期刊文献+
共找到10,361篇文章
< 1 2 250 >
每页显示 20 50 100
Anisotropy of Trabecular Bone from Ultra-Distal Radius Digital X-Ray Imaging: Effects on Bone Mineral Density and Age
1
作者 Jian-Feng Chen 《Open Journal of Radiology》 2024年第1期14-23,共10页
Background: When applied to trabecular bone X-ray images, the anisotropic properties of trabeculae located at ultra-distal radius were investigated by using the trabecular bone scores (TBS) calculated along directions... Background: When applied to trabecular bone X-ray images, the anisotropic properties of trabeculae located at ultra-distal radius were investigated by using the trabecular bone scores (TBS) calculated along directions parallel and perpendicular to the forearm. Methodology: Data from more than two hundred subjects were studied retrospectively. A DXA (GE Lunar Prodigy) scan of the forearm was performed on each subject to measure the bone mineral density (BMD) value at the location of ultra-distal radius, and an X-ray digital image of the same forearm was taken on the same day. The values of trabecular bone score along the direction perpendicular to the forearm, TBS<sub>x</sub>, and along the direction parallel to the forearm, TBS<sub>y</sub>, were calculated respectively. The statistics of TBS<sub>x</sub> and TBS<sub>y</sub> were calculated, and the anisotropy of the trabecular bone, which was defined as the ratio of TBS<sub>y</sub> to TBS<sub>x</sub> and changed with subjects’ BMD and age, was reported and analyzed. Results: The results show that the correlation coefficient between TBS<sub>x</sub> and TBS<sub>y</sub> was 0.72 (p BMD and age was reported. The results showed that decreased trabecular bone anisotropy was associated with deceased BMD and increased age in the subject group. Conclusions: This study shows that decreased trabecular bone anisotropy was associated with decreased BMD and increased age. 展开更多
关键词 ANISOTROPY Trabecular Bone Score Bone Mineral Density Ultra-Distal Radius Digital x-ray image
下载PDF
Electromagnetic scattering and imaging simulation of extremely large-scale sea-ship scene based on GPU parallel technology
2
作者 Cheng-Wei Zhang Zhi-Qin Zhao +2 位作者 Wei Yang Li-Lai Zhou Hai-Yu Zhu 《Journal of Electronic Science and Technology》 EI CAS CSCD 2024年第2期16-23,共8页
Aiming to solve the bottleneck problem of electromagnetic scattering simulation in the scenes of extremely large-scale seas and ships,a high-frequency method by using graphics processing unit(GPU)parallel acceleration... Aiming to solve the bottleneck problem of electromagnetic scattering simulation in the scenes of extremely large-scale seas and ships,a high-frequency method by using graphics processing unit(GPU)parallel acceleration technique is proposed.For the implementation of different electromagnetic methods of physical optics(PO),shooting and bouncing ray(SBR),and physical theory of diffraction(PTD),a parallel computing scheme based on the CPU-GPU parallel computing scheme is realized to balance computing tasks.Finally,a multi-GPU framework is further proposed to solve the computational difficulty caused by the massive number of ray tubes in the ray tracing process.By using the established simulation platform,signals of ships at different seas are simulated and their images are achieved as well.It is shown that the higher sea states degrade the averaged peak signal-to-noise ratio(PSNR)of radar image. 展开更多
关键词 Multi graphics processing unit Radar imaging Sea-ship Shooting and bouncing rays
下载PDF
M^(3)Res-Transformer:新冠肺炎胸部X-ray图像识别模型
3
作者 周涛 刘赟璨 +3 位作者 侯森宝 常晓玉 叶鑫宇 陆惠玲 《电子学报》 EI CAS CSCD 北大核心 2024年第2期589-601,共13页
