A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlineari...A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures.展开更多
In this paper, the impact of limiting thermostat on the rupture event occuring in Fuel-Oil burner fuel pre-heaters' resistant (heat generating) wires is inspected numerically. Gaseous fuel content in the pipeline h...In this paper, the impact of limiting thermostat on the rupture event occuring in Fuel-Oil burner fuel pre-heaters' resistant (heat generating) wires is inspected numerically. Gaseous fuel content in the pipeline has also been issued as a possibility. Heater's inner temperature distributions have been simulated by an in-house MATrix LABoratory (MATLAB) script in order to understand the resistant wire exposure to high temperatures by numerous scenarios. It is concluded that the effect of fuel flowrate is not a major effect on the wires' fate because of the limiting thermostat co-working. The main difference between the calculations is the effect of thermostat cut off function. The numerical simulations enlightened the dominant effect of thermostat sensing delay, so the overheating event. Intolerable delay results with a quick drop in the thermal efficiency and an increased possibility on wire rupture due to overheating which means a burner malfunction. Referring to the first numerical simulation results, a distributed and reduced heat flux was implemented with the same fluid and thermodynamic properties on a revised pre-heater model with an increased heater plate. The increment, thus the reduction on the heat flux of the ribbon wires has been noted as the key for safe operation.展开更多
基金Research Fund of Chinese State Grid Company (No.SGKJ[2007]413)
文摘A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures.
文摘In this paper, the impact of limiting thermostat on the rupture event occuring in Fuel-Oil burner fuel pre-heaters' resistant (heat generating) wires is inspected numerically. Gaseous fuel content in the pipeline has also been issued as a possibility. Heater's inner temperature distributions have been simulated by an in-house MATrix LABoratory (MATLAB) script in order to understand the resistant wire exposure to high temperatures by numerous scenarios. It is concluded that the effect of fuel flowrate is not a major effect on the wires' fate because of the limiting thermostat co-working. The main difference between the calculations is the effect of thermostat cut off function. The numerical simulations enlightened the dominant effect of thermostat sensing delay, so the overheating event. Intolerable delay results with a quick drop in the thermal efficiency and an increased possibility on wire rupture due to overheating which means a burner malfunction. Referring to the first numerical simulation results, a distributed and reduced heat flux was implemented with the same fluid and thermodynamic properties on a revised pre-heater model with an increased heater plate. The increment, thus the reduction on the heat flux of the ribbon wires has been noted as the key for safe operation.