A 2.4GHz ASK transmitter suitable for a low power wireless capsule endoscope system is presented. A mixer-based frequency up-conversion transmitter architecture is employed to achieve a high data rate. A pseudodiffere...A 2.4GHz ASK transmitter suitable for a low power wireless capsule endoscope system is presented. A mixer-based frequency up-conversion transmitter architecture is employed to achieve a high data rate. A pseudodifferential stacked class-A power amplifier using the current reuse technique is proposed to save power. The transmitter mainly includes two parts: a 20MHz ASK modulator based on a constant amplitude phase lock loop (PLL) and a direct up-conversion RF circuit. This design, implemented in a TSMC 0.25μm CMOS process, achieves a - 23. 217dBm output power with a data rate of 1Mbps and dissipates 3.17mA of current with a single 2.5V power supply.展开更多
The wireless capsule endoscope,as a small electronic device,has conquered some limitations of traditional wired diagnosing tools,such as the uncomfortableness of the cables for the patient and the inability to examine...The wireless capsule endoscope,as a small electronic device,has conquered some limitations of traditional wired diagnosing tools,such as the uncomfortableness of the cables for the patient and the inability to examine the very convoluted small intestine section.However,this technique is still encountering a lot of practical challenges and is looking for feasible improvements.This work investigates the RF performance of the wireless capsule endoscope system by studying the electromagnetic(EM) wave propagation within the human body.A wireless capsule endoscopy transmission channel model is constructed to serve the purpose of investigating signal attenuations according to the relative position between the transmitter and the receiver.Within 300-500 MHz,the S_(21) results are regular and do not display any sudden changes,which allows a suitable expression to be derived for S_(21) in terms of frequency and offset.The results provide useful information for capsule localization.展开更多
Wireless capsule endoscopes (WCEs) have been used widely to detect abnormalities inside regions of the small intestine that are not accessible when using traditional endoscopy techniques. However, an experienced clini...Wireless capsule endoscopes (WCEs) have been used widely to detect abnormalities inside regions of the small intestine that are not accessible when using traditional endoscopy techniques. However, an experienced clinician must spend an average of 2 hours to view and analyze the approximately 60,000 images produced during one examination. Therefore, developing a computeraided system for processing WCE images is crucial. This paper proposes a novel method used for detecting bleeding and ulcers in WCE images. This approach involves using color features to determine the status of the small intestine. The experimental results revealed that the proposed scheme is promising in detecting bleeding and ulcer regions.展开更多
BACKGROUND Meckel’s diverticulum (MD) occurs predominantly in chil-dren and adolescents. It is rarely diagnosed in adults. Preoperative diagnosis is diffcult due to low sensitivity of the radiological imaging studi...BACKGROUND Meckel’s diverticulum (MD) occurs predominantly in chil-dren and adolescents. It is rarely diagnosed in adults. Preoperative diagnosis is diffcult due to low sensitivity of the radiological imaging studies. The role of video capsule endoscopy (VCE) in the diagnosis of MD is unknown, and the endoscopic patterns are not defned. We will describe four of our cases of MD evaluated with VCE and make a review of the literature focusing on the endoscopic characteristics.CASE SUMMARYWe present four cases of MD confirmed by surgery. They were all adult males with ages going from 18 to 50 years, referred to our service from 2004 to 2018, due to obscure gastrointestinal bleeding (OGIB). TheyGarcía-Compeán D et al . Merckel’s diverticulum diagnosis by VCEhad a history of 1 mo to 10 years of overt and occult bleeding episodes. Laboratory blood test showed an iron-deficiency anemia from 4 to 9 g/dL of hemoglo-bin that required multiple hospitalizations and blood transfusions in all cases. Repeated upper digestive endoscopies and colonoscopies were negative. Small bowel was examined with VCE, which revealed double lumen images in all cases, one with polyps and three with circumferential ulcers in the diverticulum. However, based on VCE findings, preoperative diagnosis of MD was suggested only in two patients. Capsule was retain-ed in one patient, which was recovered with surgery. The anatomopathological report revealed ulcerated ectopic gastric mucosa in all cases.CONCLUSIONVCE is useful for the diagnosis of MD. However, endo-scopic characteristics must be recognized in order to establish preoperative diagnosis.展开更多
A smart image sensor was developed which integrates a digital pixel image sensor array with an image processor, designed for wireless endoscope capsules. The camera-on-a-chip architecture and its on-chip functionality...A smart image sensor was developed which integrates a digital pixel image sensor array with an image processor, designed for wireless endoscope capsules. The camera-on-a-chip architecture and its on-chip functionality facilitate the design of the packaging and power consumption of the integrated capsule. The power reduction techniques were carried out at both the architectural and circuit level. Gray coding and power gating in the sensor array to eliminate almost 50% of the switch activity on the data bus and more than 99% of the power dissipation in each pixel at a transmitting rate of 2 frames per second. Filtering and compression in the processor reduces the data transmission by more than 2/3. A parallel fully pipelined architecture with a dedicated clock management scheme was implemented in the JPEG-LS engine to reduce the power consumption by 15.7%. The smart sensor has been implemented in 0.18 μm CMOS technology.展开更多
文摘A 2.4GHz ASK transmitter suitable for a low power wireless capsule endoscope system is presented. A mixer-based frequency up-conversion transmitter architecture is employed to achieve a high data rate. A pseudodifferential stacked class-A power amplifier using the current reuse technique is proposed to save power. The transmitter mainly includes two parts: a 20MHz ASK modulator based on a constant amplitude phase lock loop (PLL) and a direct up-conversion RF circuit. This design, implemented in a TSMC 0.25μm CMOS process, achieves a - 23. 217dBm output power with a data rate of 1Mbps and dissipates 3.17mA of current with a single 2.5V power supply.