新冠肺炎(COVID-19)自爆发以来严重影响人类生命健康,近年来残差神经网络广泛应用于COVID-19识别任务中,辅助医生快速地诊断COVID-19患者,但是COVID-19图像病变区域形状复杂、大小不一,与周围组织的边界模糊,导致网络难以提取有效特征.... 新冠肺炎(COVID-19)自爆发以来严重影响人类生命健康,近年来残差神经网络广泛应用于COVID-19识别任务中,辅助医生快速地诊断COVID-19患者,但是COVID-19图像病变区域形状复杂、大小不一,与周围组织的边界模糊,导致网络难以提取有效特征.本文针对上述问题,提出一种M^(3)Res-Transformer的新冠肺炎胸部X-ray图像识别模型,采用Res-Transformer作为模型的主干网络,结合ResNet和ViT,有效地整合局部病变特征和全局特征;设计混合残差注意力模块(mixed residual attention Module,mraM),同时考虑通道和空间位置的相互依赖性,增强网络的特征表达能力;为了增大感受野,提取多尺度特征,通过叠加具有不同扩张率的扩张卷积构造多尺度扩张残差模块(multiscale dilated residual Module,mdrM),根据不同层次特征尺度的差异,使用3个逐渐收缩尺度的mdrM进行多尺度特征提取;提出上下文交叉感知模块(contextual cross-awareness Module,ccaM),使用深层特征中的语义信息来引导浅层特征,然后将浅层特征中的空间信息嵌入深层特征中,采用交叉加权注意力机制高效聚合深层和浅层特征,获得更丰富的上下文信息.为了验证本文所提模型的有效性,在新冠肺炎胸部X-ray图像数据集上进行实验,与先进的CNN分类模型、融合不同注意力机制的ResNet50模型、基于Transformer的分类模型对比以及消融实验.结果表明,本文所提模型的Acc、Pre、Rec、F1-Score与Spe指标分别为96.33%、96.36%、96.33%、96.35%与96.26%,在COVID-19胸部X-ray图像识别任务中有效提升了识别精度,并通过可视化方法对其进行进一步验证,为COVID-19的辅助诊断提供重要的参考价值. 展开更多
关键词 COVID-19 胸部x-ray图像 残差神经网络 vision transformer 注意力机制
下载PDF
ZnSb/Ti_(3)C_(2)T_(x)MXene van der Waals heterojunction for flexible near-infrared photodetector arrays
4
作者 Chuqiao Hu Ruiqing Chai +2 位作者 Zhongming Wei La Li Guozhen Shen 《Journal of Semiconductors》 EI CAS CSCD 2024年第5期99-105,共7页
Two-dimension(2D)van der Waals heterojunction holds essential promise in achieving high-performance flexible near-infrared(NIR)photodetector.Here,we report the successful fabrication of ZnSb/Ti_(3)C_(2)T_(x)MXene base... Two-dimension(2D)van der Waals heterojunction holds essential promise in achieving high-performance flexible near-infrared(NIR)photodetector.Here,we report the successful fabrication of ZnSb/Ti_(3)C_(2)T_(x)MXene based flexible NIR photodetector array via a facile photolithography technology.The single ZnSb/Ti_(3)C_(2)T_(x)photodetector exhibited a high light-to-dark current ratio of 4.98,fast response/recovery time(2.5/1.3 s)and excellent stability due to the tight connection between 2D ZnSb nanoplates and 2D Ti_(3)C_(2)T_(x)MXene nanoflakes,and the formed 2D van der Waals heterojunction.Thin polyethylene terephthalate(PET)substrate enables the ZnSb/Ti_(3)C_(2)T_(x)photodetector withstand bending such that stable photoelectrical properties with non-obvious change were maintained over 5000 bending cycles.Moreover,the ZnSb/Ti_(3)C_(2)T_(x)photodetectors were integrated into a 26×5 device array,realizing a NIR image sensing application. 展开更多
关键词 ZnSb nanoplates Ti_(3)C_(2)T_(x)Mxene van der Waals heterojunction flexible photodetector image sensing
下载PDF
面向牙齿X-RAY图像分割的牙齿模型
5
作者 周敬策 陆惠玲 《福建电脑》 2024年第1期44-47,共4页
医学图像分割技术为临床诊断和治疗提供关键依据,但传统的图像分割技术易将图像过度分割且分割效果不够精细。为解决这些问题,本文研究采用U-Net网络分割牙齿X-Ray图像,通过合理选择池化操作、激活函数和周期数目,解决牙齿X-Ray图像中... 医学图像分割技术为临床诊断和治疗提供关键依据,但传统的图像分割技术易将图像过度分割且分割效果不够精细。为解决这些问题,本文研究采用U-Net网络分割牙齿X-Ray图像,通过合理选择池化操作、激活函数和周期数目,解决牙齿X-Ray图像中存在的牙齿与周围组织的对比度低、边界模糊、牙齿与背景分布不均、牙齿与组织粘连等问题。实验结果表明,U-Net网络具备有效的牙齿X-Ray图像的分割性能。 展开更多
关键词 牙齿x-ray图像 图像分割 U-Net模型
下载PDF
Comparison of efficacy of lung ultrasound and chest X-ray in diagnosing pulmonary edema and pleural effusion in ICU patients: A single centre, prospective, observational study
6
作者 Kunal Tewari Sumanth Pelluru +5 位作者 Deepak Mishra Nitin Pahuja Akash Ray Mohapatra Jyotsna Sharma Om Bahadur Thapa Manjot Multani 《Open Journal of Anesthesiology》 2024年第3期41-50,共10页
Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LU... Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LUS) in resource-rich ICUs is still under investigation. The present study compares the utility of LUS to that of CXR in identifying pulmonary edema and pleural effusion in ICU patients. In addition, consolidation and pneumothorax were analyzed as secondary outcome measures. Material and Methods This is a prospective, single centric, observational study. Patients admitted in ICU were examined for lung pathologies, using LUS by a trained intensivist;and CXR done within 4 hours of each other. The final diagnosis was ascertained by an independent senior radiologist, based on the complete medical chart including clinical findings and the results of thoracic CT, if available. The results were compared and analyzed. Results Sensitivity, specificity and diagnostic accuracy of LUS was 95%, 94.4%, 94.67% for pleural effusion;and 98.33%, 97.78%, 98.00% for pulmonary edema respectively. Corresponding