great importance to the stable operation of the power system.To efficiently and accurately diagnose t... Winding is one of themost important components in power transformers.Ensuring the health state of the winding is of great importance to the stable operation of the power system.To efficiently and accurately diagnose the disc space variation(DSV)fault degree of transformer winding,this paper presents a diagnostic method of winding fault based on the K-Nearest Neighbor(KNN)algorithmand the frequency response analysis(FRA)method.First,a laboratory winding model is used,and DSV faults with four different degrees are achieved by changing disc space of the discs in the winding.Then,a series of FRA tests are conducted to obtain the FRA results and set up the FRA dataset.Second,ten different numerical indices are utilized to obtain features of FRA curves of faulted winding.Third,the 10-fold cross-validation method is employed to determine the optimal k-value of KNN.In addition,to improve the accuracy of the KNN model,a comparative analysis is made between the accuracy of the KNN algorithm and k-value under four distance functions.After getting the most appropriate distance metric and kvalue,the fault classificationmodel based on theKNN and FRA is constructed and it is used to classify the degrees of DSV faults.The identification accuracy rate of the proposed model is up to 98.30%.Finally,the performance of the model is presented by comparing with the support vector machine(SVM),SVM optimized by the particle swarmoptimization(PSO-SVM)method,and randomforest(RF).The results show that the diagnosis accuracy of the proposed model is the highest and the model can be used to accurately diagnose the DSV fault degrees of the winding. 展开更多
关键词 transformer winding frequency response analysis(FRA)method K-Nearest Neighbor(KNN) disc space variation(DSV)
下载PDF
Influence of Capacitive Effects on Transformer Windings
2
作者 Mathurin Gogom Rodolphe Gomba Desire Lilonga-Boyenga 《Energy and Power Engineering》 2021年第2期67-80,共14页
For years, capacitive effects have been the subject of research [1] and [2]. The capacitive effects are discrete capacitors that appear between active conductors of power lines and between them with the ground plane, ... For years, capacitive effects have been the subject of research [1] and [2]. The capacitive effects are discrete capacitors that appear between active conductors of power lines and between them with the ground plane, generating capacitive reactive power to the network [1] and [2]. Indeed, it must be noted that these effects affect the windings of the transformer when the coupling is in star or triangle. This study is conducted to show that capacitive effects affect transformer windings differently when coupling is in stars or triangles. The results obtained are interesting and can be exploited in electrical transmission networks to ensure a long lifespan of transformers. 展开更多
关键词 Capacitive Effects Discrete Capacitors Geometry of Conductors transformers windings
下载PDF
Analytical Solution for Evaluation of Voltage Surge Distribution along Transformer Windings through the Method of Residues
3
作者 Sergio H. L. Cabral Savio Leandro Bertoli 《Journal of Energy and Power Engineering》 2014年第6期1099-1103,共5页
Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation conce... Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation concerns. In consequence, studies based on analytical approach to basic studies of correlated problems have become even more important because they form the very basis of knowledge that is necessary to every transformer designer in view of taking all the advantages of computational analyses. On the other hand, one of the most important basic studies consists in the evaluation of voltage surge distribution along transformer windings for which the method of separation of variables has been extensively used thanks to some simplifying assumptions. With this aim, authors have developed and previously published works that show the applicability of an alternative and useful analytical method that is the method of the residues, which requires no simplification to be assumed. In this work, another important step is taken towards proofing the total applicability of this promising method that is through a practical problem. A comparison to the numerical method TLM (transmission line method) is also performed and concordance with TLM and experimental data confirms the proposal of the method of residues can be also applicable to several others problems of electromagnetism. 展开更多
关键词 transformer winding method of residues electrical transient voltage surge.