基金Project (BK20131183) supported by the Natural Science Foundation of Jiangsu Province,ChinaProjects (RDF-14-03-24,RDF-14-02-48) supported by Research Development Fund of Xi’an Jiaotong-Liverpool University,China
文摘The wireless capsule endoscope,as a small electronic device,has conquered some limitations of traditional wired diagnosing tools,such as the uncomfortableness of the cables for the patient and the inability to examine the very convoluted small intestine section.However,this technique is still encountering a lot of practical challenges and is looking for feasible improvements.This work investigates the RF performance of the wireless capsule endoscope system by studying the electromagnetic(EM) wave propagation within the human body.A wireless capsule endoscopy transmission channel model is constructed to serve the purpose of investigating signal attenuations according to the relative position between the transmitter and the receiver.Within 300-500 MHz,the S_(21) results are regular and do not display any sudden changes,which allows a suitable expression to be derived for S_(21) in terms of frequency and offset.The results provide useful information for capsule localization.
文摘Wireless capsule endoscopes (WCEs) have been used widely to detect abnormalities inside regions of the small intestine that are not accessible when using traditional endoscopy techniques. However, an experienced clinician must spend an average of 2 hours to view and analyze the approximately 60,000 images produced during one examination. Therefore, developing a computeraided system for processing WCE images is crucial. This paper proposes a novel method used for detecting bleeding and ulcers in WCE images. This approach involves using color features to determine the status of the small intestine. The experimental results revealed that the proposed scheme is promising in detecting bleeding and ulcer regions.
文摘BACKGROUND Meckel’s diverticulum (MD) occurs predominantly in chil-dren and adolescents. It is rarely diagnosed in adults. Preoperative diagnosis is diffcult due to low sensitivity of the radiological imaging studies. The role of video capsule endoscopy (VCE) in the diagnosis of MD is unknown, and the endoscopic patterns are not defned. We will describe four of our cases of MD evaluated with VCE and make a review of the literature focusing on the endoscopic characteristics.CASE SUMMARYWe present four cases of MD confirmed by surgery. They were all adult males with ages going from 18 to 50 years, referred to our service from 2004 to 2018, due to obscure gastrointestinal bleeding (OGIB). TheyGarcía-Compeán D et al . Merckel’s diverticulum diagnosis by VCEhad a history of 1 mo to 10 years of overt and occult bleeding episodes. Laboratory blood test showed an iron-deficiency anemia from 4 to 9 g/dL of hemoglo-bin that required multiple hospitalizations and blood transfusions in all cases. Repeated upper digestive endoscopies and colonoscopies were negative. Small bowel was examined with VCE, which revealed double lumen images in all cases, one with polyps and three with circumferential ulcers in the diverticulum. However, based on VCE findings, preoperative diagnosis of MD was suggested only in two patients. Capsule was retain-ed in one patient, which was recovered with surgery. The anatomopathological report revealed ulcerated ectopic gastric mucosa in all cases.CONCLUSIONVCE is useful for the diagnosis of MD. However, endo-scopic characteristics must be recognized in order to establish preoperative diagnosis.
文摘A smart image sensor was developed which integrates a digital pixel image sensor array with an image processor, designed for wireless endoscope capsules. The camera-on-a-chip architecture and its on-chip functionality facilitate the design of the packaging and power consumption of the integrated capsule. The power reduction techniques were carried out at both the architectural and circuit level. Gray coding and power gating in the sensor array to eliminate almost 50% of the switch activity on the data bus and more than 99% of the power dissipation in each pixel at a transmitting rate of 2 frames per second. Filtering and compression in the processor reduces the data transmission by more than 2/3. A parallel fully pipelined architecture with a dedicated clock management scheme was implemented in the JPEG-LS engine to reduce the power consumption by 15.7%. The smart sensor has been implemented in 0.18 μm CMOS technology.