values with CXR were 48.33%, 76.67%, 65.33% for pleural effusion;and 36.67%, 82.22% and 64.00% for pulmonary edema respectively. Sensitivity, specificity and diagnostic accuracy of LUS was 91.30%, 96.85%, 96.00% for consolidation;and 100.00%, 79.02%, 80.00% for pneumothorax respectively. Corresponding values with CXR were 60.87%, 81.10%, 78.00% for consolidation;and 71.3%, 97.20%, 96.00% for pneumothorax respectively. Conclusion LUS has better diagnostic accuracy in diagnosis of pleural effusion and pulmonary edema when compared with CXR and is thus recommended as an effective alternative for diagnosis of these conditions in acute care settings. Our study recommends that a thoracic CT scan can be avoided in most of such cases. 展开更多
关键词 Chest x ray (CxR) CONSOLIDATION Pulmonary edema Pleural effusion Lung ultrasound (LUS) PNEUMOTHORAx
下载PDF
COVID-19 Detection from Chest X-Ray Images Using Convolutional Neural Network Approach
7
作者 Md. Harun Or Rashid Muzakkir Hossain Minhaz +2 位作者 Ananya Sarker Must. Asma Yasmin Md. Golam An Nihal 《Journal of Computer and Communications》 2023年第5期29-41,共13页
COVID-19 is a respiratory illness caused by the SARS-CoV-2 virus, first identified in 2019. The primary mode of transmission is through respiratory droplets when an infected person coughs or sneezes. Symptoms can rang... COVID-19 is a respiratory illness caused by the SARS-CoV-2 virus, first identified in 2019. The primary mode of transmission is through respiratory droplets when an infected person coughs or sneezes. Symptoms can range from mild to severe, and timely diagnosis is crucial for effective treatment. Chest X-Ray imaging is one diagnostic tool used for COVID-19, and a Convolutional Neural Network (CNN) is a popular technique for image classification. In this study, we proposed a CNN-based approach for detecting COVID-19 in chest X-Ray images. The model was trained on a dataset containing both COVID-19 positive and negative cases and evaluated on a separate test dataset to measure its accuracy. Our results indicated that the CNN approach could accurately detect COVID-19 in chest X-Ray images, with an overall accuracy of 97%. This approach could potentially serve as an early diagnostic tool to reduce the spread of the virus. 展开更多
关键词 COVID-19 Chest x-ray images CNN VIRUS ACCURACY
下载PDF
Latest advances of X-ray imaging and biomedical applications beamline at SSRF 被引量:8
8
作者 谢红兰 邓彪 +10 位作者 杜国浩 付亚楠 陈荣昌 周光照 任玉琦 王玉丹 薛艳玲 彭冠云 和友 郭瀚 肖体乔 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第2期6-21,共16页
On May 6, 2009, the X-ray imaging and biomedical application beamline(BL13W1) at Shanghai Synchrotron Radiation Facility(SSRF) officially opened to users, with 8–72.5 ke V X-rays. The experimental station is equipped... On May 6, 2009, the X-ray imaging and biomedical application beamline(BL13W1) at Shanghai Synchrotron Radiation Facility(SSRF) officially opened to users, with 8–72.5 ke V X-rays. The experimental station is equipped with four sets of X-ray CCD detectors of different pixel size(0.19–24 μm) for on-line phase-contrast imaging and micro-CT imaging with 0.8 μm spatial resolution and 1 ms temporal resolution. An in vivo microCT experiment for a living insect was realized in 4 s. An X-ray fluorescence detector is equipped for X-ray fluorescence mapping imaging and X-ray fluorescence micro-CT imaging with 50 μm spatial resolution. In order to meet different requirements from the users, several experimental methods, such as X-ray spiral micro-CT, Xray local micro-CT, X-ray fast micro-CT, X-ray grating-based differential micro-CT, X-ray fluorescence microCT and X-ray quantitative micro-CT have been developed, and nearly 60 papers related to those developments for this beamline have been published. Moreover, the beamline has realized the remote fast CT reconstruction,providing a great convenience for the users to process experimental data at their offices. As of August 2014,the beamline has offered the user beamtime of(23 145 h), from which 232 user papers have been published,including 151 SCI papers and 55 papers with SCI impact factor > 3. The quantity and quality of the user paper outcome keep a steady increase. Some typical user experimental results are introduced. 展开更多