下载PDF
A Multi Input Multi Output Converter for Hybrid Energy Systems
4
作者 T. Baldwin Immanuel A. Suresh M. R. Rashmi 《Circuits and Systems》 2016年第6期771-778,共8页
Multi input and multi output converters are becoming popular because they are cost effective and compact. This paper proposes a multi input multi output converter for Grid-Solar power integration for uninterrupted pow... Multi input and multi output converters are becoming popular because they are cost effective and compact. This paper proposes a multi input multi output converter for Grid-Solar power integration for uninterrupted power supply. The proposed converter uses four winding transformer with two primary windings and two secondary windings. The grid supply is connected to the first winding of transformer through rectifier-inverter for controlled power transfer. The solar energy is inverted and applied to the second winding of primary. Two output ports are considered. The circuit is designed to get zero current switching during turn-off and zero voltage switching during turn-on to alleviate the switching losses. The simulation results for the proposed configuration are presented in this paper. 展开更多
关键词 Multi Input/Multi Output Converters ZCS/ZVS Grid-Solar Power Integration Multi winding transformer
下载PDF
Research on a New Fiber-Optic Axial Pressure Sensor of Transformer Winding Based on Fiber Bragg Grating 被引量:4
5
作者 Yuan LIU Lianqing LI +2 位作者 Lin ZHAO Jiqiang WANG Tongyu LIU 《Photonic Sensors》 SCIE EI CAS CSCD 2017年第4期365-371,共7页
Based on the principle of the fiber Bragg grating, a new type of fiber-optic pressure sensor for axial force measurement of transformer winding is designed, which is designed with the structure of bending plate beam, ... Based on the principle of the fiber Bragg grating, a new type of fiber-optic pressure sensor for axial force measurement of transformer winding is designed, which is designed with the structure of bending plate beam, the optimization of the packaging process, and material of the sensor. Through the calibration experiment to calibrate the sensor, the field test results of the Taikai transformer factory show that the sensitivity of the sensor is 0.133 pm/kPa and the repeatability error is 2.7%FS. The data of the fiber-optic pressure sensor in different positions maintain consistent and repeatable, which can meet the requirement of the real-time monitoring of the axial force of transformer winding. 展开更多
关键词 transformer winding pressure sensor fiber Bragg grating (FBG) axial force
原文传递
Improvement of admittance measurements for modeling of an ungrounded reactor/transformer winding 被引量:1
6
作者 Tarik Abdulahovic Torbjorn Thiringer 《International Journal of Modeling, Simulation, and Scientific Computing》 EI 2016年第3期18-35,共18页
In this paper,a model of an ungrounded reactor winding is developed for transient voltage studies.The developed model is a black box model where the state-space model is developed using the directly measured admittanc... In this paper,a model of an ungrounded reactor winding is developed for transient voltage studies.The developed model is a black box model where the state-space model is developed using the directly measured admittance matrix of the reactor winding.Furthermore,an improved model is developed,where the accuracy of the admittance matrix measurement set in the low frequency band is obtained indirectly using an additional set of voltage ratio measurements.When the measured admittances are low,the accuracy of the diagonal admittance vectors in the low frequency band is low as well.However,the accuracy at low frequencies obtained using the indirect measurements is improved at nodes with the lowest admittances.In this paper,different approaches for indirect measurements are studied and the most accurate method is identified considering the physical structure of windings. 展开更多
关键词 transformer windings impedance measurement transient analysis
原文传递
Listing of Longyuan,Transformation of Guodian
7
作者 Zhang Na and Dai Zhemin Wang Ying 《Electricity》 2010年第3期-,共3页
China Longyuan Power was listed on the main board of Hong Kong Stock Exchange in 2009.The successful listing proved the correctness and timeliness of China Guodian's strategy of "leading enterprises to transf... China Longyuan Power was listed on the main board of Hong Kong Stock Exchange in 2009.The successful listing proved the correctness and timeliness of China Guodian's strategy of "leading enterprises to transformation by exploring new energy resources energetically." 展开更多
关键词 list transformation wind power new energy
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部