关键词 x射线成像 生物医学应用 SSRF 光束线 上海同步辐射装置 空间分辨率 荧光检测器 显微CT
下载PDF
Application of Dual-Energy X-Ray Image Detection of Dangerous Goods Based on YOLOv7
9
作者 Baosheng Liu Fei Wang +1 位作者 Ming Gao Lei Zhao 《Journal of Computer and Communications》 2023年第7期208-225,共18页
X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out wo... X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out work has become an inevitable trend. With the development of deep learning, object detection technology is becoming more and more mature, and object detection framework based on convolutional neural networks has been widely used in industrial, medical and military fields. In order to improve the efficiency of security staff, reduce the risk of dangerous goods missed detection. Based on the data collected in X-ray security equipment, this paper uses a method of inserting dangerous goods into an empty package to balance all kinds of dangerous goods data and expand the data set. The high-low energy images are combined using the high-low energy feature fusion method. Finally, the dangerous goods target detection technology based on the YOLOv7 model is used for model training. After the introduction of the above method, the detection accuracy is improved by 6% compared with the direct use of the original data set for detection, and the speed is 93FPS, which can meet the requirements of the online security system, greatly improve the work efficiency of security personnel, and eliminate the security risks caused by missed detection. 展开更多
关键词 x-ray Dangerous Goods Detection High and Low Energy image Fusion ACCURACY Real-Time Detection
下载PDF
Ultra-stable CsPbBr3 Perovskite Nanosheets for X-Ray Imaging Screen 被引量:6
10
作者 Liangling Wang Kaifang Fu +3 位作者 Ruijia Sun Huqiang Lian Xun Hu Yuhai Zhang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2019年第3期263-270,共8页
Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low che... Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low chemical yield hinders their upscale production for practical use.Meanwhile,the labile nature of halide-based perovskite poses a major challenge for long-term storage of perovskite nanocrystals.Herein,we report a green synthesis at room temperature for gram-scale production of CsPbBr3 nanosheets with minimum use of solvent,saving over 95% of the solvent for the unity mass nanocrystal production.The perovskite colloid exhibits record stability upon long-term storage for up to 8 months,preserving a photoluminescence quantum yield of 63% in solid state.Importantly,the colloidal nanosheets show self-assembly behavior upon slow solidification,generating a crack-free thin film in a large area.The uniform film was then demonstrated as an efficient scintillation screen for X-ray imaging.Our findings bring a scalable tool for synthesis of high-quality perovskite nanocrystals,which may inspire the industrial optoelectronic application of large-area perovskite film. 展开更多
关键词 CsPbBr3 PEROVSKITE NANOSHEETS SELF-ASSEMBLY x-ray imaging SCREEN
下载PDF
In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo 被引量:5
11
作者 LI Beilei XU Min +5 位作者 WU Weizhong PENG Guanyun ZHANG Xi PENG Yifeng SHI Hongcheng CHEN Shaoliang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第1期10-14,共5页
Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.V... Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility.Barium sulfate and physiological saline were used as contrast agents for the blood vessels.Blood vessels of <Φ20μm could be detected by replacing resident blood with physiological saline or barium sulfate.An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image.It is demonstrated that selective angiography based on phase contrast X-ray imaging,with a physiological material of low Z elements (such as saline) being the contrast agent,is a viable imaging strategy.Further efforts will be focused on using the technique to image tumor angiogenesis. 展开更多
关键词 x射线成像 相衬成像 微血管 体外 小鼠 上海同步辐射装置 肿瘤血管生成 生理盐水
下载PDF
Manufacturing and testing of X-ray imaging components with high precision 被引量:5
12
作者 HU Jia sheng WU Xü 《光学精密工程》 EI CAS CSCD 北大核心 2005年第5期620-625,共6页
关键词 x光线图像 质量评价 纳米 精度
下载PDF
A fast and adaptive method for automatic weld defect detection in various real-time X-ray imaging systems 被引量:10
13
作者 邵家鑫 都东 +2 位作者 石涵 常保华 郭桂林 《China Welding》 EI CAS 2012年第1期8-12,共5页
A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of me... A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of median filter is used to estimate the weld background. After the weld background is subtracted from the original image, an adaptite threshold segmentation algorithm is proposed to obtain the binary image, and then the morphological close and open operation, labeling algorithm and fids'e alarm eliminating algorithm are applied to pracess the binary image to obtain the defect, ct detection result. At last, a fast realization procedure jbr proposed method is developed. The proposed method is tested in real-time X-ray image,s obtairted in different X-ray imaging sutems. Experiment results show that the proposed method is effective to detect low contrast weld dejects with few .false alarms and is adaptive to various types of real-time X-ray imaging systems. 展开更多
关键词 non-destructive testing real-time x-ray imaging weld defect automatie detection
下载PDF
Applications for Nanoscale X-ray Imaging at High Pressure 被引量:1
14
作者 Wendy L. Mao Yu Lin +1 位作者 Yijin Liu Jin Liu 《Engineering》 SCIE EI 2019年第3期479-489,共11页
Coupling nanoscale transmission X-ray microscopy (nanoTXM) with a diamond anvil cell (DAC) has exciting potential as a powerful three-dimensional probe for non-destructive imaging at high spatial resolution of materia... Coupling nanoscale transmission X-ray microscopy (nanoTXM) with a diamond anvil cell (DAC) has exciting potential as a powerful three-dimensional probe for non-destructive imaging at high spatial resolution of materials under extreme conditions. In this article, we discuss current developments in high-resolution X-ray imaging and its application in high-pressure nanoTXM experiments in a DAC with third-generation synchrotron X-ray sources, including technical considerations for preparing successful measurements. We then present results from a number of recent in situ high-pressure measurements investigating equations of state (EOS) in amorphous or poorly crystalline materials and in pressureinduced phase transitions and electronic changes. These results illustrate the potential this technique holds for addressing a wide range of research areas, ranging from condensed matter physics and solidstate chemistry to materials science and planetary interiors. Future directions for this exciting technique and opportunities to improve its capabilities for broader application in high-pressure science are discussed. 展开更多
关键词 x-ray imaging High PRESSURE DIAMOND ANVIL cell
下载PDF
Development of X-ray dark-field imaging towards clinical application 被引量:1
15
作者 ANDOMasami HASHIMOTOEiko +13 位作者 HASHIZUMEHiroyuki HYODOKazuyuki INOUEHajime ISHIKAWATetsuya KUNISADAToshiyuki MAKSIMENKOAnton PATTANASIRIWISAWAWanwisa RUBENSTEINEdward ROBERSONJoseph SHIMAODaisuke SUGIYAMAHiroshi TAKEDAKen UENOEi WADAHiroshi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2004年第3期129-139,共11页
Review of X-ray dark-field imaging under development is presented. Its goal is its application to clinical diagnosis of organs that have been invisible by the ordinary techniques. In order to clinically visualize tiss... Review of X-ray dark-field imaging under development is presented. Its goal is its application to clinical diagnosis of organs that have been invisible by the ordinary techniques. In order to clinically visualize tissues in detail one needs high contrast and high spatial resolution say ~50 μm. This X-ray optics comprises a Bragg asymmetric monochro-collimator and a Bragg case or a Laue case filter with capability of analyzing angle in a parallel position. Their diffraction index is 4,4,0 and the X-ray energy 35 keV (λ= 0.0354 nm). The filter has 0.6 mm thickness in the Bragg case or 1.075 mm or 2.15 mm thickness in the Laue case. Under this condition only the refracted X-rays from object can transmit through the filter while the beam that may receive absorption and/or phase change will not. Soft tissues at human joints thus taken show high contrast images so that the DFI is promising for clinical diagnosis. Preliminary X-ray absorption images of another clinical candidates of ear bones are also shown. 展开更多
关键词 x射线暗场成像 x射线亮场成像 x射线诊断学 布拉格滤波器 布拉格不对称单色准直仪
下载PDF
A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging 被引量:1
16
作者 王志立 高昆 +4 位作者 陈健 葛昕 朱佩平 田扬超 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第11期547-553,共7页
Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refr... Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse- projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensionak phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method. 展开更多
关键词 x-ray imaging phase contrast information retrieval shifting curve
下载PDF
A review of geometric calibration for different 3-D X-ray imaging systems 被引量:1
17
作者 Yang,Yao Li,Liang Chen,Zhi-Qiang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期194-204,共11页
A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction imag... A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction image,exact knowledge of geometry is indispensable.Nowadays,geometric calibration has become a necessary step after completing CT system installation.Various geometric calibration methods have been reported with the fast development of 3-D X-ray imaging techniques.In these methods,different measuring methods,calibration phantoms or markers,and calculation algorithms were involved with their respective advantages and disadvantages.This paper reviews the history and current state of geometric calibration methods for different3-D X-ray imaging systems.Various calibration algorithms are presented and summarized,followed by our discussion and outlook. 展开更多
关键词 x射线成像系统 几何校正 三维 计算机断层扫描 计算机层析成像 x射线成像技术 综述 校准方法
下载PDF
Simple phase extraction in x-ray differential phase contrast imaging
18
作者 刘鑫 郭金川 +2 位作者 雷耀虎 李冀 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第2期563-567,共5页
A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a stro... A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified. 展开更多
关键词 x-ray imaging x-ray interferometry Talbot and self-imaging effects phase contrast imaging
下载PDF
Elemental x-ray imaging using Zernike phase contras
19
作者 邵其刚 陈健 +5 位作者 Faiz Wali 鲍园 王志立 朱佩平 田扬超 高昆 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第10期545-548,共4页
We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images ar... We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images are subtracted to obtain the target element: one is at the absorption edge of the target element and the other is near the absorption edge. The x-ray exposure required by this method is expected to be significantly lower than that of conventional absorption-based x-ray elemental imaging methods. Numerical calculations confirm the advantages of this highly efficient imaging method. 展开更多
关键词 x-ray imaging Zernike phase contrast elemental imaging
下载PDF
Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
20
作者 姜庆军 冯赟 +5 位作者 肖湘生 刘士远 陈敏 肖体乔 田玉莲 朱佩平 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期34-37,共4页
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in... Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents. 展开更多
关键词 x线检查 同步加速器 医疗技术 临床检查
下载PDF
上一页 1 2 250 下一页 